Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Funct Biomater ; 12(2)2021 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-34068852

RESUMEN

Titanium alloys are widely used for biomedical applications due to their good biocompatibility. Nevertheless, they cannot be used for balloon expandable stents due to a lack of ductility compared to cobalt-chromium (Co-Cr) alloys and stainless steels. In this study, a new highly deformable Ti-16Nb-8Mo alloy was designed for such an application. However, the biological performance of a stent material is strongly influenced by the effect exerted on the behavior of endothelial cells. Therefore, the cellular responses of human umbilical vein endothelial cells (HUVECs), including morphological characteristics, cell viability and proliferation, and functional markers expression, were investigated to evaluate the biocompatibility of the alloy in the present study. The in vitro results demonstrated the suitability of this alloy for use as endovascular stents.

2.
J Biomed Mater Res B Appl Biomater ; 107(5): 1483-1490, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30265783

RESUMEN

To enhance their longevity, dental implants must be highly biocompatible and must have a low elastic modulus close to that of the bone. They must also possess a high superficial hardness and a high corrosion resistance. For these reasons, a recently developed low-modulus Ti-27Nb alloy with nontoxic elements was treated by gas nitriding at high temperature in this study. A very thin nitrided layer of 0.5 µm in thickness followed by an enriched nitrogen zone was observed. Consequently, a very high hardness evaluated at about 1800 HV was obtained in surface, which represents an increase of 4-5 times the hardness of the non-nitrided alloy. This superficial hardness was experimentally observed to decrease up to 800 nm in depth from the surface to the core. The low modulus of Ti-27Nb (evaluated at 55 GPa, which is twice lower than the commercially pure titanium) was not affected by the surface nitriding treatment. A better corrosion resistance was observed and a significant decrease in ion release rates for the nitrided alloy (ion release of 1.41 ng/cm2 compared to the 163.58 ng/cm2 obtained for the commercially pure titanium at pH = 7.48 in artificial Carter-Brugirard saliva). The cytocompatibility was not compromised and the cell viability performed on human osteoblasts, fibroblastic cells, and epithelial cells was enhanced on the nitrided surface in comparison with the non-nitrided surface. These combined properties make the nitrided Ti-27Nb alloy a good candidate for dental implant applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1483-1490, 2019.


Asunto(s)
Aleaciones , Implantes Dentales , Ensayo de Materiales , Titanio , Aleaciones/química , Aleaciones/farmacología , Animales , Línea Celular Tumoral , Humanos , Ratones , Niobio/química , Niobio/farmacología , Titanio/química , Titanio/farmacología
3.
Mater Sci Eng C Mater Biol Appl ; 62: 686-91, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26952473

RESUMEN

Surface nitriding was demonstrated to be an effective process for improving the biocompatibility of implantable devices. In this study, we investigated the benefits of nitriding the NiTi shape memory alloy for vascular stent applications. Results from cell experiments indicated that, compared to untreated NiTi, a superficial gas nitriding treatment enhanced the adhesion of human umbilical vein endothelial cells (HUVECs), cell spreading and proliferation. This investigation provides data to demonstrate the possibility of improving the rate of endothelialization on NiTi by means of nitride coating.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Níquel/química , Titanio/química , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/farmacología , Células Endoteliales de la Vena Umbilical Humana , Humanos , Ensayo de Materiales , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Microscopía Fluorescente , Níquel/farmacología , Propiedades de Superficie , Titanio/farmacología
4.
Materials (Basel) ; 9(10)2016 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-28773939

RESUMEN

A new superelastic Ti-23Hf-3Mo-4Sn biomedical alloy displaying a particularly large recovery strain was synthesized and characterized in this study. Its native passive film is very thick (18 nm) and contains very protective TiO2, Ti2O3, HfO2, MoO2, and SnO2 oxides (XPS analysis). This alloy revealed nobler electrochemical behavior, more favorable values of the corrosion parameters and open circuit potentials in simulated body fluid in comparison with commercially pure titanium (CP-Ti) and Ti-6Al-4V alloy taken as reference biomaterials in this study. This is due to the favorable influence of the alloying elements Hf, Sn, Mo, which enhance the protective properties of the native passive film on alloy surface. Impedance spectra showed a passive film with two layers, an inner, capacitive, barrier, dense layer and an outer, less insulating, porous layer that confer both high corrosion resistance and bioactivity to the alloy. In vitro tests were carried out in order to evaluate the response of Human Umbilical Vein Endothelial Cells (HUVECs) to Ti-23Hf-3Mo-4Sn alloy in terms of cell viability, cell proliferation, phenotypic marker expression and nitric oxide release. The results indicate a similar level of cytocompatibility with HUVEC cells cultured on Ti-23Hf-3Mo-4Sn substrate and those cultured on the conventional CP-Ti and Ti-6Al-4V metallic materials.

5.
Biomed Res Int ; 2015: 261802, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26583096

RESUMEN

The influence of gas nitriding surface treatment on the superelastic Ti-23Nb-0.7Ta-2Zr-0.5N alloy was evaluated. A thorough characterization of bare and nitrided Ti-based alloy and pure Ti was performed in terms of surface film composition and morphology, electrochemical behaviour, and short term osteoblast response. XPS analysis showed that the nitriding treatment strongly influenced the composition (nitrides and oxynitrides) and surface properties both of the substrate and of the bulk alloy. SEM images revealed that the nitrided surface appears as a similar dotted pattern caused by the formation of N-rich domains coexisting with less nitrided domains, while before treatment only topographical features could be observed. All the electrochemical results confirmed the high chemical stability of the nitride and oxynitride coating and the superiority of the applied treatment. The values of the corrosion parameters ascertained the excellent corrosion resistance of the coated alloy in the real functional conditions from the human body. Cell culture experiments with MG63 osteoblasts demonstrated that the studied biomaterials do not elicit any toxic effects and support cell adhesion and enhanced cell proliferation. Altogether, these data indicate that the nitrided Ti-23Nb-0.7Ta-2Zr-0.5N alloy is the most suitable substrate for application in bone implantology.


Asunto(s)
Aleaciones/uso terapéutico , Osteoblastos/efectos de los fármacos , Prótesis e Implantes , Titanio/uso terapéutico , Aleaciones/química , Materiales Biocompatibles , Interfase Hueso-Implante , Proliferación Celular/efectos de los fármacos , Humanos , Ensayo de Materiales , Propiedades de Superficie , Titanio/química
6.
Mater Sci Eng C Mater Biol Appl ; 47: 105-13, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25492178

RESUMEN

New ß-titanium based alloys with low Young's modulus are currently required for the next generation of metallic implant materials to ensure good mechanical compatibility with bone. Several of these are representatives of the ternary Ti-Mo-Nb system. The aim of this paper is to assess the in vitro biological performance of five new low modulus alloy compositions, namely Ti12Mo, Ti4Mo32Nb, Ti6Mo24Nb, Ti8Mo16Nb and Ti10Mo8Nb. Commercially pure titanium (cpTi) was used as a reference material. Comparative studies of cell activity exhibited by MC3T3-E1 pre-osteoblasts over short- and long-term culture periods demonstrated that these newly-developed metallic substrates exhibited an increased biocompatibility in terms of osteoblast proliferation, collagen production and extracellular matrix mineralization. Furthermore, all analyzed biomaterials elicited an almost identical cell response. Considering that macrophages play a pivotal role in bone remodeling, the behavior of a monocyte-macrophage cell line, RAW 264.7, was also investigated showing a slightly lower inflammatory response to Ti-Mo-Nb biomaterials as compared with cpTi. Thus, the biological performances together with the superior mechanical properties recommend these alloys for bone implant applications.


Asunto(s)
Aleaciones/química , Molibdeno/química , Niobio/química , Titanio/química , Células 3T3 , Animales , Técnicas In Vitro , Macrófagos/citología , Ratones
7.
Mater Sci Eng C Mater Biol Appl ; 35: 411-9, 2014 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-24411395

RESUMEN

The materials used for internal fracture fixations and joint replacements are mainly made of metals which still face problems ranging from higher rigidity than that of natural bone to leaching cytotoxic metallic ions. Beta (ß)-type titanium alloys with low elastic modulus made from non-toxic and non-allergenic elements are desirable to reduce stress shielding effect and enhance bone remodeling. In this work, a new ß-type Ti-23Nb-0.7Ta-2Zr-0.5N alloy with a Young's modulus of approximately 50 GPa was designed and characterized. The behavior of MC3T3-E1 pre-osteoblasts on the new alloy, including adhesion, proliferation and differentiation, was evaluated by examining the cytoskeleton, focal adhesion formation, metabolic activity and extracellular matrix mineralization. Results indicated that the pre-osteoblast cells exhibited a similar degree of attachment and growth on Ti-23Nb-0.7Ta-2Zr-0.5N and Ti-6Al-4V. However, the novel alloy proved to be significantly more efficient in sustaining mineralized matrix deposition upon osteogenic induction of the cells than Ti-6Al-4V control. Further, the analysis of RAW 264.7 macrophages cytokine gene and protein expression indicated no significant inflammatory response. Collectively, these findings suggest that the Ti-23Nb-0.7Ta-2Zr-0.5N alloy, which has an increased mechanical biocompatibility with bone, allows a better osteogenic differentiation of osteoblast precursor cells than Ti-6Al-4V and holds great potential for future clinical prosthetic applications.


Asunto(s)
Macrófagos/inmunología , Níquel/química , Osteoblastos/inmunología , Titanio/química , Células 3T3 , Aleaciones/síntesis química , Animales , Adhesión Celular/inmunología , Proliferación Celular , Supervivencia Celular/inmunología , Módulo de Elasticidad , Macrófagos/citología , Ratones , Osteoblastos/citología , Propiedades de Superficie
8.
Mater Sci Eng C Mater Biol Appl ; 32(6): 1554-63, 2012 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-24364960

RESUMEN

Among metallic materials used as bone substitutes, ß titanium alloys gain an increasing importance because of their low modulus, high corrosion resistance and good biocompatibility. In this work, an investigation of the in vitro cytocompatibility of a recently new developed ß-type Ti-25Ta-25Nb alloy was carried out by evaluating the behavior of human osteoblasts. The metallic Ti-6Al-4V biomaterial, which is one of representative α+ß type titanium alloys for biomedical applications, and Tissue Culture Polystyrene (TCPS), were also investigated as reference Ti-based material and control substrate, respectively. Both metallic surfaces were analyzed by X-ray diffraction, atomic force microscopy and X-ray photoelectron spectroscopy. The cellular response was quantified by assessments of viability, cell attachment and spreading, cell morphology, production and extracellular organization of fibronectin and cell proliferation. Polished surfaces from both materials having an equiaxed grain microstructure and nanometre scale surface roughness elicited an essentially identical osteoblast response in terms of all analyzed cellular parameters. Thus, on both surfaces the cells displayed high survival rates, good cell adhesion and spreading, a dense and randomly dispersed fibronectin matrix and increasing cell proliferation rates over the incubation time. Furhermore, the enhanced biological performance of Ti-25Ta-25Nb was highly supported by the results obtained in comparison with TCPS. These findings, together with previously shown superelastic behavior, low Young's modulus and high corrosion resistance, recommend Ti-25Ta-25Nb as good candidate for applications in bone implantology.


Asunto(s)
Aleaciones/química , Osteoblastos/fisiología , Titanio/química , Materiales Biocompatibles/química , Huesos/fisiología , Adhesión Celular/fisiología , Proliferación Celular , Células Cultivadas , Humanos , Ensayo de Materiales/métodos , Espectroscopía de Fotoelectrones/métodos , Tasa de Supervivencia , Difracción de Rayos X/métodos
9.
J Mater Sci Mater Med ; 21(11): 2907-13, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20711847

RESUMEN

To evaluate the potential of ß-Ti20Mo alloy as a dental material, we tested its corrosion behaviour in artificial saliva in comparison to that of cp-Ti. Open-circuit potential (E(OC)), potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) were used as electrochemical methods to characterize the corrosion behaviour of Ti20Mo alloy and cp-Ti, respectively. Corrosion current and passive current densities obtained from the polarization curves showed low values indicating a typical passive behaviour for Ti20Mo alloy. The EIS technique enabled us to study the nature of the passive film formed on the binary Ti20Mo alloy at various imposed potentials. The Bode phase spectra obtained for Ti20Mo alloy in artificial saliva exhibited two-time constants at higher potential (0.5 V, 1.0 V), indicating a two-layer structure. According to our experimental measurements, Ti20Mo alloy appears to possess superior corrosion resistance to that of cp-Ti in artificial saliva.


Asunto(s)
Aleaciones/química , Saliva Artificial/farmacología , Aleaciones/farmacocinética , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacocinética , Corrosión , Aleaciones Dentales/química , Espectroscopía Dieléctrica , Electroquímica/métodos , Ensayo de Materiales , Modelos Biológicos , Potenciometría/métodos , Titanio/química , Titanio/farmacocinética
10.
Acta Biomater ; 5(9): 3625-39, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19508903

RESUMEN

Besides other important material features, the corrosion parameters and corrosion products are responsible for limiting the biocompatibility of metallic materials, and can produce undesirable reactions in implant-adjacent and/or more distant tissues. Titanium and some of its alloys are known as being the most biocompatible metallic materials due to their high strength, low modulus, high corrosion resistance in biological media, etc. More recently, Ti-Ta alloys have been developed, and these are expected to become more promising candidates for biomedical and dental applications than commercially pure Ti, Ti-6Al-4V or Ti-6Al-7Nb alloy. The corrosion behavior of the studied Ti-Ta alloys with Ta contents of 30, 40, 50 and 60 wt.% together with the currently used Ti-6Al-7Nb alloy were investigated for dental applications. All alloys were tested by open-circuit potential measurement, linear polarization, potentiodynamic polarization, coulometric zone analysis and electrochemical impedance spectroscopy performed in artificial saliva with different pH, acid lactic and fluoride contents. The passive behavior for all the titanium alloys is observed for artificial saliva, acidified saliva (9.8 gl(-1) lactic acid, pH 2.5) and for fluoridated saliva (1.0 gl(-1) F(-), pH 8). A decrease in corrosion resistance and less protective passive oxide films are observed for all titanium alloys in fluoridated acidified saliva (9.8 gl(-1) lactic acid, 1.0 gl(-1) F(-), pH 2.5) in regard to other electrochemical media used within this work. It is worthy of note that the most important decrease was found for Ti-6Al-7Nb alloy. These conclusions are confirmed by all the electrochemical tests undertaken. However, the results confirm that the corrosion resistance of the studied Ti-Ta alloys in all saliva is better or similar to that of Ti-6Al-7Nb alloy, suggesting that the Ti-Ta alloys have potential for dental applications.


Asunto(s)
Aleaciones Dentales/química , Titanio/química , Aleaciones , Materiales Biocompatibles/química , Corrosión , Técnicas Electroquímicas , Fluoruros/química , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Saliva Artificial/química , Análisis Espectral/métodos , Difracción de Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...