Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Am J Ophthalmol ; 158(5): 916-23, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25068639

RESUMEN

PURPOSE: To determine the intra- and inter-visit reproducibility of ganglion cell-inner plexiform layer thickness measures using handheld optical coherence tomography (OCT) in sedated children with optic pathway gliomas and/or neurofibromatosis type 1 (NF1). DESIGN: Prospective longitudinal cohort study. METHODS: Children with sporadic optic pathway gliomas and/or NF1 who had ≥2 volumes acquired over the macula using handheld OCT during sedation for clinically indicated magnetic resonance imaging were eligible for the intra-visit cohort. Children with repeat handheld OCT imaging within 6 months were eligible for the inter-visit cohort. Total retinal thickness and ganglion cell-inner plexiform layer thickness were measured using custom-designed automated segmentation software. Reproducibility was compared across average and anatomic quadrant by calculating the coefficient of variation (CV) and intraclass correlation coefficient (ICC). RESULTS: Forty-two subjects (median age 5.4 years, range 0.8-12.7 years) contributed 45 eyes to the intra-visit cohort. Thirty-one subject eyes had normal vision and 14 had abnormal vision (decreased visual acuity and/or visual field). Average and quadrant ganglion cell-inner plexiform layer measures demonstrated CVs ≤4.5% with excellent ICCs (>0.935). The superior quadrant CV differed between subjects with (4.4%) and without (2.1%) vision loss (P < .05). Twenty-five subject eyes were eligible for the inter-visit cohort, demonstrating CVs from 1.6% to 5.2%. Inter-visit ICCs were excellent (0.955-0.995). DISCUSSION: Handheld OCT imaging in sedated children with optic pathway gliomas produces highly reproducible measures of ganglion cell-inner plexiform layer thickness.


Asunto(s)
Fibras Nerviosas/patología , Glioma del Nervio Óptico/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Mácula Lútea/patología , Imagen por Resonancia Magnética , Masculino , Glioma del Nervio Óptico/fisiopatología , Estudios Prospectivos , Curva ROC , Reproducibilidad de los Resultados , Campos Visuales/fisiología
2.
Am J Ophthalmol ; 158(4): 780-787.e1, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24983792

RESUMEN

PURPOSE: To determine the intra- and intervisit reproducibility of circumpapillary retinal nerve fiber layer (RNFL) measures using handheld optical coherence tomography (OCT) in sedated children. DESIGN: Prospective cross-sectional and longitudinal study. METHODS: Children undergoing sedation for a clinically indicated magnetic resonance imaging for an optic pathway glioma and/or neurofibromatosis type 1 (NF1) had multiple 6 × 6 mm volumes (isotropic 300 × 300 or nonisotropic 1000 × 100 samplings) acquired over the optic nerve. Children with 2 handheld OCT sessions within 6 months were included in the intervisit cohort. The intra- and intervisit coefficient of variation (CV) and intraclass correlation coefficient (ICC) were calculated for the average and anatomic quadrant circumpapillary RNFL thickness. RESULTS: Fifty-nine subjects (mean age 5.1 years, range 0.8-13.0 years) comprised the intravisit cohort and 29 subjects (mean age 5.7 years, range 1.8-12.7 years) contributed to the intervisit cohort. Forty-nine subjects had an optic pathway glioma and 10 subjects had NF1 without an optic pathway glioma. The CV was comparable regardless of imaging with an isotropic and nonisotropic volume in both the intra- and intervisit cohorts. The average circumpapillary RNFL demonstrated the lowest CV and highest ICC compared to the quadrants. For the intervisit cohort, the average ICC was typically higher while the CV was typically lower, but not statistically different compared to the other quadrants. DISCUSSION: Circumpapillary RNFL measures acquired with handheld OCT during sedation demonstrate good intra- and intervisit reproducibility. Handheld OCT has the potential to monitor progressive optic neuropathies in young children who have difficulty cooperating with traditional OCT devices.


Asunto(s)
Sedación Consciente , Fibras Nerviosas/patología , Neurofibromatosis 1/diagnóstico , Disco Óptico/patología , Glioma del Nervio Óptico/diagnóstico , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/instrumentación , Adolescente , Niño , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Estudios Longitudinales , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
3.
Invest Ophthalmol Vis Sci ; 55(3): 1402-8, 2014 Mar 10.
Artículo en Inglés | MEDLINE | ID: mdl-24519429

RESUMEN

PURPOSE: To determine if measures of macular ganglion cell layer-inner plexiform layer (GCL-IPL) thickness can discriminate between children with and without vision loss (visual acuity or field) from their optic pathway glioma (OPG) using spectral-domain optical coherence tomography (SD-OCT). METHODS: Children with OPGs (sporadic or secondary to neurofibromatosis type 1) enrolled in a prospective study of SD-OCT were included if they were cooperative for vision testing and macular SD-OCT images were acquired. Manual segmentation of the macular GCL-IPL and macular retinal nerve fiber layer (RNFL) was performed using elliptical annuli with diameters of 1.5, 3.0, and 4.5 mm. Logistic regression assessed the ability of GCL-IPL and RNFL thickness measures (micrometers) to differentiate between the normal and abnormal vision groups. RESULTS: Forty-seven study eyes (normal vision = 31, abnormal vision = 16) from 26 children with OPGs were included. Median age was 5.3 years (range, 2.5-12.8). Thickness of all GCL-IPL and RNFL quadrants differed between the normal and abnormal vision groups (P < 0.01). All GCL-IPL measures demonstrated excellent discrimination between groups (area under the curve [AUC] > 0.90 for all diameters). Using the lower fifth percentile threshold, the number of abnormal GCL-IPL inner macula (3.0 mm) quadrants achieved the highest AUC (0.989) and was greater than the macula RNFL AUCs (P < 0.05). CONCLUSIONS: Decreased GCL-IPL thickness (

Asunto(s)
Fibras Nerviosas/patología , Glioma del Nervio Óptico/patología , Células Ganglionares de la Retina/patología , Baja Visión/etiología , Agudeza Visual , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Masculino , Glioma del Nervio Óptico/complicaciones , Glioma del Nervio Óptico/fisiopatología , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Baja Visión/patología , Baja Visión/fisiopatología , Campos Visuales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...