Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Z Geburtshilfe Neonatol ; 205(4): 143-6, 2001.
Artículo en Alemán | MEDLINE | ID: mdl-11570194

RESUMEN

BACKGROUND: We analysed retrospectively whether the total cervix occlusion implicates efficient the prolongation of pregnancy in patients with bulging fetal membranes during extreme prematurity. PATIENTS AND METHODS: Between 1993 and 1999 nineteen pregnant women (17 singleton and 2 twin pregnancies) with cervical incompetence and bulging membranes at 20 to 27 weeks' gestation (mean 24 weeks) underwent total cervix occlusion (TCO) at the Department of Obstetrics at the Technische Universität of Munich after taking cervical cultures, prophylactic antibiotic treatment, tocolysis and induction of fetal lung maturity (after 33 weeks of gestational age). RESULTS: Eleven of nineteen pregnancies were carried beyond 32 weeks' gestation. 6 of 21 fetuses, included 2 twin pregnancies died. Considering the perinatal mortality the mean prolongation of pregnancy was 9.4 weeks after total cervix occlusion. 9 of 19 pregnant women were delivered beyond 37 weeks of gestational age. CONCLUSION: Taking the small number and the lack of a randomized trial into consideration, these results implicate the total cervix occlusion as an efficient method in cases of bulging membranes during extreme prematurity. Nevertheless a thorough postoperative control and screening of infectious complications are required.


Asunto(s)
Cuello del Útero/cirugía , Trabajo de Parto Prematuro/cirugía , Incompetencia del Cuello del Útero/cirugía , Adulto , Cuello del Útero/diagnóstico por imagen , Terapia Combinada , Femenino , Humanos , Recién Nacido , Trabajo de Parto Prematuro/diagnóstico por imagen , Embarazo , Segundo Trimestre del Embarazo , Embarazo Múltiple , Estudios Retrospectivos , Técnicas de Sutura , Tocólisis , Resultado del Tratamiento , Ultrasonografía Prenatal , Incompetencia del Cuello del Útero/diagnóstico por imagen
2.
Gynecol Oncol ; 77(1): 78-86, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10739694

RESUMEN

OBJECTIVE: Transvaginal sonography is limited in its ability to assess early stage cancers of the ovary as well as in distinguishing benign processes. As a method for characterization of tumor vascularization, color-coded Doppler sonography may be able to improve the diagnostic accuracy of B-mode sonography. METHODS: Preoperative transvaginal B-mode and Doppler sonography was performed in 63 patients with unclear adnexal lesions prior to operation. Using multiple logistic regression, the independent variables of each procedure were selected and combined to yield a diagnostic flow chart. The diagnostic accuracy of this decision matrix was tested on 257 patients with unclear adnexal tumors. RESULTS: In the 63 adnexal tumors investigated, the diagnostic impact of isolated sonomorphological assessment with evidence of a "solid area" was 78%. Using Doppler sonography, the best discrimination was achieved by displaying the vascular distribution ("central vascularization"). Combining these independent significant variables of the two procedures raised the diagnostic accuracy to 90% (sensitivity 86%, specificity 93%). The validity achieved by this combination was confirmed by the independent application of this method to the 257 adnexal tumors with unclear malignancy status (diagnostic accuracy 93%, sensitivity 92%, specificity 94%). CONCLUSIONS: The combination of sonography and Doppler sonography achieves high and reproducible diagnostic accuracy in preoperative malignancy status assessment of adnexal tumors. The additional use of Doppler sonography can thus provide significant aid both for differential diagnostics of adnexal lesions and for the choice of surgical route in the case of an existing indication for operative therapy.


Asunto(s)
Neoplasias Ováricas/diagnóstico por imagen , Ultrasonografía Doppler en Color/métodos , Vagina/diagnóstico por imagen , Enfermedades de los Anexos/diagnóstico por imagen , Enfermedades de los Anexos/patología , Adulto , Diagnóstico Diferencial , Femenino , Humanos , Modelos Logísticos , Sensibilidad y Especificidad
3.
Z Orthop Ihre Grenzgeb ; 136(3): 221-5, 1998.
Artículo en Alemán | MEDLINE | ID: mdl-9736982

RESUMEN

UNLABELLED: Since 1979 prenatal ultrasonography is a screening method in Germany. The examination of head, thorax and femur is now established as a routine method. AIM OF THE STUDY: The evaluation of the effectiveness and the consequences of an early prenatal diagnosis of foetal limb deficiencies. METHOD: From 1989-1994 we had 403 children with 207 minor or 196 major limb deficiencies. Questionnaires were sent to those 196 parents of children with major diseases 134 cases (68%) of children with limb deficiencies could be analysed. The average age of the mother at birth was 27.5 years and the age of the father was 30.5 years. RESULTS: 61 children had deficiencies of the upper limb. another 61 of the lower limbs and 12 had combined defects of the limbs. The mothers had 5.6 (1-15) prenatal ultrasounds examinations. In 63% (n = 82) these were performed by the obstetric practitioners, in 30% in departments of obstetrics and 7% in a university hospital. In 5.2% only, the limb deficiency was diagnosed antenataly. CONCLUSION: If there are any unclear findings the women should be sent to a centre of prenatal diagnostics. In cases of congenital deficiencies of the limbs there is the possibility] for the parents to combined to combined consultation of the obstetrician, the human genetic and the orthopaedic to plan the treatment and talk about all consequences.


Asunto(s)
Ectromelia/diagnóstico por imagen , Tamizaje Neonatal , Ultrasonografía Prenatal , Estudios Transversales , Diagnóstico Diferencial , Ectromelia/epidemiología , Femenino , Alemania/epidemiología , Humanos , Incidencia , Recién Nacido , Masculino , Grupo de Atención al Paciente , Embarazo
4.
Ultrasound Obstet Gynecol ; 10(1): 48-53, 1997 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9263423

RESUMEN

To optimize the sensitivity and specificity of gray-scale imaging and color Doppler in breast tumor diagnosis, alone and in combination, 89 women with palpable breast masses were scanned preoperatively and standard parameters were determined in both modes. Parameters significant for differentiation of benign and malignant tumors identified using univariate analysis were combined and weighted using multivariate analysis (multiple logistic regression). Histologically 59 tumors were malignant and 30 benign. Gray-scale sonography alone achieved a sensitivity of 88% and a specificity of 96% using the parameters of wall structure and posterior acoustic attenuation. Color Doppler achieved a sensitivity of 85% and a specificity of 79% using resistance index and pulsatility index as parameters. Combination of both methods yielded an accurate diagnosis in 84/87 patients (sonographic lesion correlates were absent in two cases), equivalent to a sensitivity of 97% and a specificity of 96%. Thus the individual diagnostic performance of gray-scale imaging and color Doppler sonography in palpable breast disease is further enhanced using multiple logistic regression to combine independently significant parameters.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Lobular/diagnóstico por imagen , Fibroadenoma/diagnóstico por imagen , Ultrasonografía Doppler en Color , Adulto , Anciano , Anciano de 80 o más Años , Biopsia con Aguja , Velocidad del Flujo Sanguíneo , Neoplasias de la Mama/irrigación sanguínea , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/irrigación sanguínea , Carcinoma Ductal de Mama/cirugía , Carcinoma Lobular/irrigación sanguínea , Carcinoma Lobular/cirugía , Diagnóstico Diferencial , Femenino , Fibroadenoma/irrigación sanguínea , Fibroadenoma/cirugía , Enfermedad Fibroquística de la Mama/irrigación sanguínea , Enfermedad Fibroquística de la Mama/diagnóstico por imagen , Humanos , Menopausia , Persona de Mediana Edad , Análisis Multivariante , Factores de Riesgo , Sensibilidad y Especificidad
5.
Geburtshilfe Frauenheilkd ; 55(3): 156-9, 1995 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-7665063

RESUMEN

The aim of the present study was to determine the correlation of cotinine levels in amniotic fluid and in fetal and corresponding maternal blood samples. Amniotic fluid samples (N = 130) were taken during second trimester amniocentesis, umbilical artery blood samples (N = 75) at birth, both together with corresponding maternal blood samples. Self-reported smokers showed maternal serum cotinine levels > 15 ng/ml in 93%, self-reported nonsmokers levels < 15 ng/ml in 89%. Correlation of corresponding values for cotinine was 0.81-0.92. Cotinine values were increased in fetal blood and amniotic fluid in comparison to maternal serum levels. Despite the fact that pathophysiology is not fully understood, an accumulation of nicotine and its metabolites both in the fetus and in the amniotic fluid appears to be evident.


Asunto(s)
Líquido Amniótico/metabolismo , Cotinina/farmacocinética , Sangre Fetal/metabolismo , Intercambio Materno-Fetal/fisiología , Fumar/sangre , Amniocentesis , Femenino , Humanos , Recién Nacido , Nicotina/efectos adversos , Nicotina/farmacocinética , Embarazo , Segundo Trimestre del Embarazo , Fumar/efectos adversos , Contaminación por Humo de Tabaco/efectos adversos
6.
Gynakol Geburtshilfliche Rundsch ; 35 Suppl 1: 36-41, 1995.
Artículo en Alemán | MEDLINE | ID: mdl-8672924

RESUMEN

OBJECTIVES: This study was performed to prove, if the use of methods, that are based on procedures for analysis of chaotic systems ("complexity analysis"), can give information on the fetal condition during birth and predict both the course of delivery and fetal outcome. PATIENTS AND METHODS: Fetal ECG was derived in 37 pregnancies (36-42 weeks of gestation) during birth for two to seven hours. In 12 cases delivery was uncomplicated, in 24 cases FHR tracings had been pathological. RESULTS: Complexity analysis of fetal ECG signals showed within short observation intervals criteria that may be a hint for imminent fetal distress and acidosis. CONCLUSIONS: Application of complexity analysis in the future may give additional information for evaluation of intrapartum CTG in cases of suspicious FHR patterns.


Asunto(s)
Cardiotocografía/instrumentación , Electrocardiografía/instrumentación , Sufrimiento Fetal/diagnóstico , Procesamiento de Señales Asistido por Computador , Adulto , Femenino , Sufrimiento Fetal/fisiopatología , Edad Gestacional , Frecuencia Cardíaca Fetal/fisiología , Humanos , Recién Nacido , Embarazo , Resultado del Embarazo , Embarazo de Alto Riesgo
8.
Geburtshilfe Frauenheilkd ; 54(1): 27-33, 1994 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-8150247

RESUMEN

In a study group of 41 pregnant women of postpartally confirmed placental abruption, the prognostic value of clinical and diagnostic findings was investigated. The incidence of placental abruption was 1.4% of all deliveries within a three-year interval. 51% of patients showed vaginal bleeding before delivery. Retroplacental haematoma was found in 49% of cases ultrasonographically. A total of 75% had a pathological CTG test. More than 95% of these findings occurred within 3 days before delivery. Abnormal Doppler flow findings in foetal vessels more than 3 days before delivery were seen in 62% of cases. In the last three days before delivery, 86% were abnormal. Preterm delivery before 37 weeks of gestation was registered in 82% of patients. Perinatal mortality amounted to 12%. The rate of severely dystrophic newborn was 30%. Even in cases with lack of the clinical and/or sonographical findings, the possibility of placental abruption should be considered, if an acute deterioration of cardiotocographic or Doppler-sonographic findings.


Asunto(s)
Desprendimiento Prematuro de la Placenta/diagnóstico , Monitoreo Fetal/métodos , Desprendimiento Prematuro de la Placenta/mortalidad , Desprendimiento Prematuro de la Placenta/fisiopatología , Cardiotocografía , Cesárea , Femenino , Muerte Fetal/patología , Feto/irrigación sanguínea , Edad Gestacional , Humanos , Recién Nacido , Intercambio Materno-Fetal/fisiología , Placenta/patología , Placenta/fisiopatología , Preeclampsia/diagnóstico , Preeclampsia/mortalidad , Preeclampsia/fisiopatología , Embarazo , Estudios Retrospectivos , Ultrasonografía Prenatal
9.
Z Geburtshilfe Perinatol ; 197(2): 90-4, 1993.
Artículo en Alemán | MEDLINE | ID: mdl-8328173

RESUMEN

Analysis of more than 2500 doppler flow signals in three patients was performed to evaluate the influence of fetal heart rate (fhr) variation on S/D-ratio in fetal vessels. Little differences of S/D-ratio in fetal vessels (descending aorta, umbilical arteries) were detected within the physiological variations of fhr (120-160 bpm) (envelope of regression line -0.007, -0.006). Analysing inter- as well as intraindividual variation only minor effects of fhr alteration can be observed in clinical application of doppler flow velocimetry. Dopplersonographic measurements, however, should be performed for at least a three minute period (for each vessel) to avoid false-positive or false-negative interpretation of short term changes of doppler signals. This is especially important in distressed fetuses.


Asunto(s)
Retardo del Crecimiento Fetal/diagnóstico por imagen , Frecuencia Cardíaca Fetal/fisiología , Intercambio Materno-Fetal/fisiología , Preeclampsia/diagnóstico por imagen , Ultrasonografía Prenatal , Adulto , Aorta/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Cardiotocografía , Femenino , Retardo del Crecimiento Fetal/fisiopatología , Humanos , Recién Nacido , Preeclampsia/fisiopatología , Embarazo , Valores de Referencia , Procesamiento de Señales Asistido por Computador , Arterias Umbilicales/diagnóstico por imagen
12.
Geburtshilfe Frauenheilkd ; 51(9): 734-40, 1991 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-1743474

RESUMEN

The endometrial carcinoma shows an increasing incidence and represents today the most frequent malignoma of the female pelvis. Until now all techniques of detection of this carcinoma or its precursors are invasive and thus are not suitable for screening investigations. Vaginosonography, as the first non-invasive diagnostic method, now supplies knowledge about the state of the endometrium. At the Gynaecological Department of the University of Homburg/Saar, West Germany, 221 patients had been preoperatively subjected to vaginosonography before they underwent surgery. Sonographical and histological findings corresponded in atrophic endometrium in 82%, in regular, perimenopausal endometrium in 91%, in endometrial polyps and hyperplasia of the endometrium in 56%, and in endometrial carcinoma in 79%. With regard to the detection of endometrial cancer, a specificity of 96%, a sensitivity of 93%, a positive predictive value of 79% and an accuracy of 96% were established. Thus, according to our experience, vaginosonography represents a valid, non-invasive diagnostical method as a suitable instrument for screening the endometrium.


Asunto(s)
Neoplasias Endometriales/diagnóstico por imagen , Menopausia/fisiología , Ultrasonografía/instrumentación , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Hiperplasia Endometrial/diagnóstico por imagen , Hiperplasia Endometrial/cirugía , Neoplasias Endometriales/cirugía , Endometrio/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Pólipos/diagnóstico por imagen , Pólipos/cirugía
13.
Geburtshilfe Frauenheilkd ; 51(7): 523-31, 1991 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-1936860

RESUMEN

Of 1950 pregnant patients (2870 Doppler ultrasound measurements) we observed, in a study group with highly abnormal Doppler-flow findings (n = 66, Feb. 1990), a correlation of Doppler flow and FHR-recordings. Among these 66 patients we retained 60 (91%) in the hospital. They had at least 2 FHR-recordings a day. The results of Doppler flow measurements in the fetal aorta and umbilical artery correlated well with diagnosis of IUGR. The comparison of the overall results of both fetal vessels did not indicate any significant difference. In 21% of all patients with highly abnormal Doppler flow findings, was no abnormal FHR record until delivery. 26% already showed an abnormal non-stress test before the first pathological Doppler assessment, in 44% abnormal FHR-recordings were observed later than the first abnormal Doppler flow finding in the course of pregnancy. The median interval was 13.5 days in cases with increased Doppler flow parameters but with detectable end-diastolic blood flow and was reduced to 8 days in cases with absent end-diastolic blood flow. In 9% of all cases, abnormal results were found with both methods on the same day. In 32% we observed a reproducible notch in Doppler flow velocimetry of uteroplacental vessels. The rate of congenital malformations was 14%. Thus abnormal Doppler flow signals can be estimated as "early" prognostic criterias for a compromised fetus at risk.


Asunto(s)
Cardiotocografía/instrumentación , Retardo del Crecimiento Fetal/diagnóstico por imagen , Frecuencia Cardíaca Fetal/fisiología , Intercambio Materno-Fetal/fisiología , Procesamiento de Señales Asistido por Computador/instrumentación , Ultrasonografía Prenatal/instrumentación , Peso al Nacer , Velocidad del Flujo Sanguíneo/fisiología , Aberraciones Cromosómicas/diagnóstico por imagen , Aberraciones Cromosómicas/fisiopatología , Trastornos de los Cromosomas , Gráficos por Computador , Femenino , Retardo del Crecimiento Fetal/fisiopatología , Edad Gestacional , Humanos , Recién Nacido , Microcomputadores , Embarazo , Factores de Riesgo
14.
Geburtshilfe Frauenheilkd ; 51(6): 437-42, 1991 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-1889727

RESUMEN

160 woman patients in whom the course of pregnancy was uneventful or pathological (intrauterine growth retardation, percentile less than 5) were investigated at the Department of Obstetrics and Gynaecology of the University of Homburg/Saar between the 28th and 42nd week of pregnancy, using a newly developed cardiotocograph (HP M1350A Hewlett-Packard, Böblingen, FRG). By means of the kinetocardiotocogram (KCTG), fetal mobility (fetal movements of the whole body or of the extremities) was recorded simultaneously with the conventional recording of the fetal heart rate and uterine contractions. One of the aims in developing the KCTG was to record as far as possible all fetal movements synchronous to the recordings of heart rate and uterine contractions. To this end, the recording algorithm of the KCTG was adapted to the examination results obtained by two simultaneously operating ultrasound investigators. After the 28th week of pregnancy it was possible to record by the KCTG fetal "movement clusters" (combined body and limb movements) independent of the weight of the fetus and of amniotic fluid volume or positional anomalies, reliably and with good correlation with the results of the sonographic control investigations (r = 0.88-0.97). In cases of intrauterine growth retardation (percentile less than 5) a significantly reduced motility was observed on average as early as 13 days before delivery (p less than 0.005). It must be emphasized that, at this stage, most of the antenatal CTGs were normal. These findings indicate that KCTG can contribute to improved monitoring in high-risk pregnancies.


Asunto(s)
Cardiotocografía/instrumentación , Retardo del Crecimiento Fetal/diagnóstico , Movimiento Fetal/fisiología , Ultrasonografía Prenatal/instrumentación , Desarrollo Embrionario y Fetal/fisiología , Femenino , Retardo del Crecimiento Fetal/fisiopatología , Corazón Fetal/fisiopatología , Frecuencia Cardíaca Fetal , Humanos , Recién Nacido , Embarazo , Valores de Referencia
15.
Ultraschall Med ; 12(3): 134-8, 1991 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-1925498

RESUMEN

"Reverse Flow" as a Doppler sonographic finding indicates the appearance of retrograde blood flow in the diastolic part of the cardiac cycle. It has so far not been observed in uncomplicated pregnancies and seems to be an indicator of severe deterioration of the foetal condition. Several pathophysiological hypotheses are discussed in this paper on the basis of own results and the findings of other investigators.


Asunto(s)
Retardo del Crecimiento Fetal/diagnóstico por imagen , Hemodinámica/fisiología , Interpretación de Imagen Asistida por Computador/instrumentación , Intercambio Materno-Fetal/fisiología , Ultrasonografía Prenatal/instrumentación , Arterias Umbilicales/diagnóstico por imagen , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Muerte Fetal/diagnóstico por imagen , Muerte Fetal/fisiopatología , Retardo del Crecimiento Fetal/fisiopatología , Humanos , Recién Nacido , Placenta/irrigación sanguínea , Insuficiencia Placentaria/diagnóstico por imagen , Insuficiencia Placentaria/fisiopatología , Preeclampsia/diagnóstico por imagen , Preeclampsia/fisiopatología , Embarazo , Arterias Umbilicales/fisiopatología , Resistencia Vascular/fisiología
16.
Geburtshilfe Frauenheilkd ; 51(5): 357-61, 1991 May.
Artículo en Alemán | MEDLINE | ID: mdl-1869003

RESUMEN

This study describes a comparison between two different ultrasound methods used to localize a low-lying placenta or a placenta previa. The methods implemented were the abdominal ultrasound and the so-called "perineal scan", an ultrasound examination of the female urogenital tract, which is performed by using the perineum as an acoustic window. Between 1985 and 1988, 84 patients, suspected of having a low-lying placenta, were examined by perineal scanning. In all these cases it was possible to compare the results with those of abdominal ultrasound examinations documented in the patient's records. The "perineal scan"-examinations were performed "blind", i.e., without knowledge of the results of prior abdominal ultrasound. Abdominal sonography was performed by a different examiner using the full-bladder-technique. Perineal scanning was done a short time after voiding. The results showed considerable and significant (p less than 0.001) discrepancies between the two methods; perineal scanning more often demonstrated higher grade diagnoses (27 patients, 32%) than vice versa (9 patients, 11%). These differences may be at least partially explained by the influence of bladder distension. Probably a full bladder produces false negative results more often than previously suspected. An analysis of pregnancy outcome yielded positive predictive values of 78% (abdominal ultrasound) and 86% (perineal scanning). Perineal scanning therefore seems to provide an uncomplicated and reliable means to verify an abdominal placenta localisation.


Asunto(s)
Placenta Previa/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Cesárea , Femenino , Edad Gestacional , Humanos , Recién Nacido , Placenta/diagnóstico por imagen , Embarazo
17.
Geburtshilfe Frauenheilkd ; 51(4): 288-92, 1991 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-1860660

RESUMEN

In 50 cases with an end-diastolic zero flow or reverse flow all antenatal and perinatal abnormalities have been recorded. The fetal outcome was registered. The percentage of highly dystrophic newborns (percentile less than 5) was 88%. The perinatal mortality counted up to 16% and the percentage of congenital malformations (including chromosomal anomalies) was 12%. A reverse flow was registered in 4 cases. The perinatal mortality of those cases with reverse flow was 100%. In approx. one-quarter of those pregnancies and in 50% of the perinatally deceased newborns, there were no pathological or suspicious changes in the antepartal and/or subpartal CTG-recordings. The Duplex sonographical diagnosis of an end-diastolic zero flow/reverse flow, has a highly positive predictive value, whereas its sensitivity is low. It can be regarded as a very helpful parameter in clinical diagnosis, particularly as it is independent of borderline values. The correct choice of the high-pass wall filter (50-100 Hz) is important.


Asunto(s)
Diástole/fisiología , Retardo del Crecimiento Fetal/diagnóstico por imagen , Hemodinámica/fisiología , Intercambio Materno-Fetal/fisiología , Preeclampsia/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador/instrumentación , Ultrasonografía Prenatal/métodos , Adulto , Aorta/diagnóstico por imagen , Aorta/fisiopatología , Peso al Nacer , Velocidad del Flujo Sanguíneo/fisiología , Cesárea , Femenino , Retardo del Crecimiento Fetal/fisiopatología , Edad Gestacional , Humanos , Recién Nacido , Preeclampsia/fisiopatología , Embarazo , Arterias Umbilicales/diagnóstico por imagen , Arterias Umbilicales/fisiopatología
18.
Z Geburtshilfe Perinatol ; 195(2): 61-4, 1991.
Artículo en Alemán | MEDLINE | ID: mdl-1887653

RESUMEN

The influence of fetal position, the site of placenta and the site of measurement in the fetal aorta on doppler-flow parameters was investigated in patients with uncomplicated pregnancies. In 20 cases the S/D-ratio was obtained in three different regions of the descending aorta. Measurements superior the renal vessels showed comparable values (4.1-4.3). No differences were found between signals obtained cranial or caudal of the diaphragma. Measurements at the aortal bifurcation showed significantly increased median values (6.6, p less than 0.05). No differences could be obtained concerning the influence of fetal position or site of placenta on S/D-ratio. All median values of a total of 197 patients were in the range of 4.8. Therefore it may be concluded that the above mentioned parameters do not have significant influence on doppler flow parameters in fetal vessels. However, a proximal site of measurement in the descending aorta fetalis should be reassured.


Asunto(s)
Aorta/diagnóstico por imagen , Presentación en Trabajo de Parto , Intercambio Materno-Fetal/fisiología , Placenta/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Aorta/embriología , Velocidad del Flujo Sanguíneo/fisiología , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/instrumentación , Placenta/irrigación sanguínea , Embarazo , Tercer Trimestre del Embarazo , Valores de Referencia , Ultrasonografía Prenatal/instrumentación
19.
Geburtshilfe Frauenheilkd ; 51(3): 217-22, 1991 Mar.
Artículo en Alemán | MEDLINE | ID: mdl-1711490

RESUMEN

7000 pregnancies were analysed after genetic amniocentesis in respect of the further course and results of prenatal diagnosis (observation period 1975-1988). In 3.1% (217 cases) samples of amniotic fluid were discoloured. Vaginal haemorrhages prior to amniocentesis were recorded with significantly higher incidence (18%) in patients with discoloured amniotic fluid than in a control group (n = 217) with normal colour of the amniotic fluid (4.6%) (p less than 0.001). Miscarriages and chromosome anomalies occurred more often in the study group (3.7%/2.8%, control group: 0.9%/1.8%, n.s.). The risk of miscarriages was increased in cases with sanguineous amniotic fluid if the amniotic fluid alpha-fetoprotein values were enhanced at the same time. Significant differences were observed in respect of the incidence of foetal malformations in patients with discoloured amniotic fluid (7.8%) and in the control group (2.3%) (p less than 0.01). Borderline or definitely pathological amniotic fluid AFP concentrations were found often if the amniotic fluid was discoloured (6.9%, control group 3.2%). If discoloured amniotic fluid was sampled, foetal malformations should be excluded sonographically. In 82% of all cases with discoloured amniotic fluid and foetal malformations pathological sonographic findings and/or enhanced MS-AFP values were recorded even prior to amniocentesis.


Asunto(s)
Amniocentesis/métodos , Aberraciones Cromosómicas/diagnóstico , Aberraciones Cromosómicas/genética , Trastornos de los Cromosomas , Femenino , Edad Gestacional , Humanos , Recién Nacido , Cariotipificación , Edad Materna , Defectos del Tubo Neural/diagnóstico , Defectos del Tubo Neural/genética , Polihidramnios/diagnóstico , Polihidramnios/etiología , Embarazo , alfa-Fetoproteínas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA