Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Clin Med ; 11(13)2022 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-35806990

RESUMEN

(1) Background: Individual PEEP settings (PEEPIND) may improve intraoperative oxygenation and optimize lung mechanics. However, there is uncertainty concerning the optimal procedure to determine PEEPIND. In this secondary analysis of a randomized controlled clinical trial, we compared different methods for PEEPIND determination. (2) Methods: Offline analysis of decremental PEEP trials was performed and PEEPIND was retrospectively determined according to five different methods (EIT-based: RVDI method, Global Inhomogeneity Index [GI], distribution of tidal ventilation [EIT VT]; global dynamic and quasi-static compliance). (3) Results: In the 45 obese and non-obese patients included, PEEPIND using the RVDI method (PEEPRVD) was 16.3 ± 4.5 cm H2O. Determination of PEEPIND using the GI and EIT VT resulted in a mean difference of −2.4 cm H2O (95%CI: −1.2;−3.6 cm H2O, p = 0.01) and −2.3 cm H2O (95% CI: −0.9;3.7 cm H2O, p = 0.01) to PEEPRVD, respectively. PEEPIND selection according to quasi-static compliance showed the highest agreement with PEEPRVD (p = 0.67), with deviations > 4 cm H2O in 3/42 patients. PEEPRVD and PEEPIND according to dynamic compliance also showed a high level of agreement, with deviations > 4 cm H2O in 5/42 patients (p = 0.57). (4) Conclusions: High agreement of PEEPIND determined by the RVDI method and compliance-based methods suggests that, for routine clinical practice, PEEP selection based on best quasi-static or dynamic compliance is favorable.

2.
Vet Anaesth Analg ; 48(3): 324-333, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33741264

RESUMEN

OBJECTIVES: To compare pulmonary gas exchange, tissue oxygenation and cardiovascular effects of four levels of end-expiratory pressure: no positive end-expiratory pressure (ZEEP), positive end-expiratory pressure (PEEP) of maximal respiratory system compliance (PEEPmaxCrs), PEEPmaxCrs + 2 cmH2O (PEEPmaxCrs+2), PEEPmaxCrs + 4 cmH2O (PEEPmaxCrs+4), in isoflurane-anesthetized dogs. STUDY DESIGN: Prospective randomized crossover study. ANIMALS: A total of seven healthy male Beagle dogs, aged 1 year and weighing 10.2 ± 0.7 kg (mean ± standard deviation). METHODS: The dogs were administered acepromazine and anesthesia was induced with propofol and maintained with isoflurane. Ventilation was controlled for 4 hours with ZEEP, PEEPmaxCrs, PEEPmaxCrs+2 or PEEPmaxCrs+4. Cardiovascular, pulmonary gas exchange and tissue oxygenation data were evaluated at 5, 60, 120, 180 and 240 minutes of ventilation and compared using a mixed-model anova followed by Bonferroni test. p < 0.05 was considered significant. RESULTS: Cardiac index (CI) and mean arterial pressure (MAP) were lower in all PEEP treatments at 5 minutes when compared with ZEEP. CI persisted lower throughout the 4 hours only in PEEPmaxCrs+4 with the lowest CI at 5 minutes (2.15 ± 0.70 versus 3.45 ± 0.94 L minute-1 m-2). At 180 and 240 minutes, MAP was lower in PEEPmaxCrs+4 than in PEEPmaxCrs, with the lowest value at 180 minutes (58 ± 7 versus 67 ± 7 mmHg). Oxygen delivery index (DO2I) was lower in PEEPmaxCrs+4 than in ZEEP at 5, 60, 120 and 180 minutes. Venous admixture was not different among treatments. CONCLUSION AND CLINICAL RELEVANCE: The use of PEEP caused a transient decrease in MAP and CI in lung-healthy dogs anesthetized with isoflurane, which improved after 60 minutes of ventilation in all levels of PEEP except PEEPmaxCrs+4. A clinically significant improvement in arterial oxygenation and DO2I was not observed with PEEPmaxCrs and PEEPmaxCrs+2 in comparison with ZEEP, whereas PEEPmaxCrs+4 decreased DO2I.


Asunto(s)
Perros , Isoflurano , Animales , Estudios Cruzados , Perros/fisiología , Masculino , Respiración con Presión Positiva/veterinaria , Estudios Prospectivos , Intercambio Gaseoso Pulmonar , Respiración Artificial/veterinaria
3.
Br J Anaesth ; 125(3): 373-382, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32665059

RESUMEN

BACKGROUND: Robot-assisted laparoscopic radical prostatectomy requires general anaesthesia, extreme Trendelenburg positioning and capnoperitoneum. Together these promote impaired pulmonary gas exchange caused by atelectasis and may contribute to postoperative pulmonary complications. In morbidly obese patients, a recruitment manoeuvre (RM) followed by individualised PEEP improves intraoperative oxygenation and end-expiratory lung volume (EELV). We hypothesised that individualised PEEP with initial RM similarly improves intraoperative oxygenation and EELV in non-obese individuals undergoing robot-assisted prostatectomy. METHODS: Forty males (age, 49-76 yr; BMI <30 kg m-2) undergoing prostatectomy received volume-controlled ventilation (tidal volume 8 ml kg-1 predicted body weight). Participants were randomised to either (1) RM followed by individualised PEEP (RM/PEEPIND) optimised using electrical impedance tomography or (2) no RM with 5 cm H2O PEEP. The primary outcome was the ratio of arterial oxygen partial pressure to fractional inspired oxygen (Pao2/Fio2) before the last RM before extubation. Secondary outcomes included regional ventilation distribution and EELV which were measured before, during, and after anaesthesia. The cardiovascular effects of RM/PEEPIND were also assessed. RESULTS: In 20 males randomised to RM/PEEPIND, the median PEEPIND was 14 cm H2O [inter-quartile range, 8-20]. The Pao2/Fio2 was 10.0 kPa higher with RM/PEEPIND before extubation (95% confidence interval [CI], 2.6-17.3 kPa; P=0.001). RM/PEEPIND increased end-expiratory lung volume by 1.49 L (95% CI, 1.09-1.89 L; P<0.001). RM/PEEPIND also improved the regional ventilation of dependent lung regions. Vasopressor and fluid therapy was similar between groups, although 13 patients randomised to RM/PEEPIND required pharmacological therapy for bradycardia. CONCLUSION: In non-obese males, an individualised ventilation strategy improved intraoperative oxygenation, which was associated with higher end-expiratory lung volumes during robot-assisted laparoscopic prostatectomy. CLINICAL TRIAL REGISTRATION: DRKS00004199 (German clinical trials registry).


Asunto(s)
Impedancia Eléctrica , Respiración con Presión Positiva/métodos , Prostatectomía/métodos , Procedimientos Quirúrgicos Robotizados/métodos , Anciano , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
4.
Vet Anaesth Analg ; 46(3): 360-364, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30772260

RESUMEN

OBJECTIVE: To evaluate the effect of two doses of fentanyl upon chest wall rigidity of dogs anesthetized at equipotent doses of isoflurane [1.3 minimum alveolar concentration (MACISO) of each dose of fentanyl]. STUDY DESIGN: Prospective crossover randomized study. ANIMALS: A group of eight male Beagle dogs, approximately 1 year old and weighing 12.1 ± 1.6 kg (mean ± standard deviation). METHODS: The dogs were anesthetized with isoflurane and instrumented for the measurement of esophageal pressure (PESO), flow (V˙) and volume (V). Chest wall elastance (ECW) was estimated by multiple linear regression of the model. PESO(t) = V˙(t) × RCW + V(t) × ECW + EEPESO where t is time, RCW is chest wall resistance and EEPESO is end-expiratory PESO. Chest wall compliance (CCW) was calculated as 1/ECW and normalized to the body weight of each dog (mL cmH2O-1 kg-1). Anesthesia was maintained at 1.3 MACISO for at least 15 minutes and CCW recorded (CCW-ISO). The dogs were randomly assigned to the lower fentanyl dose [loading dose (33 µg kg-1) and infusion (0.2 µg kg-1 minute-1)] or the higher fentanyl dose [loading dose (102 µg kg-1) and infusion (0.8 µg kg-1 minute-1)]. After 60 minutes of fentanyl infusion, CCW was recorded for each dose (CCW-FENT). During fentanyl infusion, the dogs were maintained at equipotent doses of isoflurane (1.3 MACISO for each fentanyl dose). A two-way analysis of variance followed by a Bonferroni test was used to compare CCW-ISO and CCW-FENT in both treatments and CCW-FENT between treatments. A p value <0.05 was considered significant. RESULTS: Neither of the fentanyl doses decreased CCW and there was no difference in CCW-FENT between doses. CONCLUSIONS AND CLINICAL RELEVANCE: Fentanyl at the studied doses did not result in chest wall rigidity in dogs anesthetized with equipotent doses of isoflurane (1.3 MACISO).


Asunto(s)
Adyuvantes Anestésicos/farmacología , Analgésicos Opioides/farmacología , Anestesia/veterinaria , Perros , Fentanilo/farmacología , Isoflurano/farmacología , Pared Torácica/efectos de los fármacos , Anestésicos por Inhalación/farmacología , Animales , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Fentanilo/administración & dosificación , Isoflurano/administración & dosificación , Masculino , Estudios Prospectivos , Ventilación Pulmonar/efectos de los fármacos , Distribución Aleatoria
5.
Lung ; 196(3): 335-342, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29435738

RESUMEN

PURPOSE: We compared respiratory mechanics between the positive end-expiratory pressure of minimal respiratory system elastance (PEEPminErs) and three levels of PEEP during low-tidal-volume (6 mL/kg) ventilation in rats. METHODS: Twenty-four rats were anesthetized, paralyzed, and mechanically ventilated. Airway pressure (Paw), flow (F), and volume (V) were fitted by a linear single compartment model (LSCM) Paw(t) = Ers × V(t) + Rrs × F(t) + PEEP or a volume- and flow-dependent SCM (VFDSCM) Paw(t) = (E1 + E2 × V(t)) × V(t) + (K1 + K2 × |F(t)|) × F(t) + PEEP, where Ers and Rrs are respiratory system elastance and resistance, respectively; E1 and E2× V are volume-independent and volume-dependent Ers, respectively; and K1 and K2 × F are flow-independent and flow-dependent Rrs, respectively. Animals were ventilated for 1 h at PEEP 0 cmH2O (ZEEP); PEEPminErs; 2 cmH2O above PEEPminErs (PEEPminErs+2); or 4 cmH2O above PEEPminErs (PEEPminErs+4). Alveolar tidal recruitment/derecruitment and overdistension were assessed by the index %E2 = 100 × [(E2 × VT)/(E1 + |E2| × VT)], and alveolar stability by the slope of Ers(t). RESULTS: %E2 varied between 0 and 30% at PEEPminErs in most respiratory cycles. Alveolar Tidal recruitment/derecruitment (%E2 < 0) and overdistension (%E2 > 30) were predominant in the absence of PEEP and in PEEP levels higher than PEEPminErs, respectively. The slope of Ers(t) was different from zero in all groups besides PEEPminErs+4. CONCLUSIONS: PEEPminErs presented the best compromise between alveolar tidal recruitment/derecruitment and overdistension, during 1 h of low-VT mechanical ventilation.


Asunto(s)
Elasticidad/fisiología , Pulmón/fisiología , Respiración con Presión Positiva/métodos , Mecánica Respiratoria/fisiología , Anestesia , Animales , Ratas , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar
6.
Biomed Eng Online ; 17(1): 3, 2018 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-29335011

RESUMEN

BACKGROUND: The multiple-breath washout (MBW) is able to provide information about the distribution of ventilation-to-volume (v/V) ratios in the lungs. However, the classical, all-parallel model may return skewed results due to the mixing effect of a common dead space. The aim of this work is to examine whether a novel mathematical model and algorithm is able to estimate v/V of a physical model, and to compare its results with those of the classical model. The novel model takes into account a dead space in series with the parallel ventilated compartments, allows for variable tidal volume (VT) and end-expiratory lung volume (EELV), and does not require a ideal step change of the inert gas concentration. METHODS: Two physical models with preset v/V units and a common series dead space (vd) were built and mechanically ventilated. The models underwent MBW with N2 as inert gas, throughout which flow and N2 concentration signals were acquired. Distribution of v/V was estimated-via nonnegative least squares, with Tikhonov regularization-with the classical, all-parallel model (with and without correction for non-ideal inspiratory N2 step) and with the new, generalized model including breath-by-breath vd estimates given by the Fowler method (with and without constrained VT and EELV). RESULTS: The v/V distributions estimated with constrained EELV and VT by the generalized model were practically coincident with the actual v/V distribution for both physical models. The v/V distributions calculated with the classical model were shifted leftwards and broader as compared to the reference. CONCLUSIONS: The proposed model and algorithm provided better estimates of v/V than the classical model, particularly with constrained VT and EELV.


Asunto(s)
Modelos Biológicos , Respiración Artificial , Respiración , Espiración/fisiología , Nitrógeno/metabolismo , Volumen de Ventilación Pulmonar
7.
Biomed Eng Online ; 15(1): 89, 2016 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-27480332

RESUMEN

BACKGROUND: This work presents a generalized technique to estimate pulmonary ventilation-to-volume (v/V) distributions using the multiple-breath nitrogen washout, in which both tidal volume (V T ) and the end-expiratory lung volume (EELV) are allowed to vary during the maneuver. In addition, the volume of the series dead space (v d ), unlike the classical model, is considered a common series unit connected to a set of parallel alveolar units. METHODS: The numerical solution for simulated data, either error-free or with the N2 measurement contaminated with the addition of Gaussian random noise of 3 or 5 % standard deviation was tested under several conditions in a computational model constituted by 50 alveolar units with unimodal and bimodal distributions of v/V. Non-negative least squares regression with Tikhonov regularization was employed for parameter retrieval. The solution was obtained with either unconstrained or constrained (V T , EELV and v d ) conditions. The Tikhonov gain was fixed or estimated and a weighting matrix (WM) was considered. The quality of estimation was evaluated by the sum of the squared errors (SSE) (between reference and recovered distributions) and by the deviations of the first three moments calculated for both distributions. Additionally, a shape classification method was tested to identify the solution as unimodal or bimodal, by counting the number of shape agreements after 1000 repetitions. RESULTS: The accuracy of the results showed a high dependence on the noise amplitude. The best algorithm for SSE and moments included the constrained and the WM solvers, whereas shape agreement improved without WM, resulting in 97.2 % for unimodal and 90.0 % for bimodal distributions in the highest noise condition. CONCLUSIONS: In conclusion this generalized method was able to identify v/V distributions from a lung model with a common series dead space even with variable V T . Although limitations remain in presence of experimental noise, appropriate combination of processing steps were also found to reduce estimation errors.


Asunto(s)
Modelos Biológicos , Nitrógeno/metabolismo , Ventilación Pulmonar , Respiración , Humanos , Análisis de los Mínimos Cuadrados , Volumen de Ventilación Pulmonar
8.
Respir Physiol Neurobiol ; 229: 34-42, 2016 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-27102012

RESUMEN

Mixtures of anhydrous ethyl alcohol and gasoline substituted for pure gasoline as a fuel in many Brazilian vehicles. Consequently, the concentrations of volatile organic compounds (VOCs) such as ketones, other organic compounds, and particularly aldehydes increased in many Brazilian cities. The current study aims to investigate whether formaldehyde, acetaldehyde, or mixtures of both impair lung function, morphology, inflammatory and redox responses at environmentally relevant concentrations. For such purpose, C57BL/6 mice were exposed to either medical compressed air or to 4 different mixtures of formaldehyde and acetaldehyde. Eight hours later animals were anesthetized, paralyzed and lung mechanics and morphology, inflammatory cells and IL-1ß, KC, TNF-α, IL-6, CCL2, MCP-1 contents, superoxide dismutase and catalalase activities were determined. The extra pulmonary respiratory tract was also analyzed. No differences could be detected between any exposed and control groups. In conclusion, no morpho-functional alterations were detected in exposed mice in relation to the control group.


Asunto(s)
Acetaldehído/toxicidad , Contaminantes Atmosféricos/toxicidad , Formaldehído/toxicidad , Pulmón/efectos de los fármacos , Compuestos Orgánicos Volátiles/toxicidad , Contaminación del Aire , Animales , Fenómenos Biomecánicos , Femenino , Pulmón/patología , Pulmón/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Ratones Endogámicos C57BL , Modelos Animales , Mucosa Nasal/efectos de los fármacos , Mucosa Nasal/metabolismo , Mucosa Nasal/patología , Estrés Oxidativo/efectos de los fármacos , Estrés Oxidativo/fisiología , Presión , Ventilación Pulmonar , Factores de Tiempo
9.
PLoS One ; 9(11): e110817, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25383882

RESUMEN

OBJECTIVES: Variable ventilation (VV) seems to improve respiratory function in acute lung injury and may be combined with positive end-expiratory pressure (PEEP) in order to protect the lungs even in healthy subjects. We hypothesized that VV in combination with moderate levels of PEEP reduce the deterioration of pulmonary function related to general anesthesia. Hence, we aimed at evaluating the alveolar stability and lung protection of the combination of VV at different PEEP levels. DESIGN: Randomized experimental study. SETTING: Animal research facility. SUBJECTS: Forty-nine male Wistar rats (200-270 g). INTERVENTIONS: Animals were ventilated during 2 hours with protective low tidal volume (VT) in volume control ventilation (VCV) or VV and PEEP adjusted at the level of minimum respiratory system elastance (Ers), obtained during a decremental PEEP trial subsequent to a recruitment maneuver, and 2 cmH2O above or below of this level. MEASUREMENTS AND MAIN RESULTS: Ers, gas exchange and hemodynamic variables were measured. Cytokines were determined in lung homogenate and plasma samples and left lung was used for histologic analysis and diffuse alveolar damage scoring. A progressive time-dependent increase in Ers was observed independent on ventilatory mode or PEEP level. Despite of that, the rate of increase of Ers and lung tissue IL-1 beta concentration were significantly lower in VV than in VCV at the level of the PEEP of minimum Ers. A significant increase in lung tissue cytokines (IL-6, IL-1 beta, CINC-1 and TNF-alpha) as well as a ventral to dorsal and cranial to caudal reduction in aeration was observed in all ventilated rats with no significant differences among groups. CONCLUSIONS: VV combined with PEEP adjusted at the level of the PEEP of minimal Ers seemed to better prevent anesthesia-induced atelectasis and might improve lung protection throughout general anesthesia.


Asunto(s)
Anestesia General , Alveolos Pulmonares/fisiología , Atelectasia Pulmonar/prevención & control , Ventilación Pulmonar/fisiología , Animales , Hemodinámica , Masculino , Respiración con Presión Positiva , Intercambio Gaseoso Pulmonar , Ratas , Ratas Wistar
10.
PLoS One ; 9(9): e103057, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25247308

RESUMEN

BACKGROUND: Measuring esophageal pressure (Pes) using an air-filled balloon catheter (BC) is the common approach to estimate pleural pressure and related parameters. However, Pes is not routinely measured in mechanically ventilated patients, partly due to technical and practical limitations and difficulties. This study aimed at comparing the conventional BC with two alternative methods for Pes measurement, liquid-filled and air-filled catheters without balloon (LFC and AFC), during mechanical ventilation with and without spontaneous breathing activity. Seven female juvenile pigs (32-42 kg) were anesthetized, orotracheally intubated, and a bundle of an AFC, LFC, and BC was inserted in the esophagus. Controlled and assisted mechanical ventilation were applied with positive end-expiratory pressures of 5 and 15 cmH2O, and driving pressures of 10 and 20 cmH2O, in supine and lateral decubitus. MAIN RESULTS: Cardiogenic noise in BC tracings was much larger (up to 25% of total power of Pes signal) than in AFC and LFC (<3%). Lung and chest wall elastance, pressure-time product, inspiratory work of breathing, inspiratory change and end-expiratory value of transpulmonary pressure were estimated. The three catheters allowed detecting similar changes in these parameters between different ventilation settings. However, a non-negligible and significant bias between estimates from BC and those from AFC and LFC was observed in several instances. CONCLUSIONS: In anesthetized and mechanically ventilated pigs, the three catheters are equivalent when the aim is to detect changes in Pes and related parameters between different conditions, but possibly not when the absolute value of the estimated parameters is of paramount importance. Due to a better signal-to-noise ratio, and considering its practical advantages in terms of easier calibration and simpler acquisition setup, LFC may prove interesting for clinical use.


Asunto(s)
Cateterismo/instrumentación , Esófago/fisiología , Pleura/fisiología , Porcinos/fisiología , Aire , Animales , Cateterismo/métodos , Femenino , Humanos , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Presión , Respiración Artificial , Mecánica Respiratoria , Relación Señal-Ruido
11.
Rev. bras. eng. biomed ; 30(2): 173-178, Apr.-June 2014. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-714732

RESUMEN

INTRODUCTION: Studies have shown increases in airway opening pressure (Pao) swings and work of breathing (WOB) by different continuous positive airway pressure (CPAP) devices at rest, but few address this issue during exercise. The aim of the present work was to analyze the imposed WOB (WOBi), the apparent resistance (Rapp) and swings of Pao (deltaP) of 3 CPAP assemblies at simulated exercise conditions. METHODS: The CPAP measures were obtained from: a commercial CPAP (Assembly 1), a high flow CPAP (Assembly 2) and the parallel association of these devices (Assembly 3). In each assembly the spring-loaded positive end-expiratory pressure (PEEP) valve was set to fully opened (mode A) or at the same CPAP pressure (mode B). The exercise protocol simulation, performed manually by a calibrated syringe and a metronome, employed a respiratory frequency of 30 bpm, tidal volume of 2.7 L and inspiratory-to-expiratory ratio of 1. The setups were evaluated at CPAP settings of 5, 10 and 15 cmH2O. RESULTS: The lowest deltaP as well as Rapp and WOBi were obtained with Assembly 3 in mode A with an adjusted CPAP of 10 cmH2O (deltaP=8.1 (0.5) cmH2O, WOBi=1.4 (0.14) cmH2O/L/s, Rapp= 1.3 (0.07) J/s) showed as median (interquartile range). CONCLUSION: For the conditions studied, the best CPAP setup was obtained with mode A.

12.
Anesth Analg ; 116(3): 627-33, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22467900

RESUMEN

BACKGROUND: A decremental positive end-expiratory pressure (PEEP) trial after full lung recruitment allows for the adjustment of the lowest PEEP that prevents end-expiratory collapse (open-lung PEEP). For a tidal volume (Vt) approaching zero, the PEEP of minimum respiratory system elastance (PEEP(minErs)) is theoretically equal to the pressure at the mathematical inflection point (MIP) of the pressure-volume curve, and seems to correspond to the open-lung PEEP in a decremental PEEP trial. Nevertheless, the PEEP(minErs) is dependent on Vt and decreases as Vt increases. To circumvent this dependency, we proposed the use of a second-order model in which the volume-independent elastance (E1) is used to set open-lung PEEP. METHODS: Pressure-volume curves and a recruitment maneuver followed by decremental PEEP trials, with a Vt of 6 and 12 mL/kg, were performed in 24 Wistar rats with acute lung injury induced by intraperitoneally injected (n = 8) or intratracheally instilled (n = 8) Escherichia coli lipopolysaccharide. In 8 control animals, the anterior chest wall was surgically removed after PEEP trials, and the protocol was repeated. Airway pressure (Paw) and flow (F) were continuously acquired and fitted by the linear single-compartment model (Paw = Rrs·F + Ers·V + PEEP, where Rrs is the resistance of the respiratory system, and V is volume) and the volume-dependent elastance model (Paw = Rrs·F + E1 + E2·V·V + PEEP, where E2·V is the volume-dependent elastance). From each model, PEEPs of minimum Ers and E1 (PEEP(minE1)) were identified and compared with each respective MIP. The accuracy of PEEPminE1 and PEEPminErs in estimating MIP was assessed by bias and precision plots. Comparisons among groups were performed with the unpaired t test whereas a paired t test was used between the control group before and after chest wall removal and within groups at different Vts. All P values were then corrected for multiple comparisons by the Bonferroni procedure. RESULTS: In all experimental groups, PEEPminErs, but not PEEPminE1, tended to decrease as Vt increased. The difference between MIP and PEEPminE1 exhibited a lower bias compared with the difference between MIP and PEEPminErs (P < 0.001). The PEEPminE1 was always significantly higher than the PEEPminErs (7.7 vs 3.8, P < 0.001) and better approached MIP (7.7 vs 7.3 cm H2O with P = 0.04 at low Vt, and 7.8 vs 7.1 cm H2O with P < 0.001 at high Vt). CONCLUSIONS: PEEPminE1 better identifies the open-lung PEEP independently of the adjusted Vt, and may be a practical, more individualized approach for PEEP titration.


Asunto(s)
Pulmón/fisiología , Respiración con Presión Positiva/métodos , Mecánica Respiratoria/fisiología , Volumen de Ventilación Pulmonar/fisiología , Animales , Masculino , Respiración con Presión Positiva/instrumentación , Ratas , Ratas Wistar
13.
Anesth Analg ; 116(3): 677-84, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22543064

RESUMEN

BACKGROUND: The volume-dependent single compartment model (VDSCM) has been applied for identification of overdistension in mechanically ventilated patients with acute lung injury. In this observational study we evaluated the use of the VDSCM to identify tidal recruitment/overdistension induced by tidal volume (Vt) and positive end-expiratory pressure (PEEP) in lung-healthy anesthetized subjects. METHODS: Fifteen patients (ASA physical status I-II) undergoing general anesthesia for elective plastic breast reconstruction surgery were mechanically ventilated in volume-controlled ventilation (VCV), with Vt of 8 mL•kg(-1) and PEEP of 0 cm H(2)O. With these settings, ventilatory mode was randomly adjusted in VCV or pressure-controlled ventilation (PCV) and PEEP was sequentially increased from 0 to 5 and 10 cm H(2)O, 5 min per step. Thereafter, PEEP was decreased to 0 cm H(2)O, Vt increased to 10 mL•kg(-1) and, keeping minute ventilation constant, PEEP was similarly increased to 5 and 10 cm H(2)O. Airway pressure and flow were continuously recorded and fitted to the VDSCM with or without considering flow-dependencies. A "distension index" (%E(2)) derived from the VDSCM was used to assess Vt and PEEP-induced recruitment/overdistension. Positive and negative values of %E(2) suggest tidal overdistension or tidal recruitment, respectively. In addition, the linear respiratory system elastance was calculated. Comparisons among variables at each PEEP value, Vt setting, ventilatory mode, and regression model considering or not considering flow-dependencies were performed with the Wilcoxon-sign rank test for paired samples (P < 0.05). Multiple comparisons were corrected with the Bonferroni method. The relative change in the estimated noisy variance was used as an index of the goodness of fit of the models. RESULTS: VDSCM including the flow-dependent parameter significantly improved estimated noisy variance in almost all experimental conditions (11.2 to 71.4, smallest of the lower and highest of the upper 95% confidence intervals). No differences in %E(2) were observed between VCV and PCV, at comparable Vt and PEEP levels, when flow-dependencies were included in the regression model. The negligence of the flow-dependent parameter systematically led to an underestimation of %E(2) in PCV compared to VCV mode (all P < 0.02). At a given Vt, %E(2) was negative at a PEEP of 0 cm H(2)O and significantly increased with PEEP, being almost 0 at a PEEP of 5 cm H(2)O. At a given level of PEEP, %E(2) significantly increased with Vt. CONCLUSIONS: The distension index %E(2), derived from the VDSCM considering flow-dependencies, seems able to identify tidal recruitment/overdistension induced by Vt and PEEP independent of flow waveform in healthy lung-anesthetized patients.


Asunto(s)
Anestesia General/métodos , Pulmón/fisiología , Respiración con Presión Positiva/métodos , Respiración Artificial/métodos , Volumen de Ventilación Pulmonar/fisiología , Anestesia General/efectos adversos , Femenino , Humanos , Respiración Artificial/efectos adversos , Volumen de Ventilación Pulmonar/efectos de los fármacos
14.
Lung ; 189(6): 499-509, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21952833

RESUMEN

BACKGROUND: We studied the occurrence of intraoperative tidal alveolar recruitment/derecruitment, exhaled nitric oxide (eNO), and lung dysfunction in patients with and without chronic obstructive pulmonary disease (COPD) undergoing coronary artery bypass grafting (CABG). METHODS: We performed a prospective observational physiological study at a university hospital. Respiratory mechanics, shunt, and eNO were assessed in moderate COPD patients undergoing on-pump (n = 12) and off-pump (n = 8) CABG and on-pump controls (n = 8) before sternotomy (baseline), after sternotomy and before cardiopulmonary bypass (CPB), and following CPB before and after chest closure. Respiratory system resistance (R (rs)), elastance (E (rs)), and stress index (to quantify tidal recruitment) were estimated using regression analysis. eNO was measured with chemiluminescence. RESULTS: Mechanical evidence of tidal recruitment/derecruitment (stress index <1.0) was observed in all patients, with stress index <0.8 in 29% of measurements. Rrs in on-pump COPD was larger than in controls (p < 0.05). Ers increased in controls from baseline to end of surgery (19.4 ± 5.5 to 27.0 ± 8.5 ml cm H(2)O(-1), p < 0.01), associated with increased shunt (p < 0.05). Neither Ers nor shunt increased significantly in the COPD on-pump group. eNO was comparable in the control (11.7 ± 7.0 ppb) and COPD on-pump (9.9 ± 6.8 ppb) groups at baseline, and decreased similarly by 29% at end of surgery(p < 0.05). Changes in eNO were not correlated to changes in lung function. CONCLUSIONS: Tidal recruitment/derecruitment occurs frequently during CABG and represents a risk for ventilator-associated lung injury. eNO changes are consistent with small airway injury, including that from tidal recruitment injury. However, those changes are not correlated with respiratory dysfunction. Controls have higher susceptibility to develop complete lung derecruitment.


Asunto(s)
Puente de Arteria Coronaria , Espiración/fisiología , Óxido Nítrico/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Mecánica Respiratoria/fisiología , Anciano , Anciano de 80 o más Años , Pruebas Respiratorias , Estudios de Casos y Controles , Femenino , Cardiopatías/cirugía , Humanos , Pulmón/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intercambio Gaseoso Pulmonar/fisiología , Análisis de Regresión , Estudios Retrospectivos , Estrés Fisiológico/fisiología , Volumen de Ventilación Pulmonar/fisiología
15.
Biomed Eng Online ; 9: 36, 2010 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-20673339

RESUMEN

BACKGROUND: The positive end-expiratory pressure (PEEP) for the mechanical ventilation of small animals is frequently obtained with water seals or by using ventilators developed for human use. An alternative mechanism is the use of an on-off expiratory valve closing at the moment when the alveolar pressure is equal to the target PEEP. In this paper, a novel PEEP controller (PEEP-new) and the PEEP system of a commercial small-animal ventilator, both based on switching an on-off valve, are evaluated. METHODS: The proposed PEEP controller is a discrete integrator monitoring the error between the target PEEP and the airways opening pressure prior to the onset of an inspiratory cycle. In vitro as well as in vivo experiments with rats were carried out and the PEEP accuracy, settling time and under/overshoot were considered as a measure of performance. RESULTS: The commercial PEEP controller did not pass the tests since it ignores the airways resistive pressure drop, resulting in a PEEP 5 cmH2O greater than the target in most conditions. The PEEP-new presented steady-state errors smaller than 0.5 cmH2O, with settling times below 10 s and under/overshoot smaller than 2 cmH2O. CONCLUSION: The PEEP-new presented acceptable performance, considering accuracy and temporal response. This novel PEEP generator may prove useful in many applications for small animal ventilators.


Asunto(s)
Tamaño Corporal , Respiración con Presión Positiva/instrumentación , Ventiladores Mecánicos , Animales , Espiración , Ratas , Ratas Sprague-Dawley , Reproducibilidad de los Resultados , Factores de Tiempo
16.
Ann Biomed Eng ; 38(3): 993-1006, 2010 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-20012694

RESUMEN

It is an accepted hypothesis that the amplitude of the respiratory-related oscillations of arterial partial pressure of oxygen (DeltaPaO2) is primarily modulated by fluctuations of pulmonary shunt (Deltas), the latter generated mainly by cyclic alveolar collapse/reopening, when present. A better understanding of the relationship between DeltaPaO2, Deltas, and cyclic alveolar collapse/reopening can have clinical relevance for minimizing the severe lung damage that the latter can cause, for example during mechanical ventilation (MV) of patients with acute lung injury (ALI). To this aim, we numerically simulated the effect of such a relationship on an animal model of ALI under MV, using a combination of a model of lung gas exchange during tidal ventilation with a model of time dependence of shunt on alveolar collapse/opening. The results showed that: (a) the model could adequately replicate published experimental results regarding the complex dependence of DeltaPaO2 on respiratory frequency, driving pressure (DeltaP), and positive end-expiratory pressure (PEEP), while simpler models could not; (b) such a replication strongly depends on the value of the model parameters, especially of the speed of alveolar collapse/reopening; (c) the relationship between DeltaPaO2 and Deltas was overall markedly nonlinear, but approximately linear for PEEP>or=6 cmH2O, with very large DeltaPaO2 associated with relatively small Deltas.


Asunto(s)
Lesión Pulmonar Aguda/fisiopatología , Lesión Pulmonar Aguda/rehabilitación , Relojes Biológicos , Modelos Biológicos , Oxígeno/metabolismo , Circulación Pulmonar , Respiración Artificial , Mecánica Respiratoria , Animales , Simulación por Computador , Modelos Animales de Enfermedad , Oscilometría/métodos , Conejos
17.
Intensive Care Med ; 34(12): 2291-9, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18825365

RESUMEN

OBJECTIVE: To evaluate the ability of three indices derived from the airway pressure curve for titrating positive end-expiratory pressure (PEEP) to minimize mechanical stress while improving lung aeration assessed by computed tomography (CT). DESIGN: Prospective, experimental study. SETTING: University research facilities. SUBJECTS: Twelve pigs. INTERVENTIONS: Animals were anesthetized and mechanically ventilated with tidal volume of 7 ml kg(-1). In non-injured lungs (n = 6), PEEP was set at 16 cmH(2)O and stepwise decreased until zero. Acute lung injury was then induced either with oleic acid (n = 6) or surfactant depletion (n = 6). A recruitment maneuver was performed, the PEEP set at 26 cmH(2)O and decreased stepwise until zero. CT scans were obtained at end-expiratory and end-inspiratory pauses. The elastance of the respiratory system (Ers), the stress index and the percentage of volume-dependent elastance (%E (2)) were estimated. MEASUREMENTS AND MAIN RESULTS: In non-injured and injured lungs, the PEEP at which Ers was lowest (8-4 and 16-12 cmH(2)O, respectively) corresponded to the best compromise between recruitment/hyperinflation. In non-injured lungs, stress index and %E (2) correlated with tidal recruitment and hyperinflation. In injured lungs, stress index and %E (2) suggested overdistension at all PEEP levels, whereas the CT scans evidenced tidal recruitment and hyperinflation simultaneously. CONCLUSION: During ventilation with low tidal volumes, Ers seems to be useful for guiding PEEP titration in non-injured and injured lungs, while stress index and %E (2) are useful in non-injured lungs only. Our results suggest that Ers can be superior to the stress index and %E (2) to guide PEEP titration in focal loss of lung aeration.


Asunto(s)
Lesión Pulmonar Aguda/fisiopatología , Respiración con Presión Positiva/efectos adversos , Lesión Pulmonar Aguda/prevención & control , Animales , Análisis de los Gases de la Sangre , Modelos Animales de Enfermedad , Femenino , Modelos Biológicos , Pruebas de Función Respiratoria , Sus scrofa
19.
Med Biol Eng Comput ; 46(1): 69-73, 2008 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-17932699

RESUMEN

To assess the impact of the endotracheal tube (ETT) and of different flow waveforms on estimates of alveolar cyclic recruitment (CR) and overdistension (AO). Numerical simulation of the respiratory system plus ETT (inertance L plus a flow-dependent resistance, K (1) and K (2)), with the following non-linear equation of motion PAW(t)= ((K1 + K2 x/V(t)/) x V(t) + L x V(t)) + Rrs x V(t) + (E1 + E2 x V(t) x V(t) + P0 (PAW pressure at the airways opening, V volume), under volume-controlled mechanical ventilation. An index %E2 = 100 x (E2 x V(T))/(E1 + E2)x V(T)) can be calculated where %E(2) > 30% represents AO and %E(2) < 0% represents CR. Parameters were estimated by the least-squares method, either with the complete equation or suppressing L, K(2) or both. %E(2) is always underestimated (down to -152 percent points) with incomplete equations of motion. The estimation of %E (2) may be strongly biased in the presence of an ETT excluded from the estimation model.


Asunto(s)
Intubación Intratraqueal/instrumentación , Modelos Biológicos , Respiración Artificial/instrumentación , Humanos , Rendimiento Pulmonar/fisiología , Mecánica Respiratoria/fisiología
20.
Crit Care ; 11(4): R86, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17688701

RESUMEN

INTRODUCTION: Protective ventilatory strategies have been applied to prevent ventilator-induced lung injury in patients with acute lung injury (ALI). However, adjustment of positive end-expiratory pressure (PEEP) to avoid alveolar de-recruitment and hyperinflation remains difficult. An alternative is to set the PEEP based on minimizing respiratory system elastance (Ers) by titrating PEEP. In the present study we evaluate the distribution of lung aeration (assessed using computed tomography scanning) and the behaviour of Ers in a porcine model of ALI, during a descending PEEP titration manoeuvre with a protective low tidal volume. METHODS: PEEP titration (from 26 to 0 cmH2O, with a tidal volume of 6 to 7 ml/kg) was performed, following a recruitment manoeuvre. At each PEEP, helical computed tomography scans of juxta-diaphragmatic parts of the lower lobes were obtained during end-expiratory and end-inspiratory pauses in six piglets with ALI induced by oleic acid. The distribution of the lung compartments (hyperinflated, normally aerated, poorly aerated and non-aerated areas) was determined and the Ers was estimated on a breath-by-breath basis from the equation of motion of the respiratory system using the least-squares method. RESULTS: Progressive reduction in PEEP from 26 cmH2O to the PEEP at which the minimum Ers was observed improved poorly aerated areas, with a proportional reduction in hyperinflated areas. Also, the distribution of normally aerated areas remained steady over this interval, with no changes in non-aerated areas. The PEEP at which minimal Ers occurred corresponded to the greatest amount of normally aerated areas, with lesser hyperinflated, and poorly and non-aerated areas. Levels of PEEP below that at which minimal Ers was observed increased poorly and non-aerated areas, with concomitant reductions in normally inflated and hyperinflated areas. CONCLUSION: The PEEP at which minimal Ers occurred, obtained by descending PEEP titration with a protective low tidal volume, corresponded to the greatest amount of normally aerated areas, with lesser collapsed and hyperinflated areas. The institution of high levels of PEEP reduced poorly aerated areas but enlarged hyperinflated ones. Reduction in PEEP consistently enhanced poorly or non-aerated areas as well as tidal re-aeration. Hence, monitoring respiratory mechanics during a PEEP titration procedure may be a useful adjunct to optimize lung aeration.


Asunto(s)
Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/fisiopatología , Síndrome de Dificultad Respiratoria/terapia , Animales , Modelos Animales de Enfermedad , Ácido Oléico , Síndrome de Dificultad Respiratoria/metabolismo , Mecánica Respiratoria , Estrés Mecánico , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...