Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
2.
Int J Cardiol ; 407: 132061, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38641263

RESUMEN

BACKGROUND AND AIMS: Intracoronary pressure gradients and translesional flow patterns have been correlated with coronary plaque progression and lesion destabilization. In this study, we aimed to determine the relationship between endothelial shear stress and plaque progression and to evaluate the effect of shear forces on coronary plaque features. METHODS: A systematic review was conducted in medical on-line databases. Selected were studies including human participants who underwent coronary anatomy assessment with computational fluid dynamics (CFD)-based wall shear stress (WSS) calculation at baseline with anatomical evaluation at follow-up. A total of six studies were included for data extraction and analysis. RESULTS: The meta-analysis encompassed 31'385 arterial segments from 136 patients. Lower translesional WSS values were significantly associated with a reduction in lumen area (mean difference -0.88, 95% CI -1.13 to -0.62), an increase in plaque burden (mean difference 4.32, 95% CI 1.65 to 6.99), and an increase in necrotic core area (mean difference 0.02, 95% CI 0.02 to 0.03) at follow-up imaging. Elevated WSS values were associated with an increase in lumen area (mean difference 0.78, 95% CI 0.34 to 1.21) and a reduction in both fibrofatty (mean difference -0.02, 95% CI -0.03 to -0.01) and fibrous plaque areas (mean difference -0.03, 95% CI -0.03 to -0.03). CONCLUSION: This meta-analysis shows that WSS parameters were related to vulnerable plaque features at follow-up. These results emphasize the impact of endothelial shear forces on coronary plaque growth and composition. Future studies are warranted to evaluate the role of WSS in guiding clinical decision-making.


Asunto(s)
Enfermedad de la Arteria Coronaria , Progresión de la Enfermedad , Endotelio Vascular , Placa Aterosclerótica , Estrés Mecánico , Humanos , Placa Aterosclerótica/fisiopatología , Placa Aterosclerótica/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Endotelio Vascular/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología
3.
Clin Res Cardiol ; 113(4): 591-601, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38329513

RESUMEN

INTRODUCTION: Acute coronary syndromes (ACS) represent a substantial global healthcare challenge. In its most severe form, it can lead to out-of-hospital cardiac arrest (OHCA). Despite medical advancements, survival rates in OHCA patients remain low. Further, the prediction of outcomes in these patients poses a challenge to all health care providers involved. This study aims at developing a score with variables available on admission to assess in-hospital mortality of patients with OHCA undergoing coronary angiography. METHOD: All patients with OHCA due to ACS admitted to a tertiary care center were included. A multivariate logistic regression analysis was conducted to explore the association between clinical variables and in-hospital all-cause mortality. A scoring system incorporating variables available upon admission to assess individual patients' risk of in-hospital mortality was developed (FACTOR score). The score was then validated. RESULTS: A total of 291 patients were included in the study, with a median age of 65 [56-73] years, including 47 women (16.2%). The in-hospital mortality rate was 41.2%. A prognostic model was developed in the derivation cohort (n = 138) and included the following variables: age, downtime, first detected rhythm, and administration of epinephrine. The area under the curve for the FACTOR score was 0.823 (95% CI 0.737-0.894) in the derivation cohort and 0.828 (0.760-0.891) in the validation cohort (n = 153). CONCLUSION: The FACTOR score demonstrated a reliable prognostic tool for health care providers in assessing in-hospital mortality of OHCA patients. Early acknowledgement of a poor prognosis may help in patient management and allocation of resources.


Asunto(s)
Síndrome Coronario Agudo , Reanimación Cardiopulmonar , Paro Cardíaco Extrahospitalario , Humanos , Femenino , Persona de Mediana Edad , Anciano , Paro Cardíaco Extrahospitalario/diagnóstico , Paro Cardíaco Extrahospitalario/terapia , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/terapia , Mortalidad Hospitalaria , Pronóstico , Hospitalización
4.
Int J Cardiol ; 395: 131429, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-37827283

RESUMEN

BACKGROUND: Spontaneous coronary artery dissection (SCAD) has been described as an infrequent cause of acute coronary syndrome (ACS). Knowledge about the disease is still limited and SCAD might still be underdiagnosed. OBJECTIVES: Trends in incidence, presentation, angiographic appearance, management, and outcomes of SCAD over 25 years were analyzed. METHODS: Patients with SCAD between 1997 and 2021 at the University Hospital Zurich, Switzerland, were included. Incidences were assessed as total numbers and proportions of ACS cases. Clinical data were collected from medical records and angiographic findings were reviewed. Major adverse cardiac events (MACE) were defined as the composite of all-cause death, cardiac arrest, SCAD recurrence or progression, other myocardial infarction, and stroke. RESULTS: One hundred fifty-six SCAD cases were included in this study. The incidence increased significantly in total (p < 0.001) and relative to ACS cases (p < 0.001). This was based on an increase of shorter lesions (p = 0.004), SCAD type 2 (p < 0.001), and lesions in side branches (p = 0.014), whereas lesions in the left main coronary artery and proximal segments were decreasing (p-values 0.029 and < 0.001, respectively). There was an increase in conservative therapy (p < 0.001). The rate of MACE (24%) was stable, however, there was a reduced proportion of patients with a need for intensive care treatment (p = 0.017). CONCLUSIONS: SCAD represents an important entity of ACS that still might be underappreciated. The increasing incidence of SCAD is likely based on better awareness and familiarity with the disease. A lower need for intensive care treatment suggests positive effects of the increasing implementation of conservative management.


Asunto(s)
Síndrome Coronario Agudo , Anomalías de los Vasos Coronarios , Enfermedades Vasculares , Humanos , Incidencia , Factores de Riesgo , Vasos Coronarios , Angiografía Coronaria/efectos adversos , Enfermedades Vasculares/diagnóstico por imagen , Enfermedades Vasculares/epidemiología , Enfermedades Vasculares/terapia , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/epidemiología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/epidemiología , Anomalías de los Vasos Coronarios/terapia
5.
Clin Res Cardiol ; 2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-37985475

RESUMEN

BACKGROUND: Coronary microvascular dysfunction (CMD) has been proposed as a crucial factor in the pathophysiology of Takotsubo syndrome (TTS). The angiography-derived index of microcirculatory resistance (caIMR) offers an alternative to conventional hyperemic wire-based IMR to assess CMD. We aimed to evaluate CMD's prevalence, transience, and impact on in-hospital outcomes in TTS. METHODS: All three coronary arteries of 96 patients with TTS were assessed for their coronary angiography derived Index of microcirculatory Resistance (caIMR) and compared to non-obstructed vessels of matched patients with ST-elevation myocardial infarction. Further, the association between caIMR and the TTS-specific combined in-hospital endpoint of death, cardiac arrest, ventricular arrhythmogenic events and cardiogenic shock was investigated. RESULTS: Elevated IMR was present in all TTS patients, with significantly elevated caIMR values in all coronary arteries compared to controls. CaIMR did not differ between apical and midventricular TTS types. CaIMR normalized in TTS patients with follow-up angiographies performed at a median of 28 months (median caIMR at event vs follow-up: LAD 34.8 [29.9-41.1] vs 20.3 [16.0-25.3], p < 0.001; LCX: 38.7 [32.9-50.1] vs 23.7 [19.4-30.5], p < 0.001; RCA: 31.7 [25.0-39.1] vs 19.6 [17.1-24.0], p < 0.001). The extent of caIMR elevation significantly correlated with the combined in-hospital endpoint (p = 0.036). CONCLUSION: TTS patients had evidence of elevated caIMR in at least one coronary artery with a trend towards higher LAD caIMR in apical type TTS and normalization after recovery. Furthermore, extent of caIMR elevation was associated with increased risk of in-hospital MACE of TTS patients.

6.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37889200

RESUMEN

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Insuficiencia Renal Crónica , Accidente Cerebrovascular , Humanos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Pronóstico , Resultado del Tratamiento , Estudios Retrospectivos , Hemorragia/inducido químicamente , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Insuficiencia Renal Crónica/epidemiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Anticoagulantes/efectos adversos
7.
CJC Open ; 5(6): 404-411, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37397616

RESUMEN

Background: Oral anticoagulation (OAC) is deemed a relative contraindication after intracranial hemorrhage (ICH) if the cause cannot be eliminated and the risk of recurrence is high. That leaves atrial fibrillation (AF) patients at high risk of thromboembolic events. Endovascular left atrial appendage closure (LAAC) can be an alternative to OAC for patients requiring stroke prevention. Methods: We performed a retrospective single-centre analysis of 138 consecutive ICH patients with nonvalvular AF and high stroke risk who underwent LAAC between 2010 and 2022 at Vancouver General Hospital. We report the baseline characteristics, procedural results, and follow-up data, comparing the observed stroke/transient ischemic attack (TIA) rate with the predicted event rate based on their CHA2DS2-VASc scores. Results: The average age was 76.1 ± 8.5 years; the mean CHA2DS2-VASc score was 4.4 ± 1.5; and the mean HAS-BLED score was 3.7 ± 0.9. The procedural success rate was 98.6%, and the complication rate was 3.6% with no periprocedural death, stroke, or TIA. The antithrombotic regimen post-LAAC consisted of short-term dual antiplatelet therapy (1-6 months) followed by aspirin alone for a minimum of 6 months in 86.2%. At mean follow-up of 14.7 ± 13.7 months, 9 deaths (6.5%, 7 cardiovascular, 2 noncardiovascular), 2 strokes (1.4%), and 1 TIA (0.7%) had occurred. The annualized observed stroke/TIA rate was 1.8%, which was lower than the adjusted predicted stroke rate of 7.0% (95% confidence interval: 4.8%-9.2%). Two patients (1.5%) suffered another ICH (both on aspirin monotherapy). One device-related thrombus (0.7%) was confirmed and treated with OAC without sequelae. Conclusion: Endovascular LAAC is a feasible alternative to OAC for stroke prevention in patients with nonvalvular AF and prior ICH.


Contexte: L'anticoagulation par voie orale (ACO) est considérée comme une contre-indication relative après une hémorragie intracrânienne (HIC) si la cause ne peut être éliminée et si le risque de récidive est élevé. Les patients souffrant de fibrillation auriculaire (FA) sont donc exposés à un risque élevé d'événements thromboemboliques. La technique de fermeture percutanée de l'appendice auriculaire gauche (AAG) peut être une solution de rechange aux anticoagulants oraux en prévention des accidents vasculaires cérébraux (AVC). Méthodologie: Nous avons réalisé une analyse rétrospective unicentrique auprès de 138 patients consécutifs qui étaient atteints d'une HIC accompagnée d'une FA non valvulaire ainsi que d'un risque élevé d'AVC et qui ont subi une fermeture de l'AAG entre 2010 et 2022 à l'hôpital général de Vancouver. Nous présentons ici les caractéristiques initiales, les résultats de l'intervention et les données de suivi, en comparant le taux d'AVC/AIT (accident ischémique transitoire) observé avec le taux prédit d'événements sur la base de leurs scores CHA2DS2-VASc. Résultats: L'âge moyen était de 76,1 ± 8,5 ans. Le score CHA2DS2-VASc moyen était de 4,4 ± 1,5, et le score HAS-BLED moyen de 3,7 ± 0,9. Le taux de réussite de l'intervention a été de 98,6 % et le taux de complications de 3,6 %, sans décès périopératoires, ni AVC ou AIT. Le traitement antithrombotique après la fermeture de l'AAG consistait en une bithérapie antiplaquettaire de courte durée (de 1 à 6 mois), suivie de la prise d'aspirine seule pendant au moins 6 mois dans 86,2 % des cas. Après un suivi moyen de 14,7 ± 13,7 mois, 9 décès (6,5 %, 7 d'origine cardiovasculaire et 2 d'origine non cardiovasculaire), 2 AVC (1,4 %) et 1 AIT (0,7 %) sont survenus. Le taux annualisé d'AVC/AIT observé était de 1,8 %, ce qui est inférieur au taux prédit d'AVC après ajustement, soit 7,0 % (intervalle de confiance à 95 % : 4,8 % à 9,2 %). Deux patients (1,5 %) ont souffert d'une autre HIC (tous deux sous aspirine en monothérapie). Un thrombus lié au dispositif (0,7 %) a été confirmé et traité par anticoagulathérapie orale sans séquelles. Conclusion: La technique de fermeture de l'AAG représente une solution de rechange à l'anticoagulation par voie orale dans la prévention des AVC chez les patients souffrant de FA non valvulaire et ayant déjà subi une HIC.

8.
JACC Case Rep ; 17: 101900, 2023 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-37496718

RESUMEN

A 62-year-old man experienced embolization of a patent foramen ovale (PFO) occlusion device in the pulmonary artery. The device was successfully retrieved using "puncture to loop" technique, without the need of specific materials. This is a challenging retrieval situation, confirming the feasibility and flexibility of the technique. (Level of Difficulty: Advanced.).

9.
CJC Open ; 5(7): 522-529, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37496779

RESUMEN

Background: Access to left atrial appendage closure (LAAC) in Canada is limited, due to funding restrictions. This work aimed to assess Canadian clinical practice on patient selection, postprocedural antithrombotic therapy, and safety and/or efficacy with WATCHMAN device implantation. Methods: Seven Canadian centres implanting the WATCHMAN device participated in this prospective multicentre, observational registry. All procedures were done under general anesthesia with transesophageal echocardiography guidance. Patients were prospectively followed for 2years. The long-term stroke rate was compared with the expected rate based on the CHA2DS2-VASc score. Results: A total of 272 patients who underwent LAAC with the WATCHMAN device between December 2013 and August 2019 (mean age: 75.4 years [standard deviation {SD}: 8.75]; male, 63.2%; CHA2DS2-VASc score: 4.35 [SD: 1.64]; HAS-BLED score: 3.55 [SD: 0.94]) were included. Most patients (90.4%) had prior history of bleeding (major, 80.5%; minor, 21.7%). The WATCHMAN device was successfully implanted in 269 patients (98.9%), with a few procedure-related complications, including 5 pericardial effusions requiring drainage (1.8%), and 1 death (0.4%; 22 days post-LAAC from respiratory failure). Post-LAAC antithrombotic therapy included dual antiplatelet therapy in 70.6%, single antiplatelet therapy in 18.4%, and oral anticoagulation in 13.6%. During the follow-up period (mean: 709.7 days [SD: 467.2]), an 81.4% reduction of the ischemic stroke rate occurred, based on the expected rate from the CHA2DS2-VASc score (6.0% expected vs 1.1% observed). Device-related thrombus was detected in 1.8%. Conclusions: The majority of Canadian patients who underwent LAAC had oral anticoagulation contraindication due to prior bleeding, and most were safely treated with antiplatelet therapy post-LAAC, with a low device-related thrombus incidence. Long-term follow-up demonstrated that LAAC achieved a significant reduction in ischemic stroke rate.


Contexte: Au Canada, l'accès à la fermeture de l'appendice auriculaire gauche (FAAG) est limité en raison de restrictions quant au financement de cette intervention. Le présent rapport visait à évaluer les pratiques cliniques canadiennes sur la sélection des patients, le traitement antithrombotique après l'intervention et l'innocuité ou l'efficacité par l'implantation d'un dispositif WATCHMAN. Méthodologie: Sept centres canadiens procédant à l'implantation du dispositif WATCHMAN ont participé à ce registre observationnel, prospectif et multicentrique. Toutes les interventions ont été réalisées sous anesthésie générale avec guidage par échocardiographie transœsophagienne. Les patients ont par la suite été suivis de manière prospective pendant deux ans. Le taux d'AVC à long terme a été comparé au taux attendu, selon le score CHA2DS2-VASc. Résultats: Ont été inclus à l'étude 272 patients ayant subi une FAAG avec implantation d'un dispositif WATCHMAN entre décembre 2013 et août 2019 (âge moyen : 75,4 ans [écart-type {É.-T.} : 8,75]; hommes : 63,2 %; score CHA2DS2-VASc : 4,35 [É.-T. : 1,64]; score HAS-BLED : 3,55 [É.-T. : 0,94]). La plupart des patients (90,4 %) avaient des antécédents de saignements (majeurs : 80,5 %; mineurs : 21,7 %). Le dispositif WATCHMAN a bien été implanté chez 269 patients (98,9 %), avec quelques complications associées à l'intervention, dont cinq effusions péricardiques nécessitant un drainage (1,8 %) et un décès (0,4 %; 22 jours après la FAAG, en raison d'une insuffisance respiratoire). Le traitement antithrombotique après la FAAG comprenait une bithérapie antiplaquettaire dans 70,6 % des cas, une monothérapie antiplaquettaire dans 18,4 % des cas et une anticoagulothérapie orale dans 13,6 % des cas. Pendant la période de suivi (durée moyenne : 709,7 jours [É.-T. : 467,2]), on a noté une réduction de 81,4 % du taux d'AVC ischémique observé par rapport au taux attendu selon le score CHA2DS2-VASc (taux attendu : 6,0 %; taux observé : 1,1 %). Un thrombus associé au dispositif a été détecté dans 1,8 % des cas. Conclusions: La majorité des patients canadiens qui ont subi une FAAG présentaient des contre-indications à l'anticoagulothérapie orale en raison de leurs antécédents de saignements, et la plupart ont été traités de manière sécuritaire par des thérapies antiplaquettaires après la chirurgie, avec un faible taux d'incidence de thrombus associé au dispositif. Le suivi à long terme a montré que la FAAG permet d'obtenir une réduction importante du taux d'AVC ischémique.

10.
Clin Res Cardiol ; 112(12): 1790-1799, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37294311

RESUMEN

BACKGROUND: Device-related thrombus (DRT) after left atrial appendage closure (LAAC) is associated with adverse outcomes, i.e. ischemic stroke or systemic embolism (SE). Data on predictors of stroke/SE in the context of DRT are limited. AIMS: This study aimed to identify predisposing factors for stroke/SE in DRT patients. In addition, the temporal connection of stroke/SE to DRT diagnosis was analyzed. METHODS: The EUROC-DRT registry included 176 patients, in whom DRT after LAAC were diagnosed. Patients with symptomatic DRT, defined as stroke/SE in the context of DRT diagnosis, were compared against patients with non-symptomatic DRT. Baseline characteristics, anti-thrombotic regimens, device position, and timing of stroke/SE were compared. RESULTS: Stroke/SE occurred in 25/176 (14.2%) patients diagnosed with DRT (symptomatic DRT). Stroke/SE occurred after a median of 198 days (IQR 37-558) after LAAC. In 45.8% stroke/SE occurred within one month before/after DRT diagnosis (DRT-related stroke). Patients with symptomatic DRT had lower left ventricular ejection fractions (50.0 ± 9.1% vs. 54.2 ± 11.0%, p = 0.03) and higher rates of non-paroxysmal atrial fibrillation (84.0% vs. 64.9%, p = 0.06). Other baseline parameters and device positions were not different. Most ischemic events occurred among patients with single antiplatelet therapy (50%), however, stroke/SE was also observed under dual antiplatelet therapy (25%) or oral anticoagulation (20%). CONCLUSION: Stroke/SE are documented in 14.2% and occur both in close temporal relation to the DRT finding and chronologically independently therefrom. Identification of risk factors remains cumbersome, putting all DRT patients at substantial risk for stroke/SE. Further studies are necessary to minimize the risk of DRT and ischemic events.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Humanos , Resultado del Tratamiento , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Sistema de Registros , Apéndice Atrial/diagnóstico por imagen
11.
Int J Cardiol ; 386: 1-7, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37201616

RESUMEN

AIMS: Spontaneous coronary artery dissection (SCAD) is an increasingly diagnosed cause of myocardial infarction with unclear pathophysiology. The aim of the study was to test if vascular segments site of SCAD present distinctive local anatomy and hemodynamic profiles. METHODS: Coronary arteries with spontaneously healed SCAD (confirmed by follow-up angiography) underwent three-dimensional reconstruction, morphometric analysis with definition of vessel local curvature and torsion, and computational fluid dynamics (CFD) simulations with derivation of time-averaged wall shear stress (TAWSS) and topological shear variation index (TSVI). The (reconstructed) healed proximal SCAD segment was visually inspected for co-localization with curvature, torsion, and CFD-derived quantities hot spots. RESULTS: Thirteen vessels with healed SCAD underwent the morpho-functional analysis. Median time between baseline and follow-up coronary angiograms was 57 (interquartile range [IQR] 45-95) days. In seven cases (53.8%), SCAD was classified as type 2b and occurred in the left anterior descending artery or near a bifurcation. In all cases (100%), at least one hot spot co-localized within the healed proximal SCAD segment, in 9 cases (69.2%) ≥ 3 hot spots were identified. Healed SCAD in proximity of a coronary bifurcation presented lower TAWSS peak values (6.65 [IQR 6.20-13.20] vs. 3.81 [2.53-5.17] Pa, p = 0.008) and hosted less frequently TSVI hot spots (100% vs. 57.1%, p = 0.034). CONCLUSION: Vascular segments of healed SCAD were characterized by high curvature/torsion and WSS profiles reflecting increased local flow disturbances. Hence, a pathophysiological role of the interaction between vessel anatomy and shear forces in SCAD is hypothesized.


Asunto(s)
Anomalías de los Vasos Coronarios , Infarto del Miocardio , Enfermedades Vasculares , Humanos , Vasos Coronarios/diagnóstico por imagen , Enfermedades Vasculares/diagnóstico por imagen , Infarto del Miocardio/etiología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria/efectos adversos , Hemodinámica
12.
Eur J Public Health ; 33(3): 424-429, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36940682

RESUMEN

BACKGROUND: Major sporting events are postulated to reduce suicide rates by increased social connectedness, by identifying with winning teams, or, conversely, to increase suicide rates by the 'broken promise effect'. METHODS: In our observational epidemiological study, we investigated changes in suicide rates between 1970 and 2017 in Austria, Germany and Switzerland during the European and World Soccer Championships in general, and on days that the home team played, won or lost. RESULTS: Combining all three studied nations no statistically significant change in the incidence of daily suicides during soccer championships compared to a control period was noted (38.29 ± 9.02 vs. 37.33 ± 10.58; incidence risk ratio = 1.03; 95% confidence interval: 1.01-1.05, P = 0.05). Essentially, no differences in the expected directions were found, and none remained statistically significant after correcting for multiple comparisons in subgroups for country, age and gender in all three studied countries. Compared to a control period, neither a significant difference in the respective national suicide rate was found after Germany's four championship victories nor after Austria's emotional only win over Germany. CONCLUSION: Our results do not support the assumption of increased social connectedness and, thus, lowered suicide risk during major sporting events or changes in suicide risk depending on the outcome of important games as predicted by the broken promise effect or changes in self-efficacy by identification with winning teams.


Asunto(s)
Fútbol , Suicidio , Humanos , Suicidio/psicología , Austria/epidemiología , Suiza/epidemiología , Alemania/epidemiología
13.
Clin Res Cardiol ; 112(5): 605-613, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36646858

RESUMEN

BACKGROUND: As numbers and complexity of percutaneous coronary interventions are constantly increasing, optimal radiation protection is required to ensure operator safety. Suspended radiation protection systems (SRPS) and protective scatter-radiation absorbing drapes (PAD) are novel methods to mitigate fluoroscopic scattered radiation exposure. The aim of the study was to investigate the effectiveness regarding radiation protection of a SRPS and a PAD in comparison with conventional protection. METHODS: A total of 229 cardiac catheterization procedures with SRPS (N = 73), PAD (N = 82) and standard radiation protection (N = 74) were prospectively included. Real-time dosimeter data were collected from the first operator and the assistant. Endpoints were the cumulative operator exposure relative to the dose area product [standardized operator exposure (SOE)] for the first operator and the assistant. RESULTS: For the first operator, the SRPS and the PAD significantly decreased the overall SOE compared to conventional shielding by 93.9% and 66.4%, respectively (P < 0.001). The protective effect of the SRPS was significantly higher compared to the PAD (P < 0.001). For the assistant, the SRPS and the PAD provided a not statistically significant reduction compared to conventional shielding in the overall SOE by 38.0% and 30.6%, respectively. CONCLUSIONS: The SRPS and the PAD enhance radiation protection significantly compared to conventional protection. In most clinical scenarios, the protective effect of SRPS is significantly higher than the additional protection provided by the PAD. Comparison of the additional radiation protection provided by protective scatter-radiation absorbing drapes (PAD) and the suspended radiation protection system (SRPS) system over standard protection with lead aprons.


Asunto(s)
Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Humanos , Exposición Profesional/efectos adversos , Exposición Profesional/prevención & control , Exposición a la Radiación/efectos adversos , Exposición a la Radiación/prevención & control , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Dosis de Radiación , Radiografía Intervencional/efectos adversos
15.
Clin Res Cardiol ; 111(11): 1276-1285, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35849156

RESUMEN

BACKGROUND: Data on Device-related Thrombus (DRT) after left atrial appendage closure (LAAC) remain scarce. This study aimed to investigate risk factors for DRT from centers reporting to the EUROC-DRT registry. METHODS: We included 537 patients (112 with DRT and 425 without DRT) who had undergone LAAC between 12/2008 and 04/2019. Baseline and implantation characteristics, anti-thrombotic treatment and clinical outcomes were compared between both groups in uni- and multivariate analyses. Additional propensity-score matching (PSM) was conducted to focus on the role of implantation characteristics. RESULTS: Patients with DRT showed higher rates of previous stroke/transient ischemic attack (TIA) (49.1% vs. 34.7%, p < 0.01), spontaneous echocardiographic contrast (SEC) (44.9% vs. 27.7%, p < 0.01) and lower left atrial appendage (LAA) peak emptying velocity (35.4 ± 18.5 vs. 42.4 ± 18.0 cm/s, p = 0.02). Occluders implanted in DRT patients were larger (25.5 ± 3.8 vs. 24.6 ± 3.5 mm, p = 0.03) and implanted deeper in the LAA (mean depth: 7.6 ± 4.7 vs. 5.7 ± 4.7 mm, p < 0.01). Coverage of the appendage ostium was achieved less often in DRT patients (69.5% vs. 81.5%, p < 0.01), while DRT patients were less frequently on oral anticoagulation (7.1% vs. 16.7%, p < 0.01). Multivariate analysis identified age, prior stroke/TIA and SEC as independent risk factors for DRT. After PSM, implantation depth was found to be predictive. Rates of stroke/TIA were higher in DRT patients (13.5% vs. 3.8%, Hazard Ratio: 4.21 [95%-confidence interval: 1.88-9.49], p < 0.01). CONCLUSIONS: DRT after LAAC is associated with adverse outcome and appears to be of multifactorial origin, depending on patient characteristics, anticoagulation regimen and device position.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Trombosis/diagnóstico , Trombosis/epidemiología , Trombosis/etiología , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Factores de Riesgo , Ecocardiografía , Sistema de Registros , Anticoagulantes/uso terapéutico
16.
J Interv Card Electrophysiol ; 63(1): 9-12, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33479854

RESUMEN

BACKGROUND: Despite maturing experience, transseptal puncture (TSP) remains a challenging part of percutaneous left atrial appendage closure (LAAC) and has inherent risks and safety concerns in accessing the left atrium (LA). The VersaCross radiofrequency (RF) system (Baylis Medical), a new RF-tipped pigtail wire-based TSP system, may facilitate LA access by serving as an exchange support wire once access is achieved. METHODS: We retrospectively compared TSP safety and procedural efficiency in 10 consecutive LAAC cases using the VersaCross RF system to 10 cases using the conventional BRK1-XS mechanical needle (Abbott Vascular). The safety and time from femoral access to delivery of the device sheath were compared to the conventional workflow using BRK1-XS/SL1. RESULTS: We included consecutive 20 cases between July 2019 and November 2019 (12 with WATCHMAN (Boston Scientific, Natick, MA) and 8 with Amulet (St. Jude Medical, St Paul, MN)). Baseline patient characteristics and procedural details were similar in both groups (VersaCross RF system vs. conventional BRK1-XS mechanical needle). All cases were completed successfully with no procedural or in-hospital complications. VersaCross reduced time from femoral access to TSP [4.1 ± 2.5 min vs. 8.4 ± 4.0 min (p = 0.009)] and time from femoral access to delivery sheath access into LA [6.7 ± 2.4 min vs. 13.4 ± 5.4 min (p = 0.002)] compared to BRK1-XS. CONCLUSIONS: Combining a starter wire, transseptal needle and exchange guidewire in the VersaCross RF system enabled faster LA access, which potentially leads to efficient workflow. Further investigation with larger sample size is warranted to corroborate our findings.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
17.
Diagn Interv Radiol ; 27(6): 703-709, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34792023

RESUMEN

PURPOSE: Cardiac computed tomography angiography (CCTA) is increasingly used for device surveillance after left atrial appendage closure (LAAC). While CT protocols with delayed scans are useful to diagnose thrombus in the LAA, an optimal protocol for post-procedural CCTA has not been established. Therefore, we assessed the role of delayed versus early scans for device surveillance. METHODS: We retrospectively reviewed patients who underwent LAAC at Vancouver General Hospital who had follow-up CCTAs using standard (early) and delayed scans. Scans were performed on Toshiba 320-detector (Aquilion ONE). Image quality was interpreted by 2 independent observers for anatomy, LAA contrast patency, and device-related thrombus (DRT) using VitreaWorkstationTM. A Likert scale of 1-5 was used (1= poor quality, 5= excellent) for assessment. RESULTS: We included 27 consecutive LAAC patients (9 Amplatzer, 18 WATCHMAN) with mean age 76.0±7.7 years, mean CHADS2 score 2.8±1.3, CHA2DS2-VASc score 4.4±1.6 and HAS-BLED score 3.4±1.0. Subjective quality assessments by both reviewers favored early scans for assessment of anatomy (reviewer 1: 4.63±0.63 [early] vs. 1.74±0.71 [delayed]; reviewer 2: 4.63±0.63 [early] vs. 1.89±0.64 [delayed]) and DRT (reviewer 1: 4.78±0.42 [early] vs. 3.11±1.16 [delayed]; reviewer 2: 4.70±0.47 [early] vs. 3.04±1.29 [delayed]). Inter-rater variability showed good correlation between reviewers (intraclass correlation 0.61-0.95). Mean LAA/LA attenuation ratios were significantly different between scans, with larger mean percent reduction of contrast opacification from LA to LAA in the early scans (57.0±36.6% reduction for early vs. 29.1±30.8% for delayed; p < 0.001) CONCLUSION: For CT device surveillance post-LAAC early phase imaging provides superior image quality objectively and subjectively compared with delayed scanning.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Anciano , Anciano de 80 o más Años , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Angiografía por Tomografía Computarizada , Humanos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
18.
Circ Cardiovasc Interv ; 14(5): e010195, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-34003661

RESUMEN

BACKGROUND: Left atrial appendage closure is an established therapy in patients with atrial fibrillation. Although device-related thrombosis (DRT) is relatively rare, it is potentially linked to adverse events. As data on DRT characteristics, outcome, and treatment regimen are scarce, we aimed to assess these questions in a multicenter approach. METHODS: One hundred fifty-six patients with the diagnosis of DRT after left atrial appendage closure were included in the multinational EUROC-DRT registry. Baseline characteristics included clinical and echocardiographic data. After inclusion, all patients underwent further clinical and echocardiographic follow-up to assess DRT dynamics, treatment success, and outcome. RESULTS: DRT was detected after a median of 93 days (interquartile range, 54­161 days) with 17.9% being detected >6 months after left atrial appendage closure. Patients with DRT were at high ischemic and bleeding risk (CHA2DS2-VASc 4.5±1.7, HAS-BLED 3.3±1.2) and had nonparoxysmal atrial fibrillation (67.3%), previous stroke (53.8%), and spontaneous echo contrast (50.6%). The initial treatment regimens showed comparable resolution rates (antiplatelet monotherapy: 57.1%, dual antiplatelet therapy: 85.7%, vitamin K antagonists: 80.0%, novel oral anticoagulants: 75.0%, and heparin: 68.6%). After intensification or switch of treatment, complete DRT resolution was achieved in 79.5% of patients. Two-year follow-up revealed a high risk of mortality (20.0%) and ischemic stroke (13.8%) in patients with DRT. Patients with incomplete DRT resolution showed numerically higher stroke rates and increased mortality rates (stroke: 17.6% versus 12.3%, P=0.29; mortality: 31.3% versus 13.1%, P=0.05). CONCLUSIONS: A substantial proportion of DRT is detected >6 months after left atrial appendage closure, highlighting the need for imaging follow-up. Patients with DRT appear to be at a high risk for stroke and mortality. While DRT resolution was achieved in most patients, incomplete DRT resolution appeared to identify patients at even higher risk. Optimal DRT diagnostic criteria and treatment regimens are warranted.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Trombosis , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Humanos , Sistema de Registros , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/terapia , Resultado del Tratamiento
19.
Catheter Cardiovasc Interv ; 97(7): E1025-E1032, 2021 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-33580751

RESUMEN

OBJECTIVES: To describe imaging assessment, procedural and follow-up outcome of patients undergoing left atrial appendage (LAA) occlusion (LAAO) using a "sandwich" technique. BACKGROUND: The presence of a LAA with chicken wing morphology constitutes a challenge that sometimes requires specific occlusion strategies like the "sandwich" technique. However, procedural and follow-up data focusing on this implanting strategy is scarce. METHODS: This multicenter study collected individual data from eight centers between 2012 and 2019. Consecutive patients with chicken-wing LAAs defined as an early (<20 mm from the ostium) and severe bend (>90°) who underwent LAAO with Amplatzer devices and using the "sandwich" technique were included in the analysis. RESULTS: Overall, 190 subjects were enrolled in the study. Procedures were done with the Amulet device (85%) and the Amplatzer Cardiac Plug (15%). Successful implantation was achieved in 99.5% with ≤1 partial recapture in 80% of cases. Single (46.2%) and dual antiplatelet therapy (39.4%) were the most used antithrombotic therapies after LAAO. In-hospital major adverse events rate was 1.5% with no deaths. One patient (0.5%) had cardiac tamponade requiring percutaneous drainage. With a mean follow-up of 19.6 ± 14.8 months, the mortality and stroke rates were 7.7%/year and 2.5%/year, respectively. Follow-up transesophageal echocardiography (TEE) at 2-3 months showed device-related thrombosis in 2.8% and peri-device leak ≥3 mm in 1.2% of patients. CONCLUSIONS: In a large series of patients with chicken wing LAA anatomies undergoing LAAO, the use of the "sandwich" technique was feasible and safe. Preprocedural imaging was a key-factor to determine specific measurements.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Ecocardiografía Transesofágica , Humanos , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 32(3): 729-734, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33476450

RESUMEN

BACKGROUND: Transseptal access for large sheaths may be encumbered by tissue resistance against the sheath-dilator stepped interface. The ExpanSure Large Access Transseptal Dilator (Baylis Medical) is designed as a single introducer and dilation device with a smooth sheath-dilator transition to support transseptal puncture. It may facilitate ease and efficiency of interatrial crossing. METHODS: This study experimentally evaluated the crossing force of ExpanSure relative to a conventional 8.5 F Swartz SL1 transseptal sheath and dilator in a benchtop septum model. Its ability to reduce the subsequent crossing force of a 14 F WATCHMAN delivery sheath was also tested. The clinical use of ExpanSure, including procedure time, was then validated in a series of left atrial appendage closure (LAAC) procedures. RESULTS: In a benchtop septum model (N = 12), less peak force (1.90 ± 0.08 N vs. 2.36 ± 0.09 N; p < .001) and overall work (17.3 ± 1.2 mJ vs. 28.0 ± 1.9 mJ; p < .001) were required to advance ExpanSure relative to a conventional SL1 transseptal sheath and dilator system. Peak force (2.34 ± 0.24 N vs. 2.65 ± 0.21 N; p < .003) and overall work (28.5 ± 3.9 mJ vs. 35.4 ± 2.1 mJ; p < .001) to advance a WATCHMAN sheath were also significantly lower after using ExpanSure than after using a conventional transseptal system. In 19 LAAC procedures, ExpanSure crossed the septum smoothly and integrated readily, which enabled efficient procedure completion (mean total procedure time 37.6 ± 13.5 min), with 100% success and no procedure-related complications. CONCLUSION: Experimental force measurements, combined with early clinical experience using ExpanSure, suggest that the tapered design with smooth transition without dilator-sheath step-up and the larger diameter, both facilitated ease and efficiency of interatrial crossing.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Atrios Cardíacos/cirugía , Humanos , Punciones , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...