Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
J Endourol ; 38(7): 652-660, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38753723

RESUMEN

Robot-assisted surgery (RAS) has been integrated into clinical practice to overcome several limitations of conventional open or laparoscopic surgery. After the expiration of the long key patent period of Intuitive Surgical, various robotic systems (RSs) have been developed aiming at improving certain characteristics of the first robotic platform, the Da Vinci RS. This narrative review provides an overview of the current RSs used in urology along with the initial results from their application in urologic procedures. Nine robotic platforms are being analyzed regarding their unique characteristics as well as their efficacy, safety, feasibility, and outcomes in urologic, oncological, or non-oncological operations. The main barrier to the wide application of RAS has been the increased cost that refers to both acquisition and maintenance costs. Besides, the health inequality resulting from the lack of expert robotic surgeons and the difficulty of performing robot-assisted procedures in provincial hospitals should be overcome. However, large properly designed comparative studies are required to establish the role of newly introduced RSs. In addition, urologists should keep abreast of new developments and research in robot-assisted urologic procedures.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Procedimientos Quirúrgicos Urológicos , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Procedimientos Quirúrgicos Robotizados/instrumentación , Laparoscopía/métodos , Laparoscopía/instrumentación , Procedimientos Quirúrgicos Urológicos/métodos , Procedimientos Quirúrgicos Urológicos/instrumentación , Urología/métodos , Urología/instrumentación
2.
Arab J Urol ; 22(3): 131-137, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38818253

RESUMEN

Objectives: To compare lithotripsy ablation rate with the Moses modes versus conventional pulse modes when using the Holmium:Yttrium-Aluminum-Garnet (Ho:YAG) laser. Methods: The Lumenis® Pulse P120H Holmium Laser System and a 365 µm Moses D/F/L fiber were used to assess stone ablation rate in conventional Short and Long Pulse as well as Moses Contact and Distance at 10 W (0.5Jx20Hz and 2Jx5Hz) and 60 W (1Jx60Hz and 2Jx30Hz). Hard and soft phantom stones were formed, and all tests were conducted in a custom experimental configuration installed in a saline-filled bath. The laser was delivered up to 3 kJ of total energy. The fragmentation pattern was assessed via photographs in each cohort. Results: The time to reach the target energy was 5 min and 50 s in all 10 W and 60 W trials, respectively. In both stone types, ablation was more effective when high-power, high-energy and Moses Distance was utilized. In soft stones, the lowest ablation rate was detected in the Long Pulse modality in all power, energy and frequency settings. Overall, when dusting settings (high-frequency, low-energy) were used, a deeper single cavitation was observed rather than small cavitations. Conclusions: The most effective pulse modality as evaluated via stone ablation rate depends on the stone hardness as well as energy and frequency settings. In both hard and soft stones, ablation is more effective when 60 W (2Jx30Hz) power settings and Moses Distance are used. Tailored laser settings in terms of energy and frequency could be set for each case scenario.

3.
Arab J Urol ; 22(3): 145-151, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38818258

RESUMEN

Objective: To evaluate the efficacy and safety of Holmium: Yttrium-Aluminum-Garnet (Ho:YAG) laser in bladder lithotripsy using high-power settings > 100 W. Materials and Methods: A combined experimental and clinical study was conducted. The Quanta Cyber: Ho 150 with a 550 µm Quanta optical fiber was utilized in all set-ups. Ablation rates for soft and hard artificial stones were tested in vitro using 100 W and 20 W power settings. In the experiment, a porcine bladder was used. The optical fiber was inserted through a rigid cystoscope, whilst a K-type thermocouple was inserted in the bladder dome. The tested high-power settings were 152 W, 120 W and 105 W. In every trial, the lasing time was over 60 s. In the clinical study, 35 patients underwent transurethral high-power bladder lithotripsy. Laser settings were set between 100 W and 150 W. Results: Stone mass (stone weight) was significantly lower after stone ablation independently of the stone type or the laser settings. Significantly higher mass decrease and ablation rate were detected in high-power compared to low-power settings. In the experiment, the highest temperature recorded was 32°C at 152 W. At 120 W and 105 W, the peak temperatures didn't reach 30°C. In the clinical study, a stone-free rate of 100% and a mean operative time of 43 ± 18 min were reported. All patients stayed in the hospital for one day except for one who presented minor hematuria. Additional complications did not occur. Conclusion: Ho:YAG laser lithotripsy > 100 W is an effective, fast and safe modality for the treatment of bladder calculi.

4.
Arch Ital Urol Androl ; 96(1): 12228, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38363229

RESUMEN

PURPOSE: The aim of the present, retrospective study was to describe our initial experience and early outcomes of Thulium Fiber Laser enucleation of the prostate (ThuFLEP) with the use of the FiberDust™ (Quanta System, Samarate, Italy) in patients with benign prostate hyperplasia. METHODS: From June 2022 to April 2023, all patients who underwent endoscopic enucleation of the prostate at Urology Department of the University Hospital of Patras were included. A single surgeon utilizing the same standardized operative technique performed all the surgeries. The primary endpoints included the uneventful completion of the operation, the surgical time and any minor or major complication observed intra- or post-operatively. RESULTS: Twenty patients with benign prostate hyperplasia were treated with ThuFLEP. All the surgeries were completed successfully and uneventfully. The enucleation phase of the operation was completed in a mean time of 45±9.1 min, while the average time needed for the morcellation was 17.65±3.42 min. No significant complications were observed intra- or post-operatively. The average hemoglobin drop was calculated to be 0.94±0.71 g/dL. CONCLUSIONS: All the operations were successfully and efficiently completed with the use of the FiberDust™ (Quanta System, Samarate, Italy) in ThuFLEP. Significant blood loss or major complications were not observed.


Asunto(s)
Terapia por Láser , Láseres de Estado Sólido , Hiperplasia Prostática , Resección Transuretral de la Próstata , Masculino , Humanos , Próstata/cirugía , Estudios Retrospectivos , Tulio , Hiperplasia , Resultado del Tratamiento , Láseres de Estado Sólido/uso terapéutico , Hiperplasia Prostática/cirugía , Resección Transuretral de la Próstata/métodos
5.
Int Urol Nephrol ; 56(5): 1577-1583, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38175386

RESUMEN

PURPOSE: To investigate the learning curve in four basic surgical skills in laparoscopic and robotic surgeries, and evaluate the approximate time needed to reach sufficient expertise in performing these tasks with the avatera® system. METHODS: Twenty urology residents with no previous experience in dry-lab and robotic surgery were asked to complete four basic laparoscopic tasks (peg transfer, circle cutting, needle guidance, and suturing) laparoscopically and robotically. All participants were asked to complete the tasks first after watching the Uroweb educational material and, second, after undertaking a 2-hour training in robotic and laparoscopic dry-lab. Thereafter, all trainees continued to undertake 2-hour training programs until being able to complete the tasks with the avatera® robot at the desired time. Paired t test and one-way ANOVA test were used to analyze time differences between the groups. RESULTS: Time needed to complete all tasks either robotically or laparoscopically was significantly less in the second compared to the first attempt for all Groups in each Task. In the robotic dry-lab, time needed to complete the tasks was significantly less than in the laparoscopic dry-lab. A significant effect of previous laparoscopic experience of the participants on the training time needed to achieve most of the goal times was detected. CONCLUSION: The results of the study highlight the role of previous laparoscopic experience in the training time needed to achieve the performance time goals and demonstrate that the learning curve of basic surgical skills using the avatera® system is steeper than the laparoscopic one.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Competencia Clínica , Robótica/educación , Laparoscopía/métodos , Curva de Aprendizaje
6.
Asian J Androl ; 26(3): 250-259, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38265253

RESUMEN

Peyronie's disease (PD) is characterized by abnormal penile curvature, and various surgical methods have been developed using different graft materials. However, there is currently no universal agreement on which type of graft is the best. The objective of this review was to evaluate the available literature and identify the most effective graft material for penile curvature correction in PD. A literature search was conducted using electronic databases, including PubMed, Scopus, and the Cochrane Library. The patients, intervention, comparison, and outcome (PICO) approach was used to define the eligibility of studies. Two authors independently selected studies, evaluated them, and extracted data. Random-effect models using the DerSimonian-Laird method were used. Most studies were single-arm studies and had a high risk of bias. Buccal mucosa grafts (BMG) were found to result in the highest penile straightening rates and were associated with the least de novo erectile dysfunction. TachoSil grafts demonstrated a high success rate in straightening despite a higher mean preoperative curvature, while Tutoplast grafts had a higher incidence of postoperative erectile dysfunction. BMG had the highest percentage of postoperative penile straightening. Overall, the TachoSil graft showed the best performance when preoperative curvature is taken into account. Based on the available literature, BMG appear to be the most effective for penile curvature correction in PD, but this is offset by the requirement for low preoperative curvature. The TachoSil graft shows the best overall performance when preoperative curvature is considered. Comparative randomized clinical trials are still needed to determine graft superiority.


Asunto(s)
Mucosa Bucal , Induración Peniana , Humanos , Induración Peniana/cirugía , Masculino , Mucosa Bucal/trasplante , Pene/cirugía , Pene/anomalías , Disfunción Eréctil/cirugía , Resultado del Tratamiento
7.
Urology ; 183: 106-110, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37981058

RESUMEN

OBJECTIVE: To evaluate retrospectively the feasibility of Florence robotic intracorporeal neobladder technique in laparoscopic radical cystectomy. METHODS: Fourteen patients with muscle-invasive bladder cancer underwent laparoscopic radical cystectomy and Florence robotic intracorporeal neobladder between September 2021 and February 2023. Patients' characteristics, pathology data, perioperative outcomes, postoperative complications, and follow-up data were collected. RESULTS: All operations were successfully completed laparoscopically. The median total operative time was 343 minutes, and the median estimated blood loss was 169.5 mL. No intraoperative complications were observed. The median hospitalization time was 7days, while the median time to regular diet was 3days. Clavien Dindo Grade < III complications appeared in five patients within 30days postoperation. No other complications were noted over the 90days follow-up. Organ-confined disease was confirmed in 11 patients and locally advanced disease in three patients. At 3months follow-up, eight and four patients were daytime and night-time continent, respectively. CONCLUSION: Replicating Florence robotic intracorporeal neobladder in laparoscopic radical cystectomy is safe, feasible, and repeatable, based on the encouraging perioperative, oncological, and functional outcomes of our study. However, further prospective studies on a larger scale are required to prove its long-term results.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Neoplasias de la Vejiga Urinaria , Derivación Urinaria , Humanos , Cistectomía/métodos , Estudios Retrospectivos , Estudios Prospectivos , Resultado del Tratamiento , Neoplasias de la Vejiga Urinaria/patología , Laparoscopía/métodos , Derivación Urinaria/métodos , Procedimientos Quirúrgicos Robotizados/métodos
8.
Minerva Urol Nephrol ; 76(1): 52-59, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38015550

RESUMEN

BACKGROUND: Robot-assisted radical prostatectomy is a minimally invasive, safe procedure preferred in the management of localized prostate cancer. In this study, we present our initial experience with the avatera™ system (avateramedical GmbH, Jena, Germany) in robot-assisted radical prostatectomy. METHODS: A total of fourteen patients underwent robot-assisted radical prostatectomy using this newly introduced system in our department from June 2022 to October 2022. The primary endpoints of the study were the time and the successful completion of the operation, the hemoglobin drop and the presence of complications. The pathologic tumor stage and the presence of positive surgical margins were also recorded. Follow-up of the patients for the functional outcomes over a period of 3 months took place. RESULTS: The completion of all the surgeries was successful. The median draping and docking times were 9.5 minutes (7-13) and 10 minutes (5-40), respectively. The median console time was 103.5 minutes (90-121). No conversion to laparoscopic or open prostatectomy was necessary. The median hemoglobin drop was 1.95 g/dL (0.3-2.7), while positive surgical margins were present in two patients postoperatively. No major complications or need for transfusion were noticed. Six months after the procedure, 78.6% of the participants were continent while 77.7% of the nerve-sparing patients reported erections adequate for intercourse. CONCLUSIONS: All the operations were completed successfully without major complications or significant blood loss. The functional outcomes were acceptable according to the literature. Based on the early outcomes, robot-assisted radical prostatectomy with the avatera™ system (avateramedical GmbH) could be considered feasible, safe, and efficient.


Asunto(s)
Laparoscopía , Robótica , Masculino , Humanos , Proyectos Piloto , Márgenes de Escisión , Estudios Prospectivos , Prostatectomía , Hemoglobinas
9.
Cent European J Urol ; 76(3): 233-238, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38045785

RESUMEN

Introduction: The aim of this study was to evaluate outflow variation in different locations of the pyelocaliceal system with the use of different ureteral access sheath (UAS) sizes and different UAS positioning. Material and methods: The experimental setup included an anaesthetised porcine model, a 7.5-Fr ureteroscope with a 200-µm laser fibre inserted in the working channel, a hand-held pumping irrigating system, and UAS of different sizes, namely: 9.5/11.5 Fr, 12/14 Fr, and 14/16 Fr. Each UAS was placed just below the ureteropelvic junction (UPJ) or in the mid-ureter. The ureteroscope was placed in the renal pelvis, upper and lower calyces, and outflow measurements were obtained with 3-second interval pumping for one minute in every experimental setup. Results: The UAS positioning in the mid-ureter was associated with significantly higher outflow rates in the lower calyx (p = 0.041). While the UAS was below the UPJ, we observed a trend of lower outflow rate in the lower calyx, which was completely inverted when the UAS was in the mid-ureter. Increasing the UAS size from 9.5/11.5 Fr to 12/14 Fr led to a significant increase in outflow in the renal pelvis and upper calyx (p = 0.007), but not in the lower calyx. A further increase to 14/16 Fr did not produce increased flow. Conclusions: Different locations of the pyelocaliceal system have different fluid mechanics during fURS. In the renal pelvis and upper calyx increasing the diameter of the UAS improved the outflow, whereas in the lower calyx the position of the UAS seems to be the most relevant factor. These variables should be considered when performing fURS, especially with high-power laser lithotripsy.

10.
Arch Ital Urol Androl ; 95(4): 11852, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38058288

RESUMEN

PURPOSE: To evaluate the safety and feasibility of partial nephrectomy with the use of the novel robotic system in an in vivo animal model. METHODS: Right partial nephrectomy was performed in female pigs by a surgical team consisting of one surgeon and one bedside assistant. Both were experienced in laparoscopic surgery and trained in the use of the novel robotic system. The partial nephrectomies were performed using four trocars (three trocars for the robotic arms and one as an assistant trocar). The completion of the operations, set-up time, operation time, warm ischemia time (WIT) and complication events were recorded. The decrease in all variables between the first and last operation was calculated. RESULTS: In total, eight partial nephrectomies were performed in eight female pigs. All operations were successfully completed. The median set-up time was 19.5 (range, 15-30) minutes, while the estimated median operative time was 80.5 minutes (range, 59-114). The median WIT was 23.5 minutes (range, 17-32) and intra- or postoperative complications were not observed. All variables decreased in consecutive operations. More precisely, the decrease in the set-up time was calculated to 15 minutes between the first and third attempts. The operative time was reduced by 55 minutes between the first and last operation, while the WIT was decreased by 15 minutes during the consecutive attempts. No complications were noticed in any operation. CONCLUSIONS: Using the newly introduced robotic system, all the advantages of robotic surgery are optimized and incorporated, and partial nephrectomies can be performed in a safe and effective manner.


Asunto(s)
Neoplasias Renales , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Femenino , Animales , Porcinos , Neoplasias Renales/cirugía , Estudios de Factibilidad , Nefrectomía , Resultado del Tratamiento , Estudios Retrospectivos
11.
Urol Res Pract ; 49(6): 387-391, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37971390

RESUMEN

OBJECTIVE: To evaluate the tissue injury caused by the force applied by the roboticassisted graspers of avatera robotic surgical system on bowel tissue. METHODS: An experimental in vivo porcine model with 1 pig was conducted. After a standard transperitoneal setup of the avatera robotic surgical system, different laparoscopic and robotic graspers were used on the bowel with maximum force applied each time. Robotic atraumatic grasper, laparoscopic right angle grasper, laparoscopic curved grasper, and laparoscopic atraumatic grasper were used. After using all graspers, the pig was sacrificed. The bowel segments were resected and sent for histological analysis. RESULTS: The pathologist reported that all the graspers caused signs of acute inflammation without any irreversible damage or signs compatible with ischemia of the tissue. No significant difference in histology was observed between the graspers. CONCLUSION: No permanent damage was caused by graspers, except for acute, reversible inflammation. Concluding, the avatera grasper could be safe to use on bowel segments, independent of the applied pressure.

12.
World J Urol ; 41(11): 3155-3160, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37668715

RESUMEN

PURPOSE: This pilot study was designed to interpret the technically specific features of the avatera robotic system and present our initial experience with this novel platform in robot-assisted pyeloplasty (RAP). METHODS: A single-center prospective study was conducted including all patients who underwent RAP with the avatera robotic system from June 2022 to October 2022 in our Department. Transperitoneal robot-assisted dismembered pyeloplasty was performed in all cases. The trocar placement and the surgical technique were similar in all patients. The successful completion of the procedures, operation time (including draping, docking and console time), decrease in hemoglobin postoperatively, and presence of any complications were the study's primary endpoints. RESULTS: In total, nine patients underwent RAP using the avatera system. All procedures were successfully completed. The draping of the robotic unit was completed in a median time of 10 min (range 7-15), while the median docking time was 17 min (range 10-24). The median console time was 88 min (range 78-116) and no complications were noticed. The median hemoglobin drop was calculated to 0.7 g/dL (range 0.4-1). During the mean follow-up of 9.33 ± 2.78 months, no late postoperative complications were noticed. CONCLUSION: The early outcomes of the use of the novel avatera system in RAP are presented. All operations were successfully completed with safety and efficacy, without complications or significant blood loss.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Obstrucción Ureteral , Humanos , Robótica/métodos , Estudios Prospectivos , Proyectos Piloto , Resultado del Tratamiento , Obstrucción Ureteral/cirugía , Procedimientos Quirúrgicos Urológicos/métodos , Hemoglobinas , Laparoscopía/métodos , Pelvis Renal/cirugía , Procedimientos Quirúrgicos Robotizados/métodos
13.
J Endourol ; 37(3): 273-278, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36274228

RESUMEN

Purpose: To evaluate the feasibility and intraoperative technical parameters of the new robot-assisted surgical system Avatera by performing bilateral nephrectomy in a live porcine model. Materials and Methods: Six pigs underwent bilateral robot-assisted radical nephrectomy using the Avatera robotic system (RS). The operations were performed by experienced open (Group 1) and laparoscopic (Group 2) surgeons. The operating time, docking time, set-up time, and console time were evaluated. Data regarding intraoperative complications (major or not), injury of adjacent organs, and technical difficulties during the operation were also recorded. Results: Robot-assisted bilateral nephrectomy was completed effectively in all sample pigs. The docking time and set-up time were similar among the two groups, whereas the console time and operating time were significantly longer for the open surgeon group. Two intraoperative minor complications occurred in the open surgeon's group. An inadvertent damage of the renal vein occurred in two cases and the bleeding was controlled effectively. Other than the initial two cases, the estimated blood loss was <50 mL in both groups. Injury of the adjacent organs was not noticed. Conclusions: The study demonstrated that radical nephrectomy using the Avatera robotic surgical system is technically feasible, safe, and valid in pigs. Our results warrant the application of the Avatera RS in other urologic procedures, collecting data for further clinical trials.


Asunto(s)
Laparoscopía , Procedimientos Quirúrgicos Robotizados , Robótica , Urología , Porcinos , Animales , Estudios de Factibilidad , Nefrectomía/métodos
14.
World J Urol ; 41(2): 477-482, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36577927

RESUMEN

PURPOSE: To investigate the feasibility of the avatera system for performing robot-assisted radical cystectomy (RARC) followed by intracorporeal reconstruction of ileal neobladder. METHODS: Six anesthetized female pigs were used to perform RARC and formation of the intracorporeal orthotopic ileal neobladder. Three surgeons with different level of expertise in the use of robotic systems performed RARC after a short instructional lecture and a 2-h hands-on training. The urinary diversion phase was performed only by the experienced surgeon. The successful completion of the procedure, operative time for demolitive and reconstructive phases, intraoperative blood loss and malfunction of the robotic system were evaluated. RESULTS: An improvement of the operative time was observed for each surgeon. The experienced surgeon, the fellow and the resident improved their time by 11, 15, and 22 min, respectively, between the first and the second RARC performed. The most significant time difference was demonstrated by the resident, who had no previous experience in using robotic systems. The time difference between the first and the last orthotopic ileal neobladder creation for the experienced surgeon was 51 min. CONCLUSION: The feasibility of avatera system for performing complex surgical procedure such as RARC with intracorporeal neobladder formation was demonstrated by this experimental study. No major bleeding or severe malfunctions were observed during the procedures. Significant improvement in operative time was demonstrated with the increasing experience from 1st to 6th case.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Neoplasias de la Vejiga Urinaria , Derivación Urinaria , Femenino , Animales , Porcinos , Cistectomía/métodos , Neoplasias de la Vejiga Urinaria/cirugía , Estudios de Factibilidad , Resultado del Tratamiento , Derivación Urinaria/métodos , Procedimientos Quirúrgicos Robotizados/métodos
15.
Cent European J Urol ; 76(4): 336-346, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38230311

RESUMEN

Introduction: Recurrent miscarriage is defined as 2 or more failed clinical pregnancies, typically known as repeated pregnancy loss, occurring before 20 gestational weeks, and further categorized into primary and secondary types. It represents a common and distressing condition to deal with in the field of reproductive medicine, usually affecting <5% of couples, with up to 50% of cases lacking a clearly defined aetiology. The epidemiology also varies depending on maternal age. Remarkably, the situation significantly afflicts expecting parents, whereas maternal factors, such as age and previous pregnancy loss rate, are commonly reported as risk factors. Although previously underestimated, existing evidence suggests the male factor is a possible cause of recurrent pregnancy loss. Material and methods: A non-systematic literature review was conducted in the PubMed and Scopus databases for articles written in English investigating the possible association of the male factor in recurrent pregnancy loss. The eligible studies were synthesized in a narrative review format upon discussion and consensus among the authors after being previously independently assessed and selected. Results: Lifestyle, obesity, genetic predisposition, chromosomal anomalies, endocrine dysfunction, anatomical abnormalities, immunological factors, infections, and oxidative stress can result in poor embryo development and recurrent miscarriage. Although professional organizations currently recognize male gender as a possible risk factor, specific recommendations on the diagnostic and therapeutic field are still lacking, and the condition necessitates a high level of suspicion and case-by-case management. Conclusions: In this review, we delve deeper into the contribution of the male factor in the concept of recurrent miscarriage.

16.
Arab J Urol ; 19(3): 264-273, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34552778

RESUMEN

OBJECTIVE: To investigate the usage and the efficacy of vitamins as primary or adjuvant treatment in infertile men with varicocele. METHODS: A systematic search in PubMed, the Medical Literature Analysis and Retrieval System Online (MEDLINE) and Cochrane Library with the terms (varicocele) AND (vitamins) was performed. We searched for studies: a) reporting the administration of vitamins (individually or as part of a complex) in men with varicocele and infertility, b) primarily or adjuvant to invasive treatment, and c) reporting the impact on semen parameters and/or pregnancy rates. Exclusion criteria were animal, adolescent and non-English studies, grey literature and trials reporting abstracts only. RESULTS: Seven studies were identified eligible for qualitative analysis. All studies were randomised except one (case series). Vitamins were administered dominantly as part of antioxidant complex and only two studies used vitamins (C and E, respectively) as sole agent. In two studies, vitamin monotherapy resulted in improvement in semen quality, but the effect on pregnancy rates is unknown. One study reported no efficacy of adjuvant multivitamin treatment after embolisation in terms of both semen quality and pregnancy rates. Finally, four studies reported a positive effect of vitamins on semen parameters after varicocelectomy, but the effect on pregnancy rates is conflicting; one study reported improved pregnancy rates with adjuvant treatment, two studies did not evaluate the pregnancy rates, and in one study the outcome was unclear due to missing data. CONCLUSIONS: Vitamins have been used mostly as part of an antioxidant panel for the management of infertile men with varicocele. Most studies have found a positive impact on semen parameters in selected men with varicocele and infertility, as primary or adjuvant treatment. However, the clinical benefit of vitamins administration on pregnancy rate is under-evaluated and should be the target of future research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA