Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
J Clin Med ; 13(5)2024 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-38592046

RESUMEN

Atrial fibrillation (AF), the most common cardiac arrhythmia, is associated with adverse CV outcomes. Vascular aging (VA), which is defined as the progressive deterioration of arterial function and structure over a lifetime, is an independent predictor of both AF development and CV events. A timing identification and treatment of early VA has therefore the potential to reduce the risk of AF incidence and related CV events. A network of scientists and clinicians from the COST Action VascAgeNet identified five clinically and methodologically relevant questions regarding the relationship between AF and VA and conducted a narrative review of the literature to find potential answers. These are: (1) Are VA biomarkers associated with AF? (2) Does early VA predict AF occurrence better than chronological aging? (3) Is early VA a risk enhancer for the occurrence of CV events in AF patients? (4) Are devices measuring VA suitable to perform subclinical AF detection? (5) Does atrial-fibrillation-related rhythm irregularity have a negative impact on the measurement of vascular age? Results showed that VA is a powerful and independent predictor of AF incidence, however, its role as risk modifier for the occurrence of CV events in patients with AF is debatable. Limited and inconclusive data exist regarding the reliability of VA measurement in the presence of rhythm irregularities associated with AF. To date, no device is equipped with tools capable of detecting AF during VA measurements. This represents a missed opportunity to effectively perform CV prevention in people at high risk. Further advances are needed to fill knowledge gaps in this field.

2.
Eur Radiol ; 2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38183450

RESUMEN

OBJECTIVES: Partial thrombosis of the false lumen (FL) in patients with chronic aortic dissection (AD) of the descending aorta has been associated with poor outcomes. Meanwhile, the fluid dynamic and biomechanical characteristics associated with partial thrombosis remain to be elucidated. This retrospective, single-center study tested the association between FL fluid dynamics and biomechanics and the presence and extent of FL thrombus. METHODS: Patients with chronic non-thrombosed or partially thrombosed FLs in the descending aorta after an aortic dissection underwent computed tomography angiography, cardiovascular magnetic resonance (CMR) angiography, and a 4D flow CMR study. A comprehensive quantitative analysis was performed to test the association between FL thrombus presence and extent (percentage of FL with thrombus) and FL anatomy (diameter, entry tear location and size), fluid dynamics (inflow, rotational flow, wall shear stress, kinetic energy, and flow acceleration and stasis), and biomechanics (pulse wave velocity). RESULTS: Sixty-eight patients were included. In multivariate logistic regression FL kinetic energy (p = 0.038) discriminated the 33 patients with partial FL thrombosis from the 35 patients with no thrombosis. Similarly, in separated multivariate linear correlations kinetic energy (p = 0.006) and FL inflow (p = 0.002) were independently related to the extent of the thrombus. FL vortexes, flow acceleration and stasis, wall shear stress, and pulse wave velocity showed limited associations with thrombus presence and extent. CONCLUSION: In patients with chronic descending aorta dissection, false lumen kinetic energy is related to the presence and extent of false lumen thrombus. CLINICAL RELEVANCE STATEMENT: In patients with chronic aortic dissection of the descending aorta, false lumen hemodynamic parameters are closely linked with the presence and extent of false lumen thrombosis, and these non-invasive measures might be important in patient management. KEY POINTS: • Partial false lumen thrombosis has been associated with aortic growth in patients with chronic descending aortic dissection; therefore, the identification of prothrombotic flow conditions is desirable. • The presence of partial false lumen thrombosis as well as its extent was related with false lumen kinetic energy. • The assessment of false lumen hemodynamics may be important in the management of patients with chronic aortic dissection of the descending aorta.

3.
J Cardiovasc Magn Reson ; 26(1): 100992, 2024 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-38211655

RESUMEN

BACKGROUND: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA). METHODS: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained. RESULTS: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR). CONCLUSION: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.

