Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Polymers (Basel) ; 15(13)2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37447578

RESUMEN

Wearable electronic sensors have attracted considerable interest in hand motion monitoring because of their small size, flexibility, and biocompatibility. However, the range of motion and sensitivity of many sensors are inadequate for complex and precise finger motion capture. Here, organic and inorganic materials were incorporated to fabricate a hybrid electronic sensor and optimized and woven into fabric for hand motion detection. The sensor was made from flexible porous polydimethylsiloxane (PDMS) filled with multiwalled carbon nanotubes (MWCNTs). The weight ratios of MWCNTs and geometric characteristics were optimized to improve the hybrid electronic sensor, which showed a high elongation at the breaking point (i.e., more than 100%) and a good sensitivity of 1.44. The strain-related deformation of the PDMS/MWCNT composite network resulted in a variation in the sensor resistance; thus, the strain level that corresponds to different finger motions is be calculated. Finally, the fabricated and optimized electronic sensor in filiform structure with a 6% MWCNT ratio was integrated with smart fabric to create a finger sleeve for real-time motion capture. In conclusion, a novel hybrid E-fiber sensor based on PDMS and MWCNTs was successfully fabricated in the current study with an optimal M/P ratio and structure, and textile techniques were adopted as new packaging approaches for such soft electronic sensors to create smart fabric for wearable and precise detection with highly enhanced sensing performance. The successful results in the current study demonstrate the great potential of such hybrid soft sensors in smart wearable healthcare management, including motion detection.

2.
Polymers (Basel) ; 14(14)2022 Jul 07.
Artículo en Inglés | MEDLINE | ID: mdl-35890561

RESUMEN

A robotic digit with shape modulation, allowing personalized and adaptable finger motions, can be used to restore finger functions after finger trauma or neurological impairment. A soft pneumatic robotic digit consisting of pneumatic bellows actuators as biomimetic artificial joints is proposed in this study to achieve specific finger motions. A parametric kinematic model is employed to describe the tip motion trajectory of the soft pneumatic robotic digit and guide the actuator parameter design (i.e., the pressure supply, actuator material properties, and structure requirements of the adopted pneumatic bellows actuators). The direct 3D printing technique is adopted in the fabrication process of the soft pneumatic robotic digit using the smart material of thermoplastic polyurethane. Each digit joint achieves different ranges of motion (ROM; bending angles of distal, proximal, and metacarpal joint are 107°, 101°, and 97°, respectively) under a low pressure of 30 kPa, which are consistent with the functional ROM of a human finger for performing daily activities. Theoretical model analysis and experiment tests are performed to validate the effectiveness of the digit parametric kinematic model, thereby providing evidence-based technical parameters for the precise control of dynamic pressure dosages to achieve the required motions.

3.
Sensors (Basel) ; 22(7)2022 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35408323

RESUMEN

Copper ion is closely associated with the ecosystem and human health, and even a little excessive dose in drinking water may result in a range of health problems. However, it remains challenging to produce a highly sensitive, reliable, cost-effective and electromagnetic-interference interference-immune device to detect Cu2+ ion in drinking water. In this paper, a taper-in-taper fiber sensor was fabricated with high sensitivity by mode-mode interference and deposited polyelectrolyte layers for Cu2+ detection. We propose a new structure which forms a secondary taper in the middle of the single-mode fiber through two-arc discharge. Experimental results show that the newly developed fiber sensor possesses a sensitivity of 2741 nm/RIU in refractive index (RI), exhibits 3.7 times sensitivity enhancement when compared with traditional tapered fiber sensors. To apply this sensor in copper ions detection, the results present that when the concentration of Cu2+ is 0-0.1 mM, the sensitivity could reach 78.03 nm/mM. The taper-in-taper fiber sensor exhibits high sensitivity with good stability and mechanical strength which has great potential to be applied in the detection of low Cu2+ ions in some specific environments such as drinking water.


Asunto(s)
Agua Potable , Fibras Ópticas , Cobre , Ecosistema , Humanos , Iones
4.
Micromachines (Basel) ; 12(12)2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34945443

RESUMEN

To precisely achieve a series of daily finger bending motions, a soft robotic finger corresponding to the anatomical range of each joint was designed in this study with multi-material pneumatic actuators. The actuator as a biomimetic artificial joint was developed on the basis of two composite materials of different shear modules, and the pneumatic bellows as expansion parts was restricted by frame that made from polydimethylsiloxane (PDMS). A simplified mathematical model was used for the bending mechanism description and provides guidance for the multi-material pneumatic actuator fabrication (e.g., stiffness and thickness) and structural design (e.g., cross length and chamber radius), as well as the control parameter optimization (e.g., the air pressure supply). An actuation pressure of over 70 kPa is required by the developed soft robotic finger to provide a full motion range (MCP = 36°, PIP = 114°, and DIP = 75°) for finger action mimicking. In conclusion, a multi-material pneumatic actuator was designed and developed for soft robotic finger application and theoretically and experimentally demonstrated its feasibility in finger action mimicking. This study explored the mechanical properties of the actuator and could provide evidence-based technical parameters for pneumatic robotic finger design and precise control of its dynamic air pressure dosages in mimicking actions. Thereby, the conclusion was supported by the results theoretically and experimentally, which also aligns with our aim to design and develop a multi-material pneumatic actuator as a biomimetic artificial joint for soft robotic finger application.

5.
Micromachines (Basel) ; 13(1)2021 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-35056184

RESUMEN

An opto-microfluidic static pressure sensor based on a fiber Fabry-Perot Interferometer (FPI) with extended air cavity for enhancing the measuring sensitivity is proposed. The FPI is constructed in a microfluidic channel by the combination of the fixed fiber-end reflection and floating liquid surface reflection faces. A change of the aquatic pressure will cause a drift of the liquid surface and the pressure can be measured by detecting the shift of the FPI spectrum. Sensitivity of the sensor structure can be enhanced significantly by extending the air region of the FPI. The structure is manufactured by using a common single-mode optical fiber, and a silica capillary with the inner wall coated with a hydrophobic film. A sample with 3500 µm air cavity length has demonstrated the pressure sensitivity of about 32.4 µm/kPa, and the temperature cross-sensitivity of about 0.33 kPa/K.

6.
Sensors (Basel) ; 20(17)2020 Aug 28.
Artículo en Inglés | MEDLINE | ID: mdl-32872111

RESUMEN

Secondary injuries are common during upper limb rehabilitation training because of uncontrollable physical force and overexciting activities, and long-time training may cause fatigue and reduce the training effect. This study proposes a wearable monitoring device for upper limb rehabilitation by integrating electrocardiogram and electromyogram (ECG/EMG) sensors and using data acquisition boards to obtain accurate signals during robotic glove assisting training. The collected ECG/EMG signals were filtered, amplified, digitized, and then transmitted to a remote receiver (smart phone or laptop) via a low-energy Bluetooth module. A software platform was developed for data analysis to visualize ECG/EMG information, and integrated into the robotic glove control module. In the training progress, various hand activities (i.e., hand closing, forearm pronation, finger flexion, and wrist extension) were monitored by the EMG sensor, and the changes in the physiological status of people (from excited to fatigue) were monitored by the ECG sensor. The functionality and feasibility of the developed physiological monitoring system was demonstrated by the assisting robotic glove with an adaptive strategy for upper limb rehabilitation training improvement. The feasible results provided a novel technique to monitor individual ECG and EMG information holistically and practically, and a technical reference to improve upper limb rehabilitation according to specific treatment conditions and the users' demands. On the basis of this wearable monitoring system prototype for upper limb rehabilitation, many ECG-/EMG-based mobile healthcare applications could be built avoiding some complicated implementation issues such as sensors management and feature extraction.


Asunto(s)
Electrocardiografía , Rehabilitación de Accidente Cerebrovascular , Dispositivos Electrónicos Vestibles , Electromiografía , Humanos , Monitoreo Fisiológico , Extremidad Superior
7.
Micromachines (Basel) ; 10(12)2019 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-31835484

RESUMEN

Wearable sensing technologies have been developed rapidly in the last decades for physiological and biomechanical signal monitoring. Much attention has been paid to functions of wearable applications, but comfort parameters have been overlooked. This research presents a developed fabric temperature sensor by adopting fiber Bragg grating (FBG) sensors and processing via a textile platform. This FBG-based quasi-distributed sensing system demonstrated a sensitivity of 10.61 ± 0.08 pm/°C with high stability in various temperature environments. No obvious wavelength shift occurred under the curvatures varying from 0 to 50.48 m-1 and in different integration methods with textiles. The temperature distribution monitored by the developed textile sensor in a complex environment with multiple heat sources was deduced using MATLAB to present a real-time dynamic temperature distribution in the wearing environment. This novel fabric temperature sensor shows high sensitivity, stability, and usability with comfort textile properties that are of great potential in wearable applications.

8.
Materials (Basel) ; 12(20)2019 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-31614542

RESUMEN

Emerging smart textiles have enriched a variety of wearable technologies, including fiber optic technology. Optic fibers are widely applied in communication, sensing, and healthcare, and smart textiles enable fiber optic technology to be worn close to soft and curved human body parts for personalized functions. This review briefly introduces wearable fiber optic applications with various functions, including fashion and esthetics, vital signal monitoring, and disease treatment. The main working principles of side emission, wavelength modulation, and intensity modulation are summarized. In addition, textile fabrication techniques, including weaving and knitting, are discussed and illustrated as combination methods of embedding fiber optic technology into textile fabric. In conclusion, the combination of optical fibers and textiles has drawn considerable interest and developed rapidly. This work provides an overview of textile-based wearable fiber optic technology and discusses potential textile fabrication techniques for further improvement of wearable fiber optic applications.

9.
Artículo en Inglés | MEDLINE | ID: mdl-30906410

RESUMEN

PURPOSE: This systematic review and meta-analysis was conducted to investigate the effects of various acutherapies on knee osteoarthritis (KOA) relief in the elderly. METHODS: Five databases were accessed from inception to July 2017 for searching randomized controlled trials (RCTs) on acutherapy for KOA relief in the elderly. Data were pooled after trial quality assessment for meta-analysis. Outcomes were the scores of knee pain, knee stiffness, and physical function accessed by Western Ontario and McMaster Universities Osteoarthritis (WOMAC) Index. RESULTS: 17 RCTs including 4774 subjects were included. The results indicated that acutherapy significantly affected knee pain (standardized mean difference, i.e., SMD = - 0.73, [95% CI, -0.98 to -0.47], P <0.001), knee stiffness (SMD = -0.66, [95%CI, -0.85 to -0.47], P <0.001), and physical function (SMD = -1.56, [95%CI, -2.17 to -0.95], P<0.001) when compared with control condition without intervention of any acutherapy. Moreover, acutherapy was more effective than corresponding sham (placebo) intervention applied on nonacupoints (SMD = -0.16, [95% CI, -0.32 to -0.01], P = 0.04). However, no significant differences were found on treatment effects between acutherapy and sham acutherapy at the same acupoints (SMD= - 0.09, [95%CI, -0.40 to 0.21], P = 0.55). CONCLUSIONS: Acutherapy was an effective approach for KOA relief in the elderly. The selection of acupoints position could be a crucial factor that influences the treatment efficacy of acutherapy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...