Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Respir Res ; 25(1): 82, 2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38331869

RESUMEN

BACKGROUND: Post COVID-19 syndrome is characterized by several cardiorespiratory symptoms but the origin of patients' reported symptomatology is still unclear. METHODS: Consecutive post COVID-19 patients were included. Patients underwent full clinical evaluation, symptoms dedicated questionnaires, blood tests, echocardiography, thoracic computer tomography (CT), spirometry including alveolar capillary membrane diffusion (DM) and capillary volume (Vcap) assessment by combined carbon dioxide and nitric oxide lung diffusion (DLCO/DLNO) and cardiopulmonary exercise test. We measured surfactant derive protein B (immature form) as blood marker of alveolar cell function. RESULTS: We evaluated 204 consecutive post COVID-19 patients (56.5 ± 14.5 years, 89 females) 171 ± 85 days after the end of acute COVID-19 infection. We measured: forced expiratory volume (FEV1) 99 ± 17%pred, FVC 99 ± 17%pred, DLCO 82 ± 19%, DM 47.6 ± 14.8 mL/min/mmHg, Vcap 59 ± 17 mL, residual parenchymal damage at CT 7.2 ± 3.2% of lung tissue, peakVO2 84 ± 18%pred, VE/VCO2 slope 112 [102-123]%pred. Major reported symptoms were: dyspnea 45% of cases, tiredness 60% and fatigability 77%. Low FEV1, Vcap and high VE/VCO2 slope were associated with persistence of dyspnea. Tiredness was associated with high VE/VCO2 slope and low PeakVO2 and FEV1 while fatigability with high VE/VCO2 slope. SPB was fivefold higher in post COVID-19 than in normal subjects, but not associated to any of the referred symptoms. SPB was negatively associated to Vcap. CONCLUSIONS: In patients with post COVID-19, cardiorespiratory symptoms are linked to VE/VCO2 slope. In these patients the alveolar cells are dysregulated as shown by the very high SPB. The Vcap is low likely due to post COVID-19 pulmonary endothelial/vasculature damage but DLCO is only minimally impaired being DM preserved.


Asunto(s)
COVID-19 , Insuficiencia Cardíaca , Femenino , Humanos , Síndrome Post Agudo de COVID-19 , COVID-19/complicaciones , Pulmón/diagnóstico por imagen , Pruebas de Función Respiratoria , Prueba de Esfuerzo/métodos , Disnea , Consumo de Oxígeno/fisiología , Insuficiencia Cardíaca/diagnóstico
2.
Am J Cardiol ; 209: 173-180, 2023 12 15.
Artículo en Inglés | MEDLINE | ID: mdl-37858597

RESUMEN

Low-flow low-gradient (LF-LG) aortic stenosis (AS) may occur with preserved or depressed left ventricular ejection fraction (LVEF). Both situations represent the most challenging subset of patients to manage and generally have a poor prognosis. Few and controversial data exist on the outcomes of these patients compared with normal flow-high gradient (NF-HG) AS after transcatheter aortic valve replacement (TAVR). We sought to characterize different transvalvular flow-gradient patterns and to examine their prognostic value after TAVR. We enrolled 1,208 patients with severe AS and categorized as follow: 976 patients NF-HG (mean aortic pressure gradient [MPG] ≥40 mm Hg), 107 paradoxical LF-LG (pLF-LG, MPG <40 mm Hg, LVEF ≥50%, stroke volume index <35 ml/m2), and 125 classical LF-LG (cLF-LG) (MPG <40 mm Hg, LVEF <50%, stroke volume index <35 ml/m2). When compared with NF-HG and pLF-LG, cLF-LG had a worse symptomatic status (New York Heart Association III to IV 86% vs 62% and 67%, p <0.001), a higher prevalence of eccentric hypertrophy and a higher level of LV global afterload reflected by a higher valvuloarterial impedance. Valvular function after TAVR was excellent over time in all patients. While 30-day mortality (p = 0.911) did not differ significantly among groups, cLF-LG had a lower 5-year survival rate (LF-LG 50% vs pLF-LG 62% and NF-HG 68%, p <0.05). cLF-LG was associated with a hazard ratio for mortality of 2.41 (95% confidence interval 1.65 to 3.52, p <0.001). In conclusion, TAVR is an effective procedure regardless of transvalvular flow-gradient patterns. However, special care should be given to characterized hemodynamic of AS, as patients with pLF-LG had similar survival rates than patients with NF-HG, whereas cLF-LG is associated with a twofold increased risk of mortality at 5-year follow-up.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Volumen Sistólico , Función Ventricular Izquierda , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
3.
J Clin Med ; 12(17)2023 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-37685807

RESUMEN

Biological valve failure (BVF) is an inevitable condition that compromises the durability of biological heart valves (BHVs). It stems from various causes, including rejection, thrombosis, and endocarditis, leading to a critical state of valve dysfunction. Echocardiography, cardiac computed tomography, cardiac magnetic resonance, and nuclear imaging play pivotal roles in the diagnostic multimodality workup of BVF. By providing a comprehensive overview of the pathophysiology of BVF and the diagnostic approaches in different clinical scenarios, this review aims to aid clinicians in their decision-making process. The significance of early detection and appropriate management of BVF cannot be overstated, as these directly impact patients' prognosis and their overall quality of life. Ensuring timely intervention and tailored treatments will not only improve outcomes but also alleviate the burden of this condition on patients' life. By prioritizing comprehensive assessments and adopting the latest advancements in diagnostic technology, medical professionals can significantly enhance their ability to manage BVF effectively.

4.
J Cardiovasc Dev Dis ; 10(4)2023 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-37103029

RESUMEN

Quantification of chronic mitral regurgitation (MR) is essential to guide patients' clinical management and define the need and appropriate timing for mitral valve surgery. Echocardiography represents the first-line imaging modality to assess MR and requires an integrative approach based on qualitative, semiquantitative, and quantitative parameters. Of note, quantitative parameters, such as the echocardiographic effective regurgitant orifice area, regurgitant volume (RegV), and regurgitant fraction (RegF), are considered the most reliable indicators of MR severity. In contrast, cardiac magnetic resonance (CMR) has demonstrated high accuracy and good reproducibility in quantifying MR, especially in cases with secondary MR; nonholosystolic, eccentric, and multiple jets; or noncircular regurgitant orifices, where quantification with echocardiography is an issue. No gold standard for MR quantification by noninvasive cardiac imaging has been defined so far. Only a moderate agreement has been shown between echocardiography, either with transthoracic or transesophageal approaches, and CMR in MR quantification, as supported by numerous comparative studies. A higher agreement is evidenced when echocardiographic 3D techniques are used. CMR is superior to echocardiography in the calculation of the RegV, RegF, and ventricular volumes and can provide myocardial tissue characterization. However, echocardiography remains fundamental in the pre-operative anatomical evaluation of the mitral valve and of the subvalvular apparatus. The aim of this review is to explore the accuracy of MR quantification provided by echocardiography and CMR in a head-to-head comparison between the two techniques, with insight into the technical aspects of each imaging modality.

6.
J Cardiovasc Dev Dis ; 9(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35050222

RESUMEN

Prosthetic valve (PV) dysfunction (PVD) is a complication of mechanical or biological PV. Etiologic mechanisms associated with PVD include fibrotic pannus ingrowth, thrombosis, structural valve degeneration, and endocarditis resulting in different grades of obstruction and/or regurgitation. PVD can be life threatening and often challenging to diagnose due to the similarities between the clinical presentations of different causes. Nevertheless, identifying the cause of PVD is critical to treatment administration (thrombolysis, surgery, or percutaneous procedure). In this report, we review the role of multimodality imaging in the diagnosis of PVD. Specifically, this review discusses the characteristics of advanced imaging modalities underlying the importance of an integrated approach including 2D/3D transthoracic and transesophageal echocardiography, fluoroscopy, and computed tomography. In this scenario, it is critical to understand the strengths and weaknesses of each modality according to the suspected cause of PVD. In conclusion, for patients with suspected or known PVD, this stepwise imaging approach may lead to a simplified, more rapid, accurate and specific workflow and management.

7.
Front Cardiovasc Med ; 9: 1050476, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36704460

RESUMEN

Mitral valve prolapse (MVP) is the leading cause of mitral valve surgery. Echocardiography is the principal imaging modality used to diagnose MVP, assess the mitral valve morphology and mitral annulus dynamics, and quantify mitral regurgitation. Three-dimensional (3D) echocardiographic (3DE) imaging represents a consistent innovation in cardiovascular ultrasound in the last decades, and it has been implemented in routine clinical practice for the evaluation of mitral valve diseases. The focus of this review is the role and the advantages of 3DE in the comprehensive evaluation of MVP, intraoperative and intraprocedural monitoring.

8.
Bioengineering (Basel) ; 8(9)2021 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-34562939

RESUMEN

BACKGROUND: Mitral valve regurgitation (MR) is the most common valvular heart disease and current variables associated with MR recurrence are still controversial. We aim to develop a machine learning-based prognostic model to predict causes of mitral valve (MV) repair failure and MR recurrence. METHODS: 1000 patients who underwent MV repair at our institution between 2008 and 2018 were enrolled. Patients were followed longitudinally for up to three years. Clinical and echocardiographic data were included in the analysis. Endpoints were MV repair surgical failure with consequent MV replacement or moderate/severe MR (>2+) recurrence at one-month and moderate/severe MR recurrence after three years. RESULTS: 817 patients (DS1) had an echocardiographic examination at one-month while 295 (DS2) also had one at three years. Data were randomly divided into training (DS1: n = 654; DS2: n = 206) and validation (DS1: n = 164; DS2 n = 89) cohorts. For intra-operative or early MV repair failure assessment, the best area under the curve (AUC) was 0.75 and the complexity of mitral valve prolapse was the main predictor. In predicting moderate/severe recurrent MR at three years, the best AUC was 0.92 and residual MR at six months was the most important predictor. CONCLUSIONS: Machine learning algorithms may improve prognosis after MV repair procedure, thus improving indications for correct candidate selection for MV surgical repair.

9.
J Cardiovasc Dev Dis ; 8(7)2021 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-34202460

RESUMEN

MitraClip (MC) is the most common percutaneous treatment for severe mitral regurgitation (MR). An accurate two-dimensional and three-dimensional echocardiographic (3DTEE) imaging is mandatory for the optimal procedural result. Recently transillumination 3DTEE rendering (3DTr) has been introduced integrating a virtual light source into the dataset and with the addition of glass effect (3DGl) allows to adjust tissue transparency improving depth perception and anatomical structure delineation in comparison with the standard 3DTEE (3DSt). The aim of this retrospective study in 30 patients undergoing MC, was to compare 3DSt, 3DTr, and 3DGl in mitral valve (MV) evaluation and procedural result assessment. 3DTEE acquisitions obtained before and after MC were processed with 3DSt, 3DTr, and 3DGl rendering. Each reconstruction was scored for quality and for ability to recognize MV anatomy, MR origin, clip position, dimension and grasping. Imaging quality was judged good or optimal in 52%, 76%, and 96% in 3DSt, 3DTr, and 3DGl reconstructions respectively. In 26/30 patients a diagnostic incremental value was found with 3DTr vs. 3DSt and in 15/26 with 3DGl vs. 3DTr and 3DSt. Only 3DGl with perpendicular cropping of the clip allowed to visualize and measure the grasped portion of each mitral leaflets. 3DTEE imaging during MC may be improved by 3DTr and 3DGl providing a better evaluation of MV, of leaflet grasping and of residual MR jets after MC.

