Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Gynecol Endocrinol ; 36(6): 513-520, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32064971

RESUMEN

The objective was to assess efficacy and safety of a combined oral contraceptive containing ethinylestradiol (EE) and levonorgestrel (LNG) in an extended-cycle vs. a conventional-cycle regimen. This first European randomized, active controlled, open, prospective, parallel-group trial was conducted in 48 German gynecological centers. 1,314 healthy, sexually active women aged 18-35 years were randomized. With an unadjusted PI of 0.483 (upper 95% CI: 1.237), the extended-cycle regimen fulfilled the contraceptive efficacy of EE/LNG, the requirements of the European Medicines Agency. The mean total number of bleeding days per year was significantly lower in the extended-cycle vs. the conventional-cycle regimen. Analyses of bleeding patterns showed a reduced total number of bleeding/spotting days per year in the extended-cycle vs. the conventional-cycle regimen. Cycle-associated complaints and AE were comparable in both groups. Both regimens were very well accepted. The extended-cycle regimen of EE/LNG was effective and well tolerated resulting in a lower number of bleeding days and a favorable bleeding pattern compared to the conventional-cycle regimen.


Asunto(s)
Anticonceptivos Orales Combinados/administración & dosificación , Etinilestradiol/administración & dosificación , Levonorgestrel/administración & dosificación , Ciclo Menstrual/efectos de los fármacos , Adolescente , Adulto , Anticonceptivos Orales Combinados/efectos adversos , Esquema de Medicación , Combinación de Medicamentos , Etinilestradiol/efectos adversos , Femenino , Alemania , Humanos , Levonorgestrel/efectos adversos , Ciclo Menstrual/fisiología , Menstruación/efectos de los fármacos , Menstruación/fisiología , Resultado del Tratamiento , Adulto Joven
2.
Arzneimittelforschung ; 58(4): 168-73, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18540478

RESUMEN

The objective of this post-marketing surveillance (PMS) was the evaluation of efficacy, tolerability, and acceptance of the advanced formoterol (CAS 73573-87-2) multidose dry powder inhaler (MDPI) Formatris 6 microg/12 microg Novolizer (FN) in asthmatic patients (n = 5219) in a real-life setting. A total of 2727 patients (52%) received concomitant anti-inflammatory treatment exclusively via a budesonide Novolizer (BN). Efficacy of the FN was assessed by measurement of peak expiratory flow (PEF) and forced expiratory volume in one second (FEV1) before and after 4 weeks of therapy. The severity of cough, wheezing, diurnal dyspnea, nocturnal dyspnea and dyspnea on physical effort were assessed on a four-point scale, and a severity sum score was calculated. The patients' satisfaction with the multiple feedback mechanisms, handling and safety of the FN was also assessed. The physicians judged the patient compliance and any improved inhalation reassurance due to FN control mechanisms in comparison with other inhalation systems. FN use (n = 2727) was associated with improved lung function. After 4 weeks, PEF increased by 26% (from 270 L/min to 340 L/min) and the median FEV1 increased by 24% (from 2.1 L to 2.6 L). The median severity sum score decreased from 8.0 before therapy to 3.0 after therapy. Most patients assessed the control mechanisms and safety functions of the FN as 'very good' or 'good'. 96% of patients were satisfied with the optical control mechanism, 92% with the acoustic mechanism, 70% with the taste feedback, 89% with the dose counter and 76% with the overdose prevention. The majority of patients (95%) confirmed that the multiple feedback mechanisms reassured correct drug intake, with 83% rating the FN as 'much better' or 'better' than previously used inhalers. The physicians confirmed that in contrast to previously used inhalers the FN ensured correct inhalation in 87% of all patients. The physicians were satisfied with the patients' compliance in 95% of cases. Finally, the majority of patients (98%) were highly satisfied with the correct inhalation feedback mechanism. 94% of patients intended to continue FN therapy beyond the study. Overall, FN reduced the patients' asthma symptoms and improved lung function, possibly due to improved compliance with therapy. The correct inhalation feedback mechanisms and safety functions of the device were assessed very positively by patients and were considered by the physicians to be important in improving inhalation reassurance and patient compliance.


Asunto(s)
Antiasmáticos/administración & dosificación , Antiasmáticos/uso terapéutico , Asma/tratamiento farmacológico , Etanolaminas/administración & dosificación , Etanolaminas/uso terapéutico , Adolescente , Corticoesteroides/administración & dosificación , Corticoesteroides/uso terapéutico , Adulto , Anciano , Anciano de 80 o más Años , Antiasmáticos/efectos adversos , Asma/fisiopatología , Niño , Tos/etiología , Tos/fisiopatología , Disnea/etiología , Disnea/fisiopatología , Etanolaminas/efectos adversos , Femenino , Volumen Espiratorio Forzado/efectos de los fármacos , Fumarato de Formoterol , Humanos , Masculino , Persona de Mediana Edad , Nebulizadores y Vaporizadores , Aceptación de la Atención de Salud , Ápice del Flujo Espiratorio/efectos de los fármacos , Vigilancia de Productos Comercializados , Pruebas de Función Respiratoria , Ruidos Respiratorios/etiología , Ruidos Respiratorios/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA