Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Diabetes Technol Ther ; 24(2): 113-119, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34524003

RESUMEN

Background: The MiniMed™ 780G system includes an advanced hybrid closed loop (AHCL) algorithm that provides both automated basal and correction bolus insulin delivery. The preliminary performance of the system in real-world settings was evaluated. Methods: Data uploaded from August 2020 to March 2021 by individuals living in Belgium, Finland, Italy, the Netherlands, Qatar, South Africa, Sweden, Switzerland, and the United Kingdom were aggregated and retrospectively analyzed to determine the mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR), and above (TAR) glycemic ranges, system use, and insulin consumption in users having ≥10 days of sensor glucose (SG) data after initiating AHCL. The impact of initiating AHCL was evaluated in a subgroup of users also having ≥10 days of SG data, before AHCL initiation. Results: Users (N = 4120) were observed for a mean of 54 ± 32 days. During this time, they spent a mean of 94.1% ± 11.4% of the time in AHCL and achieved a mean GMI of 6.8% ± 0.3%, TIR of 76.2% ± 9.1%, TBR <70 of 2.5% ± 2.1%, and TAR >180 of 21.3% ± 9.4%, after initiating AHCL. There were 77.3% and 79.0% of users who achieved a TIR >70% and a GMI of <7.0%, respectively. Users for whom comparison with pre-AHCL was possible (N = 812) reduced their GMI by 0.4% ± 0.4% (P = 0.005) and increased their TIR by 12.1% ± 10.5% (P < 0.0001), post-AHCL initiation. More users achieved the glycemic treatment goals of GMI <7.0% (37.6% vs. 75.2%, P < 0.0001) and TIR >70% (34.6% vs. 74.9%, P < 0.0001) when compared with pre-AHCL initiation. Conclusion: Most MiniMed 780G system users achieved TIR >70% and GMI <7%, while minimizing hypoglycemia, in a real-world condition.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Estudios Retrospectivos
2.
Diabetes Obes Metab ; 23(8): 1942-1949, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33961340

RESUMEN

AIM: To evaluate the real-world performance of the MiniMed 670G system in Europe, in individuals with diabetes. MATERIALS AND METHODS: Data uploaded from October 2018 to July 2020 by individuals living in Europe were aggregated and retrospectively analysed. The mean glucose management indicator (GMI), percentage of time spent within (TIR), below (TBR) and above (TAR) glycaemic ranges, system use and insulin consumed in users with 10 or more days of sensor glucose data after initial Auto Mode start were determined. Another analysis based on suboptimally (GMI > 8.0%) and well-controlled (GMI < 7.0%) glycaemia pre-Auto Mode initiation was also performed. RESULTS: Users (N = 14 899) spent a mean of 81.4% of the time in Auto Mode and achieved a mean GMI of 7.0% ± 0.4%, TIR of 72.0% ± 9.7%, TBR less than 3.9 mmol/L of 2.4% ± 2.1% and TAR more than 10 mmol/L of 25.7% ± 10%, after initiating Auto Mode. When compared with pre-Auto Mode initiation, GMI was reduced by 0.3% ± 0.4% and TIR increased by 9.6% ± 9.9% (P < .0001 for both). Significantly improved glycaemic control was observed irrespective of pre-Auto Mode GMI levels of less than 7.0% or of more than 8.0%. While the total daily dose of insulin increased for both groups, a greater increase was observed in the latter, an increase primarily due to increased basal insulin delivery. By contrast, basal insulin decreased slightly in well-controlled users. CONCLUSIONS: Most MiniMed 670G system users in Europe achieved TIR more than 70% and GMI less than 7% while minimizing hypoglycaemia, in a real-world environment. These international consensus-met outcomes were enabled by automated insulin delivery meeting real-time insulin requirements adapted to each individual user.


Asunto(s)
Diabetes Mellitus Tipo 1 , Sistemas de Infusión de Insulina , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Diabetes Mellitus Tipo 1/epidemiología , Europa (Continente)/epidemiología , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...