10.
Am J Cardiol ; 150: 101-109, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-34020771

RESUMEN

The long-term outcome of mechanical aortic and mitral prosthetic valve (A-PV, M-PV) dysfunction (PVD) remains a serious complication associated with high morbidity and mortality. We sought to evaluate the incremental diagnostic value of combined transthoracic echocardiography (TTE) and fluoroscopy (F) in patients with suspected PVD. A total of 354 patients (178 A-PV, 176 M-PV) were imaged by TTE and F within 5 days of hospital admission. PVD was confirmed by transesophageal echocardiography, computed tomography, effective thrombolysis, or surgical inspection. PVD was confirmed in 101 patients (57%) with M-PV and 99 (55%) with A-PV. Regardless of the mechanism of PVD, TTE shows good sensitivity and specificity, with accuracy of 80% for M-PV and 91% for A-PV. F shows high specificity, but low sensitivity with accuracy of 68% for M-PV and 78% for A-PV. The integration of TTE + F significantly improved accuracy both for M-PV (83%) and A-PV (96%). At ROC analysis, the combined model of TTE + F showed the highest area under the curve for the detection of PVD compared with TTE and F alone (p < 0.001). In conclusion, in patients with a clinical suspicion of PVD, the combined model of TTE + F offers incremental value over TTE or F alone. This multimodality imaging approach overcomes limitations of TTE or F alone and provides prompt identification of patients who may require further imaging assessment and/or closer follow up.


Asunto(s)
Prótesis Valvulares Cardíacas/efectos adversos , Falla de Prótesis , Anciano , Ecocardiografía , Femenino , Fluoroscopía , Humanos , Italia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Terapia Trombolítica , Tomografía Computarizada por Rayos X
12.
J Clin Med ; 10(3)2021 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-33494387

RESUMEN

Cardiovascular imaging is developing at a rapid pace and the newer modalities, in particular three-dimensional echocardiography, allow better analysis of heart structures. Identifying valve lesions and grading their severity represents crucial information and nowadays is strengthened by the introduction of new software, such as transillumination, which provide detailed morphology descriptions. Chambers quantification has never been so rapid and accurate: machine learning algorithms generate automated volume measurements, including left ventricular systolic and diastolic function, which is extremely important for clinical decisions. This review provides an overview of the latest innovations in the echocardiography field, and is helpful by providing a better insight into heart diseases.

13.
Heart ; 107(1): 25-32, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32723759

RESUMEN

OBJECTIVE: Mitral annular disjunction (MAD) is an abnormality linked to mitral valve prolapse (MVP), possibly associated with malignant ventricular arrhythmias. We assessed the agreement among different imaging techniques for MAD identification and measurement. METHODS: 131 patients with MVP and significant mitral regurgitation undergoing transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) were retrospectively enrolled. Transoesophageal echocardiography (TOE) was available in 106 patients. MAD was evaluated in standard long-axis views (four-chamber, two-chamber, three-chamber) by each technique. RESULTS: Considering any-length MAD, MAD prevalence was 17.3%, 25.5%, 42.0% by TTE, TOE and CMR, respectively (p<0.05). The agreement on MAD identification was moderate between TTE and CMR (κ=0.54, 95% CI 0.49 to 0.59) and good between TOE and CMR (κ=0.79, 95% CI 0.74 to 0.84). Assuming CMR as reference and according to different cut-off values for MAD (≥2 mm, ≥4 mm, ≥6 mm), specificity (95% CI) of TTE and TOE was 99.6 (99.0 to 100.0)% and 98.7 (97.4 to 100.0)%; 99.3 (98.4 to 100.0)% and 97.6 (95.8 to 99.4)%; 97.8 (96.2 to 99.3)% and 93.2 (90.3 to 96.1)%, respectively; sensitivity (95% CI) was 43.1 (37.8 to 48.4)% and 74.5 (69.4 to 79.5)%; 54.0 (48.7 to 59.3)% and 88.9 (85.2 to 92.5)%; 88.0 (84.5 to 91.5)% and 100.0 (100.0 to 100.0)%, respectively. MAD length was 8.0 (7.0-10.0), 7.0 (5.0-8.0], 5.0 (4.0-7.0) mm, respectively by TTE, TOE and CMR. Agreement on MAD measurement was moderate between TTE and CMR (ρ=0.73) and strong between TOE and CMR (ρ=0.86). CONCLUSIONS: An integrated imaging approach could be necessary for a comprehensive assessment of patients with MVP and symptoms suggestive for arrhythmias. If echocardiography is fundamental for the anatomic and haemodynamic characterisation of the MV disease, CMR may better identify small length MAD as well as myocardial fibrosis.