4.
Hypertension ; 81(1): 183-192, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37975229

RESUMEN

BACKGROUND: Arterial stiffness, as measured by arterial pulse wave velocity (PWV), is an established biomarker for cardiovascular risk and target-organ damage in individuals with hypertension. With the emergence of new devices for assessing PWV, it has become evident that some of these devices yield results that display significant discrepancies compared with previous devices. This discrepancy underscores the importance of comprehensive validation procedures and the need for international recommendations. METHODS: A stepwise approach utilizing the modified Delphi technique, with the involvement of key scientific societies dedicated to arterial stiffness research worldwide, was adopted to formulate, through a multidisciplinary vision, a shared approach to the validation of noninvasive arterial PWV measurement devices. RESULTS: A set of recommendations has been developed, which aim to provide guidance to clinicians, researchers, and device manufacturers regarding the validation of new PWV measurement devices. The intention behind these recommendations is to ensure that the validation process can be conducted in a rigorous and consistent manner and to promote standardization and harmonization among PWV devices, thereby facilitating their widespread adoption in clinical practice. CONCLUSIONS: It is hoped that these recommendations will encourage both users and developers of PWV measurement devices to critically evaluate and validate their technologies, ultimately leading to improved consistency and comparability of results. This, in turn, will enhance the clinical utility of PWV as a valuable tool for assessing arterial stiffness and informing cardiovascular risk stratification and management in individuals with hypertension.


Asunto(s)
Hipertensión , Rigidez Vascular , Humanos , Análisis de la Onda del Pulso/métodos , Presión Arterial , Hipertensión/diagnóstico , Arterias
6.
Artículo en Inglés | MEDLINE | ID: mdl-37490995

RESUMEN

BACKGROUND: Blunt traumatic thoracic aortic injuries (BTAIs) are associated with a high mortality rate. Thoracic endovascular aortic repair (TEVAR) is the most frequently used surgical strategy in patients with BTAI, as it offers good short- and middle-term results. Previous studies have reported an abnormally high prevalence of hypertension (HT) in these patients. This work aimed to describe the long-term prevalence of HT and provide a comprehensive evaluation of the biomechanical, clinical, and functional factors involved in HT development. METHODS: Twenty-six patients treated with TEVAR following BTAI with no history of HT at the time of trauma were enrolled. They were matched with 37 healthy volunteers based on age, sex, and body surface area and underwent a comprehensive follow-up study, including cardiovascular magnetic resonance, 24-hour ambulatory blood pressure monitoring, and assessment of carotid-femoral pulse wave velocity (cfPWV, a measure of aortic stiffness) and flow-mediated vasodilation. RESULTS: The mean patient age was 43.5 ± 12.9 years, and the majority were male (23 of 26; 88.5%). At a mean of 120.2 ± 69.7 months after intervention, 17 patients (65%) presented with HT, 14 (54%) had abnormal nighttime blood pressure dipping, and 6 (23%) high cfPWV. New-onset HT was related to a more proximal TEVAR landing zone and greater distal oversizing. Abnormal nighttime blood pressure was related to high cfPWV, which in turn was associated with TEVAR length and premature arterial aging. CONCLUSIONS: HT frequently occurs otherwise healthy subjects undergoing TEVAR implantation after BTAI. TEVAR stiffness and length, the proximal landing zone, and distal oversizing are potentially modifiable surgical characteristics related to abnormal blood pressure.

7.
J Am Coll Cardiol ; 82(5): 448-464, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37495282

RESUMEN

Bicuspid aortic valve is the most common congenital heart disease and exposes patients to an increased risk of aortic dilation and dissection. Aortic dilation is a slow, silent process, leading to a greater risk of aortic dissection. The prevention of adverse events together with optimization of the frequency of the required lifelong imaging surveillance are important for both clinicians and patients and motivated extensive research to shed light on the physiopathologic processes involved in bicuspid aortic valve aortopathy. Two main research hypotheses have been consolidated in the last decade: one supports a genetic basis for the increased prevalence of dilation, in particular for the aortic root, and the second supports the damaging impact on the aortic wall of altered flow dynamics associated with these structurally abnormal valves, particularly significant in the ascending aorta. Current opinion tends to rule out mutually excluding causative mechanisms, recognizing both as important and potentially clinically relevant.


Asunto(s)
Enfermedades de la Aorta , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/epidemiología , Dilatación , Enfermedades de la Aorta/complicaciones
8.
J Ultrasound Med ; 42(10): 2183-2213, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37148467

RESUMEN

Non-invasive ultrasound (US) imaging enables the assessment of the properties of superficial blood vessels. Various modes can be used for vascular characteristics analysis, ranging from radiofrequency (RF) data, Doppler- and standard B/M-mode imaging, to more recent ultra-high frequency and ultrafast techniques. The aim of the present work was to provide an overview of the current state-of-the-art non-invasive US technologies and corresponding vascular ageing characteristics from a technological perspective. Following an introduction about the basic concepts of the US technique, the characteristics considered in this review are clustered into: 1) vessel wall structure; 2) dynamic elastic properties, and 3) reactive vessel properties. The overview shows that ultrasound is a versatile, non-invasive, and safe imaging technique that can be adopted for obtaining information about function, structure, and reactivity in superficial arteries. The most suitable setting for a specific application must be selected according to spatial and temporal resolution requirements. The usefulness of standardization in the validation process and performance metric adoption emerges. Computer-based techniques should always be preferred to manual measures, as long as the algorithms and learning procedures are transparent and well described, and the performance leads to better results. Identification of a minimal clinically important difference is a crucial point for drawing conclusions regarding robustness of the techniques and for the translation into practice of any biomarker.


Asunto(s)
Arterias , Ultrasonografía Doppler , Humanos , Ultrasonografía/métodos , Arterias/diagnóstico por imagen , Algoritmos , Tecnología
9.
Nat Commun ; 14(1): 2350, 2023 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-37169737

RESUMEN

The p140Cap adaptor protein is a tumor suppressor in breast cancer associated with a favorable prognosis. Here we highlight a function of p140Cap in orchestrating local and systemic tumor-extrinsic events that eventually result in inhibition of the polymorphonuclear myeloid-derived suppressor cell function in creating an immunosuppressive tumor-promoting environment in the primary tumor, and premetastatic niches at distant sites. Integrative transcriptomic and preclinical studies unravel that p140Cap controls an epistatic axis where, through the upstream inhibition of ß-Catenin, it restricts tumorigenicity and self-renewal of tumor-initiating cells limiting the release of the inflammatory cytokine G-CSF, required for polymorphonuclear myeloid-derived suppressor cells to exert their local and systemic tumor conducive function. Mechanistically, p140Cap inhibition of ß-Catenin depends on its ability to localize in and stabilize the ß-Catenin destruction complex, promoting enhanced ß-Catenin inactivation. Clinical studies in women show that low p140Cap expression correlates with reduced presence of tumor-infiltrating lymphocytes and more aggressive tumor types in a large cohort of real-life female breast cancer patients, highlighting the potential of p140Cap as a biomarker for therapeutic intervention targeting the ß-Catenin/ Tumor-initiating cells /G-CSF/ polymorphonuclear myeloid-derived suppressor cell axis to restore an efficient anti-tumor immune response.


Asunto(s)
Neoplasias de la Mama , Femenino , Humanos , beta Catenina/metabolismo , Mama/patología , Neoplasias de la Mama/genética , Neoplasias de la Mama/inmunología , Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/patología , Línea Celular Tumoral , Inmunidad , Células Madre Neoplásicas/inmunología , Células Madre Neoplásicas/metabolismo
10.
J Am Heart Assoc ; 12(10): e027414, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37183857

RESUMEN

Magnetic resonance imaging and computed tomography allow the characterization of arterial state and function with high confidence and thus play a key role in the understanding of arterial aging and its translation into the clinic. Decades of research into the development of innovative imaging sequences and image analysis techniques have led to the identification of a large number of potential biomarkers, some bringing improvement in basic science, others in clinical practice. Nonetheless, the complexity of some of these biomarkers and the image analysis techniques required for their computation hamper their widespread use. In this narrative review, current biomarkers related to aging of the aorta, their founding principles, the sequence, and postprocessing required, and their predictive values for cardiovascular events are summarized. For each biomarker a summary of reference values and reproducibility studies and limitations is provided. The present review, developed in the COST Action VascAgeNet, aims to guide clinicians and technical researchers in the critical understanding of the possibilities offered by these advanced imaging modalities for studying the state and function of the aorta, and their possible clinically relevant relationships with aging.


Asunto(s)
Arterias , Imagen por Resonancia Magnética , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Biomarcadores
11.
Eur Heart J Cardiovasc Imaging ; 24(8): 1120-1128, 2023 07 24.
Artículo en Inglés | MEDLINE | ID: mdl-37131301

RESUMEN

AIMS: To assess the progression of the disease and evolution of the main echocardiographic variables for quantifying AS in patients with severe low-flow low-gradient (LFLG) AS compared to other severe AS subtypes. METHODS AND RESULTS: Longitudinal, observational, multicenter study including consecutive asymptomatic patients with severe AS (aortic valve area, AVA < 1.0 cm²) and normal left ventricle ejection fraction (LVEF ≥ 50%). Patients were classified according to baseline echocardiography into: HG (high gradient; mean gradient ≥ 40 mmHg), NFLG (normal-flow low-gradient; mean gradient < 40 mmHg, indexed systolic volume (SVi) > 35mL/m2), or LFLG (mean gradient < 40 mmHg, SVi ≤ 35 mL/m²). AS progression was analyzed by comparing patients' baseline measurements and their last follow-up measurements or those taken prior to aortic valve replacement (AVR). Of the 903 included patients, 401 (44.4%) were HG, 405 (44.9%) NFLG, and 97 (10.7%) LFLG. Progression of the mean gradient in a linear mixed regression model was greater in low-gradient groups: LFLG vs. HG (regression coefficient 0.124, P = 0.005) and NFLG vs. HG (regression coefficient 0.068, P = 0.018). No differences were observed between the LFLG and NFLG groups (regression coefficient 0.056, P = 0.195). However, AVA reduction was slower in the LFLG group compared to the NFLG (P < 0.001). During follow-up, in conservatively-managed patients, 19.1% (n = 9) of LFLG patients evolved to having NFLG AS and 44.7% (n = 21) to having HG AS. In patients undergoing AVR, 58.0% (n = 29) of LFLG baseline patients received AVR with a HG AS. CONCLUSION: LFLG AS shows an intermediate AVA and gradient progression compared to NFLG and HG AS. The majority of patients initially classified as having LFLG AS changed over time to having other severe forms of AS, and most of them received AVR with a HG AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Válvula Aórtica/diagnóstico por imagen , Función Ventricular Izquierda , Volumen Sistólico , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Estudios Retrospectivos
12.
Heart ; 109(15): 1153-1158, 2023 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-37147129

RESUMEN

OBJECTIVES: To describe the aortic-related risks associated with pregnancy in women with bicuspid aortic valve (BAV) and to evaluate changes in aortic diameter in pregnancy. METHODS: Prospective observational study of patients with BAV from a single-site registry of pregnant women with structural heart disease between 2013 and 2020. Cardiac, obstetric and neonatal outcomes were studied. An assessment of aortic dimensions was performed during pregnancy by two-dimensional echocardiography. Aortic diameters were measured at the annulus, root, sinotubular junction and maximum ascending aorta diameter, and the largest diameter was used. Measurements of the aorta were made using the end-diastolic leading edge-to-leading edge convention. RESULTS: Forty-three women (32.9 years, IQR 29.6-35.3) with BAV were included: 9 (20.9%) had repaired aortic coarctation; 23 (53.5%) had moderate or severe aortic valve disease; 5 (11.6%) had a bioprosthetic aortic valve; and 2 (4.7%) had a mechanical prosthetic aortic valve. Twenty (47.0%) were nulliparous. The mean aortic diameter in the first trimester was 38.5 (SD 4.9) mm, and that in the third trimester was 38.4 (SD 4.8) mm. Forty (93.0%) women had an aortic diameter of <45 mm; 3 (7.0%) had 45-50 mm; and none had >50 mm. Three women (6.9%) with BAV presented cardiovascular complications during pregnancy or the postpartum period (two prosthetic thrombosis and one heart failure). No aortic complications were reported. There was a small but significant increase in aortic diameter during pregnancy (third trimester vs first trimester, 0.52 (SD 1.08) mm; p=0.03). Obstetric complications appeared in seven (16.3%) of pregnancies, and there were no maternal deaths. Vaginal non-instrumental delivery was performed in 21 (51.2%) out of 41 cases. There were no neonatal deaths, and the mean newborn weight was 3130 g (95% CI 2652 to 3380). CONCLUSIONS: Pregnancy in BAV women had a low rate of cardiac complications with no aortic complications observed in a small study group. Neither aortic dissection nor need for aortic surgery was reported. A low but significant aortic growth was observed during pregnancy. Although requiring follow-up, the risk of aortic complications in pregnant women with BAV and aortic diameters of <45 mm at baseline is low.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Embarazo , Recién Nacido , Humanos , Femenino , Masculino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Aorta/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos
13.
J Hum Hypertens ; 37(8): 634-643, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37061653

RESUMEN

Blood pressure and vascular ageing trajectories differ between men and women. These differences develop due to sex-related factors, attributable to sex chromosomes or sex hormones, and due to gender-related factors, mainly related to different sociocultural behaviors. The present review summarizes the relevant facts regarding gender-related differences in vascular function in hypertension. Among sex-related factors, endogenous 17ß-estradiol plays a key role in protecting pre-menopausal women from vascular ageing. However, as vascular ageing (preceding and inducing hypertension) has a steeper increase in women than in men starting already from the third decade, it is likely that gender-related factors play a prominent role, especially in the young. Among gender-related factors, psychological stress (including that one related to gender-based violence and discrimination), depression, some psychological traits, but also low socioeconomic status, are more common in women than men, and their impact on vascular ageing is likely to be greater in women. Men, on the contrary, are more exposed to the vascular adverse consequences of alcohol consumption, as well as of social deprivation, while "toxic masculinity" traits may result in lower adherence to lifestyle and preventive strategies. Unhealthy diet habits are more prevalent in men and smoking is equally prevalent in the two sexes, but have a disproportional negative effect on women's vascular health. In conclusion, given the major and complex role of gender-related factors in driving vascular alterations and blood pressure patterns, gender dimension should be systematically integrated into future research on vascular function and hypertension and to tailor cardiovascular prevention strategies.


Asunto(s)
Hipertensión , Salud de la Mujer , Masculino , Humanos , Femenino , Hipertensión/epidemiología , Fumar , Envejecimiento , Conducta Sexual , Factores Sexuales
14.
IEEE J Biomed Health Inform ; 27(7): 3302-3313, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37067963

RESUMEN

In recent years, several deep learning models have been proposed to accurately quantify and diagnose cardiac pathologies. These automated tools heavily rely on the accurate segmentation of cardiac structures in MRI images. However, segmentation of the right ventricle is challenging due to its highly complex shape and ill-defined borders. Hence, there is a need for new methods to handle such structure's geometrical and textural