Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Viruses ; 14(9)2022 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-36146735

RESUMEN

Immunocompromised individuals generally fail to mount efficacious immune humoral responses following vaccination. The emergence of SARS-CoV-2 variants of concern has raised the question as to whether levels of anti-spike protein antibodies achieved after two or three doses of the vaccine efficiently protect against breakthrough infection in the context of immune suppression. We used a fluorescence-based neutralization assay to test the sensitivity of SARS-CoV-2 variants (ancestral variant, Beta, Delta, and Omicron BA.1) to the neutralizing response induced by vaccination in highly immunosuppressed allogeneic HSCT recipients, tested after two and three doses of the BNT162b2 vaccine. We show that neutralizing antibody responses to the Beta and Delta variants in most immunocompromised HSCT recipients increased after three vaccine doses up to values similar to those observed in twice-vaccinated healthy adults and were significantly lower against Omicron BA.1. Overall, neutralization titers correlated with the amount of anti-S-RBD antibodies measured by means of enzyme immunoassay, indicating that commercially available assays can be used to quantify the anti-S-RBD antibody response as a reliable surrogate marker of humoral immune protection in both immunocompetent and immunocompromised individuals. Our findings support the recommendation of additional early vaccine doses as a booster of humoral neutralizing activity against emerging variants, in HSCT immunocompromised patients. In the context of Omicron circulation, it further emphasizes the need for reinforcement of preventive measures including the administration of monoclonal antibodies in this high-risk population.


Asunto(s)
COVID-19 , Trasplante de Células Madre Hematopoyéticas , Vacunas Virales , Adulto , Anticuerpos Monoclonales , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Formación de Anticuerpos , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , SARS-CoV-2
2.
Microbiol Spectr ; 10(4): e0115722, 2022 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-35862982

RESUMEN

Large-scale head-to-head assessment of the performance of lateral-flow tests (LFTs) for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigen is required in the context of the continuous emergence of new viral variants. The aim of this study was to evaluate the performance of 22 rapid LFTs for the detection of SARS-CoV-2 antigens. The clinical performance of 22 LFTs was evaluated in 1,157 samples collected in the Greater Paris area. The 8 best-performing LFTs were further assessed for their ability to detect 4 variants of concern (VOC), including the alpha, beta, delta, and omicron (BA.1) variants. The specificity of SARS-CoV-2 LFTs was generally high (100% for 15 of them) but was insufficient (<75%) for 3 tests. Sensitivity of the LFTs varied from 30.0% to 79.7% compared to nucleic acid amplification testing (NAAT). Using a cycle threshold (CT) cutoff of ≤25, sensitivity of the assays ranged from 59.7% to 100%. The 8 best-performing assays had a sensitivity of ≥80% for the detection of the 4 VOC when the CT was ≤25. Falsely negative SARS-CoV-2 antigen LFT results were observed with omicron, due to the occurrence of low viral loads (CT > 30 in 32% of samples) during the two first days following symptom onset. Several LFTs exhibited satisfactory sensitivity and specificity, whereas a few others yielded an unacceptable proportion of false-positive results and/or lacked sensitivity. The sensitivity of the best-performing assays was not influenced by VOC, including alpha, beta, delta, and omicron variants. The ability of LFTs to detect the omicron variant could be reduced during the first days following symptom onset due to lower viral loads than with other variants. IMPORTANCE The use of lateral-flow tests (LFTs) to detect SARS-CoV-2 has expanded worldwide. LFTs detect SARS-CoV-2 viral antigen and are less sensitive than nucleic acid amplification testing (NAAT). Their performance must be evaluated independently of the manufacturers. Our study assessed the performance of 22 SARS-CoV-2 antigen LFTs in large panels of well-characterized samples. The majority of LFTs tested exhibited satisfactory sensitivity and specificity, while some assays yielded unacceptable proportions of false-positive results, and others lacked sensitivity for samples containing large amounts of virus. The sensitivity of the best-performing assays did not vary according to the VOC, including the alpha, beta, delta, and omicron variants.


Asunto(s)
COVID-19 , Ácidos Nucleicos , COVID-19/diagnóstico , Humanos , SARS-CoV-2/genética , Pruebas Serológicas/métodos
3.
J Clin Virol ; 146: 105048, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34863056

RESUMEN

Direct detection of SARS-CoV-2 viral antigens could replace RT-PCR, provided that its clinical performance is validated in different epidemiological settings. Here, we evaluated the performance of the VITROS Antigen test, an enzyme immunoassay detecting a SARS-CoV-2 antigen, in NPSs from 3 cohorts of patients. METHODS: Three cohorts including SARS-CoV-2 RNA-positive samples collected during the first and second wave of the French epidemic between March 2020 and February 2021 (including variant B.1.1.7/α and variant B.1.351/ß). RESULTS: Among the 1763 prospectively tested subjects, 8.2% (145/1763) were SARS-CoV-2 RNA-positive by RT-PCR. Using Ct ≤ 30 and Ct ≤ 35 as thresholds, the sensitivities of the antigen assay were 98.8% (93.6-100%) and 93.5% (87.0-97.3%), respectively. The overall specificity of the assay was 100% (1614/1614; 99.8-100%). In a retrospective cohort of subjects infected with variants of concern, 90.4% (47/52) of NPSs containing B. B.1.1.7/α (Ct ≤ 35) and 100% (7/7) of those containing B.1.351/ß were positive with the VITROS EIA SARS-CoV-2 Antigen test. CONCLUSION: The excellent performance of the EIA Antigen test reported here, including in patients infected with viral "variants of concern", support the use of high-throughput, EIA-based SARS-CoV-2 antigen assays as an alternative or complement to nucleic acid testing in order to scale-up laboratory screening and diagnostic capacities.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Humanos , Inmunoensayo , Técnicas para Inmunoenzimas , ARN Viral , Estudios Retrospectivos , Sensibilidad y Especificidad
4.
J Clin Virol ; 142: 104930, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34390929

RESUMEN

BACKGROUND: Direct detection of SARS-CoV-2 viral proteins in nasopharyngeal swabs using lateral flow immunoassays is a simple, fast and cheap approach to diagnose the infection. AIMS AND METHODS: The performance of 6 SARS-CoV-2 antigen rapid diagnostic tests has been assessed in 634 hospitalized patients or outpatients including 297 patients found to be positive for SARS-CoV-2 RNA by means of RT-PCR and 337 patients presumed to be SARS-CoV-2 RNA-negative. RESULTS: The specificity of SARS-CoV-2 RDTs was generally high (398.5%). One assay had a lower specificity of 93.2%. The overall sensitivity of the 6 RDTs was variable, from 32.3% to 61.7%. Sensitivity correlated with the delay of sampling after the onset of symptoms and the viral load estimated by the Ct value in RT-PCR. Four out of 6 RDTs tested achieved sensitivities 380% when clinical specimens were collected during the first 3 days following symptom onset or with a Ct value ≤25. CONCLUSIONS: The present study shows that SARS-CoV-2 antigen can be easily and reliably detected by RDTs. These tests are easy and rapid to perform. However, the specificity and sensitivity of COVID-19 antigen RDTs may widely vary across different tests and must therefore be carefully evaluated before releasing these assays for realworld applications.


Asunto(s)
COVID-19 , SARS-CoV-2 , Antígenos Virales , Pruebas Diagnósticas de Rutina , Humanos , ARN Viral , Sensibilidad y Especificidad
5.
Emerg Infect Dis ; 27(5): 1540-1543, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33900195

RESUMEN

We report a novel severe acute respiratory syndrome coronavirus 2 variant derived from clade 19B (HMN.19B variant or Henri Mondor variant). This variant is characterized by the presence of 18 amino acid substitutions, including 7-8 substitutions in the spike protein and 2 deletions. These variants actively circulate in different regions of France.


Asunto(s)
COVID-19 , SARS-CoV-2 , Sustitución de Aminoácidos , Francia/epidemiología , Humanos , Glicoproteína de la Espiga del Coronavirus/genética
6.
Sci Rep ; 6: 35689, 2016 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-27767085

RESUMEN

While miniature inertial sensors offer a promising means for precisely detecting, quantifying and classifying animal behaviors, versatile inertial sensing devices adapted for small, freely-moving laboratory animals are still lacking. We developed a standalone and cost-effective platform for performing high-rate wireless inertial measurements of head movements in rats. Our system is designed to enable real-time bidirectional communication between the headborne inertial sensing device and third party systems, which can be used for precise data timestamping and low-latency motion-triggered applications. We illustrate the usefulness of our system in diverse experimental situations. We show that our system can be used for precisely quantifying motor responses evoked by external stimuli, for characterizing head kinematics during normal behavior and for monitoring head posture under normal and pathological conditions obtained using unilateral vestibular lesions. We also introduce and validate a novel method for automatically quantifying behavioral freezing during Pavlovian fear conditioning experiments, which offers superior performance in terms of precision, temporal resolution and efficiency. Thus, this system precisely acquires movement information in freely-moving animals, and can enable objective and quantitative behavioral scoring methods in a wide variety of experimental situations.


Asunto(s)
Movimientos de la Cabeza/fisiología , Tecnología Inalámbrica/instrumentación , Acelerometría/instrumentación , Animales , Conducta Animal/fisiología , Fenómenos Biomecánicos , Condicionamiento Psicológico/fisiología , Diseño de Equipo , Miedo/fisiología , Masculino , Ratas , Ratas Long-Evans , Vestíbulo del Laberinto/lesiones , Vestíbulo del Laberinto/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...