Asunto(s)
Técnicas de Imagen Cardíaca , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/diagnóstico por imagen , Adulto , Anciano , Ecocardiografía , Ecocardiografía Transesofágica , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/patología , Prolapso de la Válvula Mitral/patología , Imagen Multimodal , Estudios Retrospectivos
14.
Int J Cardiol ; 299: 228-234, 2020 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-31353154

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is frequently associated with severe aortic stenosis, but its influence on outcomes after transcatheter aortic valve implantation (TAVI) remains controversial. This study sought to assess the baseline etiology and degree of MR in TAVI population, identify the predictors of MR changes and investigate the clinical and prognostic impact of baseline MR at mid and long-term follow-up. METHODS: We enrolled 572 consecutive patients who underwent TAVI. MR degree and etiology were evaluated by echocardiography at baseline and 1-year follow-up. Clinical outcomes were obtained up to 3-year follow-up. RESULTS: At baseline, 168 patients (29%) had moderate-to-severe MR (MR ≥ 2). Organic MR was more frequently associated with MR ≥ 2 (MR < 2: 20%, MR ≥ 2: 43%, p < 0.001). Relevant MR had improved more in functional MR (79%) compared to organic MR (50%, p = 0.001). At the multivariate analysis, the coexistence of coronary artery disease (p = 0.026), absence of atrial fibrillation (p = 0.038) and functional etiology (p = 0.025) were predictors of MR improvement after TAVI. Patients with baseline MR ≥ 2 had a higher mortality rate than those with MR < 2 at 1-year and 3-year follow-up. Moreover, a landmark analysis starting from 1-year to 3-year follow-up, demonstrated that organic MR was associated with an increased risk of mortality throughout 3-year follow-up compared with functional MR, irrespective of MR severity. CONCLUSIONS: Baseline MR ≥ 2 in TAVI patients was associated with early and late mortality rate. At 1-year, significant improvement in MR severity was observed mainly in patients with functional MR ≥ 2. Organic MR ≥ 2 had a negative impact on 3-year, but not 1-year, mortality rate.


Asunto(s)
Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano , Anciano de 80 o más Años , Ecocardiografía/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
15.
Int J Cardiovasc Imaging ; 35(2): 275-284, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30430329

RESUMEN

Three-dimensional echocardiographic (3DE) of right ventricle (RV) has been validated in many clinical settings. However, the necessity of complicated and off-line dedicated software has reduced its diffusion. A new simplified "on board" 3DE software (OB) has been developed to obtain RV volumes and ejection fraction (EF) together with several conventional parameters automatically derived from 3DE: tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), longitudinal strain (LS). Aims of this study were to evaluate feasibility and accuracy of OB RV analysis. A complete 2DE and 3DE with OB 3DRV evaluation was obtained in 35 normal subjects and 105 patients with different pathologies. Results were compared with the conventional off-line software (OFL) and with the 2D-derived corresponding values. A subgroup of 22 patients underwent also cardiac CMR. OB 3DRV was feasible in 133/140 cases (95%) in a mean time of 97.5 ± 33 s lower than OFL analysis (129 ± 52 s plus dataset loading 80 ± 24 s). Imaging quality was good in 84%. OB and OFL 3DE RV volumes and EF were similar. 3DE derived FSA and LS (but not TAPSE) were similar to 2DE values and correlated with tissue Doppler systolic peak velocity, dP/dt, systolic pulmonary pressure and myocardial performance index. OB RV volumes and EF well correlated with CMR. (bias + SD: - 21.5 ± 20 mL for EDV; - 8.2 ± 12.4 mL for ESV; - 1 ± 5.9% for EF). OB 3DE method is feasible, simple, time saving. It easily provides 3DE RV volumes and multiple functional parameters. Off-line operator border adjustment may improve accuracy of 3DE TAPSE.


Asunto(s)
Ecocardiografía Doppler , Ecocardiografía Tridimensional , Cardiopatías/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Cardiopatías/fisiopatología , Ventrículos Cardíacos/fisiopatología , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Programas Informáticos , Volumen Sistólico
16.
CASE (Phila) ; 2(6): 279-281, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30582091
17.
Am J Cardiol ; 122(7): 1195-1203, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-30082038

RESUMEN

MitraClip is a validated treatment for significant mitral regurgitation (MR) in high-risk patients. Aims of the study were to evaluate immediate changes in mitral valve (MV) geometry induced by MitraClip and correlations between baseline geometry and cardiac remodeling. Eighty patients who underwent MitraClip for primary (48%) or secondary (52%) MR were enrolled. Intraoperative transesophageal echocardiographic 3D images were acquired immediately before and after the procedure for MV annulus (MVA) morphology analysis. Transthoracic 3D echocardiography was performed preoperatively and at 6 months follow-up (6MFU). Patients were classified on the basis of MR reduction (ΔMR) at 6MFU as Optimal (ΔMR ≥ 2) or Suboptimal (ΔMR < 2). An optimal result was reached in 60 (75%) patients, whereas 20 subjects showed a ΔMR< 2 at 6MFU. The Optimal showed significantly smaller baseline MVA (antero-posterior diameter 4.05 ± 0.59 vs 4.43 ± 0.68 cm; anterolateral-posteromedial diameter 4.38 ± 0.56 vs 4.70 ± 0.73 cm; MVA circumference 14.1 ± 1.7 vs 15.1 ± 2.3 cm; and 3D area 14.8 ± 3.9 vs 17.4 ± 5.3 cm2), lower sphericity index and nonplanar angle compared with Suboptimal. A value of antero-posterior diameter ≥4.44cm was identified (receiver-operating characteristic curve) as a possible cut-off for preoperative identification of Suboptimal patients. Postoperatively, MitraClip induced reduction of MVA flattening (nonplanar angle), sphericity index, and size (as expressed by antero-posterior diameter, MVA circumference and area). At 6MFU, the Optimal showed significant decrease in left ventricular volumes and pulmonary artery systolic pressure. In conclusion, MitraClip induces remarkable changes in MVA geometry and favorable left ventricular remodeling is detected in patients with optimal mid-term outcome; a preprocedural antero-posterior diameter <4.44cm seems to be a potential predictor of mid-term optimal result.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Remodelación Ventricular , Anciano , Anciano de 80 o más Años , Femenino , Fluoroscopía , Humanos , Resultado del Tratamiento
18.
J Thorac Imaging ; 33(4): 232-239, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29927868

RESUMEN

PURPOSE: The aim of this study was to evaluate the feasibility and accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (2DTTE, 3DTTE) versus multidetector computed tomography (MDCT) in patients with ascending aortic (AA) dilation. MATERIALS AND METHODS: Fifty consecutive patients with AA dilation were evaluated by 2DTTE, X-plane (XP) 3DTTE, and MDCT. Aorta diameters were measured at aortic annulus, aortic root (SIN), sinotubular junction, AA, aortic arch before the prebrachiocephalic artery (PRE), and before left subclavian artery (INTRA). Leading edge-to-leading edge (L-L) and inner-to-inner (I-I) measurements were compared with MDCT data. RESULTS: Feasibility, quality of imaging, and accuracy was high with all echocardiographic methods. Specifically for MDCT maximum SIN diameter, the best correlation and agreement was obtained using XP maximum diameter at 3DTTE (MDCT: 44.8±7.4 mm vs. XP: 44.4±7.4 mm; r=0.975; bias=-0.4 mm). The same was true for AA maximum diameter at MDCT (MDCT: 46.6±8.1 mm vs. XP: 47.5±8.1 mm; r=0.991; bias=0.1 mm). For aortic arch the best correlation and agreement with MDCT were as follows: 2DTTE L-L diameter for arch PRE (MDCT: 37.9±5.3 mm vs. TTE: 36.6±4.5 mm; r=0.927; bias=-0.9 mm) and MDCT minimum diameter with XP minimum diameter for arch INTRA (MDCT: 28.2±5.0 mm vs. TTE 28.8±4.7 mm; r=0.939; bias=-0.3 mm). CONCLUSION: In patients with aortic dilatation or aneurysm, new techniques (mainly 2D-3D probes allowing XP views) facilitate accuracy of aortic measurements at different sites of the vessel and allow standardization of analysis to better compare with MDCT.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Enfermedades de la Aorta/diagnóstico por imagen , Ecocardiografía/métodos , Tomografía Computarizada Multidetector/métodos , Aorta Torácica/patología , Enfermedades de la Aorta/patología , Dilatación Patológica , Ecocardiografía Tridimensional/métodos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
Eur Heart J Cardiovasc Imaging ; 19(4): 389-397, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28379513

RESUMEN

Aims: Scarce data are available on the long-term structural and functional changes of prosthetic valves after transcatheter aortic valve implantation (TAVI). The objective was to evaluate with echocardiography the long-term structural and functional changes of prosthetic valves after TAVI. Methods and results: Structural valve deterioration (SVD) was defined as leaflet thickening ≥3mm, presence of calcification and abnormal leaflet motion. Five-year echocardiographic follow-up was available in 96 out of 318 patients who underwent TAVI with a balloon-expandable device between April 2008 and December 2011. At 1-year follow-up, no patient showed SVD. At 5-year follow-up, SVD were observed in 29 (30%) patients who showed also a significant reduction of aortic valve area (AVA) together with an increase of mean and peak aortic pressure gradients at the latest echocardiography evaluation. Moreover, rate of central aortic valve regurgitation ≥2 was higher in SVD patients as compared to those without SVD, while there was no difference in terms of paravalvular regurgitation. Despite SVD, one patient only reached the criteria for severe stenosis and no reintervention was needed at 5-year follow-up. Variables independently associated with SVD were female sex, small body surface area, use of a 23 mm valve, and small AVA at pre-discharge echocardiogram. Conclusion: At 5-year follow-up, 30% of patients who underwent TAVI with a balloon-expandable valve showed initial SVD. However, SVD was not associated with severe stenosis in most of the patients and had no significant impact on and clinical outcome.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Análisis de Varianza , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Italia , Masculino , Análisis Multivariante , Diseño de Prótesis , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
20.
Am J Cardiol ; 118(1): 113-20, 2016 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-27184171

RESUMEN

A recent histological study of resected scallop-P2 in mitral valve (MV) prolapse, showed that chordae tendinae may be missing or hidden in superimposed fibrous tissue of the leaflets, contributing to their thickening. This may have relevant clinical implication because detailed analysis of MV leaflets has a central role in the evaluation of patients undergoing repair. The aim of this study was to analyze MV leaflets focusing on thickness of prolapsing segments and the presence of chordal rupture (CR). We enrolled 246 patients (age 63 ± 13 years, 72 men) with isolated P2 prolapse and also 50 age-matched patients with normal MV anatomy as control group. Transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) were retrospectively analyzed to quantify the length and the proximal and distal thickness of both anterior (A2) and posterior (P2) MV scallops. Measurements were performed at end diastole in the standard TTE and TEE views. TTE and TEE measurements were feasible in all cases. Echocardiographically 176 patients had CR (group A), 45 had no rupture (group B), and 25 had an uncertain diagnosis (group C). All pathological groups showed thickening and elongation of involved leaflets versus normal, whereas no differences in leaflets characteristics were found among MV groups. Most patients undergoing MV repair had CR with thickening of the prolapsed segment. These findings are in agreement with recent histological studies showing superimposed fibrous tissue on MV leaflets partially including ruptured chordae. This may also explain that in cases without ruptured chordae, thickness of the leaflets is markedly increased (hidden chordae?). In conclusion, detailed analysis of MV apparatus may further improve knowledge of these patients and may influence surgical timing.


Asunto(s)
Cuerdas Tendinosas/diagnóstico por imagen , Ecocardiografía Transesofágica , Prolapso de la Válvula Mitral/diagnóstico por imagen , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prolapso de la Válvula Mitral/cirugía , Valor Predictivo de las Pruebas , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...