Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Blood Transfus ; 21(2): 157-167, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-35302481

RESUMEN

BACKGROUND: Platelet transfusions can be associated with adverse reactions, such as febrile non-haemolytic transfusion reaction (FNHTR). It has been suggested that damage-associated molecular patterns (DAMP) and complement play a role in FNHTR. This study investigated the nature of DAMPs and complement activation products contained in platelet concentrates during storage, with a specific focus on different platelet storage solutions. MATERIALS AND METHODS: Buffy coats (BC) from healthy donors were pooled (15 BC per pool) and divided into three groups of the same volume. After addition of different storage solutions (plasma, platelet additive solutions [PAS]-C or PAS-E; n=6 for each group), BC pools were processed to platelet concentrates (PC). Leukoreduced PCs were stored on a shaking bed at 20-24°C and sampled on days 1, 2, 6 and 8 after collection for selected quality parameters: platelet activation, DAMPs (High Mobility Group Box 1 [HMGB1], nucleosomes), and complement activation products. RESULTS: During storage, equal levels of free nucleosomes and increasing concentrations of HMGB1 were present in all groups. Complement activation was observed in all PC. However, by day 8, the use of PAS had reduced C3b/c levels by approximately 90% and C4b/c levels by approximately 65%. DISCUSSION: Nucleosomes and HMGB1 were present in PCs prepared in plasma and PAS. Complement was activated during storage of platelets in plasma and in PAS. The use of PAS is associated with a lower amount of complement activation products due to the dilution of plasma by PAS . Therefore, PC in PAS have less complement activation products than platelets stored in plasma. These proinflammatory mediators in PC might induce FNHTR.


Asunto(s)
Conservación de la Sangre , Activación de Complemento , Plasma , Transfusión de Plaquetas , Soluciones , Reacción a la Transfusión , Humanos , Factores de Coagulación Sanguínea/análisis , Plaquetas , Conservación de la Sangre/efectos adversos , Conservación de la Sangre/métodos , Activación de Complemento/inmunología , Proteína HMGB1/análisis , Nucleosomas/inmunología , Activación Plaquetaria/inmunología , Transfusión de Plaquetas/efectos adversos , Transfusión de Plaquetas/métodos , Soluciones/efectos adversos , Soluciones/farmacología , Soluciones/uso terapéutico , Reacción a la Transfusión/etiología , Reacción a la Transfusión/prevención & control , Plasma/química , Plasma/inmunología , Capa Leucocitaria de la Sangre/química , Capa Leucocitaria de la Sangre/citología
2.
Transfusion ; 63(1): 217-228, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36453841

RESUMEN

BACKGROUND: Structural and biochemical changes in stored platelets are influenced by collection and processing methods. This international study investigates the effects of platelet (PLT) processing and storage conditions on HMGB1, sCD40L, and sCD62P protein levels in platelet concentrate supernatants (PCs). STUDY DESIGN/METHODS: PC supernatants (n = 3748) were collected by each international centre using identical centrifugation methods (n = 9) and tested centrally using the ELISA/Luminex platform. Apheresis versus the buffy coat (BC-PC) method, plasma storage versus PAS and RT storage versus cold (4°C) were investigated. We focused on PC preparation collecting samples during early (RT: day 1-3; cold: day 1-5) and late (RT: day 4-7; cold: day 7-10) storage time points. RESULTS: HMGB1, sCD40L, and sCD62P concentrations were similar during early storage periods, regardless of storage solution (BC-PC plasma and BC-PC PAS-E) or temperature. During storage and without PAS, sCD40L and CD62P in BC-PC supernatants increased significantly (+33% and +41%, respectively) depending on storage temperature (22 vs. 4°C). However, without PAS-E, levels decreased significantly (-31% and -20%, respectively), depending on storage temperature (22 vs. 4°C). Contrastingly, the processing method appeared to have greater impact on HMGB1 release versus storage duration. These data highlight increases in these parameters during storage and differences between preparation methods and storage temperatures. CONCLUSIONS: The HMGB1 release mechanism/intracellular pathways appear to differ from sCD62P and sCD40L. The extent to which these differences affect patient outcomes, particularly post-transfusion platelet increment and adverse events, warrants further investigation in clinical trials with various therapeutic indications.


Asunto(s)
Eliminación de Componentes Sanguíneos , Proteína HMGB1 , Humanos , Eliminación de Componentes Sanguíneos/métodos , Plaquetas/metabolismo , Conservación de la Sangre/métodos , Ligando de CD40/metabolismo , Proteína HMGB1/metabolismo , Transfusión de Plaquetas
3.
Vox Sang ; 117(10): 1163-1170, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36102116

RESUMEN

BACKGROUND AND OBJECTIVES: Di-ethyl-hexyl-phthalate (DEHP) is currently the main plasticizer used for whole blood collection systems. However, in Europe, after May 2025, DEHP may no longer be used above 0.1% (w/w) in medical devices. DEHP stabilizes red cell membranes, thereby suppressing haemolysis during storage. Here we compared in vitro quality parameters of red cell concentrates (RCCs) collected and stored in DEHP-, DINCH- or DINCH/BTHC-PVC hybrid blood bags with saline-adenine-glucose-mannitol (SAGM) or phosphate-adenine-glucose-guanosine-saline-mannitol (PAGGSM) storage solution. Last, we performed haemovigilance surveillance for RCC collected in DINCH-PVC and stored in PAGGSM/BTHC-PVC. MATERIALS AND METHODS: In vitro quality parameters of RCC were determined during 42 days of storage. Haemovigilance surveillance was conducted to compare the frequency and type of transfusion reaction. RESULTS: Haemolysis levels were increased in SAGM/BTHC-PVC as compared to SAGM/DEHP-PVC (0.66% ± 0.18% vs. 0.36% ± 0.17%). PAGGSM storage solution was able to adequately suppress haemolysis to levels observed during storage in SAGM/DEHP-PVC, both in BTHC-PVC (0.38% ± 0.12%), and to a slightly lesser extent in DINCH-PVC (0.48% ± 0.17%). A total of 1650 PAGGSM/BTHC-PVC and 5662 SAGM/DEHP-PVC RCC were transfused yielding a transfusion reaction frequency of 0.24% (95% CI 0.0000-0.0048) and 0.44% (95% CI 0.0027-0.0061) respectively. CONCLUSION: The in vitro quality of RCC stored in PAGGSM/BTHC-PVC and SAGM/DEHP-PVC is comparable. There is no indication that transfusion of erythrocytes stored in PAGGSM/BTHC-PVC results in increased transfusion reaction frequency. These initial results provide a basis for further clinical evaluation to narrow down the confidence interval of transfusion reaction frequency.


Asunto(s)
Carcinoma de Células Renales , Dietilhexil Ftalato , Neoplasias Renales , Reacción a la Transfusión , Adenina/farmacología , Conservación de la Sangre/métodos , Butiratos , Carcinoma de Células Renales/metabolismo , Eritrocitos/metabolismo , Glucosa/metabolismo , Guanosina , Hemólisis , Humanos , Neoplasias Renales/metabolismo , Manitol/farmacología , Fosfatos/metabolismo , Plastificantes , Cloruro de Polivinilo , Cloruro de Sodio
4.
Transfusion ; 59(9): 2964-2973, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31318461

RESUMEN

BACKGROUND: Labeling of platelets (PLTs) is required to measure the recovery and survival of transfused PLTs in vivo. Currently a radioactive method is used to label PLTs. However, application of those radiolabeling methods is limited by both safety issues and the inability to isolate transfused PLTs from the circulation. Biotin-labeled PLTs are an attractive nonradioactive option. However, no validated protocol to biotinylate PLTs is currently available for human studies. STUDY DESIGN AND METHODS: Six PLT concentrates (PCs) were subaliquoted and biotinylated on Days 1 and 7 of storage. To distinguish the effect of the processing steps from the effects of biotin incubation, two control groups were used: 1) "sham" samples were processed without the biotinylation reagent and 2) control samples were assessed without any processing other than the PC isolation. For the biotinylation procedure, 50 mL of PCs was washed twice and incubated with 5 mg/L biotin for 30 minutes in a closed system. As measures of PLT activation, phosphatidylserine exposure and CD62p expression were assessed. RESULTS: After biotinylation, 98.4% ± 0.9% of PLTs were labeled. PLT counts, pH, and "swirling" were within the range accepted by the Dutch blood bank for standard PLT products. Biotinylated PLTs were more activated compared than controles but not more than sham samples, but were more activated than the controls. CONCLUSION: We developed a standardized and reproducible protocol according to Good Practice Guidelines standards, for biotin labeling of PLTs for clinical purposes. This method can be applied as nonradioactive alternative assess survival and recovery of transfused PLTs in vivo.


Asunto(s)
Biotinilación/fisiología , Plaquetas/citología , Plaquetas/metabolismo , Rastreo Celular/métodos , Transfusión de Plaquetas , Coloración y Etiquetado/métodos , Biotina/análisis , Biotina/metabolismo , Biotina/farmacología , Plaquetas/química , Conservación de la Sangre , Supervivencia Celular/efectos de los fármacos , Estabilidad de Medicamentos , Citometría de Flujo , Supervivencia de Injerto , Humanos , Recuento de Plaquetas/métodos
5.
Transfusion ; 58(11): 2627-2634, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30265755

RESUMEN

BACKGROUND: Apheresis is increasingly being applied to collect cells or plasma, even allowing the collection of multiple blood components during one procedure. Although the quality of the cellular and plasma products that are obtained by apheresis have been extensively studied and shown to be of high quality, the impact of apheresis on the red blood cells (RBCs) that are returned to the donor has not been investigated. STUDY DESIGN AND METHODS: The effect of the plasma- or plateletpheresis procedures by four different devices-MCS+ (Haemonetics), PCS2 (Haemonetics), Trima Accel (Terumo BCT), and Autopheresis-C (Auto-C, Fresenius Kabi)-on the RBCs that are returned to the donor was tested in a blinded, prospective trial in a cohort of 25 donors. RESULTS: A rheologic analysis of donor RBCs before and after plasma- or plateletpheresis showed no differences in outcome. However, a strong increase in hemolysis was found in samples from the Trima Accel devices after plateletpheresis, compared to all other machines tested. Furthermore, an increase in complement deposition on RBCs was seen after all plasmapheresis procedures (MCS+, PCS2, and Auto-C). Finally, a significant decrease in the expression of the complement-regulating protein CD59 was seen in all postapheresis samples as well as a significant decrease of the adhesion molecule CD147. CONCLUSION: The increase in complement deposition and the decrease in the expression of CD59 suggests that RBC clearance might be enhanced after return to the donor. Possible side effects due to an increase in hemolysis after Trima Accel plateletpheresis should be further investigated.


Asunto(s)
Eliminación de Componentes Sanguíneos/efectos adversos , Eritrocitos/metabolismo , Antígenos CD59/metabolismo , Citometría de Flujo , Hemólisis , Humanos , Plaquetoferesis/efectos adversos
6.
Transfusion ; 55(3): 522-31, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25331824

RESUMEN

BACKGROUND: The plasticizer di(2-ethylhexyl)phthalate (DEHP) is a common component in blood bags. DEHP is noncovalently bound to polyvinylchloride (PVC) polymer and can leach into the blood product. There are public concerns that exposure to DEHP might induce developmental and reproductive toxicity in humans. The aim of this study was to evaluate an alternative plasticizer, di(isononyl) cyclohexane-1,2-dicarboxylate (Hexamoll DINCH, BASF SE), for its use in blood bags. STUDY DESIGN AND METHODS: Whole blood (WB) was collected into DEHP-containing and DEHP-free collection systems. After overnight hold, WB was centrifuged and separated in plasma, buffy coat, and red blood cells (RBCs). Buffy coats and plasma were used to make platelet (PLT) concentrates in DEHP-free systems. After addition of additive solution (AS), SAG-M, PAGGS-M, AS-3, or PAGGG-M, RBCs were leukoreduced and analyzed for in vitro characteristics and plasticizer levels during storage. RESULTS: The use of DINCH-based systems had no effect on WB composition, blood processing, and plasma quality. PLT in vitro quality variables were maintained during storage in DEHP-free systems. During storage in SAG-M, hemolysis was significantly higher in DINCH-PVC while potassium leakage and adenosine triphosphate content were comparable. During storage in alternative ASs, hemolysis was reduced compared to storage in SAG-M. CONCLUSIONS: The complete absence of DEHP in the collection system had no effect on WB composition, processing, or plasma and PLT quality. During storage in SAG-M, the absence of DEHP resulted in increased hemolysis. With alternative ASs like PAGGS-M, AS-3, or PAGGG-M, the absence of DEHP had no effect on hemolysis. Leakage of DINCH into the blood product was less pronounced than that of DEHP.


Asunto(s)
Conservación de la Sangre/instrumentación , Recolección de Muestras de Sangre/instrumentación , Ácidos Ciclohexanocarboxílicos , Ácidos Dicarboxílicos , Dietilhexil Ftalato , Plastificantes , Adenina/farmacología , Células Sanguíneas/citología , Células Sanguíneas/efectos de los fármacos , Coagulación Sanguínea/efectos de los fármacos , Citratos/farmacología , Criopreservación/instrumentación , Dietilhexil Ftalato/sangre , Glucosa/farmacología , Guanosina/farmacología , Hemólisis/efectos de los fármacos , Humanos , Técnicas In Vitro , Procedimientos de Reducción del Leucocitos , Manitol/farmacología , Soluciones Farmacéuticas/farmacología , Fosfatos/farmacología , Plastificantes/análisis , Cloruro de Sodio/farmacología , Factores de Tiempo
7.
Transfusion ; 49(6): 1233-41, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19290994

RESUMEN

BACKGROUND: Stored platelets (PLTs) are metabolically active, resulting in a decrease of pH during storage. The pH of PLT concentrates (PCs) is recognized as a measure of quality, and pH limits are set by regulatory bodies. A pH sensor was built into a PLT storage container, and the feasibility of testing pH using a noninvasive fluorescent measurement method was evaluated. STUDY DESIGN AND METHODS: A citrated polyvinylchloride (PVC) PLT storage container with pH sensor insert was made and evaluated for biocompatibility during PLT storage and on pH reading accuracy, reproducibility, and durability. A noninvasive fluorescence reader was tested versus syringe-based sampling and subsequent measurement with a blood gas analyzer (BGA). The effect of interfering substances in plasma on the accuracy of this optical measurement was tested. Calibration and accuracy of the pH sensor were determined in both phosphate-buffered saline and in PCs. RESULTS: The citrated PVC storage container with pH sensor insert showed good storage properties for 300 mL of pooled buffy coat PLTs in plasma over 7 days. The pH sensor was easy to use and tracked pH(22) in the range of 6.2 to 7.8 over 11 days of storage. Accuracy in PCs was 0.08 pH units measured at 22 degrees C when calibrated against a BGA. CONCLUSION: The storage container with integrated pH sensor and noninvasive reader allows pH of PCs to be tracked over time in a noninvasive manner.


Asunto(s)
Plaquetas/metabolismo , Tecnología de Fibra Óptica/instrumentación , Concentración de Iones de Hidrógeno , Calibración , Fluorometría , Humanos
8.
Transfusion ; 45(1): 82-9, 2005 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-15647022

RESUMEN

BACKGROUND: Deterioration of platelet (PLT) quality during storage is accompanied by an increase in lactate production, indicating a decrease in mitochondrial function. In this study, the optimal conditions under which the fluorescent dye JC-1 can be used to detect changes in mitochondrial function in PLTs were established. STUDY DESIGN AND METHODS: PLTs were incubated at 37 degrees C in synthetic medium under various conditions of JC-1 loading. In the presence of a high membrane potential, this dye accumulates in the mitochondria with a concomitant increase in red fluorescence. After JC-1 loading, the ratio of red (FL2) to green (FL1) fluorescence was determined by flow cytometry. RESULTS: The FL2-to-FL1 ratio of PLTs (3 x 10(7)/mL, loaded with 0.5 micromol/L JC-1) amounted to about 5 in 1-day-old PLTs. At higher dye concentrations, the FL2-to-FL1 ratio was significantly lower, suggesting uncoupling by the dye itself. Plasma concentrations above 3 percent significantly affected the JC-1 signal. The FL2-to-FL1 ratio showed a dose-dependent decrease to an uncoupler of oxidative phosphorylation or to inhibition of the respiratory chain. JC-1-loaded PLTs showed a clear decrease in FL2-to-FL1 ratio after prolonged storage or upon ultraviolet (UV) illumination. Only after UV treatment did changes in JC-1 signal correlate with changes in CD62P expression. CONCLUSION: The FL2-to-F1 ratio of PLTs loaded with JC-1 is a reliable and sensitive indicator of the mitochondrial membrane potential, provided that the proper experimental conditions have been applied.


Asunto(s)
Plaquetas/fisiología , Mitocondrias/fisiología , Citometría de Flujo , Colorantes Fluorescentes , Humanos , Potenciales de la Membrana , Selectina-P/sangre , Rayos Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA