Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Immunol ; 13: 903903, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35720401

RESUMEN

In the present study, the levels of serum and airway soluble chemokines, pro-inflammatory/regulatory cytokines, and growth factors were quantified in critically ill COVID-19 patients (total n=286) at distinct time points (D0, D2-6, D7, D8-13 and D>14-36) upon Intensive Care Unit (ICU) admission. Augmented levels of soluble mediators were observed in serum from COVID-19 patients who progress to death. An opposite profile was observed in tracheal aspirate samples, indicating that systemic and airway microenvironment diverge in their inflammatory milieu. While a bimodal distribution was observed in the serum samples, a unimodal peak around D7 was found for most soluble mediators in tracheal aspirate samples. Systems biology tools further demonstrated that COVID-19 display distinct eccentric soluble mediator networks as compared to controls, with opposite profiles in serum and tracheal aspirates. Regardless the systemic-compartmentalized microenvironment, networks from patients progressing to death were linked to a pro-inflammatory/growth factor-rich, highly integrated center. Conversely, patients evolving to discharge exhibited networks of weak central architecture, with lower number of neighborhood connections and clusters of pro-inflammatory and regulatory cytokines. All in all, this investigation with robust sample size landed a comprehensive snapshot of the systemic and local divergencies composed of distinct immune responses driven by SARS-CoV-2 early on severe COVID-19.


Asunto(s)
COVID-19 , Enfermedad Crítica , Citocinas/metabolismo , Humanos , Cinética , SARS-CoV-2
2.
Front Immunol ; 13: 795815, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35493505

RESUMEN

In the present work, we developed and evaluated the performance of a new flow cytometry-based single platform, referred to as "FC-Duplex IgG1 (HTLV-1/2)", for universal and differential serodiagnosis of HTLV-1/2 infection. The proposed technology employs a system for detection of IgG1 antibodies in a single competitive immunofluorescence platform by flow cytometry using fluorescently labeled MT-2/MoT cell line mix coupled to a highly sensitive development system (Biotin/Streptavidin/Phycoerythrin). The stability of fluorescent labeling and the antigenicity of MT-2 and MoT cell lines were confirmed upon storage at -20°C for 2, 6, and 12 months. The anti-HTLV-1/2 IgG1 reactivity, expressed as percentage of positive fluorescent cells (PPFC), was evaluated for each target antigen along the titration curve of test serum samples (1:32 to 1:4,096). Upon selection of target cell line and serum dilutions with higher segregation score between groups, the performance of "FIX" and "FIX & PERM" protocols was evaluated. The "FIX" protocol presented excellent performance indices (Se = 92%/Sp = 94%/AUC = 0.96; Se = 96%/Sp = 100%/AUC = 0.99) for the universal (HTLV-1/2 vs. NI) and differential (HTLV-1 vs. HTLV-2) diagnosis of HTLV-1 infection, respectively. Optimization of the "FIX" protocol using the principle of synchronous and asynchronous pairwise analysis further improved the performance of "FC-Duplex IgG1 (HTLV-1/2)", using the "FIX" protocol for differential diagnosis of HTLV-1 and HTLV-2 infections (Se = 100%/Sp = 100%/AUC = 1.00). In conclusion, the "FC-Duplex IgG1 (HTLV-1/2)" method represents an innovation in the biotechnology segment with the potential to compose a serological kit for differential diagnosis of HTLV-1/2 infection for reference laboratories and blood centers.


Asunto(s)
Infecciones por HTLV-I , Virus Linfotrópico T Tipo 1 Humano , Citometría de Flujo/métodos , Infecciones por HTLV-I/diagnóstico , Humanos , Inmunoglobulina G , Pruebas Serológicas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...