Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-38860493

RESUMEN

AIMS: Transthoracic echocardiography is recommended in all patients with acute coronary syndrome but is time-consuming and lacks an evidence base. We aimed to assess the feasibility, diagnostic accuracy and time-efficiency of hand-held echocardiography in patients with acute coronary syndrome and describe the impact of echocardiography on clinical management in this setting. METHODS AND RESULTS: Patients with acute coronary syndrome underwent both hand-held and transthoracic echocardiography with agreement between key imaging parameters assessed using kappa statistics. The immediate clinical impact of hand-held echocardiography in this population was systematically evaluated.Overall, 262 patients (65±12 years, 71% male) participated. Agreement between hand-held and transthoracic echocardiography was good-to-excellent (kappa 0.60-1.00) with hand-held echocardiography having an overall negative predictive value of 95%. Hand-held echocardiography was performed rapidly (7.7±1.6 min) and completed a median of 5 [interquartile range 3-20] hours earlier than transthoracic echocardiography. Systematic hand-held echocardiography in all patients with acute coronary syndrome identified an important cardiac abnormality in 50% and the clinical management plan was changed by echocardiography in 42%. In 85% of cases, hand-held echocardiography was sufficient for patient decision-making and transthoracic echocardiography was no longer deemed necessary. CONCLUSIONS: In patients with acute coronary syndrome, hand-held echocardiography provides comparable results to transthoracic echocardiography, can be more rapidly applied and gives sufficient imaging information for decision-making in the vast majority of patients. Systematic echocardiography has clinical impact in half of patients, supporting the clinical utility of echocardiography in this population, and providing an evidence-base for current guidelines.

2.
EClinicalMedicine ; 8: 37-46, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31193636

RESUMEN

BACKGROUND: Patients with palpitations and pre-syncope commonly present to Emergency Departments (EDs) but underlying rhythm diagnosis is often not possible during the initial presentation. This trial compares the symptomatic rhythm detection rate of a smartphone-based event recorder (AliveCor) alongside standard care versus standard care alone, for participants presenting to the ED with palpitations and pre-syncope with no obvious cause evident at initial consultation. METHODS: Multi-centre open label, randomised controlled trial. Participants ≥ 16 years old presenting to 10 UK hospital EDs were included. Participants were randomised to either (a) intervention group; standard care plus the use of a smartphone-based event recorder or (b) control group; standard care alone. Primary endpoint was symptomatic rhythm detection rate at 90 days. Trial registration number NCT02783898 (ClinicalTrials.gov). FINDINGS: Two hundred forty-three participants were recruited over an 18-month period. A symptomatic rhythm was detected at 90 days in 69 (n = 124; 55.6%; 95% CI 46.9-64.4%) participants in the intervention group versus 11 (n = 116; 9.5%; 95% CI 4.2-14.8) in the control group (RR 5.9, 95% CI 3.3-10.5; p < 0.0001). Mean time to symptomatic rhythm detection in the intervention group was 9.5 days (SD 16.1, range 0-83) versus 42.9 days (SD 16.0, range 12-66; p < 0.0001) in the control group. The commonest symptomatic rhythms detected were sinus rhythm, sinus tachycardia and ectopic beats. A symptomatic cardiac arrhythmia was detected at 90 days in 11 (n = 124; 8.9%; 95% CI 3.9-13.9%) participants in the intervention group versus 1 (n = 116; 0.9%; 95% CI 0.0-2.5%) in the control group (RR 10.3, 95% CI 1.3-78.5; p = 0.006). INTERPRETATION: Use of a smartphone-based event recorder increased the number of patients in whom an ECG was captured during symptoms over five-fold to more than 55% at 90 days. This safe, non-invasive and easy to use device should be considered part of on-going care to all patients presenting acutely with unexplained palpitations or pre-syncope. FUNDING: This study was funded by research awards from Chest, Heart and Stroke Scotland (CHSS) and British Heart Foundation (BHF) which included funding for purchasing the devices. MR was supported by an NHS Research Scotland Career Researcher Clinician award.

3.
Int J Cardiol ; 288: 94-99, 2019 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-31047704

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a major preventable risk factor for stroke and may be silent in elderly individuals who are at especially high risk. This paper describes the first phase of implementation of a clinical AF detection programme in a community setting. Objectives were (i) to determine the feasibility of using a handheld ECG recording system for AF detection among individuals aged 65 years or more, who have cardiovascular risk factors. (ii) to estimate the yield of previously undiagnosed atrial fibrillation cases, and the proportion of these who would be suitable for oral anticoagulation. METHODS: a handheld ECG monitor was placed in each of 23 primary care practices across Scotland. Eligible patients attending for annual health checks had ECGs recorded, and the ECGs were transmitted and interpreted by two senior cardiologists. ECG quality was rated, and an adjudication made on the rhythm. For patients confirmed with AF, stroke and bleeding risk were estimated using CHA2DS2-VASc and HAS-BLED scoring tools. RESULTS: single lead ECGs were recorded in 1805 patients (703 female and 1102 male), mean (SD) age 74.9 (7.1) years. Rhythm regularity could be assessed in 98.7% of ECGs recorded. 92 patients (5.1%) were found to have AF. Median [range]CHA2DS2-VASc score was 4 ([2-7) and median [range] HAS-BLED score was 2 (1-5). CONCLUSION: handheld ECG recording can be used to identify AF in the primary care setting, with minimal training. The yield was relatively high.


Asunto(s)
Fibrilación Atrial/diagnóstico , Electrocardiografía/métodos , Frecuencia Cardíaca/fisiología , Salud Pública , Medición de Riesgo/métodos , Accidente Cerebrovascular/prevención & control , Telemedicina/métodos , Factores de Edad , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Escocia/epidemiología , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología
4.
Open Heart ; 6(1): e000962, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30997133

RESUMEN

Objectives: Optimal right ventricular lead placement remains controversial. Large studies investigating the safety and long-term prognosis of apical and septal right ventricular lead placement have been lacking. Methods: Consecutive patients undergoing pacemaker insertion for high-degree atrioventricular block at Edinburgh Heart Centre were investigated. Periprocedural 30-day complications were defined (infection/bleeding/pneumothorax/tamponade/lead displacement). Long-term clinical outcomes were obtained from the General Register of Scotland and electronic medical records. The primary endpoint was a composite of all-cause mortality, new heart failure, hospitalisation for a major cardiovascular event, as per the CArdiac REsynchronization in Heart Failure trial. Secondary endpoints were all-cause mortality, new heart failure and their composite. Results: 820 patients were included, 204 (25%) paced from the septum and 616 (75%) from the apex. All baseline variables were similar with the exception of age (septal: 73.2±1.1 vs apical: 76.9±0.5 years, p<0.001). Procedure duration (58±23 vs 55±25 min, p=0.3), complication rates (18 (8.8) vs 46 (7.5)%, p=0.5) and postimplant QRS duration (152 (23) vs 154 (27) ms, p=0.4) were similar. After 1041 days (IQR 564), 278 patients met the primary endpoint, with no difference between the septal and apical groups in unadjusted (HR 0.86 (95% CIs 0.64 to 1.15)) or multivariable analysis correcting for age, gender and comorbidity (HR 0.97 (95% CI 0.72 to 1.30)). Similarly, no differences were observed in the secondary endpoints. Conclusions: This large real-world cohort of patients undergoing right ventricular lead placement in the septum or apex demonstrated no difference in procedural complications nor long-term clinical outcomes. Both pacing strategies appear reasonable in routine practice.

5.
Trials ; 19(1): 711, 2018 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-30594256

RESUMEN

BACKGROUND: Palpitations and pre-syncope are together responsible for 300,000 annual Emergency Department (ED) attendances in the United Kingdom (UK). Diagnosis of the underlying rhythm is difficult as many patients are fully recovered on ED arrival; and examination and presenting electrocardiogram (ECG) are commonly normal. The only way to establish the underlying heart rhythm is to capture an ECG during symptoms. Recent technology advances have led to several novel ECG monitoring devices appearing on the market. This trial aims to compare the symptomatic rhythm detection rate at 90 days of one such smart phone-based event recorder (AliveCor Heart Monitor and AliveECG) with standard care for participants presenting to the ED with palpitations and pre-syncope and no obvious cause in the ED. METHODS/DESIGN: This is a multi-centre hospital ED / Acute Medical Unit (AMU) open label, randomised controlled trial. Participants will be recruited in 10 tertiary and district general hospitals in the UK. Participants aged ≥ 16 years presenting with an episode of palpitations or pre-syncope with no obvious cause and whose underlying ECG rhythm during these episodes remains undiagnosed after clinical assessment will be included. Participants will be randomised to either: (1) the intervention arm, standard care plus the use of a smart phone-based event recorder; or (2) the control arm, standard care. Primary endpoint will be symptomatic rhythm detection rate at 90 days. A number of secondary clinical, process and cost-effectiveness endpoints will be collected and analysed. Analysis will be on an intention-to-treat basis. DISCUSSION: The Investigation of Palpitations in the ED (IPED) study aims to recruit 242 participants across 10 hospital sites. It will be the first study to investigate the ability of a smart phone-based event recorder to detect symptomatic cardiac rhythms compared to standard care for ED patients with palpitations and pre-syncope with no obvious cause in the ED. This smart phone event recorder will allow ED patients who have presented with palpitations or pre-syncope to record their ECG tracing if they have a further episode and may increase the rate of underlying rhythm diagnosis. TRIAL REGISTRATION: ClinicalTrials.gov, NCT02783898 . Registered on 26 May 2016.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía Ambulatoria/instrumentación , Servicio de Urgencia en Hospital , Frecuencia Cardíaca , Aplicaciones Móviles , Teléfono Inteligente , Síncope/diagnóstico , Telemetría/instrumentación , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Humanos , Estudios Multicéntricos como Asunto , Valor Predictivo de las Pruebas , Pronóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Síncope/fisiopatología , Síncope/terapia , Factores de Tiempo , Reino Unido
6.
Emerg Med J ; 35(8): 477-485, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29921622

RESUMEN

OBJECTIVES: Diagnosing underlying arrhythmia in ED syncope patients remains problematic. This study investigates diagnostic yield, event prevalence, patient satisfaction and compliance, and influence on resource utilisation of an ambulatory patch monitor in unexplained ED syncope patients. METHODS: Prospective pilot study conducted in a single tertiary ED in Scotland between 17 November 2015 and 16 June 2017 with a historical unmatched comparator group. Patients 16 years or over presenting within 6 hours of unexplained syncope were fitted in the ED with an ambulatory patch ECG recorder (Zio XT monitor), which continuously records a single-lead ECG for up to 14 days. Patients with an obvious underlying cause were excluded. An unmatched historical group of 603 syncope patients with no obvious diagnosis in ED, recruited to a prior cohort study (2007-2008), were used as a comparator. Primary endpoint was symptomatic significant arrhythmia at 90-day follow-up. RESULTS: During the prospective study period, 86 patients were recruited. 90-day diagnostic yield for symptomatic significant arrhythmia was 10.5% (95% CI 4.0 to 16.9; 9 of 86) versus 2.0% (95% CI 0.9 to 3.1; 12 of 603) in the comparator group. 24 patients (27.9%) had a significant arrhythmia (five serious); 26 patients (30.2%) had serious outcomes (major adverse cardiac event and/or death). Blinded patch report review suggested the patch would significantly reduce requirement for standard outpatient ambulatory ECG monitoring. 56 of 76 returned patches had a diagnostic finding within±45 s of a triggered/diary event (73.7% diagnostic utility; 95% CI 63.7 to 83.6); 34 of 56 (61%) for sinus rhythm or ectopic beats only. CONCLUSIONS: Routine, early ambulatory ECG monitoring in ED patients with unexplained syncope is probably warranted. A large-scale trial comparing this approach to standard care with cost-effectiveness and safety analysis is now required. TRIAL REGISTRATION: NCT02683174.


Asunto(s)
Electrocardiografía Ambulatoria/instrumentación , Servicio de Urgencia en Hospital , Síncope/diagnóstico , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cooperación del Paciente , Satisfacción del Paciente , Proyectos Piloto , Estudios Prospectivos , Escocia
7.
J Psychosom Res ; 72(6): 422-6, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22656437

RESUMEN

OBJECTIVE: Type D personality has been proposed as a risk factor for poor prognosis in cardiac patients. Recent studies which have adopted a dimensional approach to Type D (negative affectivity×social inhibition) found no effect of Type D on mortality, after controlling for its constituent elements. To-date, no study has determined if Type D is associated with psychosocial outcomes in post-myocardial infarction (MI) patients when conceptualised as a dimensional variable. METHODS: Participants were 192 MI patients (138 males, 54 females, mean age 66.0years) who provided demographic and clinical information, and completed measures of Type D one-week post-MI. Three months later, 131 of these MI patients completed measures of disability and quality of life. RESULTS: Using regression analyses, adjusted for demographic and clinical data, Type D emerged as a significant predictor of disability and quality of life in MI patients, when analysed using the traditional categorical approach. However, Type D did not predict disability and quality of life when it was analysed using the interaction of negative affectivity and social inhibition. Negative affect emerged as a significant predictor of both disability (ß=.433, t(130)=3.53, p<.01), and quality of life (ß=-.624, t(130)=-5.68, p<.001). CONCLUSIONS: The results suggest that Type D is not associated with short-term psychosocial outcome in MI patients, after controlling for its constituent elements. However, negative affect was significantly associated with both disability and quality of life. Future research should conceptualise Type D as the interaction between negative affectivity and social inhibition, rather than as a typology.


Asunto(s)
Infarto del Miocardio/psicología , Personalidad , Actividades Cotidianas/psicología , Adulto , Afecto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Relaciones Interpersonales , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Determinación de la Personalidad , Pronóstico , Calidad de Vida/psicología , Resultado del Tratamiento
8.
J Psychosom Res ; 70(2): 141-4, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21262416

RESUMEN

OBJECTIVES: To determine the relationship between Type D personality (the tendency to experience negative emotions and to be socially inhibited) and illness beliefs in postmyocardial infarction (MI) patients. METHODS: One hundred and ninety-two MI patients participated. Patients were assessed on demographic variables and completed the Type D Scale (DS14) and Brief Illness Perceptions Questionnaire one week post-MI. RESULTS: Multivariate analysis of variance revealed that Type D patients were significantly different from non-Type D patients on every illness perception dimension. Type D patients believe that their illness has significantly more serious consequences (P<.001), will last significantly longer (P<.001), will be significantly less controllable by them (P<.05) or through treatment (P<.001) compared to non-Type D patients, and experience significantly more symptoms that they attribute to their illness (P<.001). In addition, they are significantly more concerned about their illness (P<.05), experience significantly more emotions as a result (P<.001), and find their illness to be significantly less comprehensible compared to non-Type D individuals (P<.001). CONCLUSION: Type D individuals possess a distinct profile of illness beliefs, which may help explain the adverse effect of Type D on health outcomes following MI. Future research should evaluate intervention strategies to tackle illness perceptions in these high-risk patients.


Asunto(s)
Infarto del Miocardio/psicología , Percepción , Personalidad , Adulto , Anciano , Anciano de 80 o más Años , Actitud Frente a la Salud , Femenino , Humanos , Masculino , Persona de Mediana Edad , Inventario de Personalidad , Encuestas y Cuestionarios
10.
IEEE Trans Biomed Eng ; 55(11): 2658-65, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18990637

RESUMEN

Ventricular tachyarrhythmias are potentially lethal cardiac pathologies and the commonest cause of sudden cardiac death. Efforts to predict the onset of such events are based on feature extraction from the surface ECG. T-wave alternans (TWAs) are considered a marker of abnormal ventricular function that may be associated with ventricular tachycardia (VT) and ventricular fibrillation. A novel TWA detection algorithm utilizing the continuous wavelet transform is described in this paper. Simulated ECGs containing artificial TWA were used to test the algorithm that achieved a sensitivity of 91.40% and a specificity of 94.00%. The algorithm was subsequently used to analyze the ECGs of eight patients prior to the onset of VT. Of these, the algorithm indicated that five patients exhibited TWA prior to the onset of the tachyarrhythmic events, while the remaining three patients did not exhibit identifiable TWA. Healthy individuals were also studied in which one short TWA episode was detected by the algorithm. However, closer visual inspection of the data revealed this to be a likely false positive result.


Asunto(s)
Electrocardiografía/métodos , Modelos Cardiovasculares , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Algoritmos , Unidades de Cuidados Coronarios , Humanos , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador , Estadísticas no Paramétricas
11.
Heart ; 93(10): 1268-73, 2007 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-17502328

RESUMEN

BACKGROUND: More than 50% of patients initially resuscitated from out-of-hospital cardiac arrest die in hospital. OBJECTIVE: To investigate the prognostic value of serum protein S-100 and neuron-specific enolase (NSE) concentrations for predicting (a) memory impairment at discharge; (b) in-hospital death, after resuscitation from out-of-hospital cardiac arrest. METHODS: In a prospective study of 143 consecutive survivors of out-of-hospital cardiac arrest, serum samples were obtained within 12, 24-48 and 72-96 hours after the event. S-100 and NSE concentrations were measured. Pre-discharge cognitive assessment of patients (n = 49) was obtained by the Rivermead Behavioural Memory Test (RBMT). The relationship between biochemical brain marker concentrations and RBMT scores, and between marker concentrations and the risk of in-hospital death was examined. RESULTS: A moderate negative relationship was found between S-100 concentration and memory test score, at all time points. The relationship between NSE and memory test scores was weaker. An S-100 concentration >0.29 microg/l at time B predicted moderate to severe memory impairment with absolute specificity (42.8% sensitivity). S-100 remained an independent predictor of memory function after adjustment for clinical variables and cardiac arrest timing indices. NSE and S-100 concentrations were greater in patients who died than in those who survived, at all time points. Both NSE and S-100 remained predictors of in-hospital death after adjustment for clinical variables and cardiac arrest timing indices. The threshold concentrations yielding 100% specificity for in-hospital death were S-100: 1.20 microg/l (sensitivity 44.8%); NSE 71.0 microg/l (sensitivity 14.0%). CONCLUSIONS: Estimation of serum S-100 concentration after out-of-hospital cardiac arrest can be used to identify patients at risk of significant cognitive impairment at discharge. Serum S-100 and NSE concentrations measured 24-48 hours after cardiac arrest provide useful additional information.


Asunto(s)
Reanimación Cardiopulmonar/métodos , Paro Cardíaco/psicología , Trastornos de la Memoria/diagnóstico , Fosfopiruvato Hidratasa/metabolismo , Proteínas S100/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/metabolismo , Reanimación Cardiopulmonar/mortalidad , Coma/sangre , Servicios Médicos de Urgencia , Femenino , Paro Cardíaco/mortalidad , Paro Cardíaco/terapia , Mortalidad Hospitalaria , Humanos , Masculino , Trastornos de la Memoria/etiología , Trastornos de la Memoria/mortalidad , Persona de Mediana Edad , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Prospectivos
12.
J Clin Monit Comput ; 20(1): 33-6, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16532280

RESUMEN

OBJECTIVE: To determine if an automatic algorithm using wavelet analysis techniques can be used to reliably determine respiratory rate from the photoplethysmogram (PPG). METHODS: Photoplethysmograms were obtained from 12 spontaneously breathing healthy adult volunteers. Three related wavelet transforms were automatically polled to obtain a measure of respiratory rate. This was compared with a secondary timing signal obtained by asking the volunteers to actuate a small push button switch, held in their right hand, in synchronisation with their respiration. In addition, individual breaths were resolved using the wavelet-method to identify the source of any discrepancies. RESULTS: Volunteer respiratory rates varied from 6.56 to 18.89 breaths per minute. Through training of the algorithm it was possible to determine a respiratory rate for all 12 traces acquired during the study. The maximum error between the PPG derived rates and the manually determined rate was found to be 7.9%. CONCLUSION: Our technique allows the accurate measurement of respiratory rate from the photoplethysmogram, and leads the way for developing a simple non-invasive combined respiration and saturation monitor.


Asunto(s)
Algoritmos , Fotopletismografía/métodos , Mecánica Respiratoria/fisiología , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico/métodos , Oximetría/métodos , Sistemas de Atención de Punto
13.
Eur Heart J ; 27(4): 406-12, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16230307

RESUMEN

AIMS: To determine whether survival after discharge following pre-hospital cardiopulmonary arrest has improved. METHODS AND RESULTS: The Heartstart Register was used to identify all 1659 patients discharged alive from Scottish hospitals during 1991-01 following pre-hospital arrest due to cardiac aetiology. The cohort was split into tertiles using year of arrest. A Cox proportional hazards model was used to determine risk of death relative to 1991-93. Patients who survived cardiopulmonary arrest in 1997-01 were less likely to die from any cause (unadjusted HR 0.60, 95% CI 0.48-0.75, P<0.001) or cardiac disease (unadjusted HR 0.50, 95% CI 0.38-0.65, P<0.001). After adjustment for case-mix, there remained significant declines in all-cause (adjusted HR 0.62, 95% CI 0.50-0.78, P<0.001) and cardiac death (adjusted HR 0.52, 95% CI 0.39-0.68, P<0.001). Clinical management had improved, with increased use of thrombolysis (47-63%, chi2 trend, P<0.001), beta-blockers (28-53%, chi2 trend, P<0.001), ACE-inhibitors (48-69%, chi2 trend, P<0.001), and anti-thrombotics (79-88%, chi2 trend, P<001). Adjustment for recorded changes in management attenuated the decline in all-cause death (adjusted HR 0.77, 95% CI 0.60-0.98, P=0.03). CONCLUSION: Survival following cardiopulmonary arrest has improved after adjusting for changes in case-mix. Better clinical management has contributed to this improvement.


Asunto(s)
Enfermedad Coronaria/complicaciones , Paro Cardíaco/mortalidad , Anciano , Estudios de Cohortes , Enfermedad Coronaria/mortalidad , Desinstitucionalización/estadística & datos numéricos , Servicios Médicos de Urgencia/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Revascularización Miocárdica , Modelos de Riesgos Proporcionales , Sistema de Registros , Estudios Retrospectivos , Escocia/epidemiología , Factores Socioeconómicos , Análisis de Supervivencia
14.
J Invasive Cardiol ; 17(6): 338-9, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16003013

RESUMEN

Prolonged temporary pacing is associated with frequent complications. We describe a patient with aortic endocarditis and acquired tri-fascicular block in whom back-up pacing was indicated. Using a Seldinger technique via a subclavian approach, a permanent active-fixation lead was positioned in the right ventricle. The lead was tunnelled subcutaneously for 6 cm, and the proximal end was connected to a standard single chamber pulse generator. The procedure was well tolerated and over a period of four months there were no complications or infection. The PR interval subsequently reduced in duration to 200 ms and as no episodes of AV block had occurred, the lead was easily removed with retraction of the helix and gentle traction.


Asunto(s)
Enfermedades de la Aorta/terapia , Bloqueo de Rama/terapia , Estimulación Cardíaca Artificial/métodos , Endocarditis/terapia , Anciano , Humanos , Masculino , Factores de Tiempo
15.
Ann Noninvasive Electrocardiol ; 9(4): 316-22, 2004 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-15485508

RESUMEN

BACKGROUND: Wavelet-based methods of analyzing ECG signals have been used to identify specific features in cardiac arrhythmias. Since some of these features are rate dependent, it is a requirement that they are examined across a range of physiological heart rates. The wavelet transform is a signal analysis tool that can elucidate spectral and temporal information simultaneously from complex signals, including the ECG. The aim of this study was to identify the local frequency characteristics of the ECG using a real-time wavelet scalogram and to study the rate dependence of these features. METHODS: We examined the spectral temporal behavior of the local characteristics of the electrocardiogram (ECG) of 10 patients, in whom precise control of heart rate was achieved using right atrial pacing. Temporary reprogramming was used to adjust the paced atrial rate to predetermined values so that a rate-controlled rhythm was produced that closely resembled sinus rhythm. RESULTS: Rate-dependent features are seen on time-frequency scalograms. As the rate increases, the temporal spacing of features decrease and the frequency bands shift upward on the plot. Two patients with abnormal atrioventricular conduction demonstrate features of Wenckebach conduction and fusion. CONCLUSIONS: Characterization of the rate-dependent features of the ECG in a paced atrial rhythm by wavelet transform techniques has revealed some additional information not readily seen on single lead ECG analysis. This model provides a surrogate for changes that might be expected during rate changes in physiological sinus rhythm. It is envisaged that this method will offer advantages in detecting features of clinical significance that may not be readily seen by existing methods.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial , Electrocardiografía , Frecuencia Cardíaca/fisiología , Procesamiento de Señales Asistido por Computador , Arritmias Cardíacas/prevención & control , Análisis de Fourier , Humanos , Factores de Tiempo
16.
J Clin Monit Comput ; 18(5-6): 309-12, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15957620

RESUMEN

OBJECTIVES: To determine if wavelet analysis techniques can be used to reliably identify individual breaths from the photoplethysmogram (PPG). METHODS: Photoplethysmograms were obtained from 22 healthy adult volunteers timing their respiration rate in synchronisation with a metronome. A secondary timing signal was obtained by asking the volunteers to actuate a small push button switch, held in their right hand, in synchronisation with their respiration. Each PPG was analyzed using primary wavelet decomposition and two new, related, secondary decompositions to determine the accuracy of individual breath detection. RESULTS: The optimal breath capture was obtained by manually polling the three techniques, allowing detection of 466 out of the 472 breaths studied; a detection rate of 98.7% with no false positive breaths detected. CONCLUSION: Our technique allows the accurate capture of individual breaths from the photoplethysmogram, and leads the way for developing a simple non-invasive combined respiration and saturation monitor.


Asunto(s)
Algoritmos , Oximetría/métodos , Respiración , Humanos , Fotopletismografía , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Resuscitation ; 58(1): 73-9, 2003 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12867312

RESUMEN

OBJECTIVE: To assess the prevalence and severity of memory deficits in a group of patients who survived an in-hospital cardiac arrest (IHCA) in comparison with patients resuscitated after cardiac arrest outside hospital (OHCA) and patients with acute myocardial infarction (MI). SUBJECTS: Thirty-five IHCA survivors, 35 OHCA survivors, and 35 patients who had suffered MI uncomplicated by cardiac arrest. PROCEDURE: Participants were assessed 8.2 (4.5) months after the event for current affective state (Hospital anxiety and depression scale (HADS)), pre-morbid intelligence (National adult reading test (NART)), short-term memory (digit span test) and long-term episodic memory (Rivermead behavioural memory test-RBMT). RESULTS: IHCA patients scored lower on the RBMT than MI controls but did not score significantly differently OHCA patients. Moderate or severe memory impairment was found in 26% of the IHCA group and 38% of the OHCA group. None of the MI group was found to have this degree of impairment. This difference in prevalence of memory impairment between the two cardiac arrest groups was not statistically significant. However, both arrest groups had significantly greater memory impairment than the MI control group. CONCLUSIONS: Clinically important memory impairment was found in one in four patients surviving IHCA. The shorter arrest durations that are thought to be associated with IHCA may not be sufficient to protect patients from memory impairment associated with cerebral hypoxia.


Asunto(s)
Paro Cardíaco/complicaciones , Trastornos de la Memoria/etiología , Adolescente , Adulto , Anciano , Enfermedad Crónica , Servicios Médicos de Urgencia , Femenino , Hospitalización , Humanos , Hipoxia Encefálica/complicaciones , Masculino , Memoria a Corto Plazo , Persona de Mediana Edad , Infarto del Miocardio/complicaciones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...