Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 158
Filtrar
1.
Oper Dent ; 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632862

RESUMEN

OBJECTIVES: The depth of cure using blue-light photocuring units (BL) is limited by tooth structure and qualities of the restorative material through which the activating wavelength must pass. Recent developments incorporate an infrared (IR) activated upconversion (UC) fluorescence of a lining agent filled with nanocrystals of NaYF4 and doped with YB+3 and Tm+3 that emit both blue and violet light locally at the interface of the liner and restorative resin. The purpose of this study was to evaluate the BL and 975 nm infrared (IR) light power transmission through dental tissues and restorative materials. METHODS AND MATERIALS: Power transmissions of the IR laser (975 nm) and a monowave blue-only light-curing unit (Bluephase 16i) through dental tissues (enamel, dentin, and enamel/dentin junction, or DEJ), eight (8) various dental resin composites, and eight (8) dental ceramics, each at four thicknesses (1, 2, 3 and 4 mm) were evaluated (n=5) using a thermopile sensor (PM10, Coherent Inc) connected to a laser power meter (Fieldmate, Coherent Inc). Power transmission values of each light source and restorative material were subjected to analysis of variance and Tukey test at a pre-set alpha of 0.05. RESULTS: A linear correlation (r=0.9884) between the supplied current and emitted IR power of the laser diode was found, showing no statistical power reduction with increased distances (collimated beam). For tooth tissues, the highest power transmissions for both light sources were observed using 1.0 mm enamel while the lowest values were found for 2.0 mm dentin and an association of 2.0 mm DEJ and 1.0 mm dentin. The only group where IR demonstrated significantly higher transmission when compared to BL was 1.0 mm enamel. For all resin composites and dental ceramics, increased thickness resulted in a reduction of IR power transmission (except for EverX Posterior fiber-reinforced composite and e.max HT ceramic). IR resulted in higher transmission through all resin composites, except for Tetric EvoCeram White. The highest BL transmission was observed for SDR Flow, at all thicknesses. Higher IR/BL ratios were observed for EverX Posterior, Herculite Ultra, and Lava Ultimate, while the lowest ratio was observed for Tetric EvoCeram White. Reduced translucency shades within the same material resulted in lower power ratio values, especially for BL transmission. Higher IR/BL ratios were observed for e.Max LT, VitaVM7 Base Dentin, and e.max CAD HT, while the lowest values were found for VitaVM7 Enamel and Paradigm C. CONCLUSION: IR power transmission through enamel was higher when compared to blue light, while no difference was observed for dentin. The power transmission of IR was higher than BL for resin composites, except for a high value and low chroma shade. Fiber-reinforced resin composite demonstrated the highest IR/BL power transmission ratio. A greater IR/BL ratio was observed for lower translucency ceramics when compared to high translucency.

2.
Oper Dent ; 48(3): 277-293, 2023 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-36929774

RESUMEN

The objective of this study was to investigate the effect of surface treatments in maximum profile valley depth (Rv), surface roughness (Sa), contact angle (Ca), shear bond strength (SBS) of a light-cured resin cement, microstructure, and composition of two CAD/CAM ceramics: Cerec Blocs/Dentsply Sirona (feldspathic - FEL) and Empress CAD/Ivoclar Vivadent (leucite-reinforced - LEU). The ceramic specimens were submitted to six surface treatments: (1) 5% hydrofluoric acid (HF) - 20 seconds; (2) 5% HF - 60 seconds; (3) 10% HF - 20 seconds; (4) 10% HF - 60 seconds; (5) self-etching ceramic primer (MEP) - 20 seconds; and (6) MEP - 60 seconds. Specimens treated with HF received silane application for 1 minute. Rv and Sa were evaluated in a confocal laser microscope (n=10) and the Ca in a goniometer (n=6). For the SBS test, two resin cement cylinders were bonded to each specimen, one tested after 24 hours in distilled water storage (37°C) and the other after one year (n=10). The microstructures and compositions were analyzed by scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) (n=4). Rv, Sa, and Ca data were analyzed by two-way ANOVA, and the SBS data by three-way ANOVA, all followed by post-hoc Tukey's test (α=0.05). Results: Surface treatments with HF always produced higher Rv and Sa, and lower Ca than MEP 60s for both ceramics. After 1-year water storage, FEL ceramic treated with MEP for 60 seconds produced higher SBS values than HF treatments, whereas for LEU ceramic there were no differences among treatments. Application of MEP for 20 or 60 seconds produced no difference in Rv, Sa, Ca, and SBS for both ceramics. Surface treatments produced considerable differences in ceramic topography, but subtle ones in composition, for both ceramics. Conclusions: The results indicated that for FEL ceramic, MEP application for 60 seconds yielded higher SBS compared with HF etching, while for LEU ceramic the surface treatments did not influence the SBS results.


Asunto(s)
Recubrimiento Dental Adhesivo , Porcelana Dental , Cementos de Resina/uso terapéutico , Cerámica/química , Resistencia al Corte , Ácido Fluorhídrico , Propiedades de Superficie , Ensayo de Materiales , Silanos
3.
Inflamm Res ; 72(5): 895-899, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36917217

RESUMEN

OBJECTIVE: To evaluate whether colchicine treatment was associated with the inhibition of NLRP3 inflammasome activation in patients with COVID-19. METHODS: We present a post hoc analysis from a double-blinded placebo-controlled randomized clinical trial (RCT) on the effect of colchicine for the treatment of COVID-19. Serum levels of NOD-like receptor protein 3 (NLRP3) inflammasome products-active caspase-1 (Casp1p20), IL-1ß, and IL-18-were assessed at enrollment and after 48-72 h of treatment in patients receiving standard-of-care (SOC) plus placebo vs. those receiving SOC plus colchicine. The colchicine regimen was 0.5 mg tid for 5 days, followed by 0.5 mg bid for another 5 days. RESULTS: Thirty-six patients received SOC plus colchicine, and thirty-six received SOC plus placebo. Colchicine reduced the need for supplemental oxygen and the length of hospitalization. On Days 2-3, colchicine lowered the serum levels of Casp1p20 and IL-18, but not IL-1ß. CONCLUSION: Treatment with colchicine inhibited the activation of the NLRP3 inflammasome, an event triggering the 'cytokine storm' in COVID-19. TRIAL REGISTRATION NUMBERS: RBR-8jyhxh.


Asunto(s)
COVID-19 , Inflamasomas , Humanos , Inflamasomas/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Interleucina-18 , Proteínas NLR , Colchicina/uso terapéutico , Interleucina-1beta/metabolismo
4.
Oper Dent ; 48(1): 51-58, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36534034

RESUMEN

PURPOSE: To evaluate the effect of short curing time using a high-radiant emittance light on polymerization shrinkage vectors in different consistency bulk-fill composites (BFRCs) using micro-computed tomography. METHODS AND MATERIALS: Radiopaque zirconia fillers were homogeneously incorporated and functioned as radiopaque tracers into two regular-paste: TBFill (Tetric EvoCeram Bulk Fill) and TPFill (Tetric PowerFill), and two flowable (n=6): TBFlow (Tetric EvoFlow Bulk Fill) and TPFlow (Tetric PowerFlow) resin composites. Class I cavities (4 mm depth × 4 mm length × 4 mm width) were 3D-printed and filled in a single increment: TBFill and TBFlow were light-activated using a Bluephase Style 20i (10 seconds in high-mode); TPFill and TPFlow were light-activated using a Bluephase PowerCure (three seconds). The same adhesive system (Adhese Universal) was used for all groups. Microcomputed tomography scans were obtained before and after light-activation. Filler particle movement was identified by polymerization shrinkage vectors at five depths (from 0-4 mm): top, top-middle, middle, middle-bottom and bottom. RESULTS: TPFlow showed the lowest total vector displacement, followed by TBFlow, TBFill and TPFill, significantly different among each other (p<0.05). Generally, BFRCs showed decreased vector displacement with increased depth, and higher displacement at the top-surface (p<0.05). Qualitative analysis showed a similar pattern of vector magnitude and displacement for groups TBFill and TPFill, with displacement vectors on occlusal (top) surfaces toward the center of the restoration from the top to middle areas, and relatively limited displacement at the bottom. TBFlow and TPFlow showed more displacement on the occlusal (top). CONCLUSIONS: Short curing time with high-radiant emittance on fast-curing BFRCs was shown to be a feasible option in terms of vector displacement. Flowable BFRCs presented lower vector displacement than their regular-viscosity versions.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Microtomografía por Rayos X , Polimerizacion , Ensayo de Materiales , Curación por Luz de Adhesivos Dentales
5.
Oper Dent ; 47(1): 55-63, 2022 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35584286

RESUMEN

OBJECTIVES: To evaluate the effect of argon plasma treatment (PLA) when combined with sandblasting (SAN), silanization (SIL), and hydrophobic bonding resin (HBR) on the shear bond strength (SBS) of a two-year water-aged resin composite bonded to a newly placed composite after 24 hours and one year of water-storage. METHODS AND MATERIALS: Thirty-six light-cured composite plates (20mm x 20mm x 4mm thick) were obtained and stored at 37°C in distilled water for 2 years. These aged plates were distributed into 6 groups (n=6) according to the surface treatment: no treatment (Negative Control); SAN+SIL+HBR (Positive Control); SAN+PLA+SIL+HBR; PLA+ SIL+HBR; PLA+SIL; PLA+HBR. Fresh resin composite cylinders were built up using silicone molds (hole: 1.5 mm high x 1.5 mm diameter) positioned over the aged plates. Half of the SBS samples were stored in distilled water for 24 hours and loaded until failure, while the other half were stored for 1 year before being tested. Data were submitted to two-way analysis of variance and post-hoc Tukey Test (preset alpha of 0.05). RESULTS: Positive Control, SAN+PLA+SIL+HBR and PLA+SIL+HBR groups presented higher SBS means at the 24 hour evaluation. After 1 year of water storage, all groups demonstrated significant SBS reduction, with the SAN+PLA+SIL+HBR group presenting the highest SBS. CONCLUSIONS: Resin plasma treatment in combination with other surface treatments can improve the SBS of composite repairs after one year of water storage. The SBS of the composite repair was not stable over time regardless of the surface treatment.


Asunto(s)
Recubrimiento Dental Adhesivo , Gases em Plasma , Argón , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Ensayo de Materiales , Gases em Plasma/uso terapéutico , Poliésteres , Cementos de Resina/química , Resistencia al Corte , Propiedades de Superficie , Agua/química
6.
Oper Dent ; 46(3): E158-E170, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34662908

RESUMEN

This study evaluated intrapulpal concentration and hydrogen peroxide (HP) penetration at the interface of teeth restored with bioactive composites, using conventional or bulk-fill composites. Cylindrical cavities were prepared on the buccal surface of bovine incisor crowns (n=20) and restored with: resin modified glass-ionomer (RMGI, Riva Light Cure, SDI), non-bioactive bulk-fill composite (FB, Filtek Bulk, 3M Oral Care), non-bioactive conventional composite (FZ, Filtek Z350, 3M Oral Care), bioactive bulk-fill composite (AC, Activa BioActive, Pulpedent), and bioactive conventional composite (BII, Beautifil II, Shofu). After 5,000 thermal cycles, restorations (n=10) were exposed to high (35% HP [4 applications of 8 min/session-4 sessions]) or low (9.5% HP [30 min/day-14 days]) concentration bleaching protocols. After the last bleaching application, the HP intrapulpal concentration was determined. Additional teeth were restored, pigmented with rhodamine B solution, and HP penetration around the interface was observed under laser scanning confocal fluorescence microscopy (LSCFM, n=3). The presence of gaps at the interface was observed on replicas of the cross-sectioned samples under scanning electron microscopy (SEM, n=5). Data were submitted to one-way (gap analysis) and twoway analysis of variance (ANOVA; HP intrapulpal concentration) and Tukey test (α=0.05). The LSCFM images were qualitatively analyzed. The restored teeth submitted to 35% HP presented higher HP intrapulpal concentration than teeth submitted to 9.5% HP (p<0.05). No differences in HP intrapulpal concentration was observed among groups (p>0.05) when exposed to 9.5% HP. Lower HP intrapulpal concentration was observed for teeth restored with RMGI exposed to HP 35%, when compared with teeth restored with nonbioactive conventional (FZ; p=0.004) and bulk-fill composites (FB; p=0.01). No gap formation was observed at the outer enamel adhesive interface for all restorative materials. LSCFM images showed that 35% HP promoted greater degradation of rhodamine B at the enamel, except for RMGI. In this context, RMGI promoted lower HP intrapulpal concentration than non-bioactive conventional and bulk-fill composites.


Asunto(s)
Restauración Dental Permanente , Peróxido de Hidrógeno , Animales , Bovinos , Esmalte Dental , Materiales Dentales , Ensayo de Materiales
7.
Oper Dent ; 45(5): E237-E254, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32516376

RESUMEN

CLINICAL RELEVANCE: According to the clinical and scientific evidence presented in this systematic review and meta-analysis, dental adhesives containing either organic solvent (acetone or alcohol) can be used to achieve similar clinical performance and longevity of composite restorations. SUMMARY: Objectives: This systematic review and meta-analysis compared the clinical performance and survival rates of composite restorations placed in noncarious cervical lesions (NCCLs) using dental adhesives containing acetone or alcohol-based solvents.Methods and Materials: PubMed, Scopus, Web of Science, Virtual Health Library (VHL) LILACS, Cochrane Library, OpenGrey, Clinical Trials, and Rebec were searched. MeSH terms, supplementary concepts, synonyms, and free keywords were used in the search strategy. All references were crosschecked by two independent investigators following the PICOS strategy (population, NCCLs; intervention, acetone-based bonding agent; comparison, alcohol-based bonding agent; outcome, clinical evaluation parameters and survival rates; study design, randomized controlled clinical trials). Cochrane Collaboration's tool was used to assess risk of bias, and two distinct meta-analyses were performed using the RevMan software. The prevalence of success and the total number of restorations for each group (acetone- or alcohol-based) were used to calculate the risk difference at a confidence interval of 95%. Random-effects models were applied, and heterogeneity was assessed using the I2 index in the pooled and subgrouped meta-analyses. The certainty of evidence was evaluated through the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach.Results: A total of 7876 studies were retrieved, from which 27 studies were selected for the systematic review. Ten studies were classified as "low risk of bias" and included in the meta-analyses. Overall heterogeneity was not significant (I2 = 0.00%). The clinical performance of restorations placed with bonding agents based on both solvents for each of the available parameters presented no statistical significance for any of the meta-analyses (p>0.05).Conclusion: Scientific evidence suggests composite restorations placed with acetone or alcohol-based dental adhesives present similar clinical performance and survival rates in NCCLs.


Asunto(s)
Restauración Dental Permanente , Cuello del Diente , Resinas Compuestas , Cementos Dentales , Solventes
8.
Oper Dent ; 45(4): E167-E175, 2020 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-32216725

RESUMEN

CLINICAL RELEVANCE: Secondary caries are the main reason for the failure of restorations, class II being the most affected. Techniques that promote less gap percentage are important. Flowable bulk fill composites used at such locations have been shown to decrease gap formation while being a faster procedure than an incremental technique.


Asunto(s)
Caries Dental , Restauración Dental Permanente , Resinas Compuestas , Adaptación Marginal Dental , Humanos , Microtomografía por Rayos X
9.
Oper Dent ; 45(5): 496-505, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32101499

RESUMEN

CLINICAL RELEVANCE: Shortened light curing does not affect volumetric polymerization shrinkage or cohesive tensile strength but negatively affects the shear bond strength of some bulk-fill resin composites. When performing shortened light curing, clinicians should be aware of the light output of their light-curing units. SUMMARY: Purpose: To evaluate volumetric polymerization shrinkage (VPS), shear bond strength (SBS) to dentin, and cohesive tensile strength (CTS) of bulk-fill resin composites (BFRCs) light activated by different modes.Methods and Materials: Six groups were evaluated: Tetric EvoCeram bulk fill + high mode (10 seconds; TEC H10), Tetric EvoFlow bulk fill + high mode (TEF H10), experimental bulk fill + high mode (TEE H10), Tetric EvoCeram bulk fill + turbo mode (five seconds; TEC T5), Tetric EvoFlow bulk fill + turbo mode (TEF T5), and experimental bulk fill + turbo mode (TEE T5). Bluephase Style 20i and Adhese Universal Vivapen were used for all groups. All BFRC samples were built up on human molar bur-prepared occlusal cavities. VPS% and location were evaluated through micro-computed tomography. SBS and CTS tests were performed 24 hours after storage or after 5000 thermal cycles; fracture mode was analyzed for SBS.Results: Both TEC H10 and TEE H10 presented lower VPS% than TEF H10. However, no significant differences were observed with the turbo-curing mode. No differences were observed for the same BFRC within curing modes. Occlusal shrinkage was mostly observed. Regarding SBS, thermal cycling (TC) affected all groups. Without TC, all groups showed higher SBS values for high mode than turbo mode, while with TC, only TEC showed decreased SBS from high mode to turbo modes; modes of fracture were predominantly adhesive. For CTS, TC affected all groups except TEE H10. In general, no differences were observed between groups when comparing the curing modes.Conclusions: Increased light output with a shortened curing time did not jeopardize the VPS and SBS properties of the BFRCs, although a decreased SBS was observed in some groups. TEE generally showed similar or improved values for the tested properties in a shortened light-curing time. The VPS was mostly affected by the materials tested, whereas the SBS was affected by the materials, curing modes, and TC. The CTS was not affected by the curing modes.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Humanos , Curación por Luz de Adhesivos Dentales , Ensayo de Materiales , Diente Molar , Polimerizacion , Resistencia al Corte , Microtomografía por Rayos X
10.
Oper Dent ; 45(3): E141-E155, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32053458

RESUMEN

OBJECTIVES: This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. METHODS AND MATERIALS: Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (α=0.05). RESULTS: The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric EvoCeram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. CONCLUSIONS: Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Resinas Compuestas , Materiales Dentales , Dureza , Humanos , Ensayo de Materiales , Diente Molar , Polimerizacion , Propiedades de Superficie
11.
Oper Dent ; 45(3): 327-338, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31794346

RESUMEN

This study evaluated the effect of light curing unit (LCU) guide type (regular or homogenizing) on top and bottom microhardness of conventional and bulk-fill resin-based composites (RBCs). A polywave light-emitting-diode (LED) LCU (Bluephase Style, Ivoclar Vivadent AG) was used with two different light guides: a regular tip (RT, 935 mW/cm2 emittance) and a homogenizer tip (HT, 851 mW/cm2 emittance). Two conventional RBCs (Herculite Ultra [HER], Kerr Corp; Tetric EvoCeram [TEC], Ivoclar Vivadent AG) and two bulk-fill RBCs (SonicFill [SOF], Kerr Corp; Tetric EvoCeram Bulk Fill [TBF], Ivoclar Vivadent AG) were tested. Disc-shaped samples (10 mm Ø), 2-mm thick for conventional composites and 4-mm thick for bulk-fill composites were prepared. Samples were light cured according to manufacturer-recommended times. Knoop microhardness values (KHN) were obtained on the top and bottom surfaces of each specimen at locations correlated with the output of the three LED chips emitting blue (456 nm) or violet light (409 nm). Beam profile analysis using both light guides was also performed. Microhardness of each composite was analyzed using three-way analysis of variance and Tukey honestly significant difference post hoc test (α=0.05). Beam profile images showed better light distribution across the surface of the HT light guide. Use of the HT decreased KHN of HER at the locations of the blue LED chips at bottom of the sample but had no effect on the top surface. For TEC, use of HT increased KHN of all three LED locations at the top surface. Use of the HT increased KHN of SOF at locations corresponding to one of the blue and the violet LED chips at the bottom surface. For TBF, HT increased KHN at all top surface locations. All RBCs showed higher mean KHN at the top compared with the bottom surfaces. In general, all composites presented a higher KHN at the blue LED areas regardless of the surface or the tip used. Results suggest that the homogenizer light guide resulted in significantly increased microhardness at the top, in composite resins containing alternative photoinitiators; however, that effect was not observed at the bottom surfaces.


Asunto(s)
Luces de Curación Dental , Curación por Luz de Adhesivos Dentales , Resinas Compuestas , Materiales Dentales , Dureza , Ensayo de Materiales , Polimerizacion , Propiedades de Superficie
12.
J Dent Res ; 98(7): 779-785, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31050913

RESUMEN

A novel filler-resin matrix interphase structure was developed and evaluated for dental composite restoratives. Nanogel additives were chemically attached to the filler surface to use this created interphase as a potential source of compliance to minimize stress development during polymerization. In addition, we evaluated the effects of free nanogel dispersion into the resin matrix, combined or not with nanogel-modified fillers. Nanogels with varied characteristics were synthesized (i.e., size, 5 and 11 nm; glass transition temperature, 28 °C to 65 °C). Glass fillers were treated with trimethoxyvinylsilane and further reacted with thiol-functionalized nanogels via a free radical thiol-ene reaction. γ-Methacryloxypropyltrimethoxysilane-surface treated fillers were used as a control. Composites were formulated with BisGMA/TEGDMA resin blend with 60 wt% fillers with nanogel-modified fillers and/or free nanogel additives at 15 wt% in the resin phase. Polymerization kinetics, polymerization stress, volumetric shrinkage, and rheological and mechanical properties were evaluated to provide comprehensive characterization. Nanogel-modified fillers significantly reduced the polymerization stress from 2.2 MPa to 1.7 to 1.4 MPa, resulting in 20% stress reduction. A significantly greater nanogel content was required to generate the same magnitude stress reduction when the nanogels were dispersed only in the resin phase. When the nanogel-modified filler surface treatment and resin-dispersed nanogel strategies were combined, there was a stress reduction of 50% (values of 1.2 to 1.1 MPa). Polymerization rate and volumetric shrinkage were significantly reduced for systems with nanogel additives into the resin. Notably, the flexural modulus of the materials was not compromised, although a slight reduction in flexural strength associated with the nanogel-modified interphase was observed. Overall, modest amounts of free nanogel additives in the resin phase can be effectively combined with a limited nanogel content filler-resin interphase to lower volumetric shrinkage and dramatically reduce overall polymerization stress of composites.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Nanogeles , Ensayo de Materiales , Metacrilatos , Docilidad , Polimerizacion , Ácidos Polimetacrílicos , Estrés Mecánico , Propiedades de Superficie
13.
Oper Dent ; 44(2): E75-E82, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30888926

RESUMEN

OBJECTIVES:: This study evaluated the effect of argon plasma treatment (PLA) and its combination with sandblasting (SAN), silanization (SIL), and hydrophobic bonding resin (HBR) application on the micro-shear bond strength of water-aged restorative resin composite to a newly placed composite, simulating restoration repair. METHODS AND MATERIALS:: Forty-five light-cured composite plates (20-mm long × 20-mm wide × 4-mm thick) were fabricated using a hybrid composite and stored at 37°C in distilled water for six months. The aged composite surfaces were treated according to the following experimental groups, varying both treatment and order of application: 1) SAN + SIL + HBR (control), 2) SAN + PLA for 30 seconds + SIL + HBR, 3) SAN + SIL + PLA + HBR, 4) PLA + SIL + HBR, 5) PLA + SIL, 6) PLA + HBR, 7) SIL + PLA + HBR, 8) SIL + PLA, and 9) PLA. After the surface treatments, four fresh resin composite cylinders (1.5-mm high × 1.5-mm diameter) of the same composite were built on each aged composite surface using a silicone mold. After water storage for 24 hours or one year, the specimens were submitted to shear bond strength testing. Data were statistically analyzed by two-way analysis of variance and Tukey's test (5%). RESULTS:: Groups 1, 2, and 4 presented significantly higher bond strength means at 24 hours, although group 4 did not differ from group 7. Groups 5, 8, and 9 demonstrated significantly lower means than the other groups. Even though groups 1 and 2 had a significant bond strength reduction after 1 year, they still demonstrated higher bond strength at one year of storage. CONCLUSIONS:: While PLA application combined with surface treatment methods demonstrated high bond strength results, this treatment alone was not as beneficial as other methods that included SAN, SIL and HBR.


Asunto(s)
Recubrimiento Dental Adhesivo , Gases em Plasma , Argón , Resinas Compuestas , Ensayo de Materiales , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie
14.
Oper Dent ; 44(6): 637-647, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30702404

RESUMEN

OBJECTIVES: This study evaluated the effect of toothbrushing with a dentifrice on gloss, roughness profile, surface roughness, and wear of conventional and bulk-fill resin-based composites. METHODS AND MATERIALS: Gloss and surface roughness of resin-based composites (RBCs; Admira Fusion X-tra, Aura Bulk Fill, Filtek Bulk Fill Flowable, Filtek Bulk Fill Posterior Restorative, Filtek Supreme Ultra, Herculite Ultra, Mosaic Enamel, SDR flow+, Sonic Fill 2, Tetric EvoFlow Bulk Fill and Tetric EvoCeram Bulk Fill) were analyzed before and after brushing; the roughness profile and wear were also determined after toothbrushing. Representative three-dimensional images of the surface loss and images comparing the unbrushed and brushed surfaces were also compared. Analysis of variance and Tukey post hoc tests were applied (α=0.05) to the gloss, surface roughness, roughness profile, and surface loss data. Pearson's correlation test was used to determine the correlation between gloss and surface roughness, surface loss and percentage of gloss decrease after brushing, and surface loss and surface roughness after brushing. RESULTS: For all RBCs tested after 20,000 brushing cycles, the gloss was reduced and the surface roughness increased (p<0.05). However, the roughness profile and the amount of surface loss were dependent on the RBC brand. Admira Fusion X-tra, Aura, Tetric EvoCeram Bulk Fill, and Tetric EvoFlow Bulk Fill showed the deepest areas of wear (p<0.05). A significant negative correlation was found between gloss and surface roughness, and a weak correlation was found between the decrease in gloss and the extent of surface loss, and any increase in surface roughness and the surface loss. CONCLUSIONS: Toothbrushing with a dentifrice reduced the gloss, increased the surface roughness, and caused loss at the surface of all the RBCs tested. Considering all the properties tested, Mosaic Enamel exhibited excellent gloss retention and a low roughness profile and wear, while Admira Fusion X-tra exhibited the greatest decrease in gloss, the highest roughness profile, and the most wear.


Asunto(s)
Dentífricos , Cepillado Dental , Resinas Compuestas , Materiales Dentales , Ensayo de Materiales , Propiedades de Superficie
15.
Oper Dent ; 43(6): E288-E299, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30457947

RESUMEN

OBJECTIVES:: This study aimed to evaluate the influence of two nonthermal atmospheric plasma (NTAP) application times and two storage times on the microtensile bond strength (µTBS) to dentin. The influence of NTAP on the mechanical properties of the dentin-resin interface was studied by analyzing nanohardness (NH) and Young's modulus (YM). Water contact angles of pretreated dentin and hydroxyapatite blocks were also measured to assess possible alterations in the surface hydrophilicity upon NTAP. METHODS AND MATERIALS:: Forty-eight human molars were used in a split-tooth design (n=8). Midcoronal exposed dentin was flattened by a 600-grit SiC paper. One-half of each dentin surface received phosphoric acid conditioning, while the other half was covered with a metallic barrier and remained unetched. Afterward, NTAP was applied on the entire dentin surface (etched or not) for 10 or 30 seconds. The control groups did not receive NTAP treatment. Scotchbond Universal (SBU; 3M ESPE) and a resin-based composite were applied to dentin following the manufacturer's instructions. After 24 hours of water storage at 37°C, the specimens were sectioned perpendicular to the interface to obtain approximately six specimens or bonded beams (approximately 0.9 mm2 in cross-sectional area) representing the etch-and-rinse (ER) approach and another six specimens representing the self-etch (SE) approach. Half of the µTBS specimens were immediately loaded until failure, while the other half were first stored in deionized water for two years. Three other bonded teeth were selected from each group (n=3) for NH and YM evaluation. Water contact-angle analysis was conducted using a CAM200 (KSV Nima) goniometer. Droplet images of dentin and hydroxyapatite surfaces with or without 10 or 30 seconds of plasma treatment were captured at different water-deposition times (5 to 55 seconds). RESULTS:: Two-way analysis of variance revealed significant differences in µTBS of SBU to dentin after two years of water storage in the SE approach, without differences among treatments. After two years of water aging, the ER control and ER NTAP 10-second groups showed lower µTBS means compared with the ER NTAP 30-second treated group. Nonthermal atmospheric plasma resulted in higher NH and YM for the hybrid layer. The influence of plasma treatment in hydrophilicity was more evident in the hydroxyapatite samples. Dentin hydrophilicity increased slightly after 10 seconds of NTAP, but the difference was higher when the plasma was used for 30 seconds. CONCLUSIONS:: Dentin NTAP treatment for 30 seconds contributed to higher µTBS after two years of water storage in the ER approach, while no difference was observed among treatments in the SE evaluation. This result might be correlated to the increase in nanohardness and Young's modulus of the hybrid layer and to better adhesive infiltration, since dentin hydrophilicity was also improved. Although some effects were observed using NTAP for 10 seconds, the results suggest that 30 seconds is the most indicated treatment time.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo/métodos , Recubrimientos Dentinarios/química , Gases em Plasma/química , Grabado Ácido Dental , Materiales Dentales/química , Dentina , Dureza , Humanos , Técnicas In Vitro , Ensayo de Materiales , Diente Molar , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción
16.
Oper Dent ; 43(5): E253-E265, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30183535

RESUMEN

OBJECTIVES: To characterize the chemical interactions and analyze the interface of adhesive systems containing 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) and N-methacryloyl glycine (methacrylamide) functional monomers with the dentin in noncarious cervical lesions (NCCLs) compared with artificial defects (ADs). METHODS AND MATERIALS: Twenty human teeth with natural NCCLs on the buccal surface were used. Class V cavities, similar to NCCLs, were created on the lingual surface to serve as controls. Teeth were randomly allocated to two groups according to the functional monomer in the adhesive (N=10): G1, 10-MDP; and G2, methacrylamide. NCCLs and ADs were characterized by their mineral composition (MC) and degree of demineralization (DD) using micro-Raman spectroscopy, adhesive/dentin chemical interactions (CIs) were assessed with infrared photoacoustic spectroscopy, and interface morphology was evaluated with scanning electron and light microscopy. MC, CI, and DD data were submitted to Shapiro-Wilk and Student t-tests ( p<0.05). RESULTS: Compared with ADs, dentin in NCCLs was hypermineralized ( p<0.05). In G1, CI, and DD in the first 2 µm, and adhesive projections in NCCLs and ADs interfaces were similar. Additionally, a thin layer of dentin collagen was observed in ADs, while it was hardly present in NCCLs. In G2, although CI could not be identified, changes in the mineral components were observed. The DD in the ADs and NCCLs were statistically similar, while SEM showed a lack of adhesion at NCCLs interface. DD and collagen exposure in the ADs and NCCLs were more pronounced than in G1. CONCLUSIONS: Results suggest that the G1 adhesive could be applied directly on the superficial sclerotic layer in NCCLs. In contrast, previous cavity preparation should be conducted to improve the micromechanical interaction of G2 with the dentin.


Asunto(s)
Acrilamidas/uso terapéutico , Grabado Dental/métodos , Recubrimientos Dentinarios/uso terapéutico , Dentina/cirugía , Metacrilatos/uso terapéutico , Cuello del Diente/cirugía , Restauración Dental Permanente/métodos , Dentina/efectos de los fármacos , Dentina/metabolismo , Humanos , Técnicas In Vitro
17.
Oper Dent ; 43(4): 398-407, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29630482

RESUMEN

OBJECTIVES: This study evaluated the light output from six light-emitting diode dental curing lights after 25 consecutive light exposures without recharging the battery, tip accessibility in the posterior region, and light beam spread from light-curing units. METHODS: Irradiance, spectral peak, and radiant exposure were measured with the battery fully charged (Bluephase Style, ESPE Cordless, Elipar S10, Demi Ultra, Valo Cordless, and Radii-Cal) and monitored for 25 light exposures (each lasting 10 seconds). The tip diameter was measured to identify the beam size and the ability of the six light-curing units to irradiate all areas of the lower second molar in the standard output setting. RESULTS: Four curing lights delivered a single peak wavelength from 454 to 462 nm, and two (Bluephase Style and Valo Cordless) delivered multiple emission peaks (at 410 and 458 nm and 400, 450, and 460 nm, respectively). The irradiance and radiant exposure always decreased after 25 exposures by 2% to 8%, depending on the light unit; however, only ESPE Cordless, Valo Cordless, and Radii-Cal presented a statistical difference between the first and the last exposure. The tip diameter ranged from 6.77 mm to 9.40 mm. The Radii-Cal delivered the lowest radiant exposure and irradiance. This light was also unable to access all the teeth with the tip parallel to the occlusal surface of the tooth. CONCLUSION: Not all of the blue-emitting lights deliver the same emission spectra, and some curing lights delivered a lower irradiance (as much as 8% lower) after the 25th exposure.


Asunto(s)
Luces de Curación Dental , Suministros de Energía Eléctrica , Diseño de Equipo , Ensayo de Materiales
18.
Oper Dent ; 43(2): 144-150, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29394140

RESUMEN

OBJECTIVES: The aim of this study was to quantify the internal void volume formation in commercially available, resin composites inserted using conventional or sonic insertion methods, and analyzed using three-dimensional (3D) micro-computed tomography (µCT). METHODS AND MATERIALS: Four resin composites were evaluated: one conventional (Herculite, Ultra, Kerr Corporation, Orange, CA, USA), one flowable bulk fill (SureFil SDR Flow, Dentsply International, York, PA, USA), and two packable bulk fill (SonicFill, Kerr Corporation, and Tetric EvoCeram Bulk Fill, Ivoclar Vivadent Inc, Schaan, Liechtenstein). Eight groups were evaluated according to each resin composite type and insertion method (conventional or sonic; n=5). Forty ABS 3D-printed cylindrical molds, 5.0 mm in diameter and 4.0 mm in depth, were fabricated. For the conventional resin composite, the mold was filled incrementally (two layers), while for bulk-fill resin composites, insertion was performed in a single increment. The sonic insertion method was performed using a specific handpiece (SonicFill Handpiece, Kerr Corporation). Resin composites were light cured using a multipeak light-emitting diode light-curing unit (VALO, Ultradent Products Inc, South Jordan, UT, USA) in its regular mode. Samples were evaluated by µCT, and data were imported into software (Amira, version 5.5.2, VSG, Burlington, MA, USA) for 3D reconstruction, from which the percentage of void volume was calculated. Data were analyzed using two-way analysis of variance and Tukey post hoc test at a preset alpha of 0.05. RESULTS: The conventional insertion method resulted in reduced porosity, compared with sonic insertion, for SureFil SDR Flow and Tetric EvoCeram bulk fill. The sonic insertion method did not demonstrate any influence on void formation for Herculite Ultra or SonicFill. CONCLUSION: Results suggest that the sonic insertion method might increase void formation during resin composite delivery, depending on restorative material brand.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Restauración Dental Permanente , Ultrasonido , Microtomografía por Rayos X , Imagenología Tridimensional , Ensayo de Materiales
20.
Oper Dent ; 42(4): 445-455, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28402731

RESUMEN

OBJECTIVES: The aims of this study were to characterize inorganic content (IC), light transmission (LT), biaxial flexural strength (BFS), and flexural modulus (FM) of one conventional (layered) and four bulk-fill composites at different depths. METHODS: Bulk-fill composites tested were Surefil SDR flow (SDR), Filtek Bulk Fill (FBF), Tetric EvoCeram Bulk Fill (TEC), and EverX Posterior (EXP). Herculite Classic (HER) was used as a control. Energy dispersive x-ray analysis and scanning electron microscopy were used to characterize filler particle composition and morphology. The LT through different composite thicknesses (1, 2, 3, and 4 mm) was measured using a laboratory-grade spectral radiometer system (n=5). For the BFS and FM tests, sets of eight stacked composite discs (0.5-mm thick) were prepared simulating bulk filling of a 4-mm-thick increment (n=8). RESULTS: SDR demonstrated larger, irregular particles than those observed in TEC or HER. Filler particles in FBF were spherical, while those in EXP were composed of fiberglass strands. The LT decreased with increased composite thickness for all materials. Bulk-fill composites allowed higher LT than the HER. Furthermore, HER proved to be the unique material, having lower BFS values at deeper regions. SDR, FBF, and TEC bulk-fill composites presented reduced FM with increasing composite depth. CONCLUSIONS: The bulk-fill composites investigated exhibited higher LT, independent of different filler content and characteristics. Although an increase in composite thickness reduced LT, the BFS of bulk-fill composites at deeper layers was not compromised.


Asunto(s)
Resinas Compuestas/química , Materiales Dentales/química , Dureza , Luz , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Espectrometría por Rayos X , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...