Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
Más filtros










Intervalo de año de publicación
1.
Phys Rev Lett ; 131(22): 222501, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38101385

RESUMEN

We report on the results obtained with the global CUPID-0 background model, which combines the data collected in the two measurement campaigns for a total exposure of 8.82 kg×yr of ^{82}Se. We identify with improved precision the background sources within the 3 MeV energy region, where neutrinoless double ß decay of ^{82}Se and ^{100}Mo is expected, making more solid the foundations for the background budget of the next-generation CUPID experiment. Relying on the excellent data reconstruction, we measure the two-neutrino double ß-decay half-life of ^{82}Se with unprecedented accuracy: T_{1/2}^{2ν}=[8.69±0.05(stat)_{-0.06}^{+0.09}(syst)]×10^{19} yr.

2.
Appl Radiat Isot ; 194: 110704, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36731392

RESUMEN

Core-collapse Supernovae (SNe) are one of the most energetic events in the Universe, during which almost all the star's binding energy is released in the form of neutrinos. These particles are direct probes of the processes occurring in the stellar core and provide unique insights into the gravitational collapse. RES-NOVA will revolutionize how we detect neutrinos from astrophysical sources, by deploying the first ton-scale array of cryogenic detectors made from archaeological lead. Pb offers the highest neutrino interaction cross-section via coherent elastic neutrino-nucleus scattering (CEνNS). Such process will enable RES-NOVA to be equally sensitive to all neutrino flavours. For the first time, we propose the use archaeological Pb as sensitive target material in order to achieve an ultra-low background level in the region of interest (O(1 keV)). All these features make possible the deployment of the first cm-scale neutrino telescope for the investigation of astrophysical sources. In this contribution, we will characterize the radiopurity level and the performance of a small-scale proof-of-principle detector of RES-NOVA, consisting in a PbWO4 crystal made from archaeological-Pb operated as cryogenic detector.

4.
Phys Rev Lett ; 129(11): 111801, 2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36154394

RESUMEN

CUPID-0, an array of Zn^{82}Se cryogenic calorimeters, was the first medium-scale demonstrator of the scintillating bolometers' technology. The first project phase (March 2017-December 2018) allowed the most stringent limit on the neutrinoless double beta decay half-life of the isotope of interest, ^{82}Se, to be set. After a six month long detector upgrade, CUPID-0 began its second and last phase (June 2019-February 2020). In this Letter, we describe the search for neutrinoless double beta decay of ^{82}Se with a total exposure (phase I+II) of 8.82 kg yr^{-1} of isotope. We set a limit on the half-life of ^{82}Se to the ground state of ^{82}Kr of T_{1/2}^{0ν}(^{82}Se)>4.6×10^{24} yr (90% credible interval), corresponding to an effective Majorana neutrino mass m_{ßß}<(263-545) meV. We also set the most stringent lower limits on the neutrinoless decays of ^{82}Se to the 0_{1}^{+}, 2_{1}^{+}, and 2_{2}^{+} excited states of ^{82}Kr, finding 1.8×10^{23} yr, 3.0×10^{23} yr, and 3.2×10^{23} yr (90% credible interval) respectively.

5.
Eur Phys J C Part Fields ; 81(8): 722, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34720725

RESUMEN

Localization and modeling of radioactive contaminations is a challenge that ultra-low background experiments are constantly facing. These are fundamental steps both to extract scientific results and to further reduce the background of the detectors. Here we present an innovative technique based on the analysis of α - α delayed coincidences in 232 Th and 238 U decay chains, developed to investigate the contaminations of the ZnSe crystals in the CUPID-0 experiment. This method allows to disentangle surface and bulk contaminations of the detectors relying on the different probability to tag delayed coincidences as function of the α decay position.

6.
Phys Rev Lett ; 126(17): 171801, 2021 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-33988435

RESUMEN

We measured two-neutrino double beta decay of ^{130}Te using an exposure of 300.7 kg yr accumulated with the CUORE detector. Using a Bayesian analysis to fit simulated spectra to experimental data, it was possible to disentangle all the major background sources and precisely measure the two-neutrino contribution. The half-life is in agreement with past measurements with a strongly reduced uncertainty: T_{1/2}^{2ν}=7.71_{-0.06}^{+0.08}(stat)_{-0.15}^{+0.12}(syst)×10^{20} yr. This measurement is the most precise determination of the ^{130}Te 2νßß decay half-life to date.

7.
Phys Rev Lett ; 124(12): 122501, 2020 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-32281829

RESUMEN

We report new results from the search for neutrinoless double-beta decay in ^{130} Te with the CUORE detector. This search benefits from a fourfold increase in exposure, lower trigger thresholds, and analysis improvements relative to our previous results. We observe a background of (1.38±0.07)×10^{-2} counts/(keV kg yr)) in the 0νßß decay region of interest and, with a total exposure of 372.5 kg yr, we attain a median exclusion sensitivity of 1.7×10^{25} yr. We find no evidence for 0νßß decay and set a 90% credibility interval Bayesian lower limit of 3.2×10^{25} yr on the ^{130} Te half-life for this process. In the hypothesis that 0νßß decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

8.
Phys Rev Lett ; 123(3): 032501, 2019 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-31386478

RESUMEN

CUPID-0 is the first pilot experiment of CUPID, a next-generation project for the measurement of neutrinoless double beta decay (0νDBD) with scintillating bolometers. The detector, consisting of 24 enriched and 2 natural ZnSe crystals, has been taking data at Laboratori Nazionali del Gran Sasso from June 2017 to December 2018, collecting a ^{82}Se exposure of 5.29 kg×yr. In this Letter we present the phase-I results in the search for 0νDBD. We demonstrate that the technology implemented by CUPID-0 allows us to reach the lowest background for calorimetric experiments: (3.5_{-0.9}^{+1.0})×10^{-3} counts/(keV kg yr). Monitoring 3.88×10^{25} ^{82}Se nuclei×yr we reach a 90% credible interval median sensitivity of T_{1/2}^{0ν}>5.0×10^{24} yr and set the most stringent limit on the half-life of ^{82}Se 0νDBD: T_{1/2}^{0ν}>3.5×10^{24} yr (90% credible interval), corresponding to m_{ßß}<(311-638) meV depending on the nuclear matrix element calculations.

9.
Phys Rev Lett ; 123(26): 262501, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31951429

RESUMEN

We report on the measurement of the two-neutrino double-ß decay of ^{82}Se performed for the first time with cryogenic calorimeters, in the framework of the CUPID-0 experiment. With an exposure of 9.95 kg yr of Zn^{82}Se, we determine the two-neutrino double-ß decay half-life of ^{82}Se with an unprecedented precision level, T_{1/2}^{2ν}=[8.60±0.03(stat) _{-0.13}^{+0.19}(syst)]×10^{19} yr. The very high signal-to-background ratio, along with the detailed reconstruction of the background sources allowed us to identify the single state dominance as the underlying mechanism of such a process, demonstrating that the higher state dominance hypothesis is disfavored at the level of 5.5σ.

10.
Phys Rev Lett ; 120(23): 232502, 2018 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-29932707

RESUMEN

We report the result of the search for neutrinoless double beta decay of ^{82}Se obtained with CUPID-0, the first large array of scintillating Zn^{82}Se cryogenic calorimeters implementing particle identification. We observe no signal in a 1.83 kg yr ^{82}Se exposure, and we set the most stringent lower limit on the 0νßß ^{82}Se half-life T_{1/2}^{0ν}>2.4×10^{24} yr (90% credible interval), which corresponds to an effective Majorana neutrino mass m_{ßß}<(376-770) meV depending on the nuclear matrix element calculations. The heat-light readout provides a powerful tool for the rejection of α particles and allows us to suppress the background in the region of interest down to (3.6_{-1.4}^{+1.9})×10^{-3} counts/(keV kg yr), an unprecedented level for this technique.

11.
Eur Phys J C Part Fields ; 78(11): 888, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30881205

RESUMEN

The CUPID-0 experiment searches for double beta decay using cryogenic calorimeters with double (heat and light) read-out. The detector, consisting of 24 ZnSe crystals 95 % enriched in 82 Se and two natural ZnSe crystals, started data-taking in 2017 at Laboratori Nazionali del Gran Sasso. We present the search for the neutrino-less double beta decay of 82 Se into the 0 1 + , 2 1 + and 2 2 + excited states of 82 Kr with an exposure of 5.74 kg · yr (2.24 × 10 25  emitters · yr). We found no evidence of the decays and set the most stringent limits on the widths of these processes: Γ ( 82 Se → 82 Kr 0 1 + )8.55 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 1 + ) < 6.25 × 10 - 24  yr - 1 , Γ ( 82 Se → 82 Kr 2 2 + )8.25 × 10 - 24  yr - 1 (90 % credible interval).

12.
Eur Phys J C Part Fields ; 78(5): 428, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30996670

RESUMEN

The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso, Italy, is the first large array of enriched scintillating cryogenic detectors for the investigation of 82 Se neutrinoless double-beta decay ( 0 ν ß ß ). CUPID-0 aims at measuring a background index in the region of interest (RoI) for 0 ν ß ß at the level of 10 - 3  counts/(keV kg years), the lowest value ever measured using cryogenic detectors. CUPID-0 operates an array of Zn 82 Se scintillating bolometers coupled with bolometric light detectors, with a state of the art technology for background suppression and thorough protocols and procedures for the detector preparation and construction. In this paper, the different phases of the detector design and construction will be presented, from the material selection (for the absorber production) to the new and innovative detector structure. The successful construction of the detector lead to promising preliminary detector performance which is discussed here.

13.
Eur Phys J C Part Fields ; 78(9): 734, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30839752

RESUMEN

The suppression of spurious events in the region of interest for neutrinoless double beta decay will play a major role in next generation experiments. The background of detectors based on the technology of cryogenic calorimeters is expected to be dominated by α particles, that could be disentangled from double beta decay signals by exploiting the difference in the emission of the scintillation light. CUPID-0, an array of enriched Zn 82 Se scintillating calorimeters, is the first large mass demonstrator of this technology. The detector started data-taking in 2017 at the Laboratori Nazionali del Gran Sasso with the aim of proving that dual read-out of light and heat allows for an efficient suppression of the α background. In this paper we describe the software tools we developed for the analysis of scintillating calorimeters and we demonstrate that this technology allows to reach an unprecedented background for cryogenic calorimeters.

14.
Mol Psychiatry ; 23(7): 1597-1605, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29155800

RESUMEN

Epidemiological studies report strong association between mood disorders and tobacco addiction. This high comorbidity requires adequate treatment but the underlying mechanisms are unknown. We demonstrate that nicotine exposure, independent of drug withdrawal effects, increases stress sensitivity, a major risk factor in mood disorders. Nicotine and stress concur to induce long-lasting cellular adaptations within the dopamine (DA) system. This interplay is underpinned by marked remodeling of nicotinic systems, causing increased ventral tegmental area (VTA) DA neurons' activity and stress-related behaviors, such as social aversion. Blocking ß2 or α7 nicotinic acetylcholine receptors (nAChRs) prevents, respectively, the development and the expression of social stress-induced neuroadaptations; conversely, facilitating α7 nAChRs activation specifically in the VTA promotes stress-induced cellular and behavioral maladaptations. Our work unravels a complex nicotine-stress bidirectional interplay and identifies α7 nAChRs as a promising therapeutic target for stress-related psychiatric disorders.


Asunto(s)
Neuronas Dopaminérgicas/efectos de los fármacos , Receptores Nicotínicos/fisiología , Animales , Dopamina/metabolismo , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Neuronas/metabolismo , Nicotina/farmacología , Agonistas Nicotínicos/farmacología , Receptores Nicotínicos/efectos de los fármacos , Receptores Nicotínicos/metabolismo , Estrés Psicológico/metabolismo , Fumar Tabaco/efectos adversos , Fumar Tabaco/psicología , Área Tegmental Ventral/efectos de los fármacos , Receptor Nicotínico de Acetilcolina alfa 7/efectos de los fármacos
15.
Rev Sci Instrum ; 87(5): 054706, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-27250450

RESUMEN

A low noise and high precision linear power supply was designed for use in rare event search experiments with macrobolometers. The circuit accepts at the input a "noisy" dual supply voltage up to ±15 V and gives at the output precise, low noise, and stable voltages that can be set between ±3.75 V and ±12.5 V in eight 1.25 V steps. Particular care in circuit design, component selection, and proper filtering results in a noise spectral density of 50nV/Hz at 1 Hz and 20nV/Hz white when the output is set to ±5 V. This corresponds to 125 nV RMS (0.8 µV peak to peak) between 0.1 Hz and 10 Hz, and 240 nV RMS (1.6 µV peak to peak) between 0.1 Hz and 100 Hz. The power supply rejection ratio (PSRR) of the circuit is 100 dB at low frequency, and larger than 40 dB up to high frequency, thanks to a proper compensation design. Calibration allows to reach a precision in the absolute value of the output voltage of ±70 ppm, or ±350 µV at ±5 V, and to reduce thermal drifts below ±1 ppm/(∘)C in the expected operating range. The maximum peak output current is about 6 A from each output. An original foldback protection scheme was developed that dynamically limits the maximum output current to keep the temperature of the output transistors within their safe operating range. An add-on card based on an ARM Cortex-M3 microcontroller is devoted to the monitoring and control of all circuit functionalities and provides remote communication via CAN bus.

16.
Neuropharmacology ; 108: 324-31, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27157710

RESUMEN

Studies with heterologous expression systems have shown that the α4ß2 nicotinic acetylcholine receptor (nAChR) subtype can exist in two stoichiometries (with two [(α4)2(ß2)3] or three [(α4)3(ß2)2] copies of the α subunit in the receptor pentamer) which have different pharmacological and functional properties and are differently regulated by chronic nicotine treatment. However, the effects of nicotine treatment in vivo on native α4ß2 nAChR stoichiometry are not well known. We investigated in C57BL/6 mice the in vivo effect of 14-day chronic nicotine treatment and subsequent withdrawal, on the subunit expression and ß2/α4 subunit ratio of (3)H-epibatidine labeled α4ß2*-nAChR in total homogenates of cortex and thalamus. We found that in basal conditions the ratio of the ß2/α4 subunit in the cortex and thalamus is different indicating a higher proportion in receptors with (α4)2(ß2)3 subunit stoichiometry in the thalamus. For cortex exposure to chronic nicotine elicited an increase in receptor density measured by (3)H-epibatidine binding, an increase in the α4 and ß2 protein levels, and an increase in ß2/α4 subunit ratio, that indicates an increased proportion of receptors with the (α4)2(ß2)3 stoichiometry. For thalamus we did not find a significant increase in receptor density, α4 and ß2 protein levels, or changes in ß2/α4 subunit ratio. All the changes elicited by chronic nicotine in cortex were transient and returned to basal levels with an average half-life of 2.8 days following nicotine withdrawal. These data suggest that chronic nicotine exposure in vivo favors increased assembly of α4ß2 nAChR containing three ß2 subunits. A greater change in stoichiometry was observed for cortex (which has relatively low basal expression of (α4)2(ß2)3 nAChR) than in thalamus (which has a relatively high basal expression of (α4)2(ß2)3 nAChR).


Asunto(s)
Corteza Cerebral/metabolismo , Nicotina/administración & dosificación , Receptores Nicotínicos/biosíntesis , Tálamo/metabolismo , Regulación hacia Arriba/fisiología , Animales , Corteza Cerebral/efectos de los fármacos , Esquema de Medicación , Infusiones Intravenosas , Masculino , Ratones , Ratones Endogámicos C57BL , Unión Proteica/efectos de los fármacos , Unión Proteica/fisiología , Receptores Nicotínicos/química , Estereoisomerismo , Tálamo/efectos de los fármacos , Regulación hacia Arriba/efectos de los fármacos
17.
Eur Phys J C Part Fields ; 76(7): 364, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-28280442

RESUMEN

The R&D activity performed during the last years proved the potential of ZnSe scintillating bolometers to the search for neutrino-less double beta decay, motivating the realization of the first large-mass experiment based on this technology: CUPID-0. The isotopic enrichment in [Formula: see text]Se, the Zn[Formula: see text]Se crystals growth, as well as the light detectors production have been accomplished, and the experiment is now in construction at Laboratori Nazionali del Gran Sasso (Italy). In this paper we present the results obtained testing the first three Zn[Formula: see text]Se crystals operated as scintillating bolometers, and we prove that their performance in terms of energy resolution, background rejection capability and intrinsic radio-purity complies with the requirements of CUPID-0.

18.
Artículo en Inglés | MEDLINE | ID: mdl-26705394

RESUMEN

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of [Formula: see text]Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched [Formula: see text]Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched [Formula: see text]Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of [Formula: see text]Th, [Formula: see text]U and [Formula: see text]U are respectively: [Formula: see text]61, [Formula: see text]110 and [Formula: see text]74 [Formula: see text]Bq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the [Formula: see text]Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of [Formula: see text]Se to 0[Formula: see text], 2[Formula: see text] and 2[Formula: see text] excited states of [Formula: see text]Kr of 3.4[Formula: see text]10[Formula: see text], 1.3[Formula: see text]10[Formula: see text] and 1.0[Formula: see text]10[Formula: see text] y, respectively, with a 90 % C.L.

19.
Eur Neuropsychopharmacol ; 25(10): 1775-86, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26141510

RESUMEN

Nicotine is the primary addictive substance in tobacco smoke and electronic cigarette (e-cig) vapour. Methodological limitations have made it difficult to compare the role of the nicotine and non-nicotine constituents of tobacco smoke. The aim of this study was to compare the effects of traditional cigarette smoke and e-cig vapour containing the same amount of nicotine in male BALB/c mice exposed to the smoke of 21 cigarettes or e-cig vapour containing 16.8 mg of nicotine delivered by means of a mechanical ventilator for three 30-min sessions/day for seven weeks. One hour after the last session, half of the animals were sacrificed for neurochemical analysis, and the others underwent mecamylamine-precipitated or spontaneous withdrawal for the purposes of behavioural analysis. Chronic intermittent non-contingent, second-hand exposure to cigarette smoke or e-cig vapour led to similar brain cotinine and nicotine levels, similar urine cotinine levels and the similar up-regulation of α4ß2 nicotinic acetylcholine receptors in different brain areas, but had different effects on body weight, food intake, and the signs of mecamylamine-precipitated and spontaneous withdrawal episodic memory and emotional responses. The findings of this study demonstrate for the first time that e-cig vapour induces addiction-related neurochemical, physiological and behavioural alterations. The fact that inhaled cigarette smoke and e-cig vapour have partially different dependence-related effects indicates that compounds other than nicotine contribute to tobacco dependence.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina/efectos adversos , Contaminación por Humo de Tabaco/efectos adversos , Tabaquismo/fisiopatología , Animales , Peso Corporal/efectos de los fármacos , Encéfalo/efectos de los fármacos , Encéfalo/metabolismo , Cotinina/metabolismo , Modelos Animales de Enfermedad , Ingestión de Alimentos/efectos de los fármacos , Emociones/efectos de los fármacos , Masculino , Mecamilamina/farmacología , Memoria a Corto Plazo/efectos de los fármacos , Ratones Endogámicos BALB C , Nicotina/administración & dosificación , Nicotina/metabolismo , Agonistas Nicotínicos/administración & dosificación , Agonistas Nicotínicos/metabolismo , Antagonistas Nicotínicos/farmacología , Receptores Nicotínicos/metabolismo , Respiración Artificial , Memoria Espacial/efectos de los fármacos , Síndrome de Abstinencia a Sustancias/fisiopatología , Síndrome de Abstinencia a Sustancias/psicología , Tabaquismo/etiología
20.
Rev Sci Instrum ; 86(12): 124703, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26724052

RESUMEN

In this work, we present the first part of the power supply system for the CUORE and LUCIFER arrays of bolometric detectors. For CUORE, it consists of AC/DC commercial power supplies (0-60 V output) followed by custom DC/DC modules (48 V input, ±5 V to ±13.5 V outputs). Each module has 3 floating and independently configurable output voltages. In LUCIFER, the AC/DC + DC/DC stages are combined into a commercial medium-power AC/DC source. At the outputs of both setups, we introduced filters with the aim of lowering the noise and to protect the following stages from high voltage spikes that can be generated by the energy stored in the cables after the release of accidental short circuits. Output noise is very low, as required: in the 100 MHz bandwidth the RMS level is about 37 µV(RMS) (CUORE setup) and 90 µV(RMS) (LUCIFER setup) at a load of 7 A, with a negligible dependence on the load current. Even more importantly, high frequency switching disturbances are almost completely suppressed. The efficiency of both systems is above 85%. Both systems are completely programmable and monitored via CAN bus (optically coupled).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...