Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Med Phys ; 46(11): 5152-5158, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31419317

RESUMEN

PURPOSE: Dose deposition measurements for parallel MRI-linacs have previously only shown comparisons between 0 T and a single available magnetic field. The Australian MRI-Linac consists of a magnet coupled with a dual energy linear accelerator and a 120 leaf Multi-Leaf Collimator with the radiation beam parallel to the magnetic field. Two different magnets, with field strengths of 1 and 1.5 T, were used during prototyping. This work aims to characterize the impact of the magnetic field at 1 and 1.5 T on dose deposition, possible by comparing dosimetry measured at both magnetic field strengths to measurements without the magnetic field. METHODS: Dose deposition measurements focused on a comparison of beam quality (TPR20/10 ), PDD, profiles at various depths, surface doses, and field size output factors. Measurements were acquired at 0, 1, and 1.5 T. Beam quality was measured using an ion chamber in solid water at isocenter with appropriate TPR20/10 buildup. PDDs and profiles were acquired via EBT3 film placed in solid water either parallel or perpendicular to the radiation beam. Films at surface were used to determine surface dose. Output factors were measured in solid water using an ion chamber at isocenter with 10 cm solid water buildup. RESULTS: Beam quality was within ±0.5% of the 0 T value for the 1 and 1.5 T magnetic field strengths. PDDs and profiles showed agreement for the three magnetic field strengths at depths beyond 20 mm. Deposited dose increased at shallower depths due to electron focusing. Output factors showed agreement within 1%. CONCLUSION: Dose deposition at depth for a parallel MRI-linac was not significantly impacted by either a 1 or 1.5 T magnetic field. PDDs and profiles at shallow depths and surface dose measurements showed significant differences between 0, 1, and 1.5 T due to electron focusing.


Asunto(s)
Campos Magnéticos , Imagen por Resonancia Magnética/instrumentación , Aceleradores de Partículas
3.
Med Phys ; 45(1): 479-487, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29156098

RESUMEN

PURPOSE: Longitudinal magnetic fields narrow beam penumbra and tighten lateral spread of secondary electrons in air cavities, including lung tissue. Gafchromic® EBT3 film was used to investigate differences between penumbra in solid water and solid lung, without a magnetic field (0 T) and with two field strengths (0.9 and 1.5 T). METHODS: The first prototype of the Australian MRI-linac consisted of a 1.5 T Siemens Sonata MRI and Varian industrial linatron (nominal 4 MV). The second prototype replaced the Sonata with a 1.0 T Agilent split-bore magnet. Measurements were completed at 0.9 T to maintain the same source-to-surface distance between set-ups. Gammex-rmi® solid water with 50 mm of CIRS solid lung inserted as a lung cavity was positioned inside each magnet. This was compared to the same set-up with solid water only, where film measurements were completed at solid water equivalent depths corresponding to entrance interface/mid/exit interface positions of solid lung from the first set-up. Multileaf collimator (MLC)-defined field sizes were set to 3 × 3 cm2 and 10 × 10 cm2 . The 80%-20% penumbral width was determined. RESULTS: Under 1.5 T conditions, penumbra narrowing occurred up to 4.4 ± 0.1 mm compared to 0 T. As expected, the effect was less for 0.9 T, which resulted in a maximum narrowing of 2.5 ± 0.1 mm. Exit profile penumbra were more affected than entrance penumbra by up to 2.6 ± 0.2 mm. The 1.5 T field brought the solid water and lung penumbral widths more into alignment by a maximum difference of 0.4 ± 0.1 mm. CONCLUSIONS: The trimming of penumbral widths due to magnetic fields in solid water and lung was demonstrated and compared to 0 T. The 0.9 and 1.5 T field trimmed the penumbra by up to 2.5 ± 0.1 mm and 4.4 ± 0.1 mm respectively.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Imagen por Resonancia Magnética/instrumentación , Aceleradores de Partículas/instrumentación , Electrones , Dosimetría por Película , Humanos , Pulmón/diagnóstico por imagen , Pulmón/efectos de la radiación , Neoplasias Pulmonares/diagnóstico por imagen , Campos Magnéticos , Fantasmas de Imagen , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...