Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMJ Open ; 11(3): e039396, 2021 03 17.
Artículo en Inglés | MEDLINE | ID: mdl-33737417

RESUMEN

INTRODUCTION: The optimal management of small-sized to medium-sized vestibular schwannoma (VS) is a matter of controversy. Clinical results of the prevailing treatment modalities (microsurgery, stereotactic radiosurgery (SRS), and conservative management (CM)) are documented, but comparative studies are few, and none are randomised or blinded. Upfront radiosurgery, or a careful follow-up by MRI with subsequent treatment on growth, are two strategies used at many centres. The present study aims at comparing these strategies by randomising individuals with newly diagnosed tumours to either upfront SRS or initial CM. METHODS AND ANALYSIS: The Vestibular Schwannoma: Radiosurgery or Expectation study is designed as a randomised, controlled, observer-blinded, single-centre superiority trial with two parallel groups. Eligible patients will be randomised using sequentially numbered opaque sealed envelopes, and the radiosurgery group will undergo standard Gamma Knife Radiosurgery (GKRS) within 2 months following randomisation. The primary endpoint is tumour growth measured as volume ratio V4years/Vbaseline and volume doubling time, evaluated by annual T1 contrast MRI volumetric analysis. Secondary endpoints include symptom and sign development measured by clinical examination, audiovestibular tests, and by patient's responses to standardised validated questionnaires. In addition, the patient's working status, and the health economics involved with both strategies will be evaluated and compared. All outcome assessments will be performed by blinded observers. Power analysis indicates that 100 patients is sufficient to demonstrate the effect of GKRS on tumour volume. ETHICS AND DISSEMINATION: The trial has ethical approval from the Regional Ethical Committee (23503) and funding from The Western Norway Regional Health Authority. Trial methods and results will be reported according to the Consolidated Standards of Reporting Trials 2010 guidelines in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: Clinical trials: NCT02249572. Haukeland University Hospital record: 2014/314. Regional Ethical Committee (REC West): 23 503. The Western Norway Regional Health Authority: 912 281.


Asunto(s)
Neuroma Acústico , Radiocirugia , Humanos , Motivación , Neuroma Acústico/diagnóstico por imagen , Neuroma Acústico/cirugía , Noruega , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento
2.
Neuroimage ; 189: 425-431, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30682536

RESUMEN

Spectral editing allows direct measurement of low-concentration metabolites, such as GABA, glutathione (GSH) and lactate (Lac), relevant for understanding brain (patho)physiology. The most widely used spectral editing technique is MEGA-PRESS, which has been diversely implemented across research sites and vendors, resulting in variations in the final resolved edited signal. In this paper, we describe an effort to develop a new universal MEGA-PRESS sequence with HERMES functionality for the major MR vendor platforms with standardized RF pulse shapes, durations, amplitudes and timings. New RF pulses were generated for the universal sequence. Phantom experiments were conducted on Philips, Siemens, GE and Canon 3 T MRI scanners using 32-channel head coils. In vivo experiments were performed on the same six subjects on Philips and Siemens scanners, and on two additional subjects, one on GE and one on Canon scanners. On each platform, edited MRS experiments were conducted with the vendor-native and universal MEGA-PRESS sequences for GABA (TE = 68 ms) and Lac editing (TE = 140 ms). Additionally, HERMES for GABA and GSH was performed using the universal sequence at TE = 80 ms. The universal sequence improves inter-vendor similarity of GABA-edited and Lac-edited MEGA-PRESS spectra. The universal HERMES sequence yields both GABA- and GSH-edited spectra with negligible levels of crosstalk on all four platforms, and with strong agreement among vendors for both edited spectra. In vivo GABA+/Cr, Lac/Cr and GSH/Cr ratios showed relatively low variation between scanners using the universal sequence. In conclusion, phantom and in vivo experiments demonstrate successful implementation of the universal sequence across all four major vendors, allowing editing of several metabolites across a range of TEs.


Asunto(s)
Encéfalo/diagnóstico por imagen , Encéfalo/metabolismo , Espectroscopía de Resonancia Magnética/métodos , Espectroscopía de Resonancia Magnética/normas , Adulto , Femenino , Glutatión/metabolismo , Humanos , Ácido Láctico/metabolismo , Espectroscopía de Resonancia Magnética/instrumentación , Masculino , Ácido gamma-Aminobutírico/metabolismo
3.
J Alzheimers Dis ; 66(2): 517-532, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30198874

RESUMEN

Molecular dynamics simulation and in vitro nuclear magnetic resonance (NMR) studies on glutathione (GSH) indicated existence of closed and extended conformations. The present work in a multi-center research setting reports in-depth analysis of GSH conformers in vivo using a common magnetic resonance spectroscopy (MRS) protocol and signal processing scheme. MEGA-PRESS pulse sequence was applied on healthy subjects using 3T Philips MRI scanner (India) and 3T GE MRI scanner (Norway) using the same experimental parameters (echo time, repetition time, and selective 180° refocusing ON-pulse at 4.40 ppm and 4.56 ppm). All MRS data were processed at one site National Brain Research Center (NBRC) using in-house MRS processing toolbox (KALPANA) for consistency. We have found that both the closed and extended GSH conformations are present in human brain and the relative proportion of individual conformer peak depends on the specific selection of refocusing ON-pulse position in MEGA-PRESS pulse sequence. It is important to emphasize that in vivo experiments with different refocusing and inversion pulse positions, echo time, and voxel size, clearly evidence the presence of both the GSH conformations. The GSH conformer peak positions for the closed GSH (Cys-Hß) peak at ∼2.80 ppm and extended GSH (Cys-Hß) peak at ∼2.95 ppm remain consistent irrespective of the selective refocusing OFF-pulse positions. This is the first in vivo study where both extended and closed GSH conformers are detected using the MEGA-PRESS sequence employing the parameters derived from the high resolution in vitro NMR studies on GSH.


Asunto(s)
Encéfalo/metabolismo , Glutatión/química , Glutatión/metabolismo , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Encéfalo/diagnóstico por imagen , Femenino , Voluntarios Sanos , Humanos , Procesamiento de Imagen Asistido por Computador , Técnicas In Vitro , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Masculino , Conformación Proteica , Tritio/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...