Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
J Imaging ; 9(9)2023 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-37754931

RESUMEN

Colorectal cancer is one of the leading death causes worldwide, but, fortunately, early detection highly increases survival rates, with the adenoma detection rate being one surrogate marker for colonoscopy quality. Artificial intelligence and deep learning methods have been applied with great success to improve polyp detection and localization and, therefore, the adenoma detection rate. In this regard, a comparison with clinical experts is required to prove the added value of the systems. Nevertheless, there is no standardized comparison in a laboratory setting before their clinical validation. The ClinExpPICCOLO comprises 65 unedited endoscopic images that represent the clinical setting. They include white light imaging and narrow band imaging, with one third of the images containing a lesion but, differently to another public datasets, the lesion does not appear well-centered in the image. Together with the dataset, an expert clinical performance baseline has been established with the performance of 146 gastroenterologists, who were required to locate the lesions in the selected images. Results shows statistically significant differences between experience groups. Expert gastroenterologists' accuracy was 77.74, while sensitivity and specificity were 86.47 and 74.33, respectively. These values can be established as minimum values for a DL method before performing a clinical trial in the hospital setting.

2.
Ann Surg ; 275(3): 440-447, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34647708

RESUMEN

OBJECTIVE: The aim of this study was to examine the clinical efficacy and safety of the duodenal-jejunal bypass liner (DJBL) while in situ for 12 months and for 12 months after explantation. SUMMARY BACKGROUND DATA: This is the largest randomized controlled trial (RCT) of the DJBL, a medical device used for the treatment of people with type 2 diabetes mellitus (T2DM) and obesity. Endoscopic interventions have been developed as potential alternatives to those not eligible or fearful of the risks of metabolic surgery. METHODS: In this multicenter open-label RCT, 170 adults with inadequately controlled T2DM and obesity were randomized to intensive medical care with or without the DJBL. Primary outcome was the percentage of participants achieving a glycated hemoglobin reduction of ≥20% at 12 months. Secondary outcomes included weight loss and cardiometabolic risk factors at 12 and 24 months. RESULTS: There were no significant differences in the percentage of patients achieving the primary outcome between both groups at 12 months [DJBL 54.6% (n = 30) vs control 55.2% (n = 32); odds ratio (OR) 0.93, 95% confidence interval (CI): 0.44-2.0; P = 0.85]. Twenty-four percent (n = 16) patients achieved ≥15% weight loss in the DJBL group compared to 4% (n = 2) in the controls at 12 months (OR 8.3, 95% CI: 1.8-39; P = .007). The DJBL group experienced superior reductions in systolic blood pressure, serum cholesterol, and alanine transaminase at 12 months. There were more adverse events in the DJBL group. CONCLUSIONS: The addition of the DJBL to intensive medical care was associated with superior weight loss, improvements in cardiometabolic risk factors, and fatty liver disease markers, but not glycemia, only while the device was in situ. The benefits of the devices need to be balanced against the higher rate of adverse events when making clinical decisions. TRIAL REGISTRATION: ISRCTN30845205. isrctn.org; Efficacy and Mechanism Evaluation Programme, a Medical Research Council and National Institute for Health Research (NIHR) partnership reference 12/10/04.


Asunto(s)
Diabetes Mellitus Tipo 2/cirugía , Duodeno/cirugía , Derivación Yeyunoileal , Yeyuno/cirugía , Obesidad/cirugía , Adulto , Femenino , Humanos , Derivación Yeyunoileal/efectos adversos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
3.
Artículo en Inglés | MEDLINE | ID: mdl-34353822

RESUMEN

OBJECTIVES: Helicobacter pylori infection is a common cause of chronic gastritis worldwide and an established risk factor for developing gastric malignancy. The endoscopic appearances predicting H. pylori status are an ongoing area of research, as are their diagnostic accuracies. This study aimed to establish the diagnostic accuracy of several mucosal features predictive of H. pylori negative status and formulate a simple prediction model for use at the time of endoscopy. DESIGN: Patients undergoing high-definition upper gastrointestinal (GI) endoscopy without magnification were recruited prospectively. During the endoscopy, the presence or absence of specific endoscopic findings was noted. Sydney protocol biopsies were used as the diagnostic reference standard, and urease test if taken. The results informed a logistic regression model used to produce a simple diagnostic approach. This model was subsequently validated using a further cohort of 30 patients. RESULTS: 153 patients were recruited and completed the study protocol. The prevalence of active H. pylori infection was 18.3% (28/153). The overall diagnostic accuracy of the simple prediction model was 80.0%, and 100% of patients with active H. pylori infection were correctly classified. The presence of regular arrangement of collecting venules (RAC) showed a positive predictive value for H. pylori naïve status of 90.7%, rising to 93.6% for patients under the age of 60. CONCLUSION: A simple endoscopic model may be accurate for predicting H. pylori status of a patient, and the need for biopsy-based tests. The presence of RAC in the stomach is an accurate predictor of H. pylori negative status, particularly in patients under the age of 60. TRIAL REGISTRATION NUMBER: The study was registered with ClinicalTrials.gov, No. NCT02385045.


Asunto(s)
Infecciones por Helicobacter , Helicobacter pylori , Mucosa Gástrica , Gastroscopía , Infecciones por Helicobacter/diagnóstico , Humanos , Estudios Prospectivos
4.
J Med Internet Res ; 23(7): e27370, 2021 07 14.
Artículo en Inglés | MEDLINE | ID: mdl-34259645

RESUMEN

BACKGROUND: Colonoscopy reduces the incidence of colorectal cancer (CRC) by allowing detection and resection of neoplastic polyps. Evidence shows that many small polyps are missed on a single colonoscopy. There has been a successful adoption of artificial intelligence (AI) technologies to tackle the issues around missed polyps and as tools to increase the adenoma detection rate (ADR). OBJECTIVE: The aim of this review was to examine the diagnostic accuracy of AI-based technologies in assessing colorectal polyps. METHODS: A comprehensive literature search was undertaken using the databases of Embase, MEDLINE, and the Cochrane Library. PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines were followed. Studies reporting the use of computer-aided diagnosis for polyp detection or characterization during colonoscopy were included. Independent proportions and their differences were calculated and pooled through DerSimonian and Laird random-effects modeling. RESULTS: A total of 48 studies were included. The meta-analysis showed a significant increase in pooled polyp detection rate in patients with the use of AI for polyp detection during colonoscopy compared with patients who had standard colonoscopy (odds ratio [OR] 1.75, 95% CI 1.56-1.96; P<.001). When comparing patients undergoing colonoscopy with the use of AI to those without, there was also a significant increase in ADR (OR 1.53, 95% CI 1.32-1.77; P<.001). CONCLUSIONS: With the aid of machine learning, there is potential to improve ADR and, consequently, reduce the incidence of CRC. The current generation of AI-based systems demonstrate impressive accuracy for the detection and characterization of colorectal polyps. However, this is an evolving field and before its adoption into a clinical setting, AI systems must prove worthy to patients and clinicians. TRIAL REGISTRATION: PROSPERO International Prospective Register of Systematic Reviews CRD42020169786; https://www.crd.york.ac.uk/prospero/display_record.php?ID=CRD42020169786.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Inteligencia Artificial , Pólipos del Colon/diagnóstico , Colonoscopía , Neoplasias Colorrectales/diagnóstico , Computadores , Humanos
5.
Surg Endosc ; 35(8): 4890-4899, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34028606

RESUMEN

BACKGROUND: Interventional endoluminal therapy is rapidly advancing as a minimally invasive surgical technique. The expanding remit of endoscopic therapy necessitates precision control. Eye tracking is an emerging technology which allows intuitive control of devices. This was a feasibility study to establish if a novel eye gaze-controlled endoscopic system could be used to intuitively control an endoscope. METHODS: An eye gaze-control system consisting of eye tracking glasses, specialist cameras and a joystick was used to control a robotically driven endoscope allowing steering, advancement, withdrawal and retroflexion. Eight experienced and eight non-endoscopists used both the eye gaze system and a conventional endoscope to identify ten targets in two simulated environments: a sphere and an upper gastrointestinal (UGI) model. Completion of tasks was timed. Subjective feedback was collected from each participant on task load (NASA Task Load Index) and acceptance of technology (Van der Laan scale). RESULTS: When using gaze-control endoscopy, non-endoscopists were significantly quicker when using gaze-control rather than conventional endoscopy (sphere task 3:54 ± 1:17 vs. 9:05 ± 5:40 min, p = 0.012, and UGI model task 1:59 ± 0:24 vs 3:45 ± 0:53 min, p < .001). Non-endoscopists reported significantly higher NASA-TLX workload total scores using conventional endoscopy versus gaze-control (80.6 ± 11.3 vs 22.5 ± 13.8, p < .001). Endoscopists reported significantly higher total NASA-TLX workload scores using gaze control versus conventional endoscopy (54.2 ± 16 vs 26.9 ± 15.3, p = 0.012). All subjects reported that the gaze-control had positive 'usefulness' and 'satisfaction' score of 0.56 ± 0.83 and 1.43 ± 0.51 respectively. CONCLUSIONS: The novel eye gaze-control system was significantly quicker to use and subjectively lower in workload when used by non-endoscopists. Further work is needed to see if this would translate into a shallower learning curve to proficiency versus conventional endoscopy. The eye gaze-control system appears feasible as an intuitive endoscope control system. Hybrid gaze and hand control may prove a beneficial technology to evolving endoscopic platforms.


Asunto(s)
Endoscopios , Carga de Trabajo , Endoscopía , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos
6.
Heart Rhythm ; 18(5): 723-731, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33378703

RESUMEN

BACKGROUND: The conduction delay and block that compose the critical isthmus of macroreentrant ventricular tachycardia (VT) is partly "functional" in that they only occur at faster cycle lengths. Close-coupled pacing stresses the myocardium's conduction capacity and may reveal late potentials (LPs) and fractionation. Interest has emerged in targeting this functional substrate. OBJECTIVE: The purpose of this study was to assess the feasibility and efficacy of a functional substrate VT ablation strategy. METHODS: Patients with scar-related VT undergoing their first ablation were recruited. A closely coupled extrastimulus (ventricular effective refractory period + 30 ms) was delivered at the right ventricular apex while mapping with a high-density catheter. Sites of functional impaired conduction exhibited increased electrogram duration due to LPs/fractionation. The time to last deflection was annotated on an electroanatomic map, readily identifying ablation targets. RESULTS: A total of 40 patients were recruited (34 [85%] ischemic). Median procedure duration was 330 minutes (interquartile range [IQR] 300-369), and ablation time was 49.4 minutes (IQR 33.8-48.3). Median functional substrate area was 41.9 cm2 (IQR 22.1-73.9). It was similarly distributed across bipolar voltage zones. Noninducibility was achieved in 34 of 40 patients (85%). Median follow-up was 711 days (IQR 255.5-972.8), during which 35 of 39 patients (89.7%) did not have VT recurrence, and 3 of 39 (7.5%) died. Antiarrhythmic drugs were continued in 53.8% (21/39). CONCLUSION: Functional substrate ablation resulted in high rates of noninducibility and freedom from VT. Mapping times were increased considerably. Our findings add to the encouraging trend reported by related techniques. Randomized multicenter trials are warranted to assess this next phase of VT ablation.


Asunto(s)
Estimulación Cardíaca Artificial/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Frecuencia Cardíaca/fisiología , Ventrículos Cardíacos/fisiopatología , Taquicardia Ventricular/fisiopatología , Anciano , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Taquicardia Ventricular/terapia , Factores de Tiempo
7.
Ther Adv Gastrointest Endosc ; 13: 2631774520950840, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33150333

RESUMEN

OBJECTIVE: The endoscopic findings associated with Helicobacter pylori-naïve status, current infection or past infection are an area of ongoing interest. Previous studies have investigated parameters with a potential diagnostic value. The aim of this study was to perform meta-analysis of the available literature to validate the diagnostic accuracy of mucosal features proposed in the Kyoto classification. DATA SOURCES: The databases of MEDLINE and Embase, clinicalTrials.gov and the Cochrane Library were systematically searched for relevant studies from October 1999 to October 2019. METHODS: A bivariate random effects model was used to produce pooled diagnostic accuracy calculations for each of the studied endoscopic findings. Diagnostic odds ratios and sensitivity and specificity characteristics were calculated to identify significant predictors of H pylori status. RESULTS: Meta-analysis included 4380 patients in 15 studies. The most significant predictor of an H pylori-naïve status was a regular arrangement of collecting venules (diagnostic odds ratio 55.0, sensitivity 78.3%, specificity 93.8%). Predictors of active H pylori infection were mucosal oedema (18.1, 63.7%, 91.1%) and diffuse redness (14.4, 66.5%, 89.0%). Map-like redness had high specificity for previous H pylori eradication (99.0%), but poor specificity (13.0%). CONCLUSION: The regular arrangement of collecting venules, mucosal oedema, diffuse redness and map-like redness are important endoscopic findings for determining H pylori status. This meta-analysis provides a tentative basis for developing future endoscopic classification systems.

8.
Can J Cardiol ; 36(6): 822-836, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32536373

RESUMEN

This Canadian Cardiovascular Society position statement is focused on the management of sustained ventricular tachycardia (VT) and ventricular fibrillation (VF) that occurs in patients with structural heart disease (SHD), including previous myocardial infarction, dilated cardiomyopathy, and other forms of nonischemic cardiomyopathy. This patient population is rapidly increasing because of advances in care and improved overall survival of patients with all forms of SHD. In this position statement, the acute and long-term management of VT/VF are outlined, and the many unique aspects of care in this population are emphasized. The initial evaluation, acute therapy, indications for chronic suppressive therapy, choices of chronic suppressive therapy, implantable cardioverter-defibrillator programming, alternative therapies, and psychosocial care are reviewed and recommendations for optimal care are provided. The target audience for this statement includes all health professionals involved in the continuum of care of patients with SHD and VT/VF.


Asunto(s)
Cardiomiopatías/complicaciones , Muerte Súbita Cardíaca , Desfibriladores Implantables/efectos adversos , Manejo de Atención al Paciente/métodos , Taquicardia Ventricular , Fibrilación Ventricular , Canadá , Cardiomiopatías/clasificación , Cardiomiopatías/fisiopatología , Continuidad de la Atención al Paciente/organización & administración , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Técnicas de Diagnóstico Cardiovascular/instrumentación , Humanos , Comunicación Interdisciplinaria , Cuidados a Largo Plazo/métodos , Rehabilitación Psiquiátrica/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Taquicardia Ventricular/terapia , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia
9.
Clin Transl Gastroenterol ; 11(3): e00130, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32352708

RESUMEN

The progressive miniaturization of photonic components presents the opportunity to obtain unprecedented microscopic images of colonic polyps in real time during endoscopy. This information has the potential to act as "optical biopsy" to aid clinical decision-making, including the possibility of adopting new paradigms such as a "resect and discard" approach for low-risk lesions. The technologies discussed in this review include confocal laser endomicroscopy, optical coherence tomography, multiphoton microscopy, Raman spectroscopy, and hyperspectral imaging. These are in different stages of development and clinical readiness, but all show the potential to produce reliable in vivo discrimination of different tissue types. A structured literature search of the imaging techniques for colorectal polyps has been conducted. The significant developments in endoscopic imaging were identified for each modality, and the status of current development was discussed. Of the advanced imaging techniques discussed, confocal laser endomicroscopy is in clinical use and, under optimal conditions with an experienced operator, can provide accurate histological assessment of tissue. The remaining techniques show potential for incorporation into endoscopic equipment and practice, although further component development is needed, followed by robust prospective validation of accuracy. Optical coherence tomography illustrates tissue "texture" well and gives good assessment of mucosal thickness and layers. Multiphoton microscopy produces high-resolution images at a subcellular resolution. Raman spectroscopy and hyperspectral imaging are less developed endoscopically but provide a tissue "fingerprint" which can distinguish between tissue types. Molecular imaging may become a powerful adjunct to other techniques, with its ability to precisely label specific molecules within tissue and thereby enhance imaging.


Asunto(s)
Pólipos del Colon/diagnóstico , Colonoscopía/métodos , Mucosa Intestinal/diagnóstico por imagen , Lesiones Precancerosas/diagnóstico , Biopsia/métodos , Colon/patología , Pólipos del Colon/patología , Humanos , Mucosa Intestinal/patología , Microscopía Confocal/métodos , Microscopía de Fluorescencia por Excitación Multifotónica/métodos , Lesiones Precancerosas/patología , Estudios Prospectivos , Espectrometría Raman , Tomografía de Coherencia Óptica
10.
Endosc Int Open ; 8(2): E105-E114, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32010741

RESUMEN

Background and study aims There is growing interest in the endoscopic recognition of Helicobacter pylori infection, and application to routine practice. We present a systematic review of the current literature regarding diagnosis of H. pylori during standard (non-magnified) endoscopy, including adjuncts such as image enhancement and computer-aided diagnosis. Method The Medline and Cochrane databases were searched for studies investigating performance of non-magnified optical diagnosis for H. pylori , or those which characterized mucosal features associated with H. pylori infection. Studies were preferred with a validated reference test as the comparator, although they were included if at least one validated reference test was used. Results Twenty suitable studies were identified and included for analysis. In total, 4,703 patients underwent investigation including white light endoscopy, narrow band imaging, i-scan, blue-laser imaging, and computer-aided diagnostic techniques. The endoscopic features of H. pylori infection observed using each modality are discussed and diagnostic accuracies reported. The regular arrangement of collecting venules (RAC) is an important predictor of the H. pylori -naïve stomach. "Mosaic" and "mottled" patterns have a positive association with H. pylori infection. The "cracked" pattern may be a predictor of an H. pylori- negative stomach following eradication. Conclusions This review summarizes current progress made in endoscopic diagnosis of H. pylori infection. At present there is no single diagnostic approach that provides validated diagnostic accuracy. Further prospective studies are required, as is development of a validated classification system. Early studies in computer-aided diagnosis suggest potential for a high level of accuracy but real-time results are awaited.

11.
Ther Adv Gastrointest Endosc ; 13: 2631774520979591, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33426522

RESUMEN

Lower gastrointestinal endoscopy has evolved over time, fulfilling a widening diagnostic and therapeutic remit. As our understanding of colorectal cancer and its prevention has improved, endoscopy has progressed with improved diagnostic technologies and advancing endoscopic therapies. Despite this, the fundamental design of the endoscope has remained similar since its inception. This review presents the important role lower gastrointestinal endoscopy serves in the prevention of colorectal cancer and the desirable characteristics of the endoscope that would enhance this. A brief history of the endoscope is presented. Current and future robotic endoscopic platforms, which may fulfil these desirable characteristics, are discussed. The incorporation of new technologies from allied scientific disciplines will help the endoscope fulfil its maximum potential in preventing the increasing global burden of colorectal cancer. There are a number of endoscopic platforms under development, which show significant promise.

12.
J Clin Gastroenterol ; 53(7): 495-506, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-31107294

RESUMEN

BACKGROUND AND AIMS: Endoscopic imaging is a rapidly progressing field and benefits from miniaturization of advanced imaging technologies, which may allow accurate real-time characterization of lesions. The concept of the "optical biopsy" to predict polyp histology has gained prominence in recent years and may become clinically applicable with the advent of new imaging technology. This review aims to discuss current evidence and examine the emerging technologies as applied to the optical diagnosis of colorectal polyps. METHODS: A structured literature search and review has been carried out of the evidence for diagnostic accuracy of image-enhanced endoscopy and emerging endoscopic imaging technologies. The image-enhanced endoscopy techniques are reviewed, including their basic scientific principles and current evidence for effectiveness. These include the established image-enhancement technologies such as narrow-band imaging, i-scan, and Fuji intelligent chromoendoscopy. More recent technologies including optical enhancement, blue laser imaging, and linked color imaging are discussed. Adjunctive imaging techniques in current clinical use are discussed, such as autofluorescence imaging and endocytoscopy. The emerging advanced imaging techniques are reviewed, including confocal laser endomicroscopy, optical coherence tomography, and Raman spectroscopy. CONCLUSIONS: Large studies of the established image-enhancement techniques show some role for the optical diagnosis of polyp histology, although results have been mixed, and at present only the technique of narrow-band imaging is appropriate for the diagnosis of low-risk polyps when used by an expert operator. Other image-enhancement techniques will require further study to validate their accuracy but show potential to support the use of a "resect-and-discard" approach to low-risk polyps. New technologies show exciting potential for real-time diagnosis, but further clinical studies in humans have yet to be performed.


Asunto(s)
Pólipos del Colon/diagnóstico por imagen , Colonoscopía/métodos , Humanos , Aumento de la Imagen , Microscopía Confocal , Imagen de Banda Estrecha , Espectrometría Raman , Tomografía de Coherencia Óptica
13.
Therap Adv Gastroenterol ; 11: 1756284818814948, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30574190

RESUMEN

OBJECTIVE: i-Scan is a digital image enhancement technology, reported to improve diagnostic performance during endoscopy. Previous studies have investigated the accuracy of i-scan for distinguishing between neoplastic and non-neoplastic colonic polyps and suggested diagnostic accuracy close to that required for use in routine clinical practice. The aim of this study was to perform a meta-analysis of the available literature investigating diagnostic accuracy for i-scan optical diagnosis when made in real time for colorectal polyps <10 mm in size. DATA SOURCES: The databases of Medline, Embase and the Cochrane Library were searched for relevant studies. METHODS: A bivariate random effects model was used to produce pooled sensitivity and specificity values, and univariable meta-regression was applied for subgroup analysis. RESULTS: The meta-analysis included 15 studies, and diagnosis of 2817 polyps. The area under the hierarchical summary receiver-operating characteristic curve was 0.96. The pooled sensitivity of i-scan optical diagnosis was 0.92 (95% confidence interval 0.85-0.95). The specificity was 0.90 (95% confidence interval 0.83-0.94). CONCLUSIONS: This meta-analysis updates and summarizes the available evidence concerning the diagnostic performance of i-scan for small colorectal polyps. An acceptable degree of accuracy was found, showing potential to support a 'resect and discard' strategy for colonic polyps. There was not found to be a significant difference in diagnostic performance between different clinical settings (i.e. teaching hospitals or general hospitals).

15.
J Electrocardiol ; 44(6): 689-93, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22018484

RESUMEN

INTRODUCTION: A novel atrial defibrillator was developed at the Royal Victoria Hospital in collaboration with the Nanotechnology and Integrated Bio-Engineering Centre, University of Ulster. This device is powered by an external pulse of radiofrequency energy and designed to cardiovert using low-tilt monophasic waveform (LTMW) and low-tilt biphasic waveform (LTBW), 12 milliseconds pulse width. This study compared the safety and efficacy of LTMW with LTBW for transvenous cardioversion of atrial fibrillation (AF). METHODS: Patients were anticoagulated with warfarin to maintain International Normalized Ratio between 2 and 3 for 4 weeks prior cardioversion. Warfarin international normalized ratio level was maintained in between 2 and 3 for 4 weeks prior cardioversion. St Jude's defibrillating catheter was positioned in the distal coronary sinus and right atrium and connected to the defibrillator via a junction box. After a test shock using a dummy load, the patient was cardioverted in a step-up progression from 50 to 300 V. Shock success was defined as return of sinus rhythm for 30 seconds or more. If cardioversion was unsuccessful at peak voltage, the patient was crossed over to the other arm of the waveform type and cardioverted at peak voltage. RESULTS: Thirty patients were randomized equally to LTBW and LTMW (15 each). Seven out of 15 patients (46%) cardioverted to sinus rhythm with LTBW, and 1 (6%) of 15, with LTMW (P = .035). Including crossover patients, 14 patients (46%) converted to sinus rhythm. After crossover, 4 patients were cardioverted with LTBW and 2 with LTMW. Overall mean voltage, current, and energy used for cardioversion were 270.53 ± 35.96 V, 3.68 ± 0.80 A, and 9.12 ± 3.73 J, respectively, and intracardiac impedance was 70.82 ± 13.46 Ω. For patients who were successfully cardioverted, mean voltage, current, energy, and intracardiac impedance were 268.28 ± 42.41 V, 3.52 ± 0.63 A, 8.51 ± 3.16 J, and 73.92 ± 12.01 Ω. There were no major adverse complications during the study. Cardiac markers measured postcardioversion were unremarkable. CONCLUSION: Low-tilt biphasic waveform was more efficacious for low-energy transvenous cardioversion of AF. A significant proportion of patients were successfully cardioverted to sinus rhythm with low energy. Radiofrequency-powered defibrillation can be safely used for transvenous cardioversion of AF.


Asunto(s)
Fibrilación Atrial/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Anciano , Cateterismo Cardíaco , Cardioversión Eléctrica/instrumentación , Humanos , Persona de Mediana Edad , Warfarina/administración & dosificación
16.
Arch Med Sci ; 6(6): 991-2, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22427780

RESUMEN

Coronary artery perforation as a result of percutaneous coronary intervention is a rare complication which may result in cardiac tamponade, myocardial infarction and death. Perforation of a saphenous vein graft is unusual and generally requires surgical intervention. We describe a novel percutaneous approach that facilitated the successful management of a potentially catastrophic saphenous vein graft (SVG) perforation.

17.
Am J Cardiol ; 103(1): 22-8, 2009 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-19101224

RESUMEN

To evaluate the prognostic role of novel biomarkers for the risk stratification of patients admitted with ischemic-type chest pain, a prospective study of 664 patients presenting to 2 coronary care units with ischemic-type chest pain was conducted over 3 years beginning in 2003. Patients were assessed on admission for clinical characteristics, electrocardiographic findings, renal function, cardiac troponin T (cTnT), markers of myocyte injury (heart fatty acid-binding protein [H-FABP] and glycogen phosphorylase BB), neurohormonal activation (N-terminal-pro-brain natriuretic peptide [NT-pro-BNP]), hemostatic activity (fibrinogen and D-dimer), and vascular inflammation (high-sensitivity C-reactive protein, myeloperoxidase, matrix metalloproteinase-9, pregnancy-associated plasma protein-A, and soluble CD40 ligand). A >or=12-hour cTnT sample was also obtained. Myocardial infarction (MI) was defined as peak cTnT >or=0.03 microg/L. Patients were followed for 1 year from the time of admission. The primary end point was death or MI. Elevated fibrinogen, D-dimer, H-FABP, NT-pro-BNP, and peak cTnT were predictive of death or MI within 1 year (unadjusted odds ratios 2.5, 3.1, 5.4, 5.4, and 6.9, respectively). On multivariate analysis, H-FABP and NT-pro-BNP were selected, in addition to age, peak cTnT, and left ventricular hypertrophy on initial electrocardiography, as significant independent predictors of death or MI within 1 year. Patients without elevations of H-FABP, NT-pro-BNP, or peak cTnT formed a very low risk group in terms of death or MI within 1 year. A very high risk group had elevations of all 3 biomarkers. In conclusion, the measurement of H-FABP and NT-pro-BNP at the time of hospital admission for patients with ischemic-type chest pain adds useful prognostic information to that provided by the measurement of baseline and 12-hour cTnT.


Asunto(s)
Biomarcadores/sangre , Dolor en el Pecho/sangre , Proteínas de Unión a Ácidos Grasos/sangre , Hospitalización , Isquemia Miocárdica/complicaciones , Péptido Natriurético Encefálico/sangre , Fragmentos de Péptidos/sangre , Enfermedad Aguda , Anciano , Dolor en el Pecho/diagnóstico , Dolor en el Pecho/etiología , Electrocardiografía , Proteína 3 de Unión a Ácidos Grasos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/sangre , Isquemia Miocárdica/diagnóstico , Pronóstico , Estudios Prospectivos , Precursores de Proteínas , Factores de Riesgo
18.
Eur Heart J ; 29(23): 2843-50, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18682444

RESUMEN

AIMS: To evaluate the role of novel biomarkers in early detection of acute myocardial infarction (MI) in patients admitted with acute chest pain. METHODS AND RESULTS: A prospective study of 664 patients presenting to two coronary care units with chest pain was conducted over 3 years from 2003. Patients were assessed on admission: clinical characteristics, ECG (electrocardiogram), renal function, cardiac troponin T (cTnT), heart fatty acid binding protein (H-FABP), glycogen phosphorylase-BB, NT-pro-brain natriuretic peptide, D-dimer, hsCRP (high sensitivity C-reactive protein), myeloperoxidase, matrix metalloproteinase-9, pregnancy associated plasma protein-A, soluble CD40 ligand. A > or = 12 h cTnT sample was also obtained. MI was defined as cTnT > or = 0.03 microg/L. In patients presenting <4 h of symptom onset, sensitivity of H-FABP for MI was significantly higher than admission cTnT (73 vs. 55%; P = 0.043). Specificity of H-FABP was 71%. None of the other biomarkers challenged cTnT. Combined use of H-FABP and cTnT (either one elevated initially) significantly improved the sensitivities of H-FABP or cTnT (85%; P < or = 0.004). This combined approach also improved the negative predictive value, negative likelihood ratio, and the risk ratio. CONCLUSION: Assessment of H-FABP within the first 4 h of symptoms is superior to cTnT for detection of MI, and is a useful additional biomarker for patients with acute chest pain.


Asunto(s)
Angina Inestable/diagnóstico , Proteínas de Unión a Ácidos Grasos/metabolismo , Infarto del Miocardio/diagnóstico , Péptido Natriurético Encefálico/metabolismo , Troponina T/metabolismo , Biomarcadores/metabolismo , Dolor en el Pecho/etiología , Electrocardiografía , Métodos Epidemiológicos , Proteína 3 de Unión a Ácidos Grasos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
19.
Indian Pacing Electrophysiol J ; 5(4): 289-95, 2005 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-16943878

RESUMEN

The modern generation of transthoracic defibrillators now employ impedance compensated biphasic waveforms. These new devices are superior to those with monophasic waveforms and practice is currently switching to biphasic defibrillators for the treatment of both ventricular and atrial fibrillation. However, there is no universal guideline for the use of biphasic defibrillators in direct current cardioversion of atrial fibrillation. This article reviews the use of biphasic defibrillation waveforms for transthoracic cardioversion of atrial fibrillation.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...