Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
J Clin Med ; 13(17)2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39274553

RESUMEN

Background: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE neo2 (NEO2). Methods: Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. Results: Patients were retrospectively divided into high (<3 mm; n = 412), optimal (3-7 mm; n = 1236), and low (>7 mm; n = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, p = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, p = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, p = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm2/m2 vs. 0.95 cm2/m2 vs. 0.92 cm2/m2, p < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, p = 0.001). Conclusions: Implantation with the ACURATE neo2 showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.

2.
J Clin Med ; 13(14)2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39064227

RESUMEN

Background/Objectives: Previous trials reported comparable results with PASCAL and earlier MitraClip generations. Limited comparative data exist for more contemporary MitraClip generations, particularly the large MitraClip XT(R/W). We aimed to evaluate acute and 30-day outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) with one of the large devices, either PASCAL P10 or MitraClip XT(R/W) (3rd/4th generation). Methods: A total of 309 PASCAL-treated patients were matched by propensity score to 253 MitraClip-treated patients, resulting in 200 adequately balanced pairs. Procedural, clinical, and echocardiographic outcomes were collected for up to 30 days, including subgroup analysis for mitral regurgitation (MR) etiologies. Results: PASCAL and MitraClip patients were comparable regarding age (80 vs. 79 years), sex (female: 45.5% vs. 50.5%), and MR etiology (degenerative MR: n = 94, functional MR [FMR]: n = 96, mixed MR: n = 10 in each group). Technical success rates were comparable (96.5% vs. 96.0%; p > 0.999). At discharge, the mean gradient was higher (3.3 mmHg vs. 3.0 mmHg; p = 0.038), and the residual mitral valve orifice area was smaller in MitraClip patients (3.0 cm2 vs. 2.3 cm2; p < 0.001). At discharge, the reduction to MR ≤ 2+ was comparable (92.4% vs. 87.8%; p = 0.132). However, reduction to MR ≤ 1+ was more frequently observed in PASCAL patients (67.7% vs. 56.6%; p = 0.029), driven by the FMR subgroup (74.0% vs. 60.0%; p = 0.046). No difference was observed in 30-day mortality (p = 0.204) or reduction in NYHA-FC to ≤II (p > 0.999). Conclusions: Both M-TEER devices exhibited high and comparable rates of technical success and MR reduction to ≤2+. PASCAL may be advantageous in achieving MR reduction to ≤1+ in patients with FMR.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38860614

RESUMEN

BACKGROUND: Challenging anatomies and comorbidities have impact on success in transcatheter aortic valve replacement (TAVR). There is controversy whether the extent of the aortic angle (AA) has an impact on procedural outcomes. Matched comparative outcome data of new generation transcatheter heart valves (THVs) in horizontal aorta (HA) are scarce. METHODS: A total of 1582 patients with severe native aortic stenosis (AS) treated with the SAPIEN3 Ultra (Ultra; n = 526) or ACURATE Neo2 (Neo2; n = 1056) THVs from January 2017 to January 2023 were analyzed. Patients with non-horizontal aortas (AA < 51.7°, n = 841) were excluded. The population was matched by 1-to-1 nearest-neighbor matching (Ultra, n = 246; Neo2, n = 246). Clinical and procedural outcome were evaluated according to VARC-3 recommendations. RESULTS: Technical success (93.1% vs. 94.7%, p = 0.572) was high after Ultra and Neo2. Device success (80.5% vs. 89.8%, p = 0.05) was inferior with Ultra. Neo2 reveals superior hemodynamic properties with lower rate of severe prosthesis patient mismatch (12.0% vs. 3.7%, p = 0.001) and elevated gradients ( ≥ $\ge $ 20 mmHg: 11.9% vs. 1.7%, p < 0.001). Ultra showed a lower rate of relevant paravalvular regurgitation ( > $\gt $ mild paravalvular regurgitation or Valve-in-Valve due to paravalvular regurgitation: 0.0% vs. 3.7%, p = 0.004). The rate of procedural bailout maneuvers (0.8% vs. 0.4%, p = 1.000) and thirty-day all-cause mortality (1.3% vs. 2.2%, p = 0.496) was similar. CONCLUSION: Transfemoral TAVR in patients with severe aortic stenosis and HA, using the balloon expandable Sapien3 Ultra and self-expanding ACURATE Neo2 prosthesis, is feasible and safe. Therefore, valve selection between these platforms should be made irrespective of the aortic angle by a team experienced with both valves based on their specific advantages. Large, randomized trials in this sub-group of patients would be necessary to compare long term outcomes.

4.
Heart Lung Circ ; 33(9): 1272-1279, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38811293

RESUMEN

BACKGROUND: Diabetic patients with coronary artery disease may benefit from elective coronary artery bypass graft (CABG) surgery. It is unknown whether this merit is transferable to patients with acute myocardial infarction (AMI) undergoing surgery. METHOD: A total of 1,427 patients underwent CABG within 48 hours of being diagnosed with AMI at the current institution between 2001 and 2019. Of these patients, 206 (14.4%) had insulin-dependent diabetes mellitus (IDDM) and 148 (10.4%) had non-insulin dependent diabetes mellitus (NIDDM). Retrospective data analysis was performed. RESULTS: Patients with NIDDM showed the highest perioperative risk profile, with a EuroScore II of 11.6 (±10.3) compared with 7.8 (±8.0) in non-diabetic patients and 8.4 (±7.8) in patients with IDDM (p<0.001). Sub-analysis demonstrated a higher proportion of non-ST-elevation myocardial infarction patients in the NIDDM cohort compared with the IDDM cohort (70.9% vs 56.8%; p=0.005). Postoperatively, NIDDM patients had more sepsis (p<0.01) and longer ventilation times (p<0.001) compared with non-DM and IDDM patients (p<0.01). Wound healing complications were rare, but almost twice as high in NIDDM patients compared with non-DM and IDDM patients (4.7% vs 0.9% vs 2.4%, respectively). The 30-day mortality was highest in the NIDDM cohort (18.3% vs 11.3% vs 7.8%; p=0.012). Analysis of survival for up to 15 years revealed a significantly reduced survival of diabetic patients compared with non-diabetic patients, with lowest survival rates in NIDDM patients (p<0.001). CONCLUSIONS: Non-insulin dependent diabetes mellitus patients undergoing CABG within 48 hours of being diagnosed with AMI are at increased risk of short-term and long-term complications. Therefore, this particular group should undergo a careful evaluation concerning the expected risks and benefits of CABG in this setting.


Asunto(s)
Puente de Arteria Coronaria , Infarto del Miocardio , Humanos , Masculino , Puente de Arteria Coronaria/efectos adversos , Puente de Arteria Coronaria/métodos , Femenino , Estudios Retrospectivos , Infarto del Miocardio/cirugía , Infarto del Miocardio/epidemiología , Infarto del Miocardio/complicaciones , Anciano , Persona de Mediana Edad , Factores de Tiempo , Factores de Riesgo , Diabetes Mellitus Tipo 2/complicaciones , Tasa de Supervivencia/tendencias , Estudios de Seguimiento , Complicaciones Posoperatorias/epidemiología , Diabetes Mellitus Tipo 1/complicaciones , Medición de Riesgo/métodos
5.
Circ Cardiovasc Interv ; 17(5): e013608, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38529637

RESUMEN

BACKGROUND: Comparative data on transcatheter self-expanding ACURATE neo2 (NEO2) and balloon-expandable SAPIEN 3 Ultra prostheses in technically challenging anatomy of severe aortic valve calcified aortic annuli are scarce. METHODS: A total of 1987 patients with severe native aortic stenosis treated with the self-expanding NEO2 (n=1457) or balloon-expandable SAPIEN 3 Ultra (n=530) from January 2017 to April 2023 were evaluated. The primary end point was procedural outcome according to the Valve Academic Research Consortium 3 definitions. Propensity matching defined 219 pairs with severe calcification (calcium density cutoff, 758 AU/cm2) of the native aortic valve. RESULTS: Technical success (90.4% versus 91.8%; risk difference, 1.4% [95% CI, -4.4 to -7.2]; P=0.737) and device success at 30 days (80.8% versus 75.8%; risk difference, -5.0% [95% CI, -13.2 to 3.1]; P=0.246) were comparable between NEO2 and SAPIEN 3 Ultra. The rate of severe prosthesis-patient mismatch (1.1% versus 10.1%; risk difference, 10.0% [95% CI, 4.0-13.9]; P<0.001) and mean transvalvular gradient ≥20 mm Hg (2.8% versus 14.3%; risk difference, 11.5% [95% CI, 5.8-17.1]; P<0.001) was lower with NEO2. The rate of more-than-mild paravalvular leakage or valve-in-valve due to paravalvular leakage was significantly higher (6.2% versus 0.0%; risk difference, 6.2% [95% CI, -10.1 to -2.7]; P=0.002), and there was a tendency for a higher rate of device embolization or migration (1.8% versus 0.0%; risk difference, -1.8% [95% CI, -4.1 to 0.4]; P=0.123) with NEO2. Multivarate regression revealed no independent impact of transcatheter heart valve selection on device success (odds ratio, 0.93 [95% CI, 0.48-1.77]; P=0.817). CONCLUSIONS: In patients with severely calcified annuli, supraannular implantation of NEO2 showed hemodynamic advantages. Nevertheless, NEO2 was associated with a higher incidence of relevant paravalvular leakage and a numerically higher rate of device embolization than SAPIEN 3 Ultra in this particular patient group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Masculino , Femenino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Resultado del Tratamiento , Factores de Riesgo , Factores de Tiempo , Medición de Riesgo , Estudios Retrospectivos , Puntaje de Propensión , Recuperación de la Función , Valvuloplastia con Balón/efectos adversos , Hemodinámica
6.
Front Cardiovasc Med ; 11: 1263905, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343872

RESUMEN

In a female patient with acute cardiac decompensation, an auxiliary finding of a giant left atrium emerged. The surgical therapy of the atrial reduction, in addition to a mitral valve replacement and a coronary artery bypass grafting, is hereby presented.

8.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38084735

RESUMEN

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos
9.
Cardiol J ; 30(6): 1003-1009, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37964645

RESUMEN

BACKGROUND: Patients with complex coronary artery disease (CAD) may benefit from surgical myocardial revascularization but weighing the risk of peri-operative complications against the expected merit is difficult. Minimally invasive direct artery bypass (MIDCAB) procedures are less invasive, provide the prognostic advantage of operative revascularization of the left anterior descending artery and may be integrated in hybrid strategies. Herein, the outcomes between patients with coronary 1-vessel disease (1-VD) and patients with 2-VD and 3-VD after MIDCAB procedures were compared in this single-center study. METHODS: Between 1998 and 2018, 1363 patients underwent MIDCAB at the documented institution. 628 (46.1%) patients had 1-VD, 434 (31.9%) patients 2-VD and 300 (22.0%) patients suffered from 3-VD. Data of patients with 2-VD, and 3-VD were pooled as multi-VD (MVD). RESULTS: Patients with MVD were older (66.2 ± 10.9 vs. 62.9 ± 11.2 years; p < 0.001) and presented with a higher EuroScore II (2.10 [0.4; 34.2] vs. 1.2 [0.4; 12.1]; p < 0.001). Procedure time was longer in MVD patients (131.1 ± 50.3 min vs. 122.2 ± 34.5 min; p < 0.001). Post-operatively, MVD patients had a higher stroke rate (17 [2.3%] vs. 4 [0.6%]; p = 0.014). No difference in 30-day mortality was observed (12 [1.6%] vs. 4 [0.6%]; p = 0.128). Survival after 15 years was significantly lower in MVD patients (p < 0.01). Hybrid procedures were planned in 295 (40.2%) patients with MVD and realized in 183 (61.2%) cases. MVD patients with incomplete hybrid procedures had a significantly decreased long-term survival compared to cases with complete revascularization (p < 0.01). CONCLUSIONS: Minimally invasive direct coronary artery bypass procedures are low-risk surgical procedures. If hybrid procedures have been planned, completion of revascularization should be a major goal.


Asunto(s)
Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Puente de Arteria Coronaria/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Revascularización Miocárdica/métodos
10.
J Clin Med ; 12(12)2023 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-37373693

RESUMEN

BACKGROUND: Third-generation transcatheter heart valves (THVs) are designed to improve outcomes. Data on the new intra-annular self-expanding NAVITOR are scarce. AIMS: The aim of this analysis was to compare outcomes between the PORTICO and the NAVITOR systems. METHODS: Data from 782 patients with severe native aortic stenosis treated with PORTICO (n = 645) or NAVITOR (n = 137) from 05/2012 to 09/2022 were evaluated. The clinical and hemodynamic outcomes of 276 patients (PORTICO, n = 139; NAVITOR, n = 137) were evaluated according to VARC-3 recommendations. RESULTS: Rates of postprocedural more-than-mild paravalvular leakage (PVL) were significantly lower for NAVITOR than for PORTICO (7.2% vs. 1.5%, p = 0.041). In addition, severe bleeding rates (27.3% vs. 13.1%, p = 0.005) and major vascular complications (5.8% vs. 0.7%, p = 0.036) were lower in the NAVITOR group. The mean gradients (7 vs. 8 mmHg, p = 0.121) and calculated aortic valve areas (1.90 cm2 vs. 1.99 cm2, p = 0.235) were comparable. Rates of PPI were similarly high in both groups (15.3 vs. 21.6, p = 0.299). CONCLUSIONS: The NAVITOR demonstrated favorable in-hospital procedural outcome data, with lower rates of relevant PVL, major vascular complications, and severe bleeding than its predecessor the PORTICO and preserved favorable hemodynamic outcomes.

11.
Diagnostics (Basel) ; 13(7)2023 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-37046575

RESUMEN

OBJECTIVES: This study examined the prognostic value of the get-with-the-guidelines heart-failure risk score (GWTG-HF) on mortality in patients with low-flow-low-gradient aortic valve stenosis (LFLG-AS) after transcatheter aortic valve implantation (TAVI). BACKGROUND: Data on feasibility of TAVI and mortality prediction in the LFLG-AS population are scarce. Clinical risk assessment in this particular population is difficult, and a score has not yet been established for this purpose. METHODS: A total of 212 heart failure (HF) patients with real LFLG-AS were enrolled. Patients were classified into low-risk (n = 108), intermediate-risk (n = 90) and high-risk (n = 14) groups calculated by the GWTG-HF score. Clinical outcomes of cardiovascular events according to Valve Academic Research Consortium (VARC-2) recommendations and composite endpoint of death and hospitalization for heart failure (HHF) were assessed at discharge and 1 year of follow-up. RESULTS: Baseline parameters of the groups showed a median age of 81.0 years [77.0; 84.0] (79.0 vs. 82.0 vs. 86.0, respectively p < 0.001), median EuroSCORE II of 6.6 [4.3; 10.7] (5.5 vs. 7.2 vs. 9.1, p = 0.004) and median indexed stroke volume of 26.7 mL/m2 [22.0; 31.0] (28.2 vs. 25.8 vs. 25.0, p = 0.004). The groups significantly differed at follow-up in terms of all-cause mortality (10.2 vs. 21.1 vs. 28.6%; p < 0.035). There was no difference in intrahospital event rate (VARC). Postprocedural mean gradients were lower in high-risk group (7.0 vs. 7.0 vs. 5.0 mmHg, p = 0.011). No differences in postprocedural aortic valve area (1.9 vs. 1.7 vs. 1.9 cm2, p = 0.518) or rate of device failure (5.6 vs. 6.8 vs. 7.7%, p = 0.731) could be observed. After adjustment for known predictors, the GWTG score (HR 1.07 [1.01-1.14], p = 0.030) as well as pacemaker implantation (HR 3.97 [1.34-11.75], p = 0.013) turned out to be possible predictors for mortality. An increase in stroke volume index (SVI) was, in contrast, protective (HR 0.90 [0.83-0.97]; p = 0.006). CONCLUSIONS: The GWTG score may predict mortality after TAVI in LFLG-AS HF patients. Interestingly, all groups showed similar intrahospital event and mortality rates, independent of calculated mortality risk. Low SVI and new conduction disturbances associated with PPI after THV implantation had negative impact on mid-term outcome in post-TAVI HF-patients.

12.
J Clin Med ; 12(3)2023 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-36769593

RESUMEN

BACKGROUND: Severe calcification of the ascending aorta increases the peri-operative risk for neurological complications in patients with severe aortic stenosis. Transcatheter aortic valve implantation (TAVI) seems to be an optimal treatment option in these patients. However, the impact of the extent of aortic calcification on procedural and neurological outcomes during TAVI is unclear. METHODS: Data from 3010 patients with severe native aortic valve stenosis treated with ACURATE neo/neo2 from May 2012 to July 2022 were evaluated and matched by 2-to-1 nearest-neighbor matching to identify one patient with porcelain aorta (PA) (n = 492) compared with two patients without PA (n = 984). PA was additionally subdivided into circumferential (classic PA) (n = 89; 3.0%) and non-circumferential (partial PA) (n = 403; 13.4%) calcification. We compared outcomes according to VARC-3 criteria among patients with and without PA and identified predictors for occurrence of stroke in the overall population. RESULTS: Technical success (88.5% vs. 87.4%, p = 0.589) and device success at 30 days (82.3% vs. 81.5%, p = 0.755) after transcatheter ACURATE neo/neo2 implantation according to VARC-3 definition was high and did not differ between non-calcified aortas or PA. The rate of in-hospital complications according to VARC-3-definitions was low in both groups. Rates of all stroke (3.2% (n = 31) vs. 2.6% (n = 13), p = 0.705) or transitory ischemic attacks (1.1% vs. 1.2%, p = 1.000) did not differ significantly. Thirty-day all-cause mortality did not differ (3.0% vs. 3.2%, RR 1.1; p = 0.775). Overall device migration/embolization (OR 5.0 [2.10;11.87]), severe bleeding (OR 1.79 [1.11;2.89]), and major structural cardiac complications (OR 3.37 [1.32;8.57]) were identified as independent predictors for in-hospital stroke in a multivariate analysis after implantation of ACURATE neo/neo2. CONCLUSION: A porcelain aorta does not increase the risk of neurological complications after transfemoral ACURATE neo/neo2 implantation. Based on these findings, transfemoral ACURATE neo/neo2 implantation is safe in these particularly vulnerable patients.

14.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36543448

RESUMEN

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Puntaje de Propensión , Función Ventricular Izquierda , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos
15.
J Invasive Cardiol ; 34(11): E804-E810, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36269158

RESUMEN

BACKGROUND: Few data exist on immediate outcomes of the next-generation Acurate neo2 prosthesis (Boston Scientific), which is distinguished by an active sealing mechanism. We sought to determine procedural outcomes of transfemoral transcatheter aortic valve replacement using the neo2 in comparison with its predecessor, the Acurate neo. METHODS: In this retrospective analysis, consecutive neo2 and neo cases were compared from 2 high-volume centers. The primary outcome of interest was the rate of relevant paravalvular regurgitation (PVR), defined as PVR ≥ moderate, or valve-in-valve and/or surgical aortic valve replacement for PVR ≥ moderate. Secondary outcomes of interest were assessed according to Valve Academic Research Consortium (VARC)-3 criteria. Logistic regression analysis was used to identify predictors of relevant PVR. RESULTS: A total of 810 neo2 and 2055 neo cases comprised the study cohort. The rate of relevant PVR was significantly lower in the neo2 group (2.7% vs 4.5%; P=.04). The technical success rate was numerically higher in the neo2 group (91.5% vs 89.3%; P=.10) and the rate of device success at 30 days was significantly higher (86.5% vs 82.9%; P=.02). In the neo group, a greater amount of aortic valve calcification (AVC), the presence of eccentric AVC, less oversizing, and a higher sinotubular junction annulus index were predictors of relevant PVR, whereas in the neo2 population only the presence of eccentric AVC, less oversizing, and a higher sinotubular junction annulus index was predictive. CONCLUSION: The neo2 valve shows superior outcomes over the neo valve, with a lower burden of PVR and a higher device success rate at 30 days.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Clin Med ; 11(18)2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36142960

RESUMEN

BACKGROUND: Self-expanding transcatheter valves (THV) seem superior to balloon-expanding valves in regard to the incidence of prosthesis-patient mismatch (PPM). Data on the occurrence of PPM with the ACURATE neo/neo2 system as a representative of self-expanding prostheses in very small annuli, even below the applicable instructions for use (IFU), are scarce. METHODS: Data from 654 patients with severe native aortic stenosis treated with the smallest size ACURATE neo/neo2 valve (size S, 23 mm) at two German high-volume centers from 06/2012 to 12/2021 were evaluated. We compared clinical and hemodynamic outcomes among patients with implantation in adherence to the recommended sizing (on-label n = 529) and below the recommended sizing range (off-label n = 125) and identified predictors for PPM in the overall population. BMI-adjusted PPM was defined according to VARC-3 recommendations. RESULTS: Post-procedure, the mean gradient (10.0 mmHg vs. 9.0 mmHg, p = 0.834) and the rate of paravalvular leakage (PVL) ≥ moderate (3.2% vs. 2.8%, p = 0.770) were similar between on-label and off-label implantations. The rate of moderate to severe PPM (24%) was comparably low in ACURATE neo/neo2 S, with a very low proportion of severe PPM whether implanted off- or on-label (4.9% vs. 3.8%, p = 0.552). Thirty-day all-cause mortality was higher among patients with off-label implantations (6.5% vs. 2.3%, p = 0.036). In the subgroup of these patients, no device-related deaths occurred, and cardiac causes did not differ (each 5). Besides small annulus area and high BMI, a multivariate analysis identified a greater cover index (OR 3.26), deep implantation (OR 2.25) and severe calcification (OR 2.07) as independent predictors of PPM. CONCLUSIONS: The ACURATE neo/neo2 S subgroup shows a convincing hemodynamic outcome according to low mean gradient even outside the previous IFUs without a relevant increase in the rate of PVL or PPM. In addition to known factors such as annulus area and BMI, potential predictors for PPM are severe annulus calcification and implantation depth. Nevertheless, the ACURATE neo/neo2 system seems to be a reliable option in patients with very small annuli.

17.
J Clin Med ; 11(14)2022 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-35887990

RESUMEN

BACKGROUND: During the last years, several transcatheter aortic heart valves entered the clinical market and are commercially available. The prostheses differ regarding several technical and functional aspects. However, little is known regarding head-to-head comparative data of the ACURATE neo and the PORTICO valve prostheses. OBJECTIVES: The aim of this study was to compare two self-expanding transcatheter aortic heart valves (THV), the ACURATE neo and the PORTICO, with regard to in-hospital and 30-day outcomes, as well as early device failures. METHODS: A total of 1591 consecutive patients with severe native aortic valve stenosis from two centers were included in the analyses and matched by 1:1 nearest neighbor matching to identify one patient treated with PORTICO (n = 344) for each patient treated with ACURATE neo (n = 344). RESULTS: In-hospital complications were comparable between both valves, including any kind of stroke (ACURATE neo = 3.5% vs. PORTICO = 3.8%; p = 1.0), major vascular complications (ACURATE neo = 4.5% vs. PORTICO = 5.4%; p = 0.99) or life-threatening bleeding (ACURATE neo = 1% vs. PORTICO = 2%; p = 0.68). The rate of device failure defined by the VARC-2 criteria were comparable, including elevated gradients and moderate-to-severe paravalvular leakage (ACURATE neo = 7.3% vs. PORTICO = 7.6%; p = 1.0). However, the need for permanent pacemaker implantation (PPI) was significantly more frequent after the use of PORTICO THV (9.5% vs. 18.7%; p = 0.002). CONCLUSIONS: In this two-center case-matched comparison, short-term clinical and hemodynamic outcomes showed comparable results between PORTICO and ACURATE neo prostheses. However, PORTICO was associated with a significant higher incidence of PPI.

18.
J Cardiovasc Med (Hagerstown) ; 23(8): 519-523, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35905002

RESUMEN

AIMS: Patients with pulmonary embolism (PE) and contraindications for or failed thrombolysis are at the highest risk for PE-related fatal events. These patients may benefit from surgical embolectomy, but data concerning this approach are still limited. METHODS: The method used here was retrospective data analysis of 103 patients who underwent surgical embolectomy from 2002 to 2020 at our department. RESULTS: Mean age was 58.4 (±15.1) years. Fifty-eight (56.3%) patients had undergone recent surgery; the surgery was tumor associated in 32 (31.1%) cases. Thirty (29.1%) patients had to be resuscitated due to PE, and 13 (12.6%) patients underwent thrombolysis prior to pulmonary embolectomy. Fifteen (14.5%) patients were placed on extra corporeal membrane oxygenation (ECMO) peri-operatively. Five patients (4.9%) died intra-operatively. Neurological symptoms occurred in four patients (3.9%). Thirty-day mortality was 23.3% ( n  = 24). Re-thoracotomy due to bleeding was necessary in 12 (11.6%) patients. This parameter was also identified as an independent risk factor for mortality. CONCLUSION: Surgical pulmonary embolectomy resulted in survival of the majority of patients with PE and contraindications for or failed thrombolysis. Given the excessive mortality when left untreated, an operative approach should become a routine part of discussions concerning alternative treatment options for these patients.


Asunto(s)
Embolia Pulmonar , Terapia Trombolítica , Enfermedad Aguda , Embolectomía/efectos adversos , Embolectomía/métodos , Humanos , Persona de Mediana Edad , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/cirugía , Estudios Retrospectivos , Terapia Trombolítica/efectos adversos , Resultado del Tratamiento
19.
Clin Res Cardiol ; 111(8): 924-933, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35362737

RESUMEN

BACKGROUND: Based on the results of several recent randomized trials, European and American guidelines on valvular heart disease management have substantially expanded the indications for transcatheter aortic valve implantation (TAVI). We present an all-comer data on peri-operative risk profile and in-hospital outcomes from Germany for patients treated by TAVI or isolated surgical aortic valve replacement (iSAVR) in 2020, providing an opportunity to compare study data with data from daily clinical practice. METHODS: Data concerning all isolated aortic valve procedures performed in Germany in 2020 were retrieved from the mandatory nationwide quality control program. Expected mortality was calculated with the annually revised German Aortic valve score (AKL-score) based on the data of either catheter-based (AKL-CATH) or isolated surgical (AKL-CHIR) aortic valve replacement in Germany from the previous year (2019). RESULTS: In 2020 21,903 TAVI procedures (20,810 transvascular (TV; vs. 2019: 22.973; - 9.4%), 1093 transapical (TA; vs. 2019: 1413; - 22.6%)) and 6144 (vs. 2019 7905; - 22.5%) iSAVR were performed in Germany. Patients who received TAVI showed a significantly higher perioperative risk profile than patients undergoing iSAVR based on older age and more severe co-morbidities. While in-hospital mortality after TAVI (2.3%) was numerically lower than in 2019 (2.5%), this difference was not significant (p = 0.11). In-hospital mortality after iSAVR was identical in 2020 and 2019 (2.8%) and thus higher than after TAVI (p = 0.003), resulting in an observed expected mortality ratio of 1.02 after TAVI and 1.05 after iSAVR. After exclusion of the emergency procedures, in-hospital mortality did not differ significantly between the groups (TAVI 2.2% vs. iSAVR 1.9%, p = 0.26). CONCLUSION: Total numbers of both iSAVR and TAVI in Germany were lower in 2020 than in 2019, most likely due to the COVID-19 pandemic. However, the relative number of patients treated by TAVI as compared to iSAVR continues to increase. Despite older age and more severe comorbidities compared to patients undergoing iSAVR the in-hospital mortality after TAVI continued to decrease in 2020 and remains significantly lower than after iSAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , COVID-19 , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Alemania/epidemiología , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Pandemias , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
20.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-35138350

RESUMEN

OBJECTIVES: There are disparities in the adherence to guideline-recommended therapies after coronary artery bypass graft (CABG). We therefore sought to evaluate the effect of guideline-adherent medical secondary prevention on 1-year outcome after CABG. METHODS: Data were taken from the randomized 'Ticagrelor in CABG' trial. From April 2013 until April 2017, patients who underwent CABG were included. For the present analysis, we compared patients who were treated with optimal medical secondary prevention with those where 1 or more of the recommended medications were missing. RESULTS: Follow-up data at 12 months were available in 1807 patients. About half (54%) of them were treated with optimal secondary prevention. All-cause mortality [0.5% vs 3.5%, hazard ratio (HR) 0.14 (0.05-0.37), P < 0.01], cardiovascular mortality [0.1% vs 1.7%, HR 0.06 (0.01-0.46), P = 0.007] and major adverse events [6.5% vs 11.5%, HR 0.54 (0.39-0.74), P < 0.01] were significantly lower in the group with optimal secondary prevention. The multivariable model for the primary end point based on binary concordance to guideline recommended therapy identified 3 independent factors: adherence to guideline recommended therapy [HR 0.55 (0.39-0.78), P < 0.001]; normal renal function [HR 0.99 (0.98-0.99), P = 0.040]; and off-pump surgery [HR 2.06 (1.02-4.18), P = 0.045]. CONCLUSIONS: Only every second patient receives optimal secondary prevention after CABG. Guideline adherent secondary prevention therapy is associated with lower mid-term mortality and less adverse cardiovascular events after 12 months.


Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria , Puente de Arteria Coronaria/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Pronóstico , Prevención Secundaria , Ticagrelor , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA