1.
Circ Cardiovasc Interv ; 17(1): e013204, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38152881

RESUMEN

BACKGROUND: Maldistribution of pulmonary blood flow in patients with congenital heart disease impacts exertional performance and pulmonary artery growth. Currently, measurement of relative pulmonary perfusion can only be performed outside the catheterization laboratory. We sought to develop a tool for measuring relative lung perfusion using readily available fluoroscopy sequences. METHODS: A retrospective cohort study was conducted on patients with conotruncal anomalies who underwent lung perfusion scans and subsequent cardiac catheterizations between 2011 and 2022. Inclusion criteria were nonselective angiogram of pulmonary vasculature, oblique angulation ≤20°, and an adequate view of both lung fields. A method was developed and implemented in 3D Slicer's SlicerHeart extension to calculate the amount of contrast that entered each lung field from the start of contrast injection and until the onset of levophase. The predicted perfusion distribution was compared with the measured distribution of pulmonary blood flow and evaluated for correlation, accuracy, and bias. RESULTS: In total, 32% (79/249) of screened studies met the inclusion criteria. A strong correlation between the predicted flow split and the measured flow split was found (R2=0.83; P<0.001). The median absolute error was 6%, and 72% of predictions were within 10% of the true value. Bias was not systematically worse at either extreme of the flow distribution. The prediction was found to be more accurate for either smaller and younger patients (age 0-2 years), for right ventricle injections, or when less cranial angulations were used (≤20°). In these cases (n=40), the prediction achieved R2=0.87, median absolute error of 5.5%, and 78% of predictions were within 10% of the true flow. CONCLUSIONS: The current study demonstrates the feasibility of a novel method for measuring relative lung perfusion using conventional angiograms. Real-time measurement of lung perfusion at the catheterization laboratory has the potential to reduce unnecessary testing, associated costs, and radiation exposure. Further optimization and validation is warranted.


Asunto(s)
Pulmón , Humanos , Recién Nacido , Lactante , Preescolar , Estudios Retrospectivos , Resultado del Tratamiento , Pulmón/diagnóstico por imagen , Pulmón/irrigación sanguínea , Perfusión , Fluoroscopía
2.
Ann Thorac Surg Short Rep ; 1(1): 40-45, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36909146

RESUMEN

Background: Transcatheter edge-to-edge valve repair (TEER) is a complex procedure requiring delivery and alignment of the device to the target valve, which can be challenging in atypical or surgically palliated anatomy. We demonstrate application of virtual and physical simulation to plan optimal TEER access and catheter path in normal and congenitally abnormal cardiac anatomy. Methods: Three heart models were created from three-dimensional (3D) images and 3D printed, including two with congenital heart disease. TEER catheter course was simulated both virtually and physically using a commercial TEER system. Results: We demonstrate application of modeling in three patients, including two with congenital heart disease and a Fontan circulation. Access site and pathway to device delivery was simulated by members of a multidisciplinary valve team. Virtual and physical simulation were compared. Conclusions: Virtual and physical simulation of TEER using 3D printed heart models is feasible and may be beneficial for planning and simulation, particularly in patients with complex anatomy. Future work is required to demonstrate application in the clinical setting.

3.
JTCVS Open ; 5: 48-60, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36003177

RESUMEN

Background: The exact geometric pathogenesis of leaflet tethering in ischemic mitral regurgitation (IMR) and the relative contribution of each component of the mitral valve complex (MVC) remain largely unknown. In this study, we sought to further elucidate mitral valve (MV) leaflet remodeling and papillary muscle dynamics in an ovine model of IMR with magnetic resonance imaging (MRI) and 3-dimensional echocardiography (3DE). Methods: Multimodal imaging combining 3DE and MRI was used to analyze the MVC at baseline, 30 minutes post-myocardial infarction (MI), and 12 weeks post-MI in ovine IMR models. Advanced 3D imaging software was used to trace the MVC from each modality, and the tracings were verified against resected specimens. Results: 3DE MV remodeling was regionally heterogenous and observed primarily in the anterior leaflet, with significant increases in surface area, especially in A2 and A3. The posterior leaflet was significantly shortened in P2 and P3. Mean posteromedial papillary muscle (PMPM) volume was decreased from 1.9 ± 0.2 cm3 at baseline to 0.9 ± 0.3 cm3 at 12 weeks post-MI (P < .05). At 12 weeks post-MI, the PMPM was predominately displaced horizontally and outward along the intercommissural axis with minor apical displacement. The subvalvular contribution to tethering is a combination of unilateral movement, outward displacement, and degeneration of the PMPM. These findings have led to a proposed new framework for characterizing PMPM dynamics in IMR. Conclusions: This study provides new insights into the complex interrelated and regionally heterogenous valvular and subvalvular mechanisms involved in the geometric pathogenesis of IMR tethering.