1.
Diagn Interv Imaging ; 104(10): 465-476, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37345961

RESUMEN

PURPOSE: The purpose of this study was to develop and test across various scanners a zone-specific region-of-interest (ROI)-based computer-aided diagnosis system (CAD) aimed at characterizing, on MRI, International Society of Urological Pathology (ISUP) grade≥2 prostate cancers. MATERIALS AND METHODS: ROI-based quantitative models were selected in multi-vendor training (265 pre-prostatectomy MRIs) and pre-test (112 pre-biopsy MRIs) datasets. The best peripheral and transition zone models were combined and retrospectively assessed in internal (158 pre-biopsy MRIs) and external (104 pre-biopsy MRIs) test datasets. Two radiologists (R1/R2) retrospectively delineated the lesions targeted at biopsy in test datasets. The CAD area under the receiver operating characteristic curve (AUC) for characterizing ISUP≥2 cancers was compared to that of the Prostate Imaging-Reporting and Data System version2 (PI-RADSv2) score prospectively assigned to targeted lesions. RESULTS: The best models used the 25th apparent diffusion coefficient (ADC) percentile in transition zone and the 2nd ADC percentile and normalized wash-in rate in peripheral zone. The PI-RADSv2 AUCs were 82% (95% confidence interval [CI]: 74-87) and 86% (95% CI: 81-91) in the internal and external test datasets respectively. They were not different from the CAD AUCs obtained with R1 and R2 delineations, in the internal (82% [95% CI: 76-89], P = 0.95 and 85% [95% CI: 78-91], P = 0.55) and external (82% [95% CI: 74-91], P = 0.41 and 86% [95% CI:78-95], P = 0.98) test datasets. The CAD yielded sensitivities of 86-89% and 90-91%, and specificities of 64-65% and 69-75% in the internal and external test datasets respectively. CONCLUSION: The CAD performance for characterizing ISUP grade≥2 prostate cancers on MRI is not different from that of PI-RADSv2 score across two test datasets.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Masculino , Humanos , Próstata/patología , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética , Imagen de Difusión por Resonancia Magnética , Computadores
2.
Diagn Interv Imaging ; 103(11): 545-554, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35773099

RESUMEN

PURPOSE: The purpose of this study was to quantify the influence of factors of variability on apparent diffusion coefficient (ADC) estimation in the normal prostate peripheral zone (PZ). MATERIALS AND METHODS: Fifty healthy volunteers underwent in 2017 (n = 17) or 2020 (n = 33) two-point (0, 800 s/mm²) prostate diffusion-weighted imaging in the morning on 1.5 T scanners A and B from different manufacturers. Additional five-point (50, 150, 300, 500, 800 s/mm²) acquisitions were performed on scanner B in the morning and evening. ADC was measured in PZ at midgland using ADC maps reconstructed with various b-value combinations. ADC distributions from 2017 and 2020 were compared using Wilcoxon rank sum test. ADC obtained in the same volunteers were compared using Bland Altman methodology. The 95% confidence interval upper limit of the repeatability/reproducibility coefficient defined the lowest detectable ADC difference. RESULTS: Forty-nine participants with a mean age of 24.6 ± 3.8 [SD] years (range: 21-37 years) were finally included. ADC distributions from 2017 and 2020 were not significantly different and were combined. Despite high individual variability, there was no significant bias (10 × 10-6 mm²/s, P = 0.58) between ADC measurements made on both scanners. On scanner B, differences in lowest b-values chosen within the 0-500 s/mm² range for two-point ADC computation induced significant biases (56-109 × 10-6 mm²/s, P < 0.0001). ADC was significantly lower in the morning (bias: 33 × 10-6 mm²/s, P = 0.006). The number of b-values had little influence on ADC values. The lowest detectable ADC difference varied from 85 × 10-6 to 311 × 10-6 mm²/s across scanners, b-value combinations and periods of the day. CONCLUSIONS: The MRI scanner, the lowest b-value used and the period of the day induce substantial variability in ADC computation.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Adulto Joven , Adulto , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Voluntarios Sanos