Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
2.
Brain Commun ; 3(3): fcab165, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34396114

RESUMEN

Patients with Parkinson's disease can develop axial symptoms, including speech, gait and balance difficulties. Chronic high-frequency (>100 Hz) deep brain stimulation can contribute to these impairments while low-frequency stimulation (<100 Hz) may improve symptoms but only in some individuals. Factors predicting which patients benefit from low-frequency stimulation in the long term remain unclear. This study aims to confirm that low-frequency stimulation improves axial symptoms, and to go further to also explore which factors predict the durability of its effects. We recruited patients who developed axial motor symptoms while using high-frequency stimulation and objectively assessed the short-term impact of low-frequency stimulation on axial symptoms, other aspects of motor function and quality of life. A retrospective chart review was then conducted on a larger cohort to identify which patient characteristics were associated with not only the need to trial low-frequency stimulation, but also those which predicted its sustained use. Among 20 prospective patients, low-frequency stimulation objectively improved mean motor and axial symptom severity and quality of life in the short term. Among a retrospective cohort of 168 patients, those with less severe tremor and those in whom axial symptoms had emerged sooner after subthalamic nucleus deep brain stimulation were more likely to be switched to and remain on long-term low-frequency stimulation. These data suggest that low-frequency stimulation results in objective mean improvements in overall motor function and axial symptoms among a group of patients, while individual patient characteristics can predict sustained long-term benefits. Longer follow-up in the context of a larger, controlled, double-blinded study would be required to provide definitive evidence of the role of low-frequency deep brain stimulation.

3.
Mov Disord ; 35(12): 2261-2269, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32979290

RESUMEN

BACKGROUND: Subthalamic nucleus deep brain stimulation (STN-DBS) is a widely used treatment for Parkinson's disease (PD) patients with motor complications, but can result in adverse effects (AEs) in a significant proportion of treated patients. The use of novel programming features including short pulse width (PW) and directional steering in alleviating stimulation-induced AEs has not been explored. OBJECTIVE: To determine if programming with short PW, directional steering, or the combination of these novel techniques can improve stimulation-induced dysarthria, dyskinesia, and pyramidal AEs. METHODS: Thirty-two consecutive PD patients who experienced reversible AEs of STN-DBS had optimization of their settings using either short PW, directional steering, or the combination, while ensuring equivalent control of motor symptoms. Pairwise comparisons of pre- and post-optimization adverse effect ratings were made. Patients were left on the alternative setting with the greatest benefit and followed up at 6 months. Modeling of volume of tissue activated (VTA) and charge per pulse (Qp) calculations were used to explore potential underlying mechanisms of any differences found. RESULTS: There were significant improvements in stimulation-induced dysarthria, dyskinesia, and pyramidal side effects after optimization. At 6 months, mean AE ratings remained significantly improved compared to pre-optimization ratings. Different patterns of shift in VTA for each AE, and Qp could be used to explain improvements using novel techniques. CONCLUSIONS: Stimulation-induced dysarthria, dyskinesia, and pyramidal AEs induced by STN-DBS can be improved by using novel programming techniques. These represent additional tools to conventional methods that can be used to address these AEs. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Asunto(s)
Estimulación Encefálica Profunda , Discinesias , Enfermedad de Parkinson , Núcleo Subtalámico , Humanos , Enfermedad de Parkinson/terapia , Resultado del Tratamiento
4.
Mov Disord ; 35(1): 101-108, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31571270

RESUMEN

BACKGROUND: Subthalamic nucleus deep brain stimulation (STN-DBS) is an effective therapy for selected Parkinson's disease patients with motor fluctuations, but can adversely affect speech and axial symptoms. The use of short pulse width (PW) has been shown to expand the therapeutic window acutely, but its utility in reducing side effects in chronic STN-DBS patients has not been evaluated. OBJECTIVE: To compare the effect of short PW settings using 30-µs with conventional 60-µs settings on stimulation-induced dysarthria in Parkinson's disease patients with previously implanted STN-DBS systems. METHODS: In this single-center, double-blind, randomized crossover trial, we assigned 16 Parkinson's disease patients who had been on STN-DBS for a mean of 6.5 years and exhibited moderate dysarthria to 30-µs or 60-µs settings for 4 weeks followed by the alternative PW setting for a further 4 weeks. The primary outcome was difference in dysarthric speech measured by the Sentence Intelligibility Test between study baseline and the 2 PW conditions. Secondary outcomes included motor, nonmotor, and quality of life measures. RESULTS: There was no difference in the Sentence Intelligibility Test scores between baseline and the 2 treatment conditions (P = 0.25). There were also no differences noted in motor, nonmotor, or quality of life scores. The 30-µs settings were well tolerated, and adverse event rates were similar to those at conventional PW settings. Post hoc analysis indicated that patients with dysarthria and a shorter duration of DBS may be improved by short PW stimulation. CONCLUSIONS: Short PW settings using 30 µs did not alter dysarthric speech in chronic STN-DBS patients. A future study should evaluate whether patients with shorter duration of DBS may be helped by short PW settings. © 2019 International Parkinson and Movement Disorder Society.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson/terapia , Núcleo Subtalámico/fisiopatología , Resultado del Tratamiento , Anciano , Estudios Cruzados , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Calidad de Vida
5.
J Parkinsons Dis ; 9(1): 141-151, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30594934

RESUMEN

BACKGROUND: Subthalamic deep brain stimulation (STN-DBS) is an established treatment for late stage Parkinson's disease (PD). Speech intelligibility (SI) and verbal fluency (VF) have been shown to deteriorate following chronic STN-DBS. It has been suggested that speech might respond favourably to low frequency stimulation (LFS). OBJECTIVE: We examined how SI, perceptual speech characteristics, phonemic and semantic VF and processes underlying it (clustering and switching) respond to LFS of 60 and 80 Hz in comparison to high frequency stimulation (HFS) (110, 130 and 200 Hz). METHODS: In this double-blind study, 15 STN-DBS PD patients (mean age 65, SD = 5.8, 14 right handed, three females), were assessed at five stimulation frequencies: 60 Hz, 80 Hz, 110 Hz, 130 Hz and 200 Hz. In addition to the clinical neurological assessment of speech, VF and SI were assessed. RESULTS: SI and in particular articulation, respiration, phonation and prosody improved with LFS (all p < 0.05). Phonemic VF switching improved with LFS (p = 0.005) but this did not translate to an improved phonemic VF score. A trend for improved semantic VF was found. A negative correlation was found between perceptual characteristics of speech and duration of chronic stimulation (all p < 0.05). CONCLUSIONS: These findings highlight the need for meticulous programming of frequency to maximise SI in chronic STN-DBS. The findings further implicate stimulation frequency in changes to specific processes underlying VF, namely phonemic switching and demonstrate the potential to address such deficits through advanced adjustment of stimulation parameters.


Asunto(s)
Estimulación Encefálica Profunda , Enfermedad de Parkinson/terapia , Trastornos del Habla/fisiopatología , Trastornos del Habla/terapia , Inteligibilidad del Habla/fisiología , Núcleo Subtalámico , Anciano , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/complicaciones , Trastornos del Habla/etiología , Resultado del Tratamiento
6.
J Parkinsons Dis ; 8(2): 273-279, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29843252

RESUMEN

BACKGROUND: Subthalamic nucleus deep brain stimulation (STN-DBS) is an established treatment for selected Parkinson's disease (PD) patients, but therapy is often limited by side effects. Previous studies indicate an inverse relationship of the therapeutic window (TW) to pulse width (PW) settings down to 60µs, but there is limited data available on the effect of shorter PWs. OBJECTIVE: To define the TW of STN-DBS in PD at PW of 30µs (PW30) relative to standard PW settings at 60µs (PW60), and to compare speed of gait and speech intelligibility on the two PW conditions. METHODS: Monopolar review data of 15 consecutive PD patients who had screening of contacts performed at PW60 and PW30 was used to calculate the TW at each contact. We compared the TWs of the most efficacious contact per STN, and a secondary analysis was performed comparing all contacts. Speed of gait with a timed 10 metre walk test, speech intelligibility, and perceptual characteristics of speech were also compared at the efficacy thresholds for PW60 and PW30. RESULTS: The TW was significantly greater at PW30 [3.8±1.6mA] than at PW60 [1.7±1.1mA]. In the secondary analysis, 110 TWs could be calculated and these remained significantly higher at PW30. The timed 10 metre walk at PW30 was faster than at PW60, and perceptual rating scores of speech were significantly improved at PW30. CONCLUSIONS: STN-DBS in PD patients using a PW of 30µs significantly increases the TW compared to standard PW settings, and this effect is consistent across all contacts of an electrode. Speed of gait and perceptual speech scores are also improved at 30µs settings.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Marcha/fisiología , Enfermedad de Parkinson/terapia , Inteligibilidad del Habla/fisiología , Núcleo Subtalámico/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...