3.
JACC Cardiovasc Interv ; 12(6): 582-591, 2019 03 25.
Artículo en Inglés | MEDLINE | ID: mdl-30826230

RESUMEN

OBJECTIVES: The authors sought to define the feasibility and performance of 3-dimensional (3D) vena contracta area (VCA) measurement in evaluating total residual mitral regurgitation (MR) following percutaneous edge-to-edge clip (E-EC) mitral valve repair. BACKGROUND: Residual MR severity after percutaneous repair is not only a determinant of procedural success, but also a major prognostic factor. To date, no single echocardiographic method has been recommended for post-procedural MR quantification, with the evaluation currently relying on a complex, multiparametric appraisal. METHOD: The authors performed a retrospective study of patients undergoing the E-EC procedure, for which baseline and post-repair 3D color Doppler transesophageal echocardiogram datasets were available. Total VCA was recorded as the sum of individual VCAs (if more than 1) and compared with an expert multiparametric appraisal of MR severity as the reference standard. Receiver-operating characteristic analysis was performed. RESULTS: 155 patient studies were available for review. Total VCA correlated with hemodynamic parameters and was significantly reduced after E-EC. Receiver-operating characteristic analysis demonstrated a VCA threshold of 0.27 cm2 for identification of ≥moderate MR, with good diagnostic accuracy (area under the curve 0.81) and a negative predictive value of 92%. Smaller VCA was associated with clinical New York Heart Association functional class improvement at 30-day follow-up. CONCLUSIONS: Measurement of VCA is feasible using 3D color Doppler transesophageal echocardiography and provides reliable quantification of MR following E-EC transcatheter mitral valve repair.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Hemodinámica , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/efectos adversos , Anuloplastia de la Válvula Mitral/instrumentación , Insuficiencia de la Válvula Mitral/diagnóstico , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Texas , Resultado del Tratamiento , Washingtón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...