Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Radiography (Lond) ; 24(4): e85-e90, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30292518

RESUMEN

INTRODUCTION: Multi-slice computed tomography (MSCT) is an accurate tool for the assessment of left ventricular ejection fraction (LVEF). However, in order to reduce radiation dose, prospective acquisition protocols are currently used, in which the end-systole and end-diastole are not scanned. Our aim was to study the accuracy of the assessment of LVEF using fixed late-systolic and mid-diastolic cardiac phases compared with echocardiography. METHODS: MSCT-derived LVEF was measured with off-line commercially available software packages, and compared with echocardiography-derived LVEF using the Simpson's method. LVEF was categorized as normal vs. abnormal (50% cut-off) and was also analyzed as a quantitative parameter. Bland-Altman plots and Pearson correlations were used for inter-technique comparisons. RESULTS: 58 patients were included. The sensitivity and specificity of fixed-phase MSCT when compared with echocardiography for detection of LVEF ≤50% was 79% (95% CI = 65-89%) and 43% (10-82%). Misclassification was associated with older age (68 ± 12 vs. 54 ± 13 years, p < 0.01), faster heart rate (79 ± 14 vs. 68 ± 10 bpm, p = 0.01), and LV hypertrophy (86% vs. 52%, p = 0.03). The quantitative comparison revealed no correlation (r = 0.095, p = 0.478) and a significantly different LVEF (median[IQR], 57.0[50.5-63.1]% vs. 61.0[57.3-64.3]%, p = 0.03). The observed bias between the two methods was -3.7% with broad limits of agreement (±25.5%). CONCLUSIONS: Fixed-phase MSCT assessment using late-systole and mid-diastole agreed in defining normal and abnormal LVEF in 76% of patients when compared with echocardiography. Quantitation of LVEF by this method yielded significantly lower values of LVEF and showed no correlation. Thus, accurate quantitation of LVEF by MSCT requires the acquisition of end-systolic and end-diastolic phases.


Asunto(s)
Diástole/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Volumen Sistólico/fisiología , Sístole/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada Multidetector/métodos , Estudios Retrospectivos
2.
Ultraschall Med ; 34(1): 51-7, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22872379

RESUMEN

PURPOSE: Transtemporal sonothrombolysis is a tool for a more effective treatment in acute stroke patients. However, some reports revealed side effects, which might be potentially connected to temperature elevation. To gain better insight into cerebral temperature changes during transtemporal sonication, diagnostic and therapeutic ultrasound (US) applications were evaluated using an anthropomorphic skull model. MATERIALS AND METHODS: The impact of diagnostic (PW-Doppler, 1.8-MHz, 0.11 W/cm², TIC 1.2) and therapeutic (1-MHz and 3-MHz, 0.07 - 0.71 W/cm², continuous and pulsed mode) US application on temperature changes was evaluated at the level of muscle/temporal bone (TB), TB/brain, brain and at the middle cerebral artery (MCA) using 4 miniature thermocouples along the US beam. Sonication lasted 120 minutes. RESULTS: Diagnostic ultrasound revealed a maximum temperature increase of 1.45°/0.60°/0.39°/0.41°C (muscle/TB, TB/brain, brain, MCA) after 120 minutes. Therapeutic-1-MHz ultrasound raised temperature by 4.33°/2.02°/1.05 °C/0.81°C (pulsed 1:20) and by 10.38°/4.95°/2.43°/2.08°C (pulsed 1:5) over 120 minutes. Therapeutic-3-MHz US raised temperature by 4.89°/2.56°/1.24/1.25°C (pulsed 1:20) and by 14.77°/6.59°/3.56°/2.86°C (pulsed 1:5) over 120 minutes, respectively. Continuous application of therapeutic US (1-MHz and 3-MHz) led to a temperature increase of 13.86°/3.63°/1.66°/1.48°C and 17.09°/4.28°/1.38/0.99°C within 3 minutes. CONCLUSION: Diagnostic PW-Doppler showed only a moderate temperature increase and can be considered as safe. Therapeutic sonication is very powerful in delivering energy so that even pulsed application modes resulted in significant and potentially harmful temperature increases.


Asunto(s)
Regulación de la Temperatura Corporal/fisiología , Encéfalo/fisiopatología , Infarto Cerebral/diagnóstico por imagen , Infarto Cerebral/terapia , Calefacción/efectos adversos , Trombosis Intracraneal/diagnóstico por imagen , Trombosis Intracraneal/terapia , Trombolisis Mecánica/efectos adversos , Trombolisis Mecánica/métodos , Fantasmas de Imagen , Terapia por Ultrasonido/efectos adversos , Terapia por Ultrasonido/métodos , Ultrasonografía Doppler Transcraneal/efectos adversos , Ultrasonografía Doppler Transcraneal/métodos , Humanos , Técnicas In Vitro , Trombolisis Mecánica/instrumentación , Transductores , Terapia por Ultrasonido/instrumentación , Ultrasonografía Doppler Transcraneal/instrumentación
4.
Ultraschall Med ; 33(7): E313-E320, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22744443

RESUMEN

PURPOSE: Exposure to diagnostic ultrasound (US) can significantly heat biological tissue although conventional routine examinations are regarded as safe. The risk of unwanted thermal effects increases with a high absorption coefficient and extended insonation time. Certain applications of transcranial diagnostic US (TC-US) require prolonged exposure. An anthropomorphic skull model (ASM) was developed to evaluate thermal effects induced by TC-US of different modalities. The objective was to determine whether prolonged continuous TC-US application results in potentially harmful temperature increases. MATERIALS AND METHODS: The ASM consists of a human skull with tissue mimicking material and exhibits acoustic and anatomical characteristics of the human skull and brain. Experiments are performed with a diagnostic US device testing four different US modalities: Duplex PW (pulsed wave) Doppler, PW Doppler, color flow Doppler and B-mode. Temperature changes are recorded during 180 minutes of insonation. RESULTS: All measurements revealed significant temperature increases during insonation independent of the US modality. The maximum temperature elevation of + 5.25° C (p < 0.001) was observed on the surface of the skull exposed to duplex PW Doppler. At the bone-brain border a maximum temperature increae of + 2.01 °C (p < 0.001) was noted. Temperature increases within the brain were < 1.23 °C (p = 0.001). The highest values were registered using the duplex PW Doppler modality. CONCLUSION: TC-US induces significant local heating effects in an ASM. An application duration that extends routine clinical periods causes potentially harmful heating especially in tissue close to bone. TC-US elevates the temperature in the brain mimicking tissue but is not capable of producing harmful temperature increases during routine examinations. However, the risk of thermal injury in brain tissue increases significantly after an exposure time of > 2 hours.


Asunto(s)
Temperatura Corporal , Ecoencefalografía/efectos adversos , Calor , Fantasmas de Imagen , Ultrasonografía Doppler en Color/efectos adversos , Ultrasonografía Doppler Dúplex/efectos adversos , Ultrasonografía Doppler Transcraneal/efectos adversos , Daño Encefálico Crónico/etiología , Ecoencefalografía/métodos , Humanos , Riesgo , Factores de Tiempo , Ultrasonografía Doppler en Color/métodos , Ultrasonografía Doppler Dúplex/métodos , Ultrasonografía Doppler Transcraneal/métodos
5.
Wien Klin Wochenschr ; 124(9-10): 340-7, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22576960

RESUMEN

In any type of invasive surgery, the patient's individual risk of thromboembolism has to be weighed against the risk of bleeding. Based on various everyday situations in clinical routine, the purpose of the present expert recommendations is to provide appropriate perioperative and periinterventional management for patients with atrial fibrillation undergoing long-term treatment with the thrombin inhibitor dabigatran. As we currently have no routine laboratory test to measure therapeutic levels of the substance or the risk of bleeding, general measures such as a standardized documentation of the patient's history, a sufficient time interval between the last preoperative dose and the procedure, and careful control of local hemostasis should be given special attention.


Asunto(s)
Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Bencimidazoles/efectos adversos , Bencimidazoles/uso terapéutico , Hemorragia Posoperatoria/inducido químicamente , Hemorragia Posoperatoria/prevención & control , Premedicación/normas , beta-Alanina/análogos & derivados , Austria , Dabigatrán , Femenino , Humanos , Masculino , Atención Perioperativa/métodos , Atención Perioperativa/normas , Guías de Práctica Clínica como Asunto , Premedicación/métodos , beta-Alanina/efectos adversos , beta-Alanina/uso terapéutico
6.
J Thromb Haemost ; 3(2): 233-9, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15670026

RESUMEN

BACKGROUND: The plasmin activation system is involved in the development of restenosis after percutaneous coronary interventions (PCI). Conflicting data exist concerning the role of plasminogen activator inhibitor-1 (PAI-1) and its predictive value for restenosis. OBJECTIVES: To evaluate the fibrinolytic response to injury after PCI with or without stent implantation on different antithrombotic medications and its relation to late restenosis. PATIENTS AND METHODS: Eighty consecutive patients with successful PCI without (balloon only; n = 37) or with stent implantation (stent; n = 43) on different antithrombotic regimes (balloon only, aspirin; stent, aspirin/coumadin/dipyridamole vs. aspirin/ticlopidine). Blood samples were taken at baseline and up to 7 days after PCI and PAI-1 active antigen and tissue plasminogen activator (t-PA) antigen were determined. Restenosis was angiographically determined after 6 months. RESULTS: PCI increased both t-PA and PAI-1 levels (P < 0.001), with a significant prolonged and pronounced increase in stent vs. balloon-only patients (P < 0.05). Restenosis (stent 26%; balloon 38%) was significantly correlated to an attenuated PAI-1 increase after 24 h in the ticlopidine group (P = 0.007; restenosis, relative Delta PAI-1 + 50 +/- 28%; non-restenosis, + 139 +/- 50%), but not in the coumadin group. In the balloon-only group late restenosis (ISR) was associated with a trend for an augmented PAI-1 increase after 24 h. CONCLUSIONS: Coronary stent implantation significantly increases t-PA and PAI-1 plasma levels up to 1 week compared with balloon angioplasty alone. ISR in ticlopidine-treated patients was associated with an attenuated early PAI-1 active antigen increase. A less than 50% increase 24 h after stent implantation under ticlopidine treatment may identify patients at risk for the development of ISR.


Asunto(s)
Reestenosis Coronaria/diagnóstico , Inhibidor 1 de Activador Plasminogénico/sangre , Valor Predictivo de las Pruebas , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Aspirina/uso terapéutico , Terapia Combinada/efectos adversos , Terapia Combinada/métodos , Reestenosis Coronaria/sangre , Reestenosis Coronaria/etiología , Femenino , Fibrinólisis , Fibrinolíticos/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Inhibidor 1 de Activador Plasminogénico/fisiología , Piridinas/uso terapéutico , Estudios Retrospectivos , Stents/efectos adversos , Ticlopidina/uso terapéutico , Activador de Tejido Plasminógeno/sangre
7.
Cardiovasc Intervent Radiol ; 26(2): 154-7, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-12638038

RESUMEN

This study was performed to evaluate the outcome of percutaneous revascularization in "edge restenoses" developing after radioactive stent implantation in de novo and in-stent lesions. Twenty-one consecutive patients undergoing target lesion revascularization (TLR) at any follow-up after phosphorus-32 radioactive stent implantation were included in this study. We assessed the incidence of death, myocardial infarction, repeated TLR and recurrent angina over the following 18 months. After 6 months, TLR rate was 28.6%, and no stent thromboses, deaths or Q-wave myocardial infarctions occurred. Among the patients with TLR there were significantly more subjects who had received a radioactive stent in a previous in-stent restenosis (66.7% vs. 0% in patients without second restenosis; P <0.001), or who had received two radioactive stents (83.3% vs. 33.3%; P = 0.038). After 18 months, TLR rate was 33.3%, and two patients (9.5%) had died. Restenosis after intravascular radiotherapy can be safely treated by percutaneous interventional techniques, yielding an acceptable clinical result within 18 months.


Asunto(s)
Reestenosis Coronaria/etiología , Radiación , Stents , Adulto , Anciano , Angioplastia Coronaria con Balón , Arterias/patología , Arterias/efectos de la radiación , Arterias/cirugía , Austria , Implantación de Prótesis Vascular , Materiales Biocompatibles Revestidos/efectos adversos , Materiales Biocompatibles Revestidos/uso terapéutico , Reestenosis Coronaria/terapia , Vasos Coronarios/patología , Vasos Coronarios/efectos de la radiación , Vasos Coronarios/cirugía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Fósforo/efectos adversos , Radioisótopos de Fósforo/uso terapéutico , Radiofármacos/efectos adversos , Radiofármacos/uso terapéutico , Reoperación , Resultado del Tratamiento
8.
Wien Klin Wochenschr ; 113(19): 727-30, 2001 Oct 15.
Artículo en Alemán | MEDLINE | ID: mdl-11715750

RESUMEN

BACKGROUND AND AIM: Atherosclerosis and its clinical sequelae are responsible for the highest death rate in industrialized countries. Seroepidemiological, pathological and immunohistochemical studies have suggested a relation between Chlamydia pneumoniae infection and the development of coronary sclerosis. Aim of this study was to investigate the frequency distribution of Chlamydia pneumoniae antibody titers in patients with different clinical stages of coronary artery disease (CAD) and patients without CAD as well as a possible age dependence of antibody titers within the study groups. For this purpose, 522 consecutive patients of a cardiology ward were investigated, over a period of 10 months, for the presence of Chlamydia pneumoniae antibodies (IgG, IgA, IgM) using specific ELISA's. In general, there was no difference in the frequency of positive Chlamydia antibody titers between CAD patients and the control group. Only in the subgroup of unstable CAD-patients < 50 years a tendency of increased antibody titers was present. Patients with stable angina, unstable angina, or acute myocardial infarction exhibited no significant differences in the rate of infection between the different age groups (p < 0.117). In contrast, there was a significant increase in positive Chlamydia pneumoniae antibodies with increasing age in the control group (p = 0.002). The relatively high incidence of positive Chlamydia pneumoniae antibody titers in young CAD patients, which is associated with a loss of age-dependent increase of the antibody titers in the CAD group, might indicate a specific role of Chlamydia pneumoniae infections for the manifestation of premature CAD (before the age of 50). Due to the increased rate of Chlamydia pneumoniae infections with increasing age, the determination of Chlamydia pneumoniae antibody titers does not allow reliable conclusions on the infectious pathogenesis of CAD. Furthermore, our unability to demonstrate differences in antibody titers between CAD patients with stable angina, unstable angina, and acute myocardial infarction suggests that acute Chlamydia pneumoniae infections are not responsible for the development of acute coronary syndromes.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Chlamydophila pneumoniae/inmunología , Enfermedad Coronaria/inmunología , Factores de Edad , Anciano , Angina de Pecho/etiología , Angina de Pecho/inmunología , Angina Inestable/etiología , Angina Inestable/inmunología , Distribución de Chi-Cuadrado , Infecciones por Chlamydophila/complicaciones , Enfermedad Coronaria/etiología , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/inmunología
9.
Clin Cardiol ; 24(9): 630-2, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11558847

RESUMEN

We present the case of a 67-year-old man in whom a guidewire broke at rotablation of the right coronary artery, creating an iatrogenic aneurysmal arteriovenous fistula to the coronary sinus. Successful Doppler wire-guided fistula occlusion by percutaneous coil embolization lead to normalization of coronary blood flow and relief of the patient's symptoms. Myocardial ischemia in this patient may have been due to a steal phenomenon caused by coronary artery fistulae, as suggested by blood flow velocity data obtained before and after fistula occlusion.


Asunto(s)
Arterias/anomalías , Fístula Arteriovenosa/complicaciones , Fístula Arteriovenosa/patología , Vasos Coronarios/patología , Enfermedad Iatrogénica , Síndrome del Robo de la Subclavia/etiología , Anciano , Arterias/diagnóstico por imagen , Procedimientos Quirúrgicos Cardiovasculares/efectos adversos , Procedimientos Quirúrgicos Cardiovasculares/instrumentación , Vasos Coronarios/diagnóstico por imagen , Ecocardiografía Doppler , Seguridad de Equipos , Humanos , Masculino
10.
Thromb Res ; 103(2): 103-7, 2001 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-11457467

RESUMEN

UNLABELLED: The 4G/5G polymorphism of the plasminogen activator inhibitor type I (PAI-I) gene is involved in coronary artery disease (CAD), with the highest risk in 4G/4G homozygotes. The role of PAI-I polymorphism in patients suffering from CAD and history of sudden cardiac death (SCD) has not been addressed yet. We studied the frequency distribution of the PAI-I gene to test the hypothesis that the 4G/4G genotype favors myocardial ischemia and, even in the absence of acute infarction, promotes SCD in patients with CAD. METHODS: The PAI-I 4G/5G genotypes and PAI-I antigen plasma levels were determined in 97 patients with CAD and a history of SCD treated with an implantable cardioverter defibrillator (ICD) (defibrillator group) comparing to 113 patients with CAD but no history of SCD (control group). RESULTS: The defibrillator group consisted of significantly more 4G/4G homozygotes and higher PAI-I levels than the control group (44% vs. 24%, 173+/-41 vs. 144+/-49 ng/ml; P<.01). The carriers of 4G allele had a significantly higher risk for SCD (odds ratio (OR) 1.9) with the highest risk in the 4G/4G genotype (OR 3.6, P<.01). CONCLUSION: These results suggest that the PAI-I 4G/4G genotype is associated with SCD in patients suffering from CAD.


Asunto(s)
Enfermedad Coronaria/complicaciones , Muerte Súbita Cardíaca/epidemiología , Inhibidor 1 de Activador Plasminogénico/genética , Polimorfismo Genético , Regiones Promotoras Genéticas/genética , Anciano , Alelos , Estudios de Casos y Controles , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/estadística & datos numéricos , Electrocardiografía , Femenino , Imagen de Acumulación Sanguínea de Compuerta , Frecuencia de los Genes , Predisposición Genética a la Enfermedad , Genotipo , Humanos , Funciones de Verosimilitud , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Análisis de Regresión , Factores de Riesgo , Análisis de Supervivencia , Taquicardia Ventricular/complicaciones , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/complicaciones , Fibrilación Ventricular/prevención & control
11.
Radiology ; 220(1): 142-4, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11425986

RESUMEN

Postmortem angiography and histologic analysis of a fatal coronary thrombosis 4 months after implantation of a radioactive stent are described. Histologic findings suggested incomplete re-endothelialization in the segment with the stent. Ionizing radiation may delay re-endothelialization after revascularization, thus maintaining the thrombogenicity of the irradiated vessel segment. Thus, prolonged antiplatelet therapy should be considered after intravascular radiation therapy.


Asunto(s)
Angiografía Coronaria/métodos , Vasos Coronarios/patología , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Radioisótopos de Fósforo/efectos adversos , Stents/efectos adversos , Anciano , Autopsia , Biopsia con Aguja , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/métodos , Resultado Fatal , Humanos , Masculino , Radioisótopos de Fósforo/uso terapéutico , Radioisótopos , Recurrencia , Medición de Riesgo , Sensibilidad y Especificidad
12.
Radiother Oncol ; 59(3): 329-37, 2001 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-11369076

RESUMEN

BACKGROUND AND PURPOSE: Radioactive stents are under investigation for reduction of coronary restenosis. However, the actual dose delivered to specific parts of the coronary artery wall based on the individual vessel anatomy has not been determined so far. Dose-volume histograms (DVHs) permit an estimation of the actual dose absorbed by the target volume. We present a method to calculate DVHs based on intravascular ultrasound (IVUS) measurements to determine the dose distribution within the vessel wall. MATERIALS AND METHODS: Ten patients were studied by intravascular ultrasound after radioactive stenting (BX Stent, P-32, 15-mm length) to obtain tomographic cross-sections of the treated segments. We developed a computer algorithm using the actual dose distribution of the stent to calculate differential and cumulative DVHs. The minimal target dose, the mean target dose, the minimal doses delivered to 10 and 90% of the adventitia (DV10, DV90), and the percentage of volume receiving a reference dose at 0.5 mm from the stent surface cumulated over 28 days were derived from the DVH plots. Results were expressed as mean+/-SD. RESULTS: The mean activity of the stents was 438+/-140 kBq at implantation. The mean reference dose was 111+/-35 Gy, whereas the calculated mean target dose within the adventitia along the stent was 68+/-20 Gy. On average, DV90 and DV10 were 33+/-9 Gy and 117+/-41 Gy, respectively. Expanding the target volume to include 2.5-mm-long segments at the proximal and distal ends of the stent, the calculated mean target dose decreased to 55+/-17 Gy, and DV 90 and DV 10 were 6.4+/-2.4 Gy and 107+/-36 Gy, respectively. CONCLUSIONS: The assessment of DVHs seems in principle to be a valuable tool for both prospective and retrospective analysis of dose-distribution of radioactive stents. It may provide the basis to adapt treatment planning in coronary brachytherapy to the common standards of radiotherapy.


Asunto(s)
Ultrasonografía Intervencional/métodos , Anciano , Algoritmos , Enfermedad Coronaria/diagnóstico por imagen , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Stents
13.
Eur Heart J ; 21(14): 1152-8, 2000 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10924298

RESUMEN

AIMS: This study was designed to investigate the role of inflammation on the occurrence of angiographic restenosis 6 months after coronary stent implantation and the influence of different kinds of antithrombotic and antiplatelet strategies on inflammation. METHODS AND RESULTS: In an open randomized trial, 40 consecutive patients were treated with aspirin (100 mg. day(-1)) and either ticlopidine (2x250 mg. day(-1)) (n=17), or phenprocoumon (INR 2.0-3.0) and dipyridamole (3x160 mg. day(-1)) (n=23) after successful elective coronary stent implantation. Plasma levels of C-reactive protein were determined one day before stent implantation and serially thereafter twice daily up to 120 h. C-reactive protein plasma levels increased significantly (P<0.0001) after stent implantation. Phenprocoumon and dipyridamole or ticlopidine had no effect on C-reactive protein plasma levels (P=0.51) or the occurrence of angiographic restenosis (P=0.48). C-reactive protein plasma levels were significantly higher in patients with lesion type C compared to types A or B (P=0.035), respectively. C-reactive protein plasma levels were significantly higher and mean shoulder levels occurred 48 h later in patients with restenosis compared to patients without restenosis after 6 months (P=0.038). CONCLUSIONS: Elevated C-reactive protein plasma levels still persisting 96 h after stent implantation might reflect a prolonged inflammatory reaction to coronary stent implantation which might causally be involved in pathophysiological mechanisms leading to restenosis.


Asunto(s)
Angioplastia Coronaria con Balón , Proteína C-Reactiva/metabolismo , Enfermedad Coronaria/terapia , Oclusión de Injerto Vascular/sangre , Stents , Anticoagulantes/uso terapéutico , Aspirina/uso terapéutico , Biomarcadores/sangre , Angiografía Coronaria , Enfermedad Coronaria/sangre , Enfermedad Coronaria/diagnóstico por imagen , Dipiridamol/uso terapéutico , Quimioterapia Combinada , Femenino , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Fenprocumón/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico , Pronóstico , Ticlopidina/uso terapéutico
16.
Int J Radiat Oncol Biol Phys ; 46(1): 249-55, 2000 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-10656399

RESUMEN

PURPOSE: Post-dilatation irradiation of the vessel wall is currently under investigation for prevention of restenosis after balloon dilatation. For the irradiation, special sources were designed for animal experiments which would give equivalent irradiation conditions and doses to the vessel wall that would later be employed for human application. METHODS AND MATERIALS: For the planned irradiations, a specially designed yttrium-wire of 0.45-mm diameter coated with a thin shrink tube to prevent contamination was deployed. Several leakage tests applied before and after application proved that the irradiation source was leakproof. Dosimetry was performed by using 0.1-mm-thick thermoluminescent dosimeters (TLD-100) calibrated against a primary standard. A shielding transport and application container was designed to facilitate the handling of the source during use, while reducing exposure of the medical personnel. RESULTS: The designed source proves to be flexible for the insertion into proximal coronary vessels, and positioning at the site of stenosis. It provides an optimum protection of the animal and requires little radiation protection efforts on behalf of the medical staff. Dosimetric calculations and measurements showed that a centering of the source inside the vessel could be achieved with a maximum deviation of 50% between maximum and average dose levels. CONCLUSION: A yttrium-90 beta brachytherapy source was designed which provides high flexibility within proximal coronary arteries, ensures an adequate centering inside the artery, and provides irradiation conditions to the vessel wall of the experimental animal comparable to the application inside a human artery.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Braquiterapia/instrumentación , Enfermedad Coronaria/prevención & control , Enfermedad Coronaria/terapia , Radioisótopos de Itrio/administración & dosificación , Animales , Partículas beta , Braquiterapia/métodos , Vasos Coronarios/anatomía & histología , Vasos Coronarios/efectos de la radiación , Humanos , Dosis de Radiación , Protección Radiológica , Radiometría/métodos
17.
Acta Med Austriaca ; 26(2): 70-82, 1999.
Artículo en Alemán | MEDLINE | ID: mdl-10478281

RESUMEN

This article discusses recent developments in the field of acute coronary syndromes including pathophysiological mechanisms as well as therapeutic strategies. A plaque disruption is caused by different stimuli in a plaque prone to rupture, i.e. a plaque with a lipid-rich core and high local concentration of inflammatory cells (T-cells, monocytes/macrophages, mast cells). These cells are capable of producing matrix degradation products and can reduce stability of a plaque. Thrombus formation, based on platelet activation and aggregation as well as fibrin formation, is the main consequence of plaque disruption. Depending on the degree of thrombus formation occlusion is followed clinically by unstable angina (subtotal occlusion) or by acute myocardial infarction (total occlusion). Accompanying vasoconstriction may further aggravate the situation. Principles of therapy are thrombus dissolution as well as prevention of new thrombus formation: main goals of thrombolytic therapy in acute myocardial infarction are a prompt (less than 3 hours), complete, and sustained (prevention of early thrombotic reocclusion) reperfusion.


Asunto(s)
Enfermedad Coronaria/fisiopatología , Enfermedad Coronaria/terapia , Trombosis Coronaria/fisiopatología , Trombosis Coronaria/terapia , Enfermedad Aguda , Humanos , Síndrome , Terapia Trombolítica , Vasoconstricción
18.
Thromb Haemost ; 81(4): 522-6, 1999 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10235432

RESUMEN

BACKGROUND: The main long-term complication of percutaneous transluminal coronary angioplasty (PTCA) is restenosis that occurs in 30-50 percent of all primary successful cases. The purpose of this study was to evaluate the predictive value of changes in plasminogen activator inhibitor-1 (PAI-1) activity and of thallium dipyridamole perfusion imaging performed 3 months after successful angioplasty. All patients were asymptomatic at evaluation. The results of these two noninvasive tests were compared with the angiographic outcome after 6 months. METHOD AND PATIENTS: Twenty-five patients were included in this prospective study. All patients had single vessel disease, successful angioplasty and were free of clinical symptoms 3 months after angioplasty that would suggest late restenosis. In 12/25 patients (48%) angiographic restenosis (percent diameter stenosis >50%) was determined by follow-up angiography 6 months after angioplasty. PAI-1 plasma activity was determined by a functional titration assay and increase or decrease of PAI-1 plasma activity was evaluated between values obtained before and 3 months after angioplasty. In 7/25 (28%) patients PAI-1 plasma activity increased to more than 90% of pre-angioplasty values. This increase correlated with angiographic restenosis evaluated 6 months after angioplasty (sensitivity 42%, specificity 85%, positive predictive value 71%, and negative predictive value 61%). T1-201-perfusion imaging was performed 3 months after angioplasty. This test was indicative for subsequent restenosis in 5/25 patients (sensitivity 33%, specificity 100%, positive predictive value 62%, and negative predictive value 100%). In 10/25 (40%) patients at least one of the two non-invasive tests performed 3 months after angioplasty predicted angiographic restenosis at 6 months: the combined use of PAI-1 and T1-201-perfusion imaging resulted in increased sensitivity (67%) and high specificity (85%). CONCLUSION: The results of this study indicate that an increase of PAI-1 plasma activity may improve the predictive value for restenosis of T1-201-scintigraphy performed 3 months after angioplasty even in asymptomatic patients.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/terapia , Corazón/diagnóstico por imagen , Inhibidor 1 de Activador Plasminogénico/sangre , Radioisótopos de Talio , Enfermedad Coronaria/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cintigrafía , Recurrencia , Factores de Riesgo
19.
Cardiovasc Res ; 43(4): 879-83, 1999 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10615414

RESUMEN

OBJECTIVES: It has been reported that patients carrying the angiotensin-converting enzyme (ACE) deletion DD genotype with the angiotensin II type 1 (AT1) C allele are at increased risk for myocardial infarction. The frequency distribution of the ACE and AT1 receptor gene polymorphism and their possible relation regarding malignant ventricular arrhythmias in patients with coronary artery disease (CAD) and left ventricular dysfunction was determined. METHODS: The ACE I/D and AT1 A/C polymorphisms (using polymerase chain reaction) in 100 Caucasian patients suffering from CAD with a history of malignant ventricular arrhythmias treated with an implantable cardioverter defibrillator (ICD group) was compared to 127 age-matched Caucasian patients with CAD and no history of malignant ventricular arrhythmias (control group). All patients had reduced left ventricular ejection fraction of < 40% and were comparable regarding sex distribution, body mass index, ACE-inhibitor treatment, lipid status and duration of CAD. RESULTS: The prevalence of DD/CC in the ICD group was significantly higher (19% versus 10%, p < 0.0001). The risk for malignant ventricular arrhythmias was associated with the combination of ACE D and AT1 C alleles (odds-ratio: 2.4, 95% confidence interval 1.41 to 3.94, p < 0.001). The distribution of ACE and AT1 genotypes was not different between the two group. CONCLUSIONS: Patients with coronary artery disease and left ventricular dysfunction carrying ACE D and AT1 C alleles are at increased risk for development of malignant ventricular arrhythmias. Because of available pharmacological inhibitors, these results may have clinical implications for the prevention of sudden cardiac death.


Asunto(s)
Arritmias Cardíacas/genética , Enfermedad Coronaria/genética , Peptidil-Dipeptidasa A/farmacología , Polimorfismo Genético , Receptores de Angiotensina/genética , Anciano , Análisis de Varianza , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reacción en Cadena de la Polimerasa , Receptor de Angiotensina Tipo 1 , Receptor de Angiotensina Tipo 2 , Factores de Riesgo , Disfunción Ventricular Izquierda/genética
20.
Metabolism ; 47(9): 1058-64, 1998 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-9751233

RESUMEN

This study was performed to investigate the effect of low-density lipoprotein (LDL) immunoapheresis on lipoprotein(a) [Lp(a)] reduction in patients with heterozygous and homozygous familial hyperlipidemia (N=16) and insufficient response to lipid-lowering agents. By desorption of approximately 5,700+/-500 mL of plasma, a mean reduction in total cholesterol of 62% (P < .001) and in LDL-cholesterol of 70% (P < .001) was achieved. Lp(a), which was elevated at study entry in seven of these patients (82.1+/-34.3 mg/dL; range, 48 to 148 mg/dL), was reduced during the initial LDL-apheresis procedure by 74.8%+/-14.1% (P < .001). Long-term apheresis treatment performed at weekly intervals resulted in an mean reduction in Lp(a) pretreatment values to 39.1+/-28.5 mg/dL (-54%; P < .001). Desorbed Lp(a) was measured at the waste of the columns for 31 apheresis treatments. Lp(a) concentration of the column waste was higher in patients with elevated serum Lp(a) pretreatment values as compared with those with Lp(a) serum values within the normal range (elevated Lp(a), 1,420+/-380 mg; without elevated Lp(a), 235+/-190 mg; P < .001). The rate of return of Lp(a) following apheresis treatment scheduled at weekly intervals was comparable to that of LDL-cholesterol.


Asunto(s)
Eliminación de Componentes Sanguíneos , Hiperlipidemias/terapia , Lipoproteína(a)/sangre , Lipoproteínas LDL/aislamiento & purificación , Adolescente , Adulto , Anciano , Angiografía Coronaria , Enfermedad Coronaria/etiología , Femenino , Humanos , Inhibidores de Hidroximetilglutaril-CoA Reductasas/uso terapéutico , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...