Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Mater Sci Eng C Mater Biol Appl ; 44: 362-70, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25280716

RESUMEN

In this study, the "Gum Metal" titanium-based alloy (Ti-23Nb-0.7Ta-2Zr-1.2O) was synthesized by melting and then characterized in order to evaluate its potential for biomedical applications. Thus, the mechanical properties, the corrosion resistance in simulated body fluid and the in vitro cell response were investigated. It was shown that this alloy presents a very high strength, a low Young's modulus and a high recoverable strain by comparison with the titanium alloys currently used in medicine. On the other hand, all electrochemical and corrosion parameters exhibited more favorable values showing a nobler behavior and negligible toxicity in comparison with the commercially pure Ti taken as reference. Furthermore, the biocompatibility tests showed that this alloy induced an excellent response of MC3T3-E1 pre-osteoblasts in terms of attachment, spreading, viability, proliferation and differentiation. Consequently, the "Gum Metal" titanium-based alloy processes useful characteristics for the manufacturing of highly biocompatible medical devices.


Asunto(s)
Materiales Biocompatibles/química , Titanio/química , Células 3T3-L1 , Aleaciones/química , Animales , Líquidos Corporales/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Módulo de Elasticidad/efectos de los fármacos , Técnicas Electroquímicas , Ensayo de Materiales/métodos , Ratones , Osteoblastos/efectos de los fármacos , Titanio/farmacología
2.
Mater Sci Eng C Mater Biol Appl ; 33(7): 4173-82, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23910330

RESUMEN

In this study, a superelastic Ni-free Ti-based biomedical alloy was treated in surface by the implantation of nitrogen ions for the first time. The N-implanted surface was characterized by X-ray diffraction, X-ray photoelectron spectroscopy, and secondary ion mass spectroscopy, and the superficial mechanical properties were evaluated by nano-indentation and by ball-on-disk tribological tests. To investigate the biocompatibility, the corrosion resistance of the N-implanted Ti alloy was evaluated in simulated body fluids (SBF) complemented by in-vitro cytocompatibility tests on human fetal osteoblasts. After implantation, surface analysis methods revealed the formation of a titanium-based nitride on the substrate surface. Consequently, an increase in superficial hardness and a significant reduction of friction coefficient were observed compared to the non-implanted sample. Also, a better corrosion resistance and a significant decrease in ion release rates have been obtained. Cell culture experiments indicated that the cytocompatibility of the N-implanted Ti alloy was superior to that of the corresponding non-treated sample. Thus, this new functional N-implanted titanium-based superelastic alloy presents the optimized properties that are required for various medical devices: superelasticity, high superficial mechanical properties, high corrosion resistance and excellent cytocompatibility.


Asunto(s)
Aleaciones/farmacología , Tecnología Biomédica/métodos , Elasticidad , Nitrógeno/química , Titanio/farmacología , Líquidos Corporales/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Corrosión , Feto/citología , Fibronectinas/biosíntesis , Fricción , Dureza , Humanos , L-Lactato Deshidrogenasa/metabolismo , Osteoblastos/citología , Osteoblastos/efectos de los fármacos , Osteoblastos/enzimología , Espectroscopía de Fotoelectrones , Potenciometría , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción/efectos de los fármacos , Difracción de Rayos X
3.
J Mater Sci Mater Med ; 23(12): 2953-66, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22918550

RESUMEN

In this study, the new Hardion+ micro-implanter technology was used to modify surface properties of biomedical pure titanium (CP-Ti) and Ti-6Al-4V ELI alloy by implantation of nitrogen ions. This process is based on the use of an electron cyclotron resonance ion source to produce a multienergetic ion beam from multicharged ions. After implantation, surface analysis methods revealed the formation of titanium nitride (TiN) on the substrate surfaces. An increase in superficial hardness and a significant reduction of friction coefficient were observed for both materials when compared to non-implanted samples. Better corrosion resistance and a significant decrease in ion release rates were observed for N-implanted biomaterials due to the formation of the protective TiN layer on their surfaces. In vitro tests performed on human fetal osteoblasts indicated that the cytocompatibility of N-implanted CP-Ti and Ti-6Al-4V alloy was enhanced in comparison to that of the corresponding non treated samples. Consequently, Hardion+ implantation technique can provide titanium alloys with better qualities in terms of corrosion resistance, cell proliferation, adhesion and viability.


Asunto(s)
Aleaciones/química , Nitrógeno/química , Titanio/química , Materiales Biocompatibles/química , Adhesión Celular , Proliferación Celular , Supervivencia Celular , Corrosión , Matriz Extracelular/metabolismo , Fibronectinas/química , Humanos , Iones , Espectrometría de Masas/métodos , Ensayo de Materiales , Nitrógeno/metabolismo , Osteoblastos/citología , Prótesis e Implantes , Propiedades de Superficie , Temperatura
4.
J Mech Behav Biomed Mater ; 3(8): 559-64, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20826361

RESUMEN

In this study, a new Ti-25Ta-25Nb (mass%) beta alloy was synthesised by cold crucible semi-levitation melting. This technique made it possible to obtain homogeneous ingots although the elements used have very different melting points. After melting, a thermo-mechanical treatment was applied in order to obtain a perfectly recrystallised beta microstructure. For this alloy composition, the tensile tests showed a very low Young's modulus associated with an important super-elastic behaviour, which contributes to decrease the elastic modulus under stress and to increase the recoverable strain. On the other hand, the corrosion tests, which were carried out in a neutral Ringer solution, indicated a corrosion resistance higher than that of the commercially pure CP Ti alloy. These results show that this new alloy possesses all the characteristics necessary for its long-term use in medical implants.


Asunto(s)
Aleaciones/síntesis química , Materiales Biocompatibles Revestidos/síntesis química , Elasticidad , Corrosión , Soluciones Isotónicas/química , Niobio/química , Solución de Ringer , Estrés Mecánico , Tantalio/química , Temperatura , Resistencia a la Tracción , Titanio/química
5.
J Mech Behav Biomed Mater ; 1(4): 345-51, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19627799

RESUMEN

We have synthesized titanium-based alloys containing molybdenum and tantalum elements by powder metallurgy. The microstructure, the residual porosity and the mechanical properties of the sintered Ti-Mo and Ti-Ta-Mo alloys were investigated by using optical and electronic microscopy, X-ray diffraction, microhardness and compression tests. The cytocompatibility of the different alloys was evaluated by the assessment of bone cell density, migration and adhesion after 14 days incubation. All the alloys present a high ductility and an excellent cytocompatibility, which make these materials useful for medical implants.


Asunto(s)
Aleaciones/química , Aleaciones/farmacología , Osteoblastos/citología , Osteoblastos/efectos de los fármacos , Tantalio/química , Tantalio/farmacología , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Células Cultivadas , Módulo de Elasticidad , Dureza , Humanos , Ensayo de Materiales , Propiedades de Superficie
6.
J Mater Sci Mater Med ; 15(8): 885-91, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15477740

RESUMEN

Ti-based biocompatible alloys are especially used for replacing failed hard tissue. Some of the most actively investigated materials for medical implants are the beta-Ti alloys, as they have a low elastic modulus (to inhibit bone resorption). They are alloyed with elements such as Nb, Ta, Zr, Mo, and Fe. We have prepared a new beta-Ti alloy that combines Ti with the non-toxic elements Ta and Mo using a vacuum arc-melting furnace and then annealed at 950 degrees C for one hour. The alloy was finally quenched in water at room temperature. The Ti-12Mo-5Ta alloy was characterised by X-ray diffraction, optical microscopy, SEM and EDS and found to have a body-centred-cubic structure (beta-type). It had a lower Young's modulus (about 74 GPa) than the classical alpha/beta Ti-6Al-4V alloy (120 GPa), while its Vickers hardness remained very high (about 303 HV). This makes it a good compromise for a use as a bone substitute. The cytocompatibility of samples of Ti-12Mo-5Ta and Ti-6Al-4V titanium alloys with various surface roughnesses was assessed in vitro using organotypic cultures of bone tissue and quantitative analyses of cell migration, proliferation and adhesion. Mechanically polished surfaces were prepared to produce unorientated residual polished grooves and cells grew to a particularly high density on the smoother Ti-12Mo-5Ta surface tested.


Asunto(s)
Sustitutos de Huesos/química , Osteoblastos/citología , Osteoblastos/fisiología , Titanio/química , Animales , Ingeniería Biomédica/métodos , Adhesión Celular/fisiología , Movimiento Celular/fisiología , Proliferación Celular , Supervivencia Celular/fisiología , Células Cultivadas , Embrión de Pollo , Elasticidad , Dureza , Ensayo de Materiales , Conformación Molecular , Propiedades de Superficie , Tibia/citología , Tibia/crecimiento & desarrollo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA