Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Eat Weight Disord ; 26(2): 449-455, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32072572

RESUMEN

OBJECTIVES: The main focus of this study was to evaluate the prevalence of food addiction (FA) in a population of 575 subjects, all affected by drugs, alcohol and/or tobacco addiction. METHODS: Patients were enrolled in Addiction Service Centers and 25 items YFAS questionnaire was administered. Prevalence of FA was studied among patients who already have an addiction and then this prevalence was compared between groups of abusers (by type of substance), comparing mono abusers with polyabusers, as well as regressions by age, BMI, sex, through multiple regression analysis. RESULTS: Prevalence of FA in the sample is 20.17%. Risk of FA increases with the number of substances used (polyabuse). Results show a positive correlation, in addicted people, between BMI values and FA, with significant values (OR 1.08; 95% CI 1.04-1.13; p = 0.006). Age is inversely correlated with FA (OR 0.97; 95% CI 0.95-0.99; p = 0.01). Female sex is positively associated (OR 2.60; 95% CI 1.59-4.27, p = 0.000). No significant association appears with any substance, even if the highest prevalence is recorded among cannabis users (31.03%), and heroin (21.07%), followed by cocaine (18.53%), alcohol (14.49%) and tobacco (11.61%). A comparison between the FA prevalence in our study and that from another study in the Italian general population (11%) shows a significant difference (p < 0.001). CONCLUSIONS: Prevalence of FA among addicted people is greater than in the general population. Risk of FA increases with the increase in number of used substances (polyabuse). Age is inversely correlated with FA. There is a positive and significant correlation between BMI and FA among substance/tobacco abusers. LEVEL OF EVIDENCE: Level V, observational cross-sectional descriptive study.


Asunto(s)
Adicción a la Comida , Preparaciones Farmacéuticas , Estudios Transversales , Femenino , Adicción a la Comida/epidemiología , Humanos , Italia , Prevalencia , Nicotiana
2.
J Biol Regul Homeost Agents ; 33(2 Suppl. 1): 51-56. XIX Congresso Nazionale S.I.C.O.O.P. Societa' Italiana Chirurghi Ortopedici Dell'ospedalita' Privata Accreditata, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31169003

RESUMEN

Posterior cruciate ligament rupture is a rare knee ligamentous injury in skeletally immature patients with unfused growth plates. Despite being very uncommon, it still represents a significant challenge in terms of decision-making and treatment choice. The purpose of this case series was to report subject and objective outcomes (IKDC, TAS,LYSHOLM,KT2000) after PCL reconstruction in two teenage elite football players aged 15 and 16 respectively, who underwent surgical repair in July 2017 using for the femoral and tibial fixation of the PCL graft (hamstring tendons) respectively a curve cross-pin system and interferential screw. At fifteen months follow up, both athletes had returned to normal, pre-injury, competing levels with no leg discrepancy.


Asunto(s)
Traumatismos de la Rodilla/cirugía , Reconstrucción del Ligamento Cruzado Posterior , Tendones/cirugía , Adolescente , Atletas , Fémur , Estudios de Seguimiento , Humanos , Tibia , Resultado del Tratamiento
3.
Biosens Bioelectron ; 140: 111340, 2019 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-31154254

RESUMEN

The generation of physiologically relevant in-vitro models of biological barriers can play a key role in understanding human diseases and in the development of more predictive methods for assessing toxicity and drug or nutrient absorption. Here, we present an advanced cell culture system able to mimic the dynamic environment of biological barriers while monitoring cell behaviour through real-time impedance measurements and imaging. It consists of a fluidic device with an apical and a basal flow compartment separated by a semi-permeable membrane. The main features of the device are the integration of sensing through transepithelial electrical impedance (TEEI) measurements and transparent windows for optical monitoring within a dual flow system. Caco-2 cells were cultured in the TEEI bioreactor under both flow and static conditions. Although no differences in the expression of peripheral actin and occludin were visible, the cells in dynamic conditions developed higher impedance values at low frequencies, indicative of a higher paracellular electrical impedance with respect to the static cultures. TEEI measurements at high frequency also enabled monitoring monolayer formation, which can be correlated with the observation of an RC behaviour in the impedance spectra. In particular, the cells subject to flow showed accelerated barrier formation and increased vitality with respect to the static controls, again highlighting the importance of dynamic conditions for epithelial cells.


Asunto(s)
Técnicas Biosensibles/instrumentación , Técnicas de Cultivo de Célula/instrumentación , Impedancia Eléctrica , Células Epiteliales/citología , Reactores Biológicos , Células CACO-2 , Supervivencia Celular , Simulación por Computador , Diseño de Equipo , Humanos , Hidrodinámica , Modelos Biológicos , Imagen Óptica/instrumentación
4.
Am J Physiol Renal Physiol ; 315(6): F1833-F1842, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-30207172

RESUMEN

The p66ShcA protein controls cellular responses to oxidative stress, senescence, and apoptosis. Here, we test the hypothesis that aging phenotype(s) commonly associated with the broad category of chronic kidney disease are accelerated in diabetic kidneys and linked to the p66ShcA locus. At the organ level, tissue stem cells antagonize senescent phenotypes by replacing old dysfunctional cells. Using established methods, we isolated a highly purified population of stem cell antigen-1-positive mesenchymal stem cells (Sca-1+ MSCs) from kidneys of wild-type (WT) and p66 knockout (p66 KO) mice. Cells were plated in culture medium containing normal glucose (NG) or high glucose (HG). Reactive oxygen species (ROS) metabolism was substantially increased in WT MSCs in HG medium in association with increased cell death by apoptosis and acquisition of the senescent phenotype. DNA microarray analysis detected striking differences in the expression profiles of WT and p66 KO-MSCs in HG medium. Unexpectedly, the analysis for p66 KO-MSCs revealed upregulation of Wnt genes implicated in self-renewal and differentiation. To test the in vivo consequences of constitutive p66 expression in diabetic kidneys, we crossed the Akita diabetic mouse with the p66KO mouse. Homozygous mutation at the p66 locus delays or prevents aging phenotype(s) in the kidney that may be precursors to diabetic nephropathy.


Asunto(s)
Envejecimiento/metabolismo , Nefropatías Diabéticas/metabolismo , Riñón/metabolismo , Células Madre Mesenquimatosas/metabolismo , Proteína Transformadora 1 que Contiene Dominios de Homología 2 de Src/metabolismo , Factores de Edad , Envejecimiento/genética , Envejecimiento/patología , Animales , Apoptosis , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Senescencia Celular , Nefropatías Diabéticas/genética , Nefropatías Diabéticas/patología , Modelos Animales de Enfermedad , Glucosa/metabolismo , Riñón/patología , Células Madre Mesenquimatosas/patología , Ratones Noqueados , Fenotipo , Especies Reactivas de Oxígeno/metabolismo , Proteína Transformadora 1 que Contiene Dominios de Homología 2 de Src/deficiencia , Proteína Transformadora 1 que Contiene Dominios de Homología 2 de Src/genética , Nicho de Células Madre , Vía de Señalización Wnt
5.
Biotechnol Bioeng ; 106(1): 127-37, 2010 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-20091740

RESUMEN

A generic "system on a plate" modular multicompartmental bioreactor array which enables microwell protocols to be transferred directly to the bioreactor modules, without redesign of cell culture experiments or protocols is described. The modular bioreactors are simple to assemble and use and can be easily compared with standard controls since cell numbers and medium volumes are quite similar. Starting from fluid dynamic and mass transport considerations, a modular bioreactor chamber was first modeled and then fabricated using "milli-molding," a technique adapted from soft lithography. After confirming that the shear stress was extremely low in the system in the range of useful flow rates, the bioreactor chambers were tested using hepatocytes. The results show that the bioreactor chambers can increase or maintain cell viability and function when the flow rates are below 500 microL/min, corresponding to wall shear stresses of 10(-5) Pa or less at the cell culture surface.


Asunto(s)
Reactores Biológicos , Estrés Mecánico , Animales , Técnicas de Cultivo de Célula , Supervivencia Celular , Células Cultivadas , Hepatocitos/fisiología , Ratas
6.
J Neuroendocrinol ; 20(3): 375-80, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18208555

RESUMEN

The neuroprotective effects of oestrogens have been demonstrated against a variety of insults, including excitotoxicity, oxidative stress and cerebral ischemia under certain conditions. However, the molecular mechanisms underlying oestrogen neuroprotection are still unclear. We aimed to determine whether 17beta-oestradiol (E(2)) administration post-hypoxia (p-hx) was neuroprotective and whether these actions were mediated through oestrogen receptors (ER). For this purpose, 12-embyonic day-old chickens were subjected to acute hypoxia [8% (O(2)), 60 min], followed by different reoxygenation periods. To test the neuroprotective effect of E(2) and its mechanism, embryos were injected 30 min after the end of hypoxia with E(2) alone or with ICI 182 780, a competitive antagonist of ER. Cytochrome c (cyt c) release, an indicator of mitochondrial apoptotic pathway, was measured by western blot in optic lobe cytosolic extracts. DNA fragmentation by TUNEL fluorescence and caspase-3 fragmentation by immunofluorescence were detected on optic lobe sections. Acute hypoxia produces a significant increase in cyt c release from mitochondria at 4 h p-hx, followed by an increase in TUNEL positive cells 2 h later (6 h p-hx). Administration of E(2) (0.5 mg/egg) produced a significant decrease in cytosolic cyt c levels at 4 h p-hx, in caspase-3 activation and in TUNEL positive cells at 6 h p-hx compared to vehicle treated embryos. In the E(2)-ICI 182 780 treated embryos, cyt c release, caspase-3 fragmentation and TUNEL positive cells were similar to the hypoxic embryos, thus suggesting the requirement of an E(2)-ER interaction for E(2) mediated neuroprotective effects. In conclusion, E(2) prevents hypoxia-induced cyt c release and posterior cell death and these effects are mediated by oestrogen receptors.


Asunto(s)
Apoptosis , Hipoxia de la Célula/fisiología , Sistema Nervioso Central/crecimiento & desarrollo , Sistema Nervioso Central/metabolismo , Estradiol/farmacología , Receptores de Estrógenos/fisiología , Animales , Apoptosis/efectos de los fármacos , Muerte Celular/efectos de los fármacos , Hipoxia de la Célula/efectos de los fármacos , Sistema Nervioso Central/efectos de los fármacos , Embrión de Pollo , Citocromos c/metabolismo , Fragmentación del ADN/efectos de los fármacos , Evaluación Preclínica de Medicamentos , Fármacos Neuroprotectores/farmacología , Transporte de Proteínas/efectos de los fármacos , Receptores de Estrógenos/metabolismo
7.
Radiol Med ; 112(1): 74-81, 2007 Feb.
Artículo en Inglés, Italiano | MEDLINE | ID: mdl-17310289

RESUMEN

PURPOSE: We assessed the value of image fusion in the staging of prostatic cancer in a series of 32 patients who underwent preoperative evaluation with transrectal colour-Doppler ultrasonography (TRUS) and magnetic resonance imaging (MRI). MATERIALS AND METHODS: Colour-Doppler TRUS exams were performed using a 7.5-MHz biplanar probe. MRI exams were done with a scanner operating at 1.5 Tesla (T) using an endorectal coil. All patients underwent radical prostatectomy within 2 weeks from the imaging assessment. Whole-mount sections were prepared from the surgical specimens and were subsequently digitised by using a high-resolution scanner. The Digital Imaging and Communications in Medicine (DICOM) TRUS and MR images as well as the digitised pathological images were transferred to a graphic workstation to perform image fusion. RESULTS: Image fusion was technically possible in 25/32 cases in which axial TRUS images were available. The following fusion images were obtained: TRUS + pathological sections; MRI + pathological sections; TRUS + MRI + pathological sections. The final pathological staging concerning the T status was: four pT2b, fourteen pT2c, three pT3a and four pT3b. The three types of image fusion led to the following results: TRUS + pathological sections, correct staging in 20/25 cases (accuracy 80%); MRI + pathological sections, correct staging in 22/25 cases (accuracy 88%); TRUS + MRI + pathological sections, correct staging in 23/25 cases (accuracy 92%). CONCLUSIONS: Our study suggests that by using image fusion between colour-Doppler TRUS and endorectal MRI, it is possible to improve the accuracy of pathological staging in patients who are candidates for radical prostatectomy.


Asunto(s)
Carcinoma/patología , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/patología , Ultrasonografía Doppler en Color/métodos , Anciano , Carcinoma/diagnóstico por imagen , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Adhesión en Parafina , Valor Predictivo de las Pruebas , Antígeno Prostático Específico/análisis , Prostatectomía/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Vesículas Seminales/patología , Sensibilidad y Especificidad , Fijación del Tejido
8.
Dig Liver Dis ; 39(1): 87-90, 2007 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16787774

RESUMEN

We report on a case of pneumatosis cystoides intestinalis in a 32-year-old woman affected by coeliac disease with stool cultures positive for salmonella. After plain film of the abdomen, patient underwent computed tomography and magnetic resonance colonography studies that demonstrated numerous, diffuse bubblelike intramural gas collections into the ascending, transverse and descending colonic wall. CT and MR findings were correlated with colonoscopy.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neumatosis Cistoide Intestinal/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adulto , Antibacterianos/uso terapéutico , Enfermedad Celíaca/complicaciones , Colon Ascendente/diagnóstico por imagen , Colon Ascendente/patología , Colon Descendente/diagnóstico por imagen , Colon Descendente/patología , Colon Transverso/diagnóstico por imagen , Colon Transverso/patología , Colonoscopía , Medios de Contraste/administración & dosificación , Enema , Heces/microbiología , Femenino , Estudios de Seguimiento , Humanos , Oxigenoterapia Hiperbárica , Infusiones Intravenosas , Neumatosis Cistoide Intestinal/patología , Salmonella/aislamiento & purificación , Factores de Tiempo , Resultado del Tratamiento , Ácidos Triyodobenzoicos/administración & dosificación
9.
Eur Respir J ; 28(1): 174-81, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16816347

RESUMEN

After lung surgery, some patients complain of unexplained increased dyspnoea associated with hypoxaemia. This clinical presentation may be due to an interatrial right-to-left shunt despite normal right heart pressure. Some of these patients show postural dependency of hypoxaemia, whereas others do not. In this article, the pathogenesis and mechanisms involved in this post-surgical complication are discussed, and the techniques used for confirmation and localisation of shunt are reported. An invasive technique, such as right heart catheterisation with angiography, was often used in the past as the diagnostic procedure for the visualisation of interatrial shunt. As to noninvasive techniques, a perfusion lung scan may be used as the first approach as it may detect the effect of the right-to-left shunt by visualising an extrapulmonary distribution of the radioactive tracer. The 100% oxygen breathing test could also be used to quantify the amount of right-to-left shunt. Particular emphasis is given to newer imaging modalities, such as transoesophageal echocardiography, which is minimally invasive but highly sensitive in clearly visualising the atrial septum anatomy. Finally, the approach to closure of the foramen ovale or atrial septal defect is discussed. Open thoracotomy was the traditional approach in the past. Percutaneous closure has now become the most used and effective technique for the repair of the interatrial anatomical malformation.


Asunto(s)
Disnea/diagnóstico , Hipoxia/diagnóstico , Pulmón/cirugía , Procedimientos Quirúrgicos Pulmonares/efectos adversos , Anciano , Angiografía , Disnea/etiología , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/patología , Defectos del Tabique Interatrial/patología , Humanos , Hipoxia/etiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Prevalencia , Intercambio Gaseoso Pulmonar
10.
Dig Liver Dis ; 37(3): 200-5, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15888286

RESUMEN

A 45-year-old man presented with a 1-week history of gastrooesophageal reflux, epigastric discomfort and abdominal pain especially in the right hypochondrium. Abdominal ultrasonography, contrast-enhanced spiral computed tomography and magnetic resonance imaging of the abdomen were performed. Eventually, imaging findings were correlated with histopathological analysis, which confirmed the diagnosis of a 18 cm x 16 cm hepatocellular adenoma.


Asunto(s)
Adenoma de Células Hepáticas/diagnóstico , Neoplasias Hepáticas/diagnóstico , Adenoma de Células Hepáticas/diagnóstico por imagen , Adenoma de Células Hepáticas/patología , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
11.
Pediatr Med Chir ; 25(4): 266-8, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-15070269

RESUMEN

BACKGROUND: Survival of neonates with critical pulmonary obstruction depends on cardiac morphology and function but also on proper perinatal management. METHODS: Postnatal outcome of five neonates with critical pulmonary stenosis or pulmonary atresia detected in utero is reported. RESULTS: Right ventricular morphology and ratio between tricuspid and mitral annulus at Fetal Echocardiography were the most important prognostic parameters. Increasing severity of obstruction and of right ventricular hypoplasia was documented in two fetuses. CONCLUSION: Prenatal diagnosis was useful for planning delivery; we hypothesize that it can be of benefit on postnatal outcome. In selected cases, earlier delivery and relief of obstruction could have beneficial effect on prognosis.


Asunto(s)
Atresia Pulmonar/diagnóstico por imagen , Estenosis de la Válvula Pulmonar/diagnóstico por imagen , Ultrasonografía Prenatal , Femenino , Estudios de Seguimiento , Humanos , Recién Nacido , Embarazo , Pronóstico
12.
Ital Heart J ; 2(6): 475-7, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11453587

RESUMEN

A patient with a deletion in the DiGeorge/velocardiofacial chromosomal region in 22q11, underwent cardiac repair for truncus arteriosus with a separate origin of the pulmonary arteries. This patient presented with a severe coagulation disorder similar to that described in the Bernard-Soulier syndrome. Additional features included minor facial anomalies, transient hypocalcemia and renal failure. To the best of our knowledge, this is the third case of a severe bleeding disorder associated with 22q 11 deletion reported in the literature.


Asunto(s)
Síndrome de Bernard-Soulier/complicaciones , Cromosomas Humanos Par 22 , Cardiopatías Congénitas/complicaciones , Hemorragia/complicaciones , Deleción Cromosómica , Salud de la Familia , Humanos , Recién Nacido , Masculino
13.
J Interv Cardiol ; 14(3): 319-24, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12053391

RESUMEN

BACKGROUND: The STARFlex (SF) device is a CardioSEAL (CS) double-umbrella device that has been modified by the addition of a self-centering mechanism comprised of nitinol springs connected between the two umbrellas and a flexible core wire with a pin-pivoting connection. This paper compares the results of atrial septal defect (ASD) closure with CardioSEAL and STARFlex devices. PATIENTS AND METHODS: Between December 1996 and March 2000, 117 patients underwent ASD closure with CardioSEAL (n = 79) and STARFlex (n = 38). The mean age (17 years), weight (49 kg), and ASD size (15 mm) were similar in the two groups. The procedures were performed under general anesthesia with both fluoroscopic and transesophageal echocardiographic monitoring. IMMEDIATE RESULTS: The devices were successfully implanted in all patients. Ten patients had multiple ASDs. A single device was used in four patients (CardioSEAL in three, STARFlex in one), while a simultaneous placement of two CardioSEAL (one patient) or two STARFlex (five patients) were performed in six patients. The results are summarized as follows: [table: see text] Follow-Up Results: On follow-up clinical exam, electrocardiograms, chest X-rays, and echocardiograms were obtained at 1, 6, and 12 months. [table: see text] During follow-up there were no deaths, endocarditis, rhythm disturbances, or other complications. Arm fractures were observed almost exclusively with large CardioSEAL devices (40 mm, less frequently with 33 mm), and only in one 33-mm STARFlex device. There were no clinical complications related to fractures. CONCLUSIONS: The STARFlex device seems to offer better results than the CardioSEAL, with significantly lower rates of residual shunts and arm fractures.


Asunto(s)
Cateterismo Cardíaco , Embolización Terapéutica/instrumentación , Defectos del Tabique Interatrial/terapia , Adolescente , Estudios de Seguimiento , Humanos , Resultado del Tratamiento
14.
Cardiol Young ; 10(5): 519-26, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11049128

RESUMEN

In this review, we describe the experience from 13 European centres using the CardioSEAL and Starflex double umbrella devices to close interatrial communications within the oval fossa (so-called 'secundum' defects). Between October 1996 and April 1999, the procedure was attempted in 334 patients with a mean age of 12 years and a mean weight of 44kg. The mean measured stretched diameter of the defect was 15 mm. In the overall group, the defect was solitary in 245 patients (73%), multiple in 21 (6%), associated with an aneurysm of the flap valve in 15 (5 %), was represented by patency of the oval foramen in 44 (13%), and was a fenestration in a Fontan repair in 9 (3%). In all patients, the devices were inserted under general anesthesia, using fluoroscopic and transesophageal echocardiographic control. Implantation was achieved in 325 (97,3%). The device embolized within either a few minutes or a few hours in 13 patients (4%). Of these, uncomplicated surgical repair was undertaken in 10, while the device was retrieved in 3 using catheters and a second device was successfully implanted. Residual shunting was detected immediately after the procedure in 41% of the patients, with the incidence decreasing to 31% at discharge, 24% at 1 month, 21% at 6 months, and 20.5% at one year. During the period of follow-up, elective surgical repair became necessary in two patients, due to malposition of the device in one, and late embolization in the other. Fractures of arms were seen in 6.1 %, most commonly with the largest devices. All those with fractured arms of the device were asymptomatic, and no clinical complications related to the fractures were observed. There were no arrhythmias, endocarditis, valvar distortion, thromboembolic events, or other complications. After one year of follow-up, clinical success, defined as complete closure of the defect or presence of only a trivial leak, had been obtained in 92.5% of the patients. We conclude, therefore, that these devices produce excellent results when used to close defects of small to moderate size. Results are less than optimal, or else complications ensure, when attempts are made to close very large defects.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/terapia , Adolescente , Adulto , Anciano , Angiografía/métodos , Cateterismo Cardíaco/métodos , Niño , Preescolar , Ecocardiografía Transesofágica/métodos , Diseño de Equipo , Seguridad de Equipos , Europa (Continente) , Femenino , Estudios de Seguimiento , Humanos , Lactante , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
15.
Hepatology ; 31(1): 131-40, 2000 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10613738

RESUMEN

Focal adhesion kinase (FAK) is a widely expressed nonreceptor tyrosine kinase found in focal adhesions. FAK has been indicated as a point of convergence of other signaling pathways including platelet-derived growth factor (PDGF) receptors, and recently, FAK tyrosine phosphorylation has been shown to be stimulated by PDGF. In the present study we assessed the role of Ras as a possible intermediate protein regulating PDGF-induced FAK tyrosine phosphorylation in human hepatic stellate cells (HSCs), liver-specific pericytes primarily involved in the pathogenesis of liver fibrosis. For this purpose, cells were first subjected to retroviral-mediated gene transfer with a dominant-negative mutant of Ras (N17Ras). This resulted in a marked inhibition of PDGF-induced FAK tyrosine phosphorylation together with the expected reduction of PDGF-induced extracellular signal-regulated kinase activity (ERK). Afterward, the effects of pharmacological agents potentially affecting Ras isoprenylation were evaluated. PDGF-induced FAK tyrosine phosphorylation, ERK activity and intracellular calcium increase, as well as the biological effects of this growth factor, (i.e., mitogenesis and cell migration) were effectively blocked by GGTI-298, an inhibitor of geranylgeranyltransferase I. Inhibition of Ras processing obtained with FTI-277, an inhibitor of farnesyltransferase, resulted in detectable effects only at high doses. Taken together, these results establish that Ras operates as a protein-linking PDGF-beta receptor to FAK in human HSCs, and that signaling molecules requiring geranylgeranylation may also be involved in this process.


Asunto(s)
Moléculas de Adhesión Celular/metabolismo , Hígado/enzimología , Fosfotirosina/metabolismo , Factor de Crecimiento Derivado de Plaquetas/farmacología , Proteínas Tirosina Quinasas/metabolismo , Proteínas Proto-Oncogénicas p21(ras)/fisiología , Transferasas Alquil y Aril/antagonistas & inhibidores , Becaplermina , Calcio/metabolismo , Moléculas de Adhesión Celular/análisis , Células Cultivadas , Inhibidores Enzimáticos/farmacología , Farnesiltransferasa , Quinasa 1 de Adhesión Focal , Proteína-Tirosina Quinasas de Adhesión Focal , Humanos , Proteína Quinasa 1 Activada por Mitógenos/metabolismo , Mutación , Fosforilación , Prenilación de Proteína , Proteínas Tirosina Quinasas/análisis , Proteínas Proto-Oncogénicas c-sis , Proteínas Proto-Oncogénicas p21(ras)/genética , Receptores del Factor de Crecimiento Derivado de Plaquetas/análisis , Receptores del Factor de Crecimiento Derivado de Plaquetas/metabolismo , Transducción de Señal , Transfección , Fosfolipasas de Tipo C/metabolismo
16.
Cardiol Young ; 9(6): 585-91, 1999 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-10593268

RESUMEN

In recent years, percutaneous placement of stents has been used as an alternative to surgery or balloon angioplasty for the treatment of adults with peripheral pulmonary arterial stenosis. This therapy has also been proposed for children, but questions still remain about its indications in this group of patients. We describe here the results of intravascular placement of stents in a group of 29 patients, with a mean age of 12+/-7 (range 3-31) years and weighing 35+/-19 (range 11-74) kg. All were affected by postsurgical or congenital isolated pulmonary arterial stenosis, and have now been followed for 38+/-19 (range 6-65) months. The early hemodynamic results have been excellent, with a significant reduction of the pulmonary arterial systolic pressure, the systolic pressure gradient, and the ratio of systolic pressures in the pulmonary and systemic circuits, and with a significant increase of the diameter of the stented vessels in all the patients. Of the 29 patients, 24 have been recatheterized 18+/-10 months after the procedure, demonstrating the stability of the results, with a low incidence of late restenosis, this seen in only 1 patient (2%). Lung perfusion scanning, performed in 17 patients each year after the follow-up catheterization, has showed that the results are maintained at long-term follow-up (51+/-9 months).


Asunto(s)
Arteria Pulmonar/patología , Stents , Adolescente , Adulto , Niño , Preescolar , Constricción Patológica , Femenino , Estudios de Seguimiento , Hemodinámica , Humanos , Masculino , Circulación Pulmonar/fisiología , Relación Ventilacion-Perfusión
17.
Minerva Med ; 90(4): 143-5, 1999 Apr.
Artículo en Italiano | MEDLINE | ID: mdl-10518959

RESUMEN

Visceral arteries aneurysms are an uncommon pathology. Lienal artery (60%), hepatic (20%), superior mesenteric (5.9%) and tripod celiac (4%) are the most involved. Female predominance, portal hypertension, arteriosclerosis, pregnancy, traumatic and infective factors are the most remarkable etiopathogenetic factors. Portal hypertension with splenomegaly might be an important factor in the pathogenesis of intra- and extraparenchimal splenic artery aneurysms. Stress is laid on the importance of arteriography during portal hypertension in pregnancy as a preventive measure because the rupture of aneurysm of the splenic artery, despite laparotomy in emergency is often fatal, and of coeliac angiography prior to liver transplantation; if splenic artery aneurysm is found, ligation of the splenic artery should be performed at the time of transplantation to prevent possible rupture. The different roles of the imaging techniques used are examined.


Asunto(s)
Aneurisma/diagnóstico , Aneurisma/etiología , Hipertensión Portal/complicaciones , Arteria Esplénica , Anciano , Femenino , Humanos
19.
Ann Ist Super Sanita ; 34(1): 131-6, 1998.
Artículo en Italiano | MEDLINE | ID: mdl-9679351

RESUMEN

We report the results of 24,475 blood lead determinations (PbB) performed by the Occupational Toxicology Laboratory of Florence between 1976 and 1995. Biological monitoring was carried out in 383 factories localized in the districts of Florence, Prato, Pistoia, Lucca and Pisa. The most represented production fields were colouring ceramic factories, artistic ceramics, transfer-pictures for ceramics, glass factories, typographies, glass decoration factories, chemical factories. In twenty years, the median values of PbB decreased from 48 to 17 micrograms/100 ml in males and from 40 to 8 micrograms/100 ml in females. The 95 degrees centile ranged from 84 to 46 micrograms/100 ml for males and from 63 to 42 micrograms/100 ml for females. In the 1988-95 period, we observed an increase of both the 95 degrees centile and the maximal values because of the inclusion of data from workers employed in factories where the "decorazione a scavo" technique, which is characterized by elevated environmental lead concentrations, was used. In the period 1991-93, the ranges of PbB observed in glass decoration factories were 13-160 micrograms/100 ml for males and 4-80 micrograms/100 ml for females, respectively.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente , Industrias , Plomo/sangre , Exposición Profesional , Adolescente , Adulto , Cerámica , Industria Química , Monitoreo Epidemiológico , Femenino , Vidrio , Humanos , Italia/epidemiología , Plomo/efectos adversos , Plomo/análisis , Intoxicación por Plomo/epidemiología , Intoxicación por Plomo/prevención & control , Masculino , Persona de Mediana Edad , Enfermedades Profesionales/inducido químicamente , Enfermedades Profesionales/epidemiología , Enfermedades Profesionales/prevención & control , Edición
20.
Am J Ind Med ; 34(1): 65-72, 1998 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9617389

RESUMEN

Art glass manufacturing is one of the most interesting examples of exposure to complex mixtures. Among the raw materials used are silica sand, borax, carbonates, nitrates of Ca, Na, K, and a great number of compounds that are mainly oxides of As, Sb, Al, Zn, Cr, Ni, Sn, Se, Cd, Mn, Cu, Co, Fe, Nd, Er, Eu, and La. In six art glass factories that use As or Sb as fining agents, the exposure to these elements was investigated in 32 workers by means of environmental and biological monitoring. Analysis was conducted by atomic absorption spectrometry (AAS) and inductively coupled plasma mass spectrometry (ICP-MS). The results confirmed that As, which is the main carcinogen in glass production, reaches high air concentrations and is generally above the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value-time-weighted average (TLV-TWA) of 10 micrograms/m3. When partly substituted by antimonial compounds, As air concentrations dropped dramatically, while the air levels of Sb (which is considered less toxic but is classified as a class 2B carcinogen by IARC) were relatively low and below the ACGIH TLV-TWA of 500 micrograms/m3. Exposure to As and Sb also differed in the three types of jobs investigated: As was high in oven chargers, Sb was higher in batch mixers, and both elements were low in makers-formers. Eleven to 18 elements were detected: arsenic, Al, Ba, Sb, Pb, and Zn were the elements most frequently measured (in tens, and in some cases hundreds, of micrograms/m3), followed by B, Li, Mn, Se, Sn, Sr, Ce, La, and Nd (in micrograms or in some cases tens of micrograms/m3. The results of biological monitoring for As, Sb, and other elements were in agreement with environmental monitoring data. We concluded that multiple detection of elements is a useful tool (or the evaluation of exposure to complex mixtures such as those used in the art glass industry and that such detection also allows a more accurate evaluation of related epidemiological data.


Asunto(s)
Antimonio , Arsénico , Vidrio , Exposición Profesional , Monitoreo del Ambiente , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...