Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Niger J Clin Pract ; 23(9): 1237-1242, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32913162

RESUMEN

AIMS: We evaluated and compared EndoActivator, CanalBrush, and passive ultrasonic irrigation (PUI) in the removal of calcium hydroxide and calcium hydroxide with iodoform and p-chlorophenol paste (Calcipast Forte) from artificial standardized grooves in the apical third of root canals. MATERIALS AND METHODS: A total of 34 mandibular premolars were prepared and then split longitudinally. A standardized groove was prepared in the apical part of both segments. The grooves were filled with either calcium hydroxide or Calcipast Forte, and the segments were reassembled. CanalBrush, EndoActivator, or PUI were used. The amount of remaining medicament was evaluated using a four-grade scoring system. RESULTS: None of the irrigation methods could completely remove the pastes from the grooves. More Calcipast Forte paste was detected compared with calcium hydroxide (P < 0.01). PUI was the least effective method in removing Calcipast Forte. CONCLUSIONS: It was more difficult to remove Calcipast Forte than a water-based calcium hydroxide paste.


Asunto(s)
Hidróxido de Calcio/química , Clorofenoles , Cavidad Pulpar/patología , Hidrocarburos Yodados , Materiales de Obturación del Conducto Radicular/química , Irrigantes del Conducto Radicular/administración & dosificación , Terapia por Ultrasonido/métodos , Humanos , Irrigantes del Conducto Radicular/química , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Irrigación Terapéutica/métodos , Terapia por Ultrasonido/instrumentación , Ultrasonido , Agua
2.
J Refract Surg ; 14(1): 26-30, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9531082

RESUMEN

OBJECTIVE: To evaluate the efficacy and predictability of laser in situ keratomileusis (LASIK) for hyperopia in a prospective study of 54 eyes of 29 patients. METHODS: Before LASIK, 44 eyes (81.48%) had a spectacle-corrected visual acuity of 20/20 or better, and 54 eyes (100%) had 20/40 or better. Surgery was performed under topical anesthesia using the Keracor 116 excimer laser and Chiron automated corneal shaper. Mean follow-up was 19 months. RESULTS: Mean baseline uncorrected hyperopia was +6.50 +/- 1.33 D (range, +4.25 to +8.00 D). Mean uncorrected manifest spherical equivalent refraction was +0.44 +/- 1.95 D at 18 months after LASIK. Twenty-one eyes (38.8%) were within +/-0.50 D of emmetropia, 41 eyes (75.92%) were within +/-1.00 D, and 47 eyes (87.03%) were within +/-2.00 at 18 months after LASIK. Uncorrected visual acuity was 20/20 or better in eight eyes (14.81%) and 20/40 or better in 36 eyes (66.66%) 18 months after LASIK. Regression and undercorrection of more than 2.00 D occurred in seven eyes (12.9%) between the 3 and 6 month examinations; three of these seven eyes (42.8%) required retreatment to correct residual hyperopia. Three eyes (6.8%) lost two or more lines of spectacle-corrected visual acuity. CONCLUSION: Excimer laser keratomileusis in situ with the Keracor 116 appears to be an effective and safe procedure to decrease low and moderate hyperopia, but the predictability of the procedure needs improvement.


Asunto(s)
Córnea/cirugía , Trasplante de Córnea/métodos , Hiperopía/cirugía , Terapia por Láser , Adulto , Córnea/patología , Córnea/fisiopatología , Topografía de la Córnea , Estudios de Seguimiento , Humanos , Hiperopía/fisiopatología , Persona de Mediana Edad , Complicaciones Posoperatorias , Estudios Prospectivos , Refracción Ocular/fisiología , Reoperación , Seguridad , Resultado del Tratamiento , Agudeza Visual/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA