Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Int J Radiat Biol ; : 1-11, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38953870

RESUMEN

PURPOSE: Radiation-induced alterations in gene expression show great promise for dose reconstruction and for severity prediction of acute health effects. Among several genes explored as potential biomarkers, FDXR is widely used due to high upregulation in white blood cells following radiation exposure. Nonetheless, the absence of a standardized protocols for gene expression-based biodosimetry is a notable gap that warrants attention to enhance the accuracy, reproducibility and reliability. The objective of this study was to evaluate the sensitivity of transcriptional biodosimetry to differences in protocols used by different laboratories and establish guidelines for the calculation of calibration curve using FDXR expression data. MATERIAL AND METHODS: Two sets of irradiated blood samples generated during RENEB exercise were used. The first included samples irradiated with known doses including: 0, 0.25, 0.5, 1, 2, 3 and 4 Gy. The second set consisted of three 'blind' samples irradiated with 1.8 Gy, 0.4 Gy and a sham-irradiated sample. After irradiation, samples were incubated at 37 °C over 24 h and sent to participating laboratories, where RNA isolation and FDXR expression analysis by qPCR were performed using sets of primers/probes and reference genes specific for each laboratory. Calibration curves based on FDXR expression data were generated using non-linear and linear regression and used for dose estimation of 'blind' samples. RESULTS: Dose estimates for sham-irradiated sample (0.020-0.024 Gy) and sample irradiated with 0.4 Gy (0.369-0.381 Gy) showed remarkable consistency across all laboratories, closely approximating the true doses regardless variation in primers/probes and reference genes used. For sample irradiated with 1.8 Gy the dose estimates were less precise (1.198-2.011 Gy) but remained within an acceptable margin for triage within the context of high dose range. CONCLUSION: Methodological differences in reference genes and primers/probes used for FDXR expression measurement do not have a significant impact on the dose estimates generated, provided that all reference genes performed as expected and the primers/probes target a similar set of transcript variants. The preferred method for constructing a calibration curve based on FDXR expression data involves employing linear regression to establish a function that describes the relationship between the logarithm of absorbed dose and FDXR ΔCt values. However, one should be careful with using non-irradiated sample data as these cannot be accurately represented on a logarithmic scale. A standard curve generated using this approach can give reliable dose estimations in a dose range from 50 mGy to 4 Gy at least.

2.
Cytogenet Genome Res ; 163(3-4): 163-177, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37071978

RESUMEN

In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated, and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0-4 Gy at two different facilities in Germany (Physikalisch-Technische Bundesanstalt [PTB]) and the USA (the Columbia IND Neutron Facility [CINF]). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semiautomatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semiautomatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed nonlinear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.


Asunto(s)
Neutrones , Humanos , Alemania
3.
Radiat Res ; 196(6): 668-679, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34554263

RESUMEN

Treatment of accidental radiation-induced myelosuppression is primarily based on supportive care and requires specific treatment based on hematopoietic growth factors injection or hematopoietic cell transplantation for the most severe cases. The cytokines used consisted of pegylated erythropoietin (darbepoetin alfa) 500 IU once per week, pegylated G-CSF (pegfilgrastim) 6 mg × 2 once, stem cell factor 20 µg.kg-1 for five days, and romiplostim (TPO analog) 10 µg.kg -1 once per week, with different combinations depending on the accidents. As the stem cell factor did not have regulatory approval for clinical use in France, the French regulatory authorities (ANSM, formerly, AFSSAPS) approved their compassionate use as an investigational drug "on a case-by-case basis". According to the evolution and clinical characteristics, each patient's treatment was adopted on an individual basis. Daily blood count allows initiating G-CSF and SCF delivery when granulocyte <1,000/mm3, TPO delivery when platelets <50,000/mm3, and EPO when Hb<80 g/L. The length of each treatment was based on blood cell recovery criteria. The concept of "stimulation strategy" is linked to each patient's residual hematopoiesis, which varies among them, depending on the radiation exposure's characteristics and heterogeneity. This paper reports the medical management of 8 overexposed patients to ionizing radiation. The recovery of bone marrow function after myelosuppression was accelerated using growth factors, optimized by multiple-line combinations. Particularly in the event of prolonged exposure to ionizing radiation in dose ranges inducing severe myelosuppression (in the order of 5 to 8 Gy), with no indication of hematopoietic stem cell transplantation.


Asunto(s)
Médula Ósea/efectos de la radiación , Citocinas/uso terapéutico , Liberación de Radiactividad Peligrosa , Médula Ósea/metabolismo , Citocinas/administración & dosificación , Humanos , Irradiación Corporal Total
4.
Int J Radiat Biol ; 97(9): 1181-1198, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34138666

RESUMEN

PURPOSE: Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS: For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS: The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS: The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.


Asunto(s)
Cromosomas Humanos/genética , Cromosomas Humanos/efectos de la radiación , Radiometría , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Exposición a la Radiación/análisis , Estudios Retrospectivos
5.
Int J Radiat Biol ; 97(7): 888-905, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33970757

RESUMEN

PURPOSE: In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. MATERIALS AND METHODS: Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. RESULTS: This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. CONCLUSIONS: Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.


Asunto(s)
Laboratorios , Radiometría , Aberraciones Cromosómicas/efectos de la radiación , Humanos , Exposición a la Radiación , Reproducibilidad de los Resultados
6.
Environ Int ; 146: 106175, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33069983

RESUMEN

The experiences of the Chernobyl and Fukushima nuclear accidents showed that dosimetry was the essential tool in the emergency situation for decision making processes, such as evacuation and application of protective measures. However, at the consequent post-accidental phases, it was crucial also for medical health surveillance and in further adaptation to changed conditions with regards to radiation protection of the affected populations. This review provides an analysis of the experiences related to the role of dosimetry (dose measurements, assessment and reconstruction) regarding health preventive measures in the post-accidental periods on the examples of the major past nuclear accidents such as Chernobyl and Fukushima. Recommendations derived from the review are called to improve individual dose assessment in case of a radiological accident/incident and should be considered in advance as guidelines to follow for having better information. They are given as conclusions.


Asunto(s)
Accidente Nuclear de Chernóbil , Accidente Nuclear de Fukushima , Monitoreo de Radiación , Protección Radiológica , Humanos , Japón
7.
Environ Mol Mutagen ; 59(7): 586-594, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-30151952

RESUMEN

Existing and future nuclear fusion technologies involve the production and use of large quantities of tritium, a highly volatile, but low toxicity beta-emitting isotope of hydrogen. Tritium has received international attention because of public and scientific concerns over its release to the environment and the potential health impact of its internalization. This article provides a brief summary of the current state of knowledge of both the biological and regulatory aspects of tritium exposure; it also explores the gaps in this knowledge and provides recommendations on the best ways forward for improving our understanding of the health effects of low-level exposure to it. Linking health effects specifically to tritium exposure is challenging in epidemiological studies due to high uncertainty in tritium dosimetry and often suboptimal cohort sizes. We therefore argued that limits for tritium in drinking water should be based on evidence derived from controlled in vivo animal tritium toxicity studies that use realistically low levels of tritium. This article presents one such mouse study, undertaken within an international collaboration, and discusses the implications of its main findings, such as the similarity of the biokinetics of tritiated water (HTO) and organically bound tritium (OBT) and the higher biological effectiveness of OBT. This discussion is consistent with the position expressed in this article that in vivo animal tritium toxicity studies carried out within large, multi-partner collaborations allow evaluation of a great variety of health-related endpoints and essential to the development of international consensus on the regulation of tritium levels in the environment. Environ. Mol. Mutagen. 59:586-594, 2018. © 2018 The Authors Environmental and Molecular Mutagenesis published by Wiley Periodicals, Inc. on behalf of Environmental Mutagen Society.


Asunto(s)
Agua Potable/efectos adversos , Tritio/efectos adversos , Aminoácidos/análisis , Aminoácidos/farmacocinética , Animales , Sitios de Unión , Consenso , Agua Potable/análisis , Rayos gamma/efectos adversos , Dosimetría in Vivo , Masculino , Ratones , Ratones Endogámicos C57BL , Modelos Animales , Monitoreo de Radiación , Riesgo , Distribución Tisular , Tritio/análisis , Tritio/farmacocinética , Tritio/toxicidad , Organización Mundial de la Salud
8.
Oncotarget ; 9(44): 27397-27411, 2018 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-29937993

RESUMEN

The aim of this study was to carry out a comprehensive examination of potential genotoxic effects of low doses of tritium delivered chronically to mice and to compare these effects to the ones resulting from equivalent doses of gamma-irradiation. Mice were chronically exposed for one or eight months to either tritiated water (HTO) or organically bound tritium (OBT) in drinking water at concentrations of 10 kBq/L, 1 MBq/L or 20 MBq/L. Dose rates of internal ß-particle resulting from such tritium treatments were calculated and matching external gamma-exposures were carried out. We measured cytogenetic damage in bone marrow and in peripheral blood lymphocytes (PBLs) and the cumulative tritium doses (0.009 - 181 mGy) were used to evaluate the dose-response of OBT in PBLs, as well as its relative biological effectiveness (RBE). Neither tritium, nor gamma exposures produced genotoxic effects in bone marrow. However, significant increases in chromosome damage rates in PBLs were found as a result of chronic OBT exposures at 1 and 20 M Bq/L, but not at 10 kBq/L. When compared to an external acute gamma-exposure ex vivo, the RBE of OBT for chromosome aberrations induction was evaluated to be significantly higher than 1 at cumulative tritium doses below 10 mGy. Although found non-existent at 10 kBq/L (the WHO limit), the genotoxic potential of low doses of tritium (>10 kBq/L), mainly OBT, may be higher than currently assumed.

9.
Int J Radiat Biol ; 94(3): 248-258, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29363380

RESUMEN

PURPOSE: The fluorescent in situ hybridization (FISH) technique, which easily detects reciprocal translocations, is currently used to estimate doses in retrospective biological dosimetry, after suspected accidental overexposure to ionizing radiation (IR). This study of 42 cases aimed to verify the appropriateness of this assay for radiation dose reconstruction, compared to the dicentric assay, and to evaluate other limitations. MATERIAL AND METHODS: We labeled chromosomes 2, 4, and 12 by 3-color FISH painting to detect translocations on lymphocytes of patients with suspected past IR overexposure. RESULT: Translocation dose estimation showed doses significantly different from 0 Gy in 25 of the 42 cases. The lowest positive dose measured was 0.3 Gy. Several months after IR exposure, the doses measured by translocation and dicentric assays are quite similar. For a year, dose estimation by translocation assay becomes more relevant as dicentric frequency starts to decrease, coming close to 0 for more than a year after the exposure. The persistence of translocations enabled us to corroborate an overexposure 44 years earlier. Interpretation of the observed translocation yield requires the knowledge of the patient's other radiation exposures. A dose assessment by this biomarker is relevant only if the radiation exposure is confirmed. CONCLUSIONS: This technique is appropriate for corroborating a former IR exposure of individuals. When the radiation dose is greater than 1 Gy, the translocations in complex exchanges must be considered. Another relevant point is the use of an appropriate background yield of translocations. The dose assessment, however, also depends on exposure to various genotoxic agents besides IR. If no evidence about the existence of radiation exposure is available, dose assessment is not useful. For this reason, report only the translocation frequency and its comparison with the background yield by age class is preferable.


Asunto(s)
Hibridación Fluorescente in Situ , Radiometría/métodos , Translocación Genética/efectos de la radiación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo
10.
Genome Integr ; 8: 4, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28250911

RESUMEN

One of the most widely employed histone deacetylases inhibitors in the clinic is the valproic acid (VA), proving to have a good tolerance and low side effects on human health. VA induces changes in chromatin structure making DNA more susceptible to damage induction and influence DNA repair efficiency. VA is also proposed as a radiosensitizing agent. To know if VA is suitable to sensitize human lymphocytes γ-irradiation in vitro, different types of chromosomal aberrations in the lymphocytes, either in the absence or presence of VA, were analyzed. For this purpose, blood samples from four healthy donors were exposed to γ-rays at a dose of 1.5 Gy and then treated with two different doses of VA (0.35 or 0.70 mM). Unstable and stable chromosomal aberrations were analyzed by means of fluorescence in situ hybridization. Human lymphocytes treated with VA alone did not show any increase in the frequency of chromosomal aberrations. However, a moderate degree of sensitization was observed, through the increase of chromosomal aberrations, when 0.35 mM VA was employed after γ-irradiation, whereas 0.70 mM VA did not modify chromosomal aberration frequencies. The lower number of chromosomal aberrations obtained when VA was employed at higher dose after γ-irradiation, could be related to the induction of a cell cycle arrest, a fact that should be taken into consideration when VA is employed in combination with physical or chemical agents.

11.
Int J Radiat Biol ; 93(1): 118-126, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27735728

RESUMEN

PURPOSE: In the frame of the QA program of RENEB, an inter-laboratory comparison (ILC) of calibration sources used in biological dosimetry was achieved to investigate the influence of calibration practices and protocols on the results of the dose estimation performance as a first step to harmonization and standardization of dosimetry and irradiation practices in the European biological dosimetry network. MATERIALS AND METHODS: Delivered doses by irradiation facilities used by RENEB partners were determined with EPR/alanine dosimetry system. Dosimeters were irradiated in the same conditions as blood samples. A short survey was also performed to collect the information needed for the data analysis and evaluate the diversity of practices. RESULTS: For most of partners the deviation of delivered dose from the targeted dose remains below 10%. Deviations larger than 10% were observed for five facilities out of 21. Origins of the largest discrepancies were identified. Correction actions were evaluated as satisfactory. The re-evaluation of some ILC results for the fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC) assays has been performed leading to an improvement of the overall performances. CONCLUSIONS: This work has shown the importance of dosimetry in radiobiology studies and the needs of harmonization, standardization in irradiation and dosimetry practices and educational training for biologists using ionizing radiation.


Asunto(s)
Calibración/normas , Análisis Citogenético/normas , Laboratorios/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud/normas , Exposición a la Radiación/análisis , Monitoreo de Radiación/normas , Análisis Citogenético/estadística & datos numéricos , Europa (Continente) , Humanos , Laboratorios/normas , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Monitoreo de Radiación/estadística & datos numéricos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
12.
Int J Radiat Biol ; 93(1): 127-135, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27572921

RESUMEN

PURPOSE: Reliable dose estimation is an important factor in appropriate dosimetric triage categorization of exposed individuals to support radiation emergency response. MATERIALS AND METHODS: Following work done under the EU FP7 MULTIBIODOSE and RENEB projects, formal methods for defining uncertainties on biological dose estimates are compared using simulated and real data from recent exercises. RESULTS: The results demonstrate that a Bayesian method of uncertainty assessment is the most appropriate, even in the absence of detailed prior information. The relative accuracy and relevance of techniques for calculating uncertainty and combining assay results to produce single dose and uncertainty estimates is further discussed. CONCLUSIONS: Finally, it is demonstrated that whatever uncertainty estimation method is employed, ignoring the uncertainty on fast dose assessments can have an important impact on rapid biodosimetric categorization.


Asunto(s)
Algoritmos , Bioensayo/métodos , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Triaje/métodos , Teorema de Bayes , Europa (Continente) , Humanos , Guías de Práctica Clínica como Asunto , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
13.
Int J Radiat Biol ; 93(1): 136-141, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27557790

RESUMEN

PURPOSE: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems. MATERIALS AND METHODS: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties. The survey focused on several main areas: laboratory's general information, country and staff involved in biological and physical dosimetry; retrospective assays used, the number of assays available per laboratory and other information related to biodosimetry and emergency preparedness. Following technical intercomparisons amongst RENEB members, an update of the survey was performed one year later concerning the staff and the available assays. CONCLUSIONS: The analysis of RENEB questionnaires allowed a detailed assessment of existing capacity of the RENEB network to respond to nuclear and radiological emergencies. This highlighted the key importance of international cooperation in order to guarantee an effective and timely response in the event of radiological or nuclear accidents involving a considerable number of casualties. The deployment of the scientific and technical capabilities existing within the RENEB network members seems mandatory, to help other countries with less or no capacity for biological or physical dosimetry, or countries overwhelmed in case of a radiological or nuclear accident involving a large number of individuals.


Asunto(s)
Investigación Biomédica/organización & administración , Planificación en Desastres/organización & administración , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa , Administración de la Seguridad/organización & administración , Europa (Continente) , Modelos Organizacionales , Radiobiología/organización & administración
14.
Int J Radiat Biol ; 93(1): 75-80, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27559844

RESUMEN

PURPOSE: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. MATERIALS AND METHODS: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. RESULTS: The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). CONCLUSIONS: Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.


Asunto(s)
Planificación en Desastres/organización & administración , Monitoreo de Radiación/métodos , Liberación de Radiactividad Peligrosa , Radiobiología/educación , Administración de la Seguridad/organización & administración , Triaje/organización & administración , Europa (Continente)
15.
Int J Radiat Biol ; 93(1): 30-35, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27705052

RESUMEN

PURPOSE: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. MATERIALS AND METHODS: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. RESULTS: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. CONCLUSIONS: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.


Asunto(s)
Bioensayo/métodos , Hibridación Fluorescente in Situ/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Translocación Genética/efectos de la radiación , Bioensayo/normas , Europa (Continente) , Humanos , Hibridación Fluorescente in Situ/normas , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Translocación Genética/genética
16.
Int J Radiat Biol ; 93(1): 81-86, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27686284

RESUMEN

PURPOSE: The European Network of Biological and Physical Retrospective Dosimetry 'RENEB' has contributed to European radiation emergency preparedness. To give homogeneous dose estimation results, RENEB partners must harmonize their processes. MATERIALS AND METHODS: A first inter-comparison focused on biological and physical dosimetry was used to detect the outliers in terms of dose estimation. Subsequently, trainings were organized to improve both tools dose estimation. A second inter-comparison was performed to validate training efficiency. Simultaneously, based on ISO standards, a QA&QM manual on all dosimetry assays was produced which states a common basis and harmonized procedures for each assay. The evaluation of the agreement of RENEB partners to follow the QA&QM manual was performed through a questionnaire. The integration of new members into the network was carried out in the same way, whatever the assays. RESULTS: The training courses on biological and physical dosimetry were judged to be successful because most of the RENEB members' dose estimates improved in the second inter-comparison. The QA&QM manual describes the consensus for the minimum requirements and the performance criteria for both dosimetry assays. The questionnaire revealed that the whole network capacity currently can manage between 15 and 3800 samples once. CONCLUSION: The methodology used to harmonize all dosimetry practice within the network RENEB was highly successful. The network is operational to manage a mass casualty radiation accident for immediate dose assessment.


Asunto(s)
Adhesión a Directriz/estadística & datos numéricos , Guías de Práctica Clínica como Asunto , Garantía de la Calidad de Atención de Salud/normas , Exposición a la Radiación/análisis , Monitoreo de Radiación/estadística & datos numéricos , Monitoreo de Radiación/normas , Bioensayo/normas , Bioensayo/estadística & datos numéricos , Europa (Continente) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Int J Radiat Biol ; 93(1): 110-117, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27547893

RESUMEN

PURPOSE: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. MATERIALS AND METHODS: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. RESULTS: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. CONCLUSIONS: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.


Asunto(s)
Bioensayo/métodos , Análisis Citogenético/métodos , Internet/organización & administración , Linfocitos/efectos de la radiación , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Europa (Continente) , Humanos , Laboratorios/estadística & datos numéricos , Linfocitos/citología , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
18.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27707245

RESUMEN

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/organización & administración , Traumatismos por Radiación/prevención & control , Monitoreo de Radiación/métodos , Protección Radiológica/métodos , Administración de la Seguridad/organización & administración , Urgencias Médicas , Europa (Continente) , Humanos , Objetivos Organizacionales , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Liberación de Radiactividad Peligrosa/prevención & control
19.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27766931

RESUMEN

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
Int J Radiat Biol ; 93(1): 99-109, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27437830

RESUMEN

PURPOSE: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. MATERIALS AND METHODS: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. RESULTS: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. CONCLUSIONS: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.


Asunto(s)
Bioensayo/métodos , Planificación en Desastres/métodos , Laboratorios , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Administración de la Seguridad/métodos , Unión Europea , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Integración de Sistemas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...