Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
PLoS One ; 16(1): e0245134, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33411747

RESUMEN

OBJECTIVES: To assess the feasibility of quantitative analysis of dynamic computed tomography angiography (dCTA) for the detection of endoleaks in patients who underwent endovascular repair of abdominal aortic aneurysms (EVAR). MATERIAL AND METHODS: Twenty patients scheduled for contrast-enhanced CT angiography (CTA) of the abdominal aorta post-EVAR were prospectively enrolled. All patients received a standard triphasic CTA protocol, followed by an additional dCTA. The dCTA acquisition enabled reconstruction of color-coded maps depicting blood perfusion and a dCTA dataset of the aneurysm sac. Observers assessed the dCTA and dynamic CT perfusion (dCTP) images for the detection of endoleaks, establishing diagnostic confidence based on a modified 5-point Likert scale. An index was calculated for the ratio between the endoleak and aneurysm sac using blood flow for dCTP and Hounsfield units (HU) for dCTA. The Wilcoxon test compared the endoleak index and the diagnostic confidence of the observers. RESULTS: In total, 19 patients (18 males, median age 74 years [70.5-75.7]) were included for analysis. Nine endoleaks were detected in 7 patients using triphasic CTA as the reference standard. There was complete agreement for endoleak detection between the two techniques on a per-patient basis. Both dCTA and dCTP identified an additional endoleak in one patient. The diagnostic confidence using dCTP for detection of endoleaks was not significantly superior to dCTA (5.0 [5-5] vs. 4.5 [4-5], respectively; p = 0.11); however, dCTP demonstrated superior diagnostic confidence for endoleak exclusion compared to dCTA (1.0 [1-1] vs 1.5 [1.5-1.5], respectively; p <0.01). Moreover, the dCTP endoleak index was significantly higher than the dCTA index (18.5 [10.8-20.5] vs. 3.5 [5-2.7], respectively; p = 0.02). CONCLUSIONS: Quantitative analysis of dCTP imaging can aid in the detection of endoleaks and demonstrates a higher endoleak detection rate than triphasic CTA, as well as a strong correlation with visual assessment of dCTA images.


Asunto(s)
Aorta Abdominal , Aneurisma de la Aorta Abdominal , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Anciano , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Femenino , Humanos , Masculino
2.
Eur J Radiol ; 113: 140-147, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30927938

RESUMEN

PURPOSE: To develop institutional diagnostic reference levels (IDRL) for coronary CT angiography (CCTA) according to patient size by analyzing radiation dose changes over the past 10 years. MATERIALS AND METHODS: This IRB approved retrospective investigation analyzed radiation dose data from CCTA between 2007 and 2016 at our institution. Annual trends in radiation dose were described for each scanner type and scanning mode. Radiation levels were analyzed for normorhythmic patients, patients with prior coronary artery bypass grafting (CABG), arrhythmia, and according to patient size and tube voltage. Median, and quartile values for volume CT dose index (CTDIvol), dose-length product (DLP), and size-specific dose estimate (SSDE) were calculated. Wilcoxon rank-sum test and Kruskal Wallis test were performed to assess the significance of quantitative data. RESULTS: 35,375 examinations from 33,317 patients (median age, 58 [50-66] years; male patients, 21,087 [58.7%]) were analyzed. CTDIvol, DLP, and SSDE significantly decreased by 9.0%, 30.8%, and 40.1% (all P < 0.05) for all examinations, respectively. All radiation dose metrics progressively decreased across scanning modes (especially retrospectively ECG-gated spiral and prospectively ECG-triggered high-pitch spiral acquisition mode), but did not significantly change across scanners in the last 6 years. CTDIvol and DLP increased with patient size when water-equivalent diameters were >19 cm for normorhythmic and CABG patients. In arrhythmic patients, CTDIvol increased progressively with water-equivalent diameters across all groups. CONCLUSION: CCTA radiation dose has progressively decreased in the past decade except in patients with prior CABG and arrhythmia. Size-specific IDRLs may optimize radiation utilization in these patients going forward.


Asunto(s)
Angiografía por Tomografía Computarizada/tendencias , Angiografía Coronaria/tendencias , Anciano , Arritmias Cardíacas/diagnóstico por imagen , Angiografía por Tomografía Computarizada/normas , Tomografía Computarizada de Haz Cónico/normas , Tomografía Computarizada de Haz Cónico/tendencias , Angiografía Coronaria/normas , Puente de Arteria Coronaria/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Valores de Referencia , Estudios Retrospectivos , Estadísticas no Paramétricas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...