Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Leg Med (Tokyo) ; 68: 102436, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38492322

RESUMEN

Discovering a body displaying signs of multiple head trauma requires a thorough examination by the forensic pathologist, and a multidisciplinary approach is recommended. However, determining the manner of death is not always possible. We present a case in which the body of a 60-year-old man was discovered lying face down on the floor of his apartment, partially unclothed, surrounded by blood and vomit, and presenting numerous head injuries. The autopsy concluded that the cause of death was a result of post-traumatic brain injury. Nevertheless, applying current criteria made it challenging to ascertain whether the trauma stemmed from an accidental event or an assault.


Asunto(s)
Homicidio , Humanos , Masculino , Persona de Mediana Edad , Autopsia , Patologia Forense/métodos , Lesiones Traumáticas del Encéfalo/diagnóstico , Lesiones Accidentales/diagnóstico , Traumatismos Craneocerebrales/diagnóstico , Causas de Muerte , Accidentes , Reproducibilidad de los Resultados
2.
Adv Clin Exp Med ; 2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38411387

RESUMEN

BACKGROUND: In forensic toxicology, positive immunoassay (IA) test results do not hold forensic validity and need to be confirmed with mass spectrometry (MS). On the other hand, a negative result is a strong indication that the drug and/or the drug metabolites are not present in the sample and that confirmatory analyses are not necessary. Consequently, a negative IA result must have forensic validity since it can be admitted in court during a trial. OBJECTIVES: Screening cutoffs for the analysis of hair samples using immunoassays (IAs) were retrospectively optimized based on the Society of Hair Testing (SoHT) confirmation cutoffs and the utility of the test for forensic applications was discussed. MATERIAL AND METHODS: Hair samples taken from 150 patients with a history of drug addiction were analyzed with ILab 650, Werfen (Milan, Italy) using DRI® reagents. Confirmatory analyses were subsequently performed using the ACQUITY UPLC® System, Waters Corporation (Milford, USA). Screening cutoffs were retrospectively optimized using receiver operating characteristic (ROC) analysis. RESULTS: A total of 162 single positive results were obtained for confirmatory analysis (10 for amphetamines/methamphetamines, 11 for MDMA, 37 for cocaine, 40 for THC, 33 for methadone, and 31 for opiates). The optimized screening cutoffs were 0.27 IA ng/mg for amphetamines, 0.51 IA ng/mg for MDMA, 0.59 IA ng/mg for cocaine, 0.14 IA ng/mg for cannabinoids, 0.63 IA ng/mg for methadone, and 0.26 IA ng/mg for opiates. An area under the curve (AUC) greater than 0.95 was obtained with very high sensitivity and specificity for all drugs. CONCLUSIONS: The presented screening method proved to be a useful technique on hair samples for the classes of drugs most commonly found in Italy and Europe and can be applied to forensic analysis.

3.
Drug Test Anal ; 2024 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-38350637

RESUMEN

Synthetic cannabinoid receptor agonists (SCRAs) are one of the largest groups of new psychoactive substances (NPS). Yet, another novel analog started spreading on the NPS market around 2021. Soon after, the substance could be analytically characterized in herbal material as ADB-HEXINACA, an SCRA containing a hexyl-substituted tail on the indazole core. Here, we present suitable urinary markers to prove the consumption of this analog, a case report of acute polydrug intoxication and data on its prevalence in Germany. Anticipated phase I metabolites were detected in 12 authentic urine samples that were collected for abstinence control and analyzed by ultra-performance liquid chromatography coupled to a time-of-flight mass spectrometer (UPLC-qToF-MS). The results of in vivo samples were confirmed by analysis of in vitro incubates with pooled human liver microsomes (pHLMs). Forensic samples were used to assess the prevalence of ADB-HEXINACA. Thirty-two phase I metabolites were detected in the authentic urine samples. The main metabolites resulted from amide hydrolysis in combination with either monohydroxylation or ketone formation at the hexyl moiety (M15 and M26), the monitoring of which is recommended as a proof of consumption. ADB-HEXINACA was detected in 3.5% of SCRA positive urine samples collected for abstinence control in Freiburg up to December 2022 and in 5.5% of the SCRA positive blood/serum samples. The hexyl substituent of ADB-HEXINACA allows for the detection of specific urinary biomarkers suggested as analytical targets to confirm its prior intake. ADB-HEXINACA had a rather low prevalence in Germany, alternating months of higher prevalence with periods of total absence.

4.
J Pharm Biomed Anal ; 243: 116054, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38422647

RESUMEN

INTRODUCTION: In the dynamic universe of new psychoactive substances (NPS), the identification of multiple and chemically diverse compounds remains a challenge for forensic laboratories. Since hair analysis represents a gold-standard to assess the prevalence of NPS, which are commonly detected together with classical drugs of abuse (DoA), our study aimed at developing a wide-screen method to detect and quantify 127 NPS and 15 DoA on hair. MATERIALS AND METHODS: A multi-analyte ultra-high performance liquid chromatography mass spectrometry method for the identification and quantification of 127 NPS (phenethylamines, arylcyclohexylamines, synthetic opioids, tryptamines, synthetic cannabinoids, synthetic cathinones, designer benzodiazepines) and 15 DoA in hair samples was developed. A full validation was performed according to the European medicines Agency (EMA) guidelines, by assessing selectivity, linearity, accuracy, precision, limit of quantification (LOQ), limit of detection (LOD), matrix effect and recovery. As a proof of the applicability, the method was applied to 22 authentic hair samples collected for forensic purposes. RESULTS: Successful validation was achieved, by meeting the required technical parameters, for 137 compounds (122 NPS and 15 DoA), with LOQ set at 4 pg/mg for 129 compounds, at 10 pg/mg for 6 and at 40 pg/mg for 2. The method was not considered validated for 5 NPS, as LLOQ resulted too high for a forensic analysis (80 pg/mg). Among authentic forensic samples, 17 tested positive for DoA, and 10 to NPS, most samples showing positivity for both. Detected NPS were ketamine and norketamine, 5-MMPA, ritalinic acid, methoxyacetyl fentanyl, methylone and RCS-4. CONCLUSION: The present methodology represents an easy, low cost, wide-panel method for the quantification of 122 NPS and 15 DoA, for a total of 137 analytes, in hair samples. The method can be profitably applied by forensic laboratories. Similar multi-analyte methods on the hair matrix might be useful in the future to study the prevalence of NPS and the co-occurrence of NPS-DoA abuse.


Asunto(s)
Cannabinoides , Drogas Ilícitas , Trastornos Relacionados con Sustancias , Humanos , Detección de Abuso de Sustancias/métodos , Drogas Ilícitas/análisis , Analgésicos Opioides/análisis , Cannabinoides/análisis , Cabello/química
5.
Sensors (Basel) ; 24(2)2024 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-38257593

RESUMEN

BACKGROUND: Anthropometric measurements play a crucial role in medico-legal practices. Actually, several scanning technologies are employed in post-mortem investigations for forensic anthropological measurements. This study aims to evaluate the precision, inter-rater reliability, and accuracy of a handheld scanner in measuring various body parts. METHODS: Three independent raters measured seven longitudinal distances using an iPad Pro equipped with a LiDAR sensor and specific software. These measurements were statistically compared to manual measurements conducted by an operator using a laser level and a meterstick (considered the gold standard). RESULTS: The Friedman test revealed minimal intra-rater variability in digital measurements. Inter-rater variability analysis yielded an ICC = 1, signifying high agreement among the three independent raters. Additionally, the accuracy of digital measurements displayed errors below 1.5%. CONCLUSIONS: Preliminary findings demonstrate that the pairing of LiDAR technology with the Polycam app (ver. 3.2.11) and subsequent digital measurements with the MeshLab software (ver. 2022.02) exhibits high precision, inter-rater agreement, and accuracy. Handheld scanners show potential in forensic anthropology due to their simplicity, affordability, and portability. However, further validation studies under real-world conditions are essential to establish the reliability and effectiveness of handheld scanners in medico-legal settings.


Asunto(s)
Antropología Forense , Investigadores , Humanos , Reproducibilidad de los Resultados , Autopsia , Programas Informáticos
6.
Leg Med (Tokyo) ; 67: 102398, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38237384

RESUMEN

The World Health Organization recently presented the priorities for tackling abuse of older people in a coordinated and strategic way. However, data on the forensic scenario is still lacking. In this context, the aim of the present work was to provide a comprehensive literature review of this inherently complex phenomenon in the post-mortem setting, in order to better characterize it from a forensic point of view. A comprehensive literature search was performed in three electronic databases following the PRISMA guidelines. Sociodemographic and medical data of victims and perpetrators, post-mortem data, types of abuse and risk factors were extracted from non-aggregated data. Forty-eight papers dealing with abuse in the post-mortem setting were included, with a predominance of case reports and case series. The review showed that neglect was the most common type of abuse and victims are predominantly older women who are abused in a domestic setting by trusted family member. To generate more and better data, expanded research in the forensic field requires standardized methods and the raise of professional awareness about abuse of older people.


Asunto(s)
Abuso de Ancianos , Humanos , Femenino , Anciano , Autopsia , Factores de Riesgo , Familia
7.
Forensic Toxicol ; 42(1): 82-92, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37300633

RESUMEN

PURPOSE: We report a case of a polydrug user who consumed various synthetic cannabinoids and fentanyl from a transdermal patch via a bucket bong. Toxicological results from postmortem matrices with special focus on synthetic cannabinoids are discussed in terms of their relevance to the death. METHODS: The samples were analyzed by toxicological screening procedures involving immunoassays and gas chromatography-mass spectrometry (GC-MS) as well as quantitative analyses by means of GC-MS and high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). RESULTS: At the autopsy, coronary artery disease and signs of liver congestion were noted, in the absence of acute myocardial ischemic changes. Femoral blood concentrations of fentanyl and pregabalin were 14 ng/mL and 3,200 ng/mL, respectively. In addition, 2.7 ng/mL 5F-ADB and 13 ng/mL 5F-MDMB-P7AICA were detected together with relatively low amounts of 5 other synthetic cannabinoids in cardiac blood. A total number of up to 17 synthetic cannabinoids were detected in kidney, liver, urine and hair. Fentanyl and 5F-ADB were also detected in the water of the bucket bong. CONCLUSIONS: The cause of death could be attributed to an acute mixed intoxication by fentanyl and 5F-ADB (both Toxicological Significance Score (TSS) = 3) with a contribution of pregabalin and 5F-MDMB-P7AICA (TSS = 2), in a subject suffering from pre-existing heart damage. The most plausible mechanism of death consists in a respiratory depression. This case report demonstrates that use of opioids in combination with synthetic cannabinoids might be particularly dangerous.


Asunto(s)
Cannabinoides , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Fentanilo , Pregabalina , Cannabinoides/análisis , Fumar
8.
Drug Test Anal ; 16(2): 221-235, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37376716

RESUMEN

As a consequence of recently implemented legal restrictions on fentanyl analogs, a new generation of acylpiperazine opioids appeared on the illicit drug market. AP-238 was the latest opioid in this series to be notified by the European Early Warning System in 2020 and was involved in an increasing number of acute intoxications. AP-238 metabolism was investigated to provide useful markers of consumption. For the tentative identification of the main phase I metabolites, a pooled human liver microsome assay was performed. Further, four whole blood and two urine samples collected during post-mortem examinations and samples from a controlled oral self-administration study were screened for anticipated metabolites. In total, 12 AP-238 phase I metabolites were identified through liquid chromatography-quadrupole time-of-flight mass spectrometry in the in vitro assay. All of these were confirmed in vivo, and additionally, 15 phase I and five phase II metabolites were detected in the human urine samples, adding up to a total of 32 metabolites. Most of these metabolites were also detected in the blood samples, although mostly with lower abundances. The main in vivo metabolites were built by hydroxylation combined with further metabolic reactions such as O-methylation or N-deacylation. The controlled oral self-administration allowed us to confirm the usefulness of these metabolites as proof of intake in abstinence control. The detection of metabolites is often crucial to documenting consumption, especially when small traces of the parent drug can be found in real samples. The in vitro assay proved to be suitable for the prediction of valid biomarkers of novel synthetic opioid intake.


Asunto(s)
Analgésicos Opioides , Drogas Ilícitas , Humanos , Analgésicos Opioides/metabolismo , Detección de Abuso de Sustancias/métodos , Drogas Ilícitas/química , Microsomas Hepáticos/metabolismo , Fentanilo
9.
J Forensic Sci ; 69(1): 205-212, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37877199

RESUMEN

The role of forensic science can be defined as providing relevant opinions to assist investigators and courts of law in answering questions. The Likelihood Ratio (LR) provides a quantitative and logical approach to communicating the strength of expert evidence. We reviewed existing forensic literature on sharp force fatalities, focusing on studies reporting the manner of death and the frequency of some characteristics that are traditionally assessed. Four studies were included, resulting in a database of 173 suicides and 354 homicides. The LR of each of the characteristic under both hypotheses (suicide and homicide) was obtained. Subsequently, the LR was computed in six fatalities with known manner of death, three suicides and three homicides, by multiplying the corresponding LR of each individual characteristic. LR ranged from 115 to 140,250 in suicidal cases and from 9 to 2728 in homicidal cases. Compared to other fields of forensic science where LR is used extensively, the values obtained in our cases of sharp force fatalities is low. However, in forensic pathology there is evidence that is outside the expert's opinion, and it is for the trier of fact, such as the judge or jury, to draw conclusions. Nevertheless, the LR serves as a tool for interpreting and weighing evidence while maintaining the distinct roles of the trier of fact and the expert. To comprehensively apply the LR in the field of sharp force deaths, it will be necessary to standardize the methodology of investigation and data collection in descriptive studies.


Asunto(s)
Suicidio , Humanos , Homicidio , Patologia Forense , Recolección de Datos , Distribución por Edad , Causas de Muerte
10.
Drug Test Anal ; 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-38145896

RESUMEN

External contamination of hair by cannabis smoking requires a careful evaluation in forensic toxicology. Medical and recreational cannabis are increasingly consumed by e-cigarettes, which give rise to side-stream vapor. Moreover, products containing low Δ9-tetrahydrocannabinol (Δ9-THC) and rich in cannabidiol (CBD) started spreading legally. The goal of the present study was to assess whether hair analysis could allow to distinguish the type of delivered product, with low or high Δ9-THC, and the delivering mode, by smoking or vaping. Contamination of blank hair was mimicked by in vitro exposure to low- (0.4%) and high-Δ9-THC (9.7%) products delivered by smoking and vaping within a small confined system. Cannabis vaping extracts were prepared to deliver identical target Δ9-THC doses. Eighty samples were analyzed by ultrahigh-performance liquid chromatography mass spectrometry and quantified for Δ9-THC and CBD. After contamination by cannabis smoking, THC levels were in line with past in vitro and in vivo studies. Samples exposed to cannabis (169.30 ng/mg) showed significantly higher Δ9-THC than hair exposed to "light cannabis" (35.54 ng/mg), and the opposite was seen for the CBD/Δ9-THC ratio. Hair contaminated by vaping or smoking did not show a statistically different Δ9-THC content. Under our in vitro conditions, hair analysis might allow to discriminate whether external contamination is determined by products containing low or high Δ9-THC, but not the delivering mode. More research is needed in real-life conditions, to see whether the same also applies to the interpretation of forensic casework.

12.
Artículo en Inglés | MEDLINE | ID: mdl-37796377

RESUMEN

Young individuals constitute an intriguing population, as their drinking habits are notably shaped by their perception of their peers' alcohol consumption. Nonetheless, excessive alcohol intake can have detrimental effects on academic performance, interpersonal relationships, and the risk and severity of accidents. This study reported the first data involving students enrolled from three universities on a voluntary basis for alcohol consumption evaluation. Alcohol consumption was assessed through questionnaires and EtG quantification in hair (hEtG) carried out by liquid chromatography-mass spectrometry (LC-MS/MS) analysis after a solid-phase extraction (SPE) purification step. The results of our study demonstrated that 77.1% of samples tested negative for hEtG or displayed hEtG ≤ 5 pg/mg. Particularly, the student population was not characterized by samples with hEtG indicative of chronic excessive consumption (hEtG ≥ 30 pg/mg). No significant association was identified between biological sex, among the degree course/the year attended, nor in relation to BMI or smoking/coffee consumption. Among the obtained results, it was worth noting that the comparison of self-reporting abstinence from tobacco and coffee accounted for 65.3% and 16.7%, respectively, while only 2.8% of the total declared abstinence from alcohol. The current study has uncovered a significant level of interest among students in this analysis and its interpretation. This suggests that implementing public health promotion activities within a university setting could be beneficial.

13.
Genes (Basel) ; 14(6)2023 06 15.
Artículo en Inglés | MEDLINE | ID: mdl-37372445

RESUMEN

Sudden cardiac death (SCD) is an unexpected natural death due to cardiac causes, usually happening within one hour of symptom manifestation or in individuals in good health up to 24 h before the event. Genomic screening has been increasingly applied as a useful approach to detecting the genetic variants that potentially contribute to SCD and helping the evaluation of SCD cases in the post-mortem setting. Our aim was to identify the genetic markers associated with SCD, which might enable its target screening and prevention. In this scope, a case-control analysis through the post-mortem genome-wide screening of 30 autopsy cases was performed. We identified a high number of novel genetic variants associated with SCD, of which 25 polymorphisms were consistent with a previous link to cardiovascular diseases. We ascertained that many genes have been already linked to cardiovascular system functioning and diseases and that the metabolisms most implicated in SCD are the lipid, cholesterol, arachidonic acid, and drug metabolisms, suggesting their roles as potential risk factors. Overall, the genetic variants pinpointed herein might be useful markers of SCD, but the novelty of these results requires further investigations.


Asunto(s)
Muerte Súbita Cardíaca , Humanos , Autopsia , Muerte Súbita Cardíaca/etiología
14.
Metabolites ; 13(5)2023 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-37233702

RESUMEN

In toxicogenetics, an integrative approach including the prediction of phenotype based on post-mortem genotyping of drug-metabolising enzymes might help explain the cause of death (CoD) and manner of death (MoD). The use of concomitant drugs, however, might lead to phenoconversion, a mismatch between the phenotype based on the genotype and the metabolic profile actually observed after phenoconversion. The aim of our study was to evaluate the phenoconversion of CYP2D6, CYP2C9, CYP2C19, and CYP2B6 drug-metabolising enzymes in a series of autopsy cases tested positive for drugs that are substrates, inducers, or inhibitors of these enzymes. Our results showed a high rate of phenoconversion for all enzymes and a statistically significant higher frequency of poor and intermediate metabolisers for CYP2D6, CYP2C9, and CYP2C19 after phenoconversion. No association was found between phenotypes and CoD or MoD, suggesting that, although phenoconversion might be useful for a forensic toxicogenetics approach, more research is needed to overcome the challenges arising from the post-mortem setting.

15.
Am J Forensic Med Pathol ; 44(2): 83-89, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37010986

RESUMEN

ABSTRACT: Ten lesions were photographed with an entry-level (HUAWEI P smart 2019), a midrange (Samsung Galaxy S8) and a high range (Apple Iphone XR) smartphone camera and with a digital single-lens camera (DSLC). Images were independently rated by 3 pathologists, based on comparison to the real lesion and "visual impact." Difference of perceptual lightness coordinates between smartphones and the criterion standard (DSLC) was calculated.The highest ranking for adherence to reality was obtained with DSLC, while the highest ranking for visual impact was obtained with the Iphone. The color representation better reflecting the criterion standard (DSLC) was obtained for the entry-level smartphone.All the devices allow to assess the general features (ie, the color, the shape, and the main characteristics) of an injury during a forensic autopsy. However, results might be different when photos are obtained in suboptimal, such as low-light, conditions. Moreover, images acquired through a smartphone camera might be unsuitable for later image exploitation, such as enlargement of a portion of the image to magnification of a detail, which seemed not relevant when the photo was shot. Only a raw image, acquired using a dedicated camera and deactivating images manipulation software, might allow the preservation of the true data.


Asunto(s)
Fotograbar , Teléfono Inteligente , Humanos , Proyectos Piloto , Fotograbar/métodos , Autopsia
16.
Microorganisms ; 11(4)2023 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-37110434

RESUMEN

Fetal inflammatory response syndrome (FIRS) represents the fetal inflammatory reaction to intrauterine infection or injury, potentially leading to multiorgan impairment, neonatal mortality, and morbidity. Infections induce FIRS after chorioamnionitis (CA), defined as acute maternal inflammatory response to amniotic fluid infection, acute funisitis and chorionic vasculitis. FIRS involves many molecules, i.e., cytokines and/or chemokines, able to directly or indirectly damage fetal organs. Therefore, due to FIRS being a condition with a complex etiopathogenesis and multiple organ dysfunction, especially brain injury, medical liability is frequently claimed. In medical malpractice, reconstruction of the pathological pathways is paramount. However, in cases of FIRS, ideal medical conduct is hard to delineate, due to uncertainty in diagnosis, treatment, and prognosis of this highly complex condition. This narrative review revises the current knowledge of FIRS caused by infections, maternal and neonatal diagnosis and treatments, the main consequences of the disease and their prognoses, and discusses the medico-legal implications.

17.
Drug Alcohol Depend ; 247: 109888, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37120918

RESUMEN

BACKGROUND: Several new Synthetic Cannabinoids have appeared each year since their introduction into the illicit drug market as recreational drugs. Among these, naphtalen-1-yl-(1-pentylindol-3-yl) methanone (JWH-018) is one of the most detected compounds in biological samples from patients involved in intoxication or death cases. Furthermore, consumption of JWH-018 has been linked to several cases of Driving Under the Influence of Drugs (DUID) suggesting that effects induced by this compound can affect individuals' ability to drive. METHODS: Given the high spread of polydrug consumption and the wide number of alcohol-related traffic accidents, this study aims to investigate the acute effects induced by co-administration of JWH-018 with ethanol on sensorimotor and motor responses, grip strength and memory functions in CD-1 male mice. Acute impairments induced by JWH-018 and ethanol alone have also been investigated, in order to compare their effects with that induced by their concurrent administration. RESULTS: In vivo behavioral experiments revealed a worsening of the cognitive and sensorimotor disruption after the co-administration of JWH-018 with ethanol compared to single compounds. CONCLUSIONS: These animal-based findings suggest a potential increased impairment on psychomotor performances which could be related to driving abilities posed by poly-drug consumption involving SCs and ethanol.


Asunto(s)
Cannabinoides , Conducir bajo la Influencia , Drogas Ilícitas , Masculino , Animales , Ratones , Preparaciones Farmacéuticas , Etanol/efectos adversos , Drogas Ilícitas/farmacología
19.
Front Psychiatry ; 14: 1131335, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36911125

RESUMEN

Objective: To determine whether the acute co-consumption of ethanol and synthetic cannabinoids (SCs) increases the risk of a motor vehicle collision and affects the psychomotor performances relevant for driving. Design: Systematic review of the literature. Data sources: Electronic searches were performed in two databases, unrestricted by year, with previously set method and criteria. Search, inclusion and data extraction were performed by two blind authors. Results: Twenty articles were included, amounting to 31 cases of SCs-ethanol co-consumption. The impairment of psychomotor functions varied widely between studies, ranging from no reported disabilities to severe unconsciousness. Overall, a dose-effect relationship could not be observed. Conclusion: Despite the biases and limitations of the literature studies, it seems likely that the co-consumption poses an increased risk for driving. The drugs might exert a synergistic effect on the central nervous system depression, as well as on aggressiveness and mood alterations. However, more research is needed on the topic.

20.
J Pharm Biomed Anal ; 228: 115315, 2023 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-36889130

RESUMEN

We report a rapid and sensitive LC-MS/MS method that allows the simultaneous detection of 68 commonly prescribed antidepressants, benzodiazepines, neuroleptics, and metabolites in whole blood with a small sample volume after a rapid protein precipitation. The method was also tested on post-mortem blood from 85 forensic autopsies. Three sets of commercial serum calibrators containing a mix of prescription drugs of increasing concentration were spiked with red blood cells (RBC) to obtain 6 calibrators (3 "serum calibrators" and 3 "blood calibrators"). Curves obtained from serum calibrators and from blood calibrators were compared using a Spearman correlation test and by analyzing slopes and intercepts, to assess if the points from six calibrators could be plotted together in a single calibration model. The validation plan included interference studies, calibration model, carry-over, bias, within-run and between-run precision, limit of detection (LOD), limit of quantification (LOQ), matrix effect and dilution integrity. Four deuterated Internal Standards (Nordiazepam-D5, Citalopram-D6, Ketamine-D4 and Amphetamine-D5) and two different dilutions were assessed. Analyses were performed using an Acquity UPLC® System coupled with triple quadrupole detector Xevo TQD®. The degree of agreement with a previously validated method was calculated on whole blood samples of 85 post-mortem cases, by performing a Spearman correlation test with a Bland-Altman plot. Percentage error between the two methods was evaluated. Slopes and intercepts of curves obtained from serum calibrators and from blood calibrators showed a good correlation, and the calibration model was built plotting all points together. No interferences were found. The calibration curve appeared to provide a better fit of the data using an unweighted linear model. Negligible carry-over was observed, and very good linearity, precision, bias, matrix effect and dilution integrity were achieved. The LOD and the LOQ were at the lower limits of the therapeutic range for the tested drugs. In a series of 85 forensic cases, 11 antidepressants, 11 benzodiazepines and 8 neuroleptics were detected. For all analytes, a very good agreement between the new method and the validated method was demonstrated. The innovation of our method consists in the use of commercial calibrators, readily available to most forensic toxicology laboratories, for the validation of a fast, inexpensive, wide-panel LC-MS/MS method that can be used as a reliable and accurate screening for psychotropic drug in postmortem samples. As observed in the implementation on real cases, this method could be profitably applied in forensic cases.


Asunto(s)
Antipsicóticos , Espectrometría de Masas en Tándem , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Autopsia , Psicotrópicos , Límite de Detección , Antidepresivos , Anfetamina , Benzodiazepinas , Toxicología Forense/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...