Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
World J Orthop ; 10(7): 292-298, 2019 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-31360644

RESUMEN

BACKGROUND: Intraosseous lipoma is a rare benign lesion, commonly affecting the os calcis. Its pathogenesis and natural history are not fully understood, and its management remains controversial. CASE SUMMARY: A 56-year-old male complaining of heel pain was diagnosed with an os calcis lipoma. The lesion was treated with curettage and it was filled with impacted allograft and demineralized bone matrix. Histological examination confirmed the above diagnosis. Six months postoperatively, the patient returned to recreational long-distance running. Repeated computed tomography scanning, up to five years postoperatively, showed almost complete resorption of the graft over time. CONCLUSION: The treatment of an os calcis lipoma should be individualized, depending on the symptoms, the location and size of the lesion. Surgeons, electing to proceed with bone grafting, should consider the probability of bone graft resorption.

2.
Hip Pelvis ; 28(4): 249-253, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28097115

RESUMEN

A case of a female patient with local and systemic complications of metallosis, following catastrophic wear of a revised hip arthroplasty, is presented. The patient had a history of a fractured ceramic-on-ceramic implant, exchanged with a metal-on-polyethylene prosthesis. Systemic complications included sarcoidosis-like reactions, presenting as granulomatous lung disease, along with chorioretinitis, erythema nodosum, and cardiomyopathy. High local and circulating cobalt and chromium levels established the diagnosis. The patient underwent extensive debridement and implant revision. One year postoperatively, she had no respiratory symptoms or functional impairment. Local and systemic complications of metallosis after hip arthroplasty should be promptly recognized and treated operatively.

3.
J Biomech ; 40(6): 1340-9, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-16824529

RESUMEN

An effective lubrication can significantly reduce wear of metal-on-metal artificial hip joints. The improvement of the lubrication can be achieved through the optimisation of the bearing geometry in terms of a small clearance and/or the structural support such as a polyethylene backing underneath a metallic bearing in a sandwich acetabular cup form. The separate effects of these two factors on fluid film lubrication of 28 mm diameter metal-on-metal total hip joints under walking conditions were numerically investigated in this paper. The results show that a larger lubricant film due to the polyethylene backing can be significantly enhanced by the transient squeeze-film action, particularly during the stance phase, and a similar lubricant film can be developed for both the monolithic cup relying on the smaller clearance and the sandwich cup benefiting from the polyethylene backing. Both cup systems can function in a wide range of lubrication regimes, covering both mixed and fluid film, under the current design and manufacture conditions.


Asunto(s)
Diseño Asistido por Computadora , Diseño de Equipo/métodos , Análisis de Falla de Equipo/métodos , Prótesis de Cadera , Metales/química , Modelos Teóricos , Simulación por Computador , Elasticidad , Fricción , Lubrificación , Viscosidad
4.
Acta Orthop Belg ; 72(2): 226-8, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16768272

RESUMEN

We report a complication of contemporary cementing technique in total hip arthroplasty, that is, extensive retrograde filling with polymethylmethacrylate cement of the nutrient artery of the femur.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos/efectos adversos , Fémur/irrigación sanguínea , Polimetil Metacrilato/efectos adversos , Vasa Vasorum , Femenino , Humanos , Persona de Mediana Edad , Complicaciones Posoperatorias , Radiografía , Vasa Vasorum/diagnóstico por imagen
5.
Acta Orthop ; 76(3): 341-6, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16156461

RESUMEN

BACKGROUND: The diagnosis of prosthetic infection remains a challenge, as no test is 100% sensitive and 100% specific. Recent advances in molecular biology have enabled the detection of infection in culture negative cases. PATIENTS AND METHODS: We evaluated the effectiveness of polymerase chain reaction (PCR) in detecting infection in failed joint replacements prospectively in 91 consecutive patients (92 prosthetic joints) undergoing revision total hip or knee arthroplasty. Synovial fluid was collected intraoperatively and examined by broad-range PCR assay for detection of bacterial DNA. The clinical diagnosis of infection was based on the results of blood tests, preoperative joint aspiration, culture and histology of multiple intraoperative tissue samples, as well as the surgeon's assessment. 12 joints (13%) were infected, but the PCR was positive in 32 cases. The sensitivity of the technique was 92%, the specificity 74%, the accuracy 76%, the positive predictive value 34%, and the negative predictive value was 98%. INTERPRETATION: The PCR technique cannot be recommended for the routine detection of prosthetic infection. The large number of false positive results may represent sample contamination, or bacterial presence related to low-virulence organisms, low bacterial load, or a strong host immune response.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Infecciones Bacterianas/diagnóstico , Reacción en Cadena de la Polimerasa , Falla de Prótesis , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Bacterianas/microbiología , ADN Bacteriano/análisis , Reacciones Falso Positivas , Humanos , Reacción en Cadena de la Polimerasa/normas , Valor Predictivo de las Pruebas , Estudios Prospectivos , Infecciones Relacionadas con Prótesis/microbiología , Reoperación , Sensibilidad y Especificidad , Líquido Sinovial/microbiología
6.
Orthop Clin North Am ; 36(2): 125-34, vii, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15833450

RESUMEN

Metal-on-metal hip resurfacing, a significant recent development in hip arthroplasty, preserves proximal femoral bone stock, optimizes stress transfer to the proximal femur, and offers inherent stability and optimal range of movement. The results of hip resurfacing in the 1970s and 1980s were disappointing, and the procedure was largely abandoned by the mid-1980s. The renaissance of metal-on-metal articulations for total hip arthroplasty has enabled the introduction of new hip resurfacings, and many implant manufacturers have introduced such systems. Early results are encouraging, and complications commonly seen in the 1970s and 1980s, such as early implant loosening and femoral neck fracture, are rare. Background research and better understanding of implant failure suggest that current hip resurfacing technology has developed beyond that of an experimental procedure.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Prótesis de Cadera , Infecciones Relacionadas con Prótesis/prevención & control , Artroplastia de Reemplazo de Cadera/efectos adversos , Materiales Biocompatibles , Seguridad de Equipos , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Reoperación , Sensibilidad y Especificidad
7.
Orthop Clin North Am ; 36(2): 135-42, vii, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15833451

RESUMEN

Large-diameter metal-on-metal articulations may provide an opportunity for wear reduction in total hip implants because earlier studies have shown that the formation of a fluid film that completely separates the bearing surfaces is theoretically possible. In such a lubrication mode and under ideal conditions, there is theoretically no amount of wear. Studies have suggested that the two primary parameters controlling the lubrication mode are the diameter and the clearance of the articulation. The goal of the present study was to experimentally investigate the influence of these two parameters on the wear behavior of large-diameter metal-on-metal articulations pertaining to resurfacing hip implants. The results of this in vitro investigation showed that longer running-in periods and higher amounts of running-in wear were associated with larger clearances.


Asunto(s)
Diseño de Equipo , Prótesis de Cadera , Metales , Fenómenos Biomecánicos , Fuerza Compresiva , Análisis de Falla de Equipo , Seguridad de Equipos , Humanos , Técnicas In Vitro , Inestabilidad de la Articulación/prevención & control , Ensayo de Materiales , Polietilenos , Estrés Mecánico , Propiedades de Superficie
8.
Acta Orthop Belg ; 70(5): 429-34, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15587031

RESUMEN

The results in a series of 42 patients with 48 impending or complete pathological femur fractures stabilised with the Long Gamma nail (Howmedica-Osteonics, Rutherford, NJ,USA) are presented. Twenty two impending and 26 completed pathological femoral fractures treated between 1995 and 1999 were retrospectively analysed. The mean age of the patients was 65.7 yrs (range: 40 to 88). All patients were treated with an 11-mm diameter Long Gamma Nail, inserted through a 5-cm incision proximal to the greater trochanter using the antegrade reaming technique. The mean surgical time was 98 minutes (range: 65 to 225). Reliable stability was achieved in all cases and pain relief was excellent. Complications included 2 superficial and 1 deep wound infections, 4 chest infections, 2 urinary tract infections, and 2 deaths in the recovery. Implant failure occurred in one patient and needed revision to a long stemmed total hip prosthesis. The Long Gamma nail offers the advantage of a technically less demanding percutaneous insertion through the tip of the greater trochanter, secure proximal femoral fixation and the ability to allow immediate or early weight-bearing ambulation. Because of these advantages, we recommend the use of the Long Gamma nail for stabilisation of pathologic and impending pathologic fractures of the femur.


Asunto(s)
Tornillos Óseos , Fracturas del Cuello Femoral/cirugía , Fijación Intramedular de Fracturas/instrumentación , Fracturas Espontáneas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Diseño de Equipo , Seguridad de Equipos , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fracturas del Cuello Femoral/diagnóstico por imagen , Estudios de Seguimiento , Fijación Intramedular de Fracturas/métodos , Curación de Fractura/fisiología , Fracturas Espontáneas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Radiografía , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Resultado del Tratamiento
9.
Acta Orthop Belg ; 70(4): 349-54, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15481420

RESUMEN

A new technique is described for dressing of surgical wounds in total knee arthroplasty that is a combination of a semi-permeable dressing and suction drainage. This technique has been used in 100 consecutive cases and drainage was collected in 92. The average volume was 198 ml (range 30 to 850 ml). There was no superficial or deep sepsis. Haematoma formation causing moderate soft tissue tension and some patient discomfort was noted in 9 knees. This form of postoperative wound management retains the nursing and hygiene advantages of deep suction drainage, whilst avoiding the patient discomfort and potential complication possibilities associated with deep internal drainage.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Apósitos Oclusivos , Infección de la Herida Quirúrgica/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Drenaje/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Dimensión del Dolor , Cuidados Posoperatorios/métodos , Estudios Prospectivos , Radiografía , Recuperación de la Función , Medición de Riesgo , Succión , Resultado del Tratamiento
10.
Knee Surg Sports Traumatol Arthrosc ; 12(4): 307-10, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-14530854

RESUMEN

We report the failure of a femoral component in a unicompartmental knee replacement 6 years after implantation. The implant fractured 15 mm from the anterior tip, and scanning electron microscopy confirmed fatigue to be the cause of failure. The clinical and laboratory findings are presented, and the causes and implications of this mode of implant failure are discussed.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Falla de Prótesis , Artroplastia de Reemplazo de Rodilla/métodos , Biopsia con Aguja , Estudios de Seguimiento , Humanos , Inmunohistoquímica , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Radiografía , Reoperación , Medición de Riesgo , Resultado del Tratamiento
11.
Acta Orthop Scand ; 74(4): 397-403, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-14521288

RESUMEN

We report a retrospective clinical and radiographic review of 107 consecutive primary total hip replacements, using the cemented Howse II prosthesis. The review concentrates on the long-term performance of the acetabular cup, which was designed with a cylindrical titanium metal backing and a polyethylene liner. In all the hips in the series, this cup was used with a modular titanium straight femoral stem and a 32-mm diameter titanium head. At a mean follow-up of 9.8 (7-11) years, 28 hips had already been revised and 10 others were recognized as clinical or radiographic failures. The indication for revision in 26 of the hips was aseptic loosening and the mean time to revision was 7.2 (3.7-10.9) years This metal-backed cup has only 42% survival at 10 years, which seems to be related to certain of its design features. These include an inadequate thickness of polyethylene sterilized by gamma irradiation in air, a lack of mechanical bonding between the liner and its metal shell, and the high wear rate from the use of a 32-mm titanium femoral head.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Cementación/métodos , Articulación de la Cadera/cirugía , Prótesis de Cadera , Diseño de Prótesis , Titanio , Acetábulo , Adulto , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/instrumentación , Materiales Biocompatibles Revestidos , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Masculino , Ensayo de Materiales , Persona de Mediana Edad , Dimensión del Dolor , Satisfacción del Paciente , Valor Predictivo de las Pruebas , Probabilidad , Modelos de Riesgos Proporcionales , Falla de Prótesis , Radiografía , Rango del Movimiento Articular/fisiología , Estudios Retrospectivos , Resultado del Tratamiento , Reino Unido
12.
Arch Orthop Trauma Surg ; 123(2-3): 128-31, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12721694

RESUMEN

We report the case of a wheelchair-bound rheumatoid Jehovah's Witness who underwent rapid sequence, staged, simultaneous ipsilateral hip and knee replacements. Using perioperative erythropoietin and postoperative blood salvage, all four joints were reconstructed without homologous blood transfusion. One year following surgery, the patient has achieved an independent functional status, and all four replaced joints remain painless.


Asunto(s)
Artritis Reumatoide/cirugía , Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Testigos de Jehová , Profilaxis Antibiótica , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Rodilla/métodos , Pérdida de Sangre Quirúrgica , Transfusión de Sangre Autóloga/métodos , Femenino , Humanos , Persona de Mediana Edad
13.
Int Orthop ; 26(6): 356-60, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12466868

RESUMEN

Between 1991 and 1994, 147 patients (154 hips) underwent a primary cemented total hip replacement using the Ultima ti-alloy, collarless, double-tapered stem and a UHMWPE cup. The average age at operation was 66.4 years. Ninety-one patients (97 hips) were available for review with an average follow-up of 76 months. The Harris hip score had improved from pre-operative average of 43.1 (12.5-65.0) to the latest score of 88.9 (67.5-100). There were 11 revisions in total, eight of which were for aseptic stem loosening. The results of Kaplan-Meier survival analysis, based on stem revision for aseptic loosening as an end-point, was 92% at 8 years. Early stem migration analysis at 2 years was possible in 114 cases using digitised radiographs analysed by the EBRA method. Sixty-three stems had not migrated and 35 migrated less than 2 mm with only one of these ending in failure. Sixteen stems showed early migration of more than 2 mm and five of these failed. Early stem migration is predictive of stem failure. Osteolytic lesions occurred in 12 femurs and four of these stems failed.


Asunto(s)
Aleaciones , Artroplastia de Reemplazo de Cadera/efectos adversos , Migración de Cuerpo Extraño/etiología , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Titanio , Adulto , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles , Cementos para Huesos , Cementación/métodos , Femenino , Fémur/cirugía , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Cadera/cirugía , Estudios Prospectivos , Reoperación , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...