Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Materials (Basel) ; 16(5)2023 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-36903245

RESUMEN

This study evaluates the effect of aging in artificial saliva and thermal shocks on the microhardness of the bulk-fill composite compared to the nanohybrid composite. Two commercial composites, Filtek Z550 (3M ESPE) (Z550) and Filtek Bulk-Fill (3M ESPE) (B-F), were tested. The samples were exposed to artificial saliva (AS) for one month (control group). Then, 50% of the samples from each composite were subjected to thermal cycling (temperature range: 5-55 °C, cycle time: 30 s, number of cycles: 10,000) and another 50% were put back into the laboratory incubator for another 25 months of aging in artificial saliva. The samples' microhardness was measured using the Knoop method after each stage of conditioning (after 1 month, after 10,000 thermocycles, after another 25 months of aging). The two composites in the control group differed considerably in hardness (HK = 89 for Z550, HK = 61 for B-F). After thermocycling, the microhardness decrease was for Z550 approximately 22-24% and for B-F approximately 12-15%. Hardness after 26 months of aging decreased for Z550 (approximately 3-5%) and B-F (15-17%). B-F had a significantly lower initial hardness than Z550, but it showed an approximately 10% lower relative reduction in hardness.

2.
Materials (Basel) ; 16(2)2023 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-36676309

RESUMEN

This article presents comparative tests of contact strength and tribological wear resistance of polymer sliding materials of the polyamide group. The aim of this work was to study Shore hardness, indentation hardness, modulus, creep, relaxation, Martens hardness and sliding wear resistance of two commercial materials. One of these materials was produced with the recycling process in mind. Abrasion tests were performed against a stainless-steel ball (100CRr6) on a normal load of 5 N for 23,830 friction cycles. The samples were tested under dry friction conditions and taking into account the hydrothermal factor, the presence of which was assumed in the anticipated operating conditions. It was distilled water at a temperature of 50 °C. The volumetric wear of the samples under various environmental conditions was assessed and related to the mechanical properties, in particular, Shore hardness. This mechanical size, which characterizes the surface, was considered the most frequently used by engineers selecting polymeric materials for tribological applications in industry. The Shore hardness of both materials was similar, which may indicate similar tribological performance properties. However, research and analysis indicate the need to use measures that directly correspond to tribological wear. The friction and wear of both materials varied. The coefficient of friction in hydrothermal conditions was lower and the wear was higher than in the dry friction test. It seems that it was not hardness that determined the suitability in the anticipated operating conditions, but the ability to form a sliding layer on the friction surface. The properties of the material that has been envisaged as a replacement may be appropriate for the intended uses.

3.
Materials (Basel) ; 14(11)2021 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-34071606

RESUMEN

BACKGROUND: Clinical success depends on the contact strength and wear resistance of medical devices made of polymer materials. The scientific goal resulted from the problem of using different methods of surface evaluation of materials used in the production of orthodontic appliances. The purpose of the work was an experimental comparative assessment of indentation hardness and scratch hardness and the sliding wear of four selected polymeric materials used in the manufacture of orthodontic appliances. METHODS: Four commercial materials were compared. Shore hardness tests and a scratch test with a Rockwell indenter were performed. A sliding wear test was performed using the ball-on-disc method. Statistical PCA and correlation analyses were performed. RESULTS: The results of scratch hardness measurements using a contact profilometer correlated with the Shore hardness to a greater extent than measurements made using an optical microscope. PCA showed that Shore hardness explains 45% of the total variance in all the results across the materials. CONCLUSIONS: The scratch hardness method allows for a more explicit ranking of orthodontic polymeric materials when measurements are made with a profilometer. The ranking of sliding wear resistance should be made separately.

4.
Materials (Basel) ; 12(22)2019 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-31698746

RESUMEN

This study discusses a quantitative fatigue evaluation of polymer-ceramic composites for dental restorations, i.e., commercial (Filtek Z550) and experimental Ex-nano (G), Ex-flow (G). Their evaluation is based on the following descriptors: mechanical strength, elastic modulus and strain work to fracture. Supposed to reflect factors of environmental degradation conditions, thermal fatigue was simulated with a special computer-controlled device performing algorithms of thermocycling. The specimens intended for the strength test underwent 104 hydro-thermal fatigue cycles. This procedure of thermocycling was preceded by aging, which meant immersing the specimens in artificial saliva at 37 °C for 30 days. The strength tests after aging only and after aging and thermocycles were performed in line with the three-point flexural strength (TFS) test, specified in ISO 4049, and the biaxial flexural strength (BFS) test, specifically piston-on-three-ball in accordance with ISO 6872. Based on the results, it can be stated that composites with higher volume content of inorganic particles after aging only show higher strength than materials with lower filler particle content. For example, the average flexural bending strength of the Ex-flow (G) composite was about 45% lower than the value obtained for the Ex-nano (G) material. The residual strength after thermocycles is significantly lower for the experimental composites, whereas a smaller decrease in strength is recorded for the commercial composites. Decreases in strength were about 4% (Filtek Z550), 43% (Ex-nano (G)), and 29% (Ex-flow (G)) for the BFS test; and about 17% (Filtek Z550), 55% (Ex-nano (G)), 60% (Ex-flow (G)) for the TFS test. The elastic modulus of the experimental composites after only aging is higher (about 42%) than that of the commercial composite, but the elastic modulus of the commercial composite increases significantly after thermocycling. A descriptor known as strain work to fracture turns out to be a good descriptor for evaluating the hydro-thermal fatigue of the tested polymer-ceramic composites.

5.
Eur J Orthop Surg Traumatol ; 22(5): 403-406, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22754429

RESUMEN

The purpose of this study was to evaluate the early results of the Ponseti method in reducing extensive corrective surgery rates for congenital idiopathic clubfoot in patients treated in Children's Orthopaedic Clinic and Rehabilitation Department Medical University of Lublin between the years 2007-2011. Thirty-five patients with 47 idiopathic clubfeet were followed prospectively while being managed with the Ponseti method. Clubfoot severity was graded with use of the Dimeglio system. The initial correction was achieved, and early results were measured by using Pirani scoring method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA