Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Int J Telemed Appl ; 2024: 4080415, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38567031

RESUMEN

Aims: Users of homecare services are often excluded from clinical trials due to advanced age, multimorbidity, and frailty. Atrial fibrillation (AF) is a common and frequently undiagnosed arrhythmia in the elderly and is associated with severe mortality, morbidity, and healthcare costs. Timely identification prevents associated complications through evidence-based treatment. This study is aimed at assessing the feasibility of AF screening using new digital health technology in older people in a homecare setting. Methods: Users of homecare services ≥ 65 years old with at least one additional risk factor for stroke in two Norwegian municipalities were assessed for study participation by nurses. Participants performed a continuous prolonged ECG recording using a patch ECG device (ECG247 Smart Heart Sensor). Results: A total of 144 individuals were assessed for study participation, but only 18 (13%) were included. The main reasons for noninclusion were known AF and/or anticoagulation therapy (25%), severe cognitive impairment (26%), and lack of willingness to participate (36%). The mean age of participants performing the ECG test was 81 (SD ± 7) years, and 9 (50%) were women. All ECG tests were interpretable; the mean ECG monitoring time was 104 hours (IQR 34-338 hours). AF was detected in one individual (6%). Conclusion: This feasibility study highlights the challenges of enrolling older people receiving homecare services in clinical trials. However, all included participants performed an interpretable and prolonged continuous ECG recording with a digital ECG patch device. This trial is registered with NCT04700865.

3.
Ultrasound Med Biol ; 50(6): 797-804, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38485534

RESUMEN

OBJECTIVE: Evaluation of left ventricular (LV) function in critical care patients is useful for guidance of therapy and early detection of LV dysfunction, but the tools currently available are too time-consuming. To resolve this issue, we previously proposed a method for the continuous and automatic quantification of global LV function in critical care patients based on the detection and tracking of anatomical landmarks on transesophageal heart ultrasound. In the present study, our aim was to improve the performance of mitral annulus detection in transesophageal echocardiography (TEE). METHODS: We investigated several state-of-the-art networks for both the detection and tracking of the mitral annulus in TEE. We integrated the networks into a pipeline for automatic assessment of LV function through estimation of the mitral annular plane systolic excursion (MAPSE), called autoMAPSE. TEE recordings from a total of 245 patients were collected from St. Olav's University Hospital and used to train and test the respective networks. We evaluated the agreement between autoMAPSE estimates and manual references annotated by expert echocardiographers in 30 Echolab patients and 50 critical care patients. Furthermore, we proposed a prototype of autoMAPSE for clinical integration and tested it in critical care patients in the intensive care unit. RESULTS: Compared with manual references, we achieved a mean difference of 0.8 (95% limits of agreement: -2.9 to 4.7) mm in Echolab patients, with a feasibility of 85.7%. In critical care patients, we reached a mean difference of 0.6 (95% limits of agreement: -2.3 to 3.5) mm and a feasibility of 88.1%. The clinical prototype of autoMAPSE achieved real-time performance. CONCLUSION: Automatic quantification of LV function had high feasibility in clinical settings. The agreement with manual references was comparable to inter-observer variability of clinical experts.


Asunto(s)
Puntos Anatómicos de Referencia , Ecocardiografía Transesofágica , Función Ventricular Izquierda , Humanos , Ecocardiografía Transesofágica/métodos , Función Ventricular Izquierda/fisiología , Puntos Anatómicos de Referencia/diagnóstico por imagen , Femenino , Masculino , Anciano , Persona de Mediana Edad , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Interpretación de Imagen Asistida por Computador/métodos
4.
IEEE J Biomed Health Inform ; 28(5): 2759-2768, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38442058

RESUMEN

Cardiac valve event timing plays a crucial role when conducting clinical measurements using echocardiography. However, established automated approaches are limited by the need of external electrocardiogram sensors, and manual measurements often rely on timing from different cardiac cycles. Recent methods have applied deep learning to cardiac timing, but they have mainly been restricted to only detecting two key time points, namely end-diastole (ED) and end-systole (ES). In this work, we propose a deep learning approach that leverages triplane recordings to enhance detection of valve events in echocardiography. Our method demonstrates improved performance detecting six different events, including valve events conventionally associated with ED and ES. Of all events, we achieve an average absolute frame difference (aFD) of maximum 1.4 frames (29 ms) for start of diastasis, down to 0.6 frames (12 ms) for mitral valve opening when performing a ten-fold cross-validation with test splits on triplane data from 240 patients. On an external independent test consisting of apical long-axis data from 180 other patients, the worst performing event detection had an aFD of 1.8 (30 ms). The proposed approach has the potential to significantly impact clinical practice by enabling more accurate, rapid and comprehensive event detection, leading to improved clinical measurements.


Asunto(s)
Aprendizaje Profundo , Ecocardiografía , Humanos , Ecocardiografía/métodos , Válvulas Cardíacas/diagnóstico por imagen , Válvulas Cardíacas/fisiología , Masculino , Interpretación de Imagen Asistida por Computador/métodos
5.
Ultrasound Med Biol ; 50(5): 661-670, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38341361

RESUMEN

OBJECTIVE: Valvular heart diseases (VHDs) pose a significant public health burden, and deciding the best treatment strategy necessitates accurate assessment of heart valve function. Transthoracic echocardiography (TTE) is the key modality to evaluate VHDs, but the lack of standardized quantitative measurements leads to subjective and time-consuming assessments. We aimed to use deep learning to automate the extraction of mitral valve (MV) leaflets and annular hinge points from echocardiograms of the MV, improving standardization and reducing workload in quantitative assessment of MV disease. METHODS: We annotated the MV leaflets and annulus points in 2931 images from 127 patients. We propose an approach for segmenting the annotated features using Attention UNet with deep supervision and weight scheduling of the attention coefficients to enforce saliency surrounding the MV. The derived segmentation masks were used to extract quantitative biomarkers for specific MV leaflet scallops throughout the heart cycle. RESULTS: Evaluation performance was summarized using a Dice score of 0.63 ± 0.14, annulus error of 3.64 ± 2.53 and leaflet angle error of 8.7 ± 8.3°. Leveraging Attention UNet with deep supervision robustness of clinically relevant metrics was improved compared with UNet, reducing standard deviations by 2.7° (angle error) and 0.73 mm (annulus error). We correctly identified cases of MV prolapse, cases of stenosis and healthy references from a clinical material using the derived biomarkers. CONCLUSION: Robust deep learning segmentation and tracking of MV morphology and motion is possible by leveraging attention gates and deep supervision, and holds promise for enhancing VHD diagnosis and treatment monitoring.


Asunto(s)
Aprendizaje Profundo , Ecocardiografía Tridimensional , Enfermedades de las Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Ecocardiografía/métodos , Biomarcadores , Ecocardiografía Transesofágica/métodos
6.
J Clin Monit Comput ; 38(2): 281-291, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38280975

RESUMEN

We have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery. First, we recorded a set of echocardiographic data, consisting of three consecutive beats of midesophageal two- and four-chamber views. We then altered the patient's hemodynamics by positioning them in anti-Trendelenburg and repeated the recordings. We measured MAPSE manually and used autoMAPSE in all available heartbeats and in four LV walls. To assess the agreement with manual measurements, we used a modified Bland-Altman analysis. To assess the precision of each method, we calculated the least significant change (LSC). Finally, to assess trending ability, we calculated the concordance rates using a four-quadrant plot. We found that autoMAPSE measured MAPSE in almost every set of two- and four-chamber views (feasibility 95%). It took less than a second to measure and average MAPSE over three heartbeats. AutoMAPSE had a low bias (0.4 mm) and acceptable limits of agreement (- 3.7 to 4.5 mm). AutoMAPSE was more precise than manual measurements if it averaged more heartbeats. AutoMAPSE had acceptable trending ability (concordance rate 81%) during hemodynamic alterations. In conclusion, autoMAPSE is feasible as an automatic tool for rapid and quantitative assessment of LV function, indicating its potential for hemodynamic monitoring.


Asunto(s)
Monitorización Hemodinámica , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Ecocardiografía Transesofágica , Disfunción Ventricular Izquierda/diagnóstico por imagen , Estudios Retrospectivos , Inteligencia Artificial , Válvula Mitral/diagnóstico por imagen
7.
Ultrasound Med Biol ; 50(4): 540-548, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38290912

RESUMEN

OBJECTIVE: The right ventricle receives less attention than its left counterpart in echocardiography research, practice and development of automated solutions. In the work described here, we sought to determine that the deep learning methods for automated segmentation of the left ventricle in 2-D echocardiograms are also valid for the right ventricle. Additionally, here we describe and explore a keypoint detection approach to segmentation that guards against erratic behavior often displayed by segmentation models. METHODS: We used a data set of echo images focused on the right ventricle from 250 participants to train and evaluate several deep learning models for segmentation and keypoint detection. We propose a compact architecture (U-Net KP) employing the latter approach. The architecture is designed to balance high speed with accuracy and robustness. RESULTS: All featured models achieved segmentation accuracy close to the inter-observer variability. When computing the metrics of right ventricular systolic function from contour predictions of U-Net KP, we obtained the bias and 95% limits of agreement of 0.8 ± 10.8% for the right ventricular fractional area change measurements, -0.04 ± 0.54 cm for the tricuspid annular plane systolic excursion measurements and 0.2 ± 6.6% for the right ventricular free wall strain measurements. These results were also comparable to the semi-automatically derived inter-observer discrepancies of 0.4 ± 11.8%, -0.37 ± 0.58 cm and -1.0 ± 7.7% for the aforementioned metrics, respectively. CONCLUSION: Given the appropriate data, automated segmentation and quantification of the right ventricle in 2-D echocardiography are feasible with existing methods. However, keypoint detection architectures may offer higher robustness and information density for the same computational cost.


Asunto(s)
Ecocardiografía , Ventrículos Cardíacos , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Ecocardiografía/métodos , Función Ventricular Derecha , Variaciones Dependientes del Observador , Tórax
8.
Eur Heart J Cardiovasc Imaging ; 25(3): 383-395, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37883712

RESUMEN

AIMS: Echocardiography is a cornerstone in cardiac imaging, and left ventricular (LV) ejection fraction (EF) is a key parameter for patient management. Recent advances in artificial intelligence (AI) have enabled fully automatic measurements of LV volumes and EF both during scanning and in stored recordings. The aim of this study was to evaluate the impact of implementing AI measurements on acquisition and processing time and test-retest reproducibility compared with standard clinical workflow, as well as to study the agreement with reference in large internal and external databases. METHODS AND RESULTS: Fully automatic measurements of LV volumes and EF by a novel AI software were compared with manual measurements in the following clinical scenarios: (i) in real time use during scanning of 50 consecutive patients, (ii) in 40 subjects with repeated echocardiographic examinations and manual measurements by 4 readers, and (iii) in large internal and external research databases of 1881 and 849 subjects, respectively. Real-time AI measurements significantly reduced the total acquisition and processing time by 77% (median 5.3 min, P < 0.001) compared with standard clinical workflow. Test-retest reproducibility of AI measurements was superior in inter-observer scenarios and non-inferior in intra-observer scenarios. AI measurements showed good agreement with reference measurements both in real time and in large research databases. CONCLUSION: The software reduced the time taken to perform and volumetrically analyse routine echocardiograms without a decrease in accuracy compared with experts.


Asunto(s)
Inteligencia Artificial , Disfunción Ventricular Izquierda , Humanos , Volumen Sistólico , Reproducibilidad de los Resultados , Función Ventricular Izquierda , Ecocardiografía/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen
9.
JACC Cardiovasc Imaging ; 16(12): 1516-1531, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37921718

RESUMEN

BACKGROUND: Myocardial deformation by echocardiographic strain imaging is a key measurement in cardiology, providing valuable diagnostic and prognostic information. Reference ranges for strain should be established from large healthy populations with minimal methodologic biases and variability. OBJECTIVES: The aim of this study was to establish echocardiographic reference ranges, including lower normal limits of global strains for all 4 cardiac chambers, by guideline-directed dedicated views from a large healthy population and to evaluate the influence of subject-specific characteristics on strain. METHODS: In total, 1,329 healthy participants from HUNT4Echo, the echocardiographic substudy of the 4th wave of the Trøndelag Health Study, were included. Echocardiographic recordings specific for each chamber were optimized according to current recommendations. Two experienced sonographers recorded all echocardiograms using GE HealthCare Vivid E95 scanners. Analyses were performed by experts using GE HealthCare EchoPAC. RESULTS: The reference ranges for left ventricular (LV) global longitudinal strain and right ventricular free-wall strain were -24% to -16% and -35% to -17%, respectively. Correspondingly, left atrial (LA) and right atrial (RA) reservoir strains were 17% to 49% and 17% to 59%. All strains showed lower absolute values with higher age, except for LA and RA contractile strains, which were higher. The feasibility for strain was overall good (LV 96%, right ventricular 83%, LA 94%, and RA 87%). All chamber-specific strains were associated with age, and LV strain was associated with sex. CONCLUSIONS: Reference ranges of strain for all cardiac chambers were established based on guideline-directed chamber-specific recordings. Age and sex were the most important factors influencing reference ranges and should be considered when using strain echocardiography.


Asunto(s)
Ecocardiografía , Tensión Longitudinal Global , Humanos , Valores de Referencia , Valor Predictivo de las Pruebas , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Función Ventricular Izquierda
10.
Artif Intell Med ; 144: 102646, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37783546

RESUMEN

Perioperative monitoring of cardiac function is beneficial for early detection of cardiovascular complications. The standard of care for cardiac monitoring performed by trained cardiologists and anesthesiologists involves a manual and qualitative evaluation of ultrasound imaging, which is a time-demanding and resource-intensive process with intraobserver- and interobserver variability. In practice, such measures can only be performed a limited number of times during the intervention. To overcome these difficulties, this study presents a robust method for automatic and quantitative monitoring of cardiac function based on 3D transesophageal echocardiography (TEE) B-mode ultrasound recordings of the left ventricle (LV). Such an assessment obtains consistent measurements and can produce a near real-time evaluation of ultrasound imagery. Hence, the presented method is time-saving and results in increased accessibility. The mitral annular plane systolic excursion (MAPSE), characterizing global LV function, is estimated by landmark detection and cardiac view classification of two-dimensional images extracted along the long-axis of the ultrasound volume. MAPSE estimation directly from 3D TEE recordings is beneficial since it removes the need for manual acquisition of cardiac views, hence decreasing the need for interference by physicians. Two convolutional neural networks (CNNs) were trained and tested on acquired ultrasound data of 107 patients, and MAPSE estimates were compared to clinically obtained references in a blinded study including 31 patients. The proposed method for automatic MAPSE estimation had low bias and low variability in comparison to clinical reference measures. The method accomplished a mean difference for MAPSE estimates of (-0.16±1.06) mm. Thus, the results did not show significant systematic errors. The obtained bias and variance of the method were comparable to inter-observer variability of clinically obtained MAPSE measures on 2D TTE echocardiography. The novel pipeline proposed in this study has the potential to enhance cardiac monitoring in perioperative- and intensive care settings.


Asunto(s)
Inteligencia Artificial , Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Ultrasonografía , Ecocardiografía/métodos , Función Ventricular Izquierda
11.
J Clin Med ; 12(20)2023 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-37892735

RESUMEN

Our objective was to compare long-term outcomes in patients with non-ST-elevation myocardial infarction (NSTEMI) and ST-elevation myocardial infarction (STEMI) between two time periods in Southern Norway. There are limited contemporary data comparing long-term follow-up after revascularization in the last decades. This prospective follow-up study consecutively included both NSTEMI and STEMI patients during two time periods, 2014-2015 and 2004-2009. Patients were followed up for a period of 5 years. The primary outcome was all-cause mortality after 1 and 5 years. A total of 539 patients with acute myocardial infarction (AMI), 316 with NSTEMI (234 included in 2014 and 82 included in 2007) and 223 with STEMI (160 included in 2014 and 63 included in 2004). Mortality after NSTEMI was high and remained unchanged during the two time periods (mortality rate at 1 year: 3.5% versus 4.9%, p = 0.50; and 5 years: 11.4% versus 14.6%, p = 0.40). Among STEMI patients, all-cause mortality at 1 year was reduced in 2014 compared to 2004 (1.3% versus 11.1%, p < 0.001; and 5 years: 7.0% versus 22.2%, p = 0.004, respectively). Time to coronary angiography in NSTEMI patients remained unchanged between 2014 and 2007 (28.2 h [IQR 18.1-46.3] versus 30.3 h [IQR 18.0-48.3], p = 0.20), while time to coronary angiography in STEMI patients was improved in 2014 compared with 2004 (2.8 h [IQR 2.0-4.8] versus 21.7 h [IQR 5.4-27.1], p < 0.001), respectively. During one decade of AMI treatment, mortality in patients with NSTEMI remained unchanged while mortality in STEMI patients decreased, both at 1 and 5 years.

12.
Scand J Med Sci Sports ; 33(12): 2499-2508, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37658830

RESUMEN

BACKGROUND: Plasma concentrations of cardiac troponins increase in healthy individuals after strenuous training, but the response to lower exercise intensities has not been characterized. AIM: To determine whether exercise at moderate intensity significantly increases plasma cardiac troponins measured with different assays in healthy recreational athletes. METHODS: Twenty-four self-reported healthy volunteers were instructed to complete three 60-min bouts of treadmill running at variable intensities: High-intensity training (HIT) including a maximal exercise test and an anaerobic threshold test followed by training at 80%-95% of maximum heart rate (HRmax ), Moderate-intensity training (MIT) at 60%-75% of HRmax , and Low-intensity training (LIT) at 45%-55% of HRmax . Blood samples were collected before and at 2, 4, and 6 h after HIT and 4 h after MIT and LIT. Troponin I and T were measured in plasma samples with assays from Abbot, Siemens, and Roche. RESULTS: Plasma troponins measured with all assays were significantly increased compared to baseline after HIT but not after LIT. After HIT, the fraction of all participants with one or more values above the assay-specific 99th percentiles ranged from 13% to 61%. The biomarker criteria for acute myocardial injury were met after HIT for troponin T in 75% of female participants having no clinical evidence of coronary artery disease. CONCLUSION: High-intensity, but not moderate- or low-intensity, training for 60 min induced a potentially clinically significant increase in plasma cardiac troponins in healthy volunteers. Results exceeding the population 99th percentiles were most frequent with the troponin T assay.


Asunto(s)
Carrera , Troponina I , Humanos , Femenino , Troponina T , Proyectos Piloto , Prueba de Esfuerzo , Voluntarios Sanos
14.
Quant Imaging Med Surg ; 13(7): 4603-4617, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37456280

RESUMEN

Background: An aberration correction algorithm has been implemented and demonstrated in an echocardiographic clinical trial using two-dimensional (2D) imaging. The method estimates and compensates arrival time errors between different sub-aperture processor (SAP) signals in a matrix array probe. Methods: Five standard views of channel data cineloops were recorded from 22 patients (11 male and 11 female) resulting in a total of 116 cineloops. The channel data were processed with and without the aberration correction algorithm, allowing for side-by-side comparison of images processed from the same channel data cineloops. Results: The aberration correction algorithm improved image quality, as quantified by a coherence metric, in all 7,380 processed frames. In a blinded and left-right-randomized side-by-side evaluation, four cardiologists (two experienced and two in training) preferred the aberration corrected cineloops in 97% of the cases. The clinicians reported that the corrected cineloops appeared sharper with better contrast and less noise. Many structures like valve leaflets, chordae, endocardium, and endocardial borders appeared narrower and more clearly defined in the aberration corrected images. An important finding is that aberration correction improves contrast between the endocardium and ventricle cavities for every processed image. The gain difference was confirmed by the cardiologists in their feedback and quantified with a median global gain difference estimate between the aberration-corrected and non-corrected images of 1.2 dB. Conclusions: The study shows the potential value of aberration correction in clinical echocardiography. Systematic improvement of images acquired with state-of-art equipment was observed both with quantitative metrics of image quality and clinician preference.

15.
J Am Soc Echocardiogr ; 36(7): 788-799, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36933849

RESUMEN

AIMS: Assessment of left ventricular (LV) function by echocardiography is hampered by modest test-retest reproducibility. A novel artificial intelligence (AI) method based on deep learning provides fully automated measurements of LV global longitudinal strain (GLS) and may improve the clinical utility of echocardiography by reducing user-related variability. The aim of this study was to assess within-patient test-retest reproducibility of LV GLS measured by the novel AI method in repeated echocardiograms recorded by different echocardiographers and to compare the results to manual measurements. METHODS: Two test-retest data sets (n = 40 and n = 32) were obtained at separate centers. Repeated recordings were acquired in immediate succession by 2 different echocardiographers at each center. For each data set, 4 readers measured GLS in both recordings using a semiautomatic method to construct test-retest interreader and intrareader scenarios. Agreement, mean absolute difference, and minimal detectable change (MDC) were compared to analyses by AI. In a subset of 10 patients, beat-to-beat variability in 3 cardiac cycles was assessed by 2 readers and AI. RESULTS: Test-retest variability was lower with AI compared with interreader scenarios (data set I: MDC = 3.7 vs 5.5, mean absolute difference = 1.4 vs 2.1, respectively; data set II: MDC = 3.9 vs 5.2, mean absolute difference = 1.6 vs 1.9, respectively; all P < .05). There was bias in GLS measurements in 13 of 24 test-retest interreader scenarios (largest bias, 3.2 strain units). In contrast, there was no bias in measurements by AI. Beat-to-beat MDCs were 1,5, 2.1, and 2.3 for AI and the 2 readers, respectively. Processing time for analyses of GLS by the AI method was 7.9 ± 2.8 seconds. CONCLUSION: A fast AI method for automated measurements of LV GLS reduced test-retest variability and removed bias between readers in both test-retest data sets. By improving the precision and reproducibility, AI may increase the clinical utility of echocardiography.


Asunto(s)
Aprendizaje Profundo , Disfunción Ventricular Izquierda , Humanos , Reproducibilidad de los Resultados , Inteligencia Artificial , Función Ventricular Izquierda , Ecocardiografía/métodos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Volumen Sistólico
16.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-36945146

RESUMEN

AIMS: Atrial fibrillation (AF) is the most common arrhythmia worldwide. The AF is associated with severe mortality, morbidity, and healthcare costs, and guidelines recommend screening people at risk. However, screening methods and organization still need to be clarified. The current study aimed to assess the feasibility of a fully digital self-screening procedure and to assess the prevalence of undetected AF using a continuous patch electrocardiogram (ECG) monitoring system. METHODS AND RESULTS: Individuals ≥65 years old with at least one additional risk factor for stroke from the general population of Norway were invited to a fully digital continuous self-screening for AF using a patch ECG device (ECG247 Smart Heart Sensor). Participants self-reported clinical characteristics and usability online, and all participants received digital feedback of their results. A total of 2118 individuals with a mean CHA2DS2-VASc risk score of 2.6 (0.9) were enrolled in the study [74% women; mean age 70.1 years (4.2)]. Of these, 1849 (87.3%) participants completed the ECG self-screening test, while 215 (10.2%) did not try to start the test and 54 (2.5%) failed to start the test. The system usability score was 84.5. The mean ECG monitoring time was 153 h (87). Atrial fibrillation was detected in 41 (2.2%) individuals. CONCLUSION: This fully digitalized self-screening procedure for AF demonstrated excellent feasibility. The number needed to screen was 45 to detect one unrecognized case of AF in subjects at risk for stroke. Randomized studies with long-term follow-up are needed to assess whether self-screening for AF can reduce the incidence of AF-related complications. CLINICAL TRIALS: NCT04700865.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Femenino , Anciano , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/complicaciones , Electrocardiografía , Factores de Riesgo , Accidente Cerebrovascular/prevención & control , Atención a la Salud
17.
Int J Cardiovasc Imaging ; 39(4): 757-766, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36715881

RESUMEN

PURPOSE: Identification of regional dysfunction is important for early risk stratification in patients with suspected non-ST-elevation myocardial infarction (NSTEMI). Strain echocardiography enables quantification of segmental myocardial deformation. However, the clinical use is hampered by time-consuming manual measurements. We aimed to evaluate whether an in-house developed software for automated analysis of segmental myocardial deformation based on tissue Doppler imaging (TDI) could predict coronary occlusion in patients with suspected NSTEMI. METHODS: Eighty-four patients with suspected NSTEMI were included in the analysis. Echocardiography was performed at admission. Strain, strain rate and post-systolic shortening index (PSI) were analyzed by the automated TDI-based tool and the ability to predict coronary occlusion was assessed. For comparison, strain measurements were performed both by manual TDI-based analyses and by semi-automatic speckle tracking echocardiography (STE). All patients underwent coronary angiography. RESULTS: Seventeen patients had an acute coronary occlusion. Global strain and PSI by STE were able to differentiate occluded from non-occluded culprit lesions (respectively - 15.0% vs. -17.1%, and 8.1% vs. 5.1%, both p-values < 0.05) and identify patients with an acute coronary occlusion (AUC 0.66 for both strain and PSI). Measurements of strain, strain rate and PSI based on TDI were not significantly different between occluded and non-occluded territories. CONCLUSION: Automated measurements of myocardial deformation based on TDI were not able to identify acute coronary occlusion in patients with suspected NSTEMI. However, this study confirms the potential of strain by STE for early risk stratification in patients with chest pain.


Asunto(s)
Oclusión Coronaria , Infarto del Miocardio sin Elevación del ST , Humanos , Infarto del Miocardio sin Elevación del ST/diagnóstico por imagen , Infarto del Miocardio sin Elevación del ST/terapia , Oclusión Coronaria/complicaciones , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Vasos Coronarios , Valor Predictivo de las Pruebas , Corazón
18.
Ultrasound Med Biol ; 49(1): 333-346, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36280443

RESUMEN

Measurements of cardiac function such as left ventricular ejection fraction and myocardial strain are typically based on 2-D ultrasound imaging. The reliability of these measurements depends on the correct pose of the transducer such that the 2-D imaging plane properly aligns with the heart for standard measurement views and is thus dependent on the operator's skills. We propose a deep learning tool that suggests transducer movements to help users navigate toward the required standard views while scanning. The tool can simplify echocardiography for less experienced users and improve image standardization for more experienced users. Training data were generated by slicing 3-D ultrasound volumes, which permits simulation of the movements of a 2-D transducer. Neural networks were further trained to calculate the transducer position in a regression fashion. The method was validated and tested on 2-D images from several data sets representative of a prospective clinical setting. The method proposed the adequate transducer movement 75% of the time when averaging over all degrees of freedom and 95% of the time when considering transducer rotation solely. Real-time application examples illustrate the direct relation between the transducer movements, the ultrasound image and the provided feedback.


Asunto(s)
Ecocardiografía Tridimensional , Función Ventricular Izquierda , Volumen Sistólico , Reproducibilidad de los Resultados , Estudios Prospectivos , Ecocardiografía/métodos
19.
Artículo en Inglés | MEDLINE | ID: mdl-36315529

RESUMEN

Accurate quantification of cardiac valve regurgitation jets is fundamental for guiding treatment. Cardiac ultrasound is the preferred diagnostic tool, but current methods for measuring the regurgitant volume (RVol) are limited by low accuracy and high interobserver variability. Following recent research, quantitative estimators of orifice size and RVol based on high frame rate 3-D ultrasound have been proposed, but measurement accuracy is limited by the wide point spread function (PSF) relative to the orifice size. The aim of this article was to investigate the use of deep learning to estimate both the orifice size and the RVol. A simulation model was developed to simulate the power-Doppler images of blood flow through orifices with different geometries. A convolutional neural network (CNN) was trained on 30 000 image pairs. The network was used to reconstruct orifices from power-Doppler data, which facilitated estimators for regurgitant orifice areas and flow volumes. We demonstrate that the network improves orifice shape reconstruction, as well as the accuracy of orifice area and flow volume estimation, compared with a previous approach based on thresholding of the power-Doppler signal (THD), and compared with spatially invariant deconvolution (DC). Our approach reduces the area estimation error on simulations: (THD: 13.2 ± 9.9 mm2, DC: 12.8 ± 15.8 mm2, and ours: 3.5 ± 3.2 mm2). In a phantom experiment, our approach reduces both area estimation error (THD: 10.4 ± 8.4 mm2, DC: 10.98 ± 8.17, and ours: 9.9 ± 6.0 mm2) and flow rate estimation error (THD: 20.3 ± 9.9 ml/s, DC: 18.14 ± 13.01 ml/s, and ours: 7.1 ± 10.6 ml/s). We also demonstrate in vivo feasibility for six patients with aortic insufficiency, compared with standard echocardiography and magnetic resonance references.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Aprendizaje Profundo , Ultrasonografía Doppler , Humanos , Velocidad del Flujo Sanguíneo/fisiología , Ecocardiografía , Hemodinámica , Ultrasonografía , Imagenología Tridimensional
20.
BMC Emerg Med ; 22(1): 57, 2022 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-35366802

RESUMEN

BACKGROUND: Following the spread of the Covid-19 pandemic in 2020, reports emerged on decreasing emergency department (ED) visits in many countries. Patients experiencing chest pain was no exception. The aim of the current study was to describe how the Covid-19 pandemic and the subsequential lockdown impacted the chest pain population in a Norwegian ED. METHODS: All patients presenting to the ED with chest pain during the study period were included. Data were collected retrospectively from the time period January 6th to August 30th, 2020, and compared to the corresponding period in 2019, assessing variations in the number of ED visits, severity, gender, and age. RESULTS: Fewer patients with chest pain were seen in the ED following the national lockdown in Norway, compared to the corresponding 2019 period (week 13: 38% fewer; weeks 11-27: 16% fewer). By week 28, the rate normalized compared to 2019 levels. There was a relative increase in lower acuity patients among these patients, while fewer moderate acuity patients were seen. During the initial period following lockdown, the median age was lower compared to the corresponding 2019 period (58 years (IQR 25) vs 62 years (IQR 24), respectively). Admissions due to acute coronary syndromes (ACS) remained proportionally stable. CONCLUSIONS: Succeeding the Covid-19 outbreak and the subsequent national lockdown in Norway, fewer chest pain patients presented to the ED. Paradoxically, the patients seemed to be less severely ill and were on average younger compared to 2019 data. However, the proportion of patients admitted with ACS was stable during this period. This could imply that some patients may have failed to seek medical advice despite experiencing a myocardial infarction.


Asunto(s)
COVID-19 , Adulto , COVID-19/epidemiología , Dolor en el Pecho/epidemiología , Control de Enfermedades Transmisibles , Servicio de Urgencia en Hospital , Humanos , Pandemias , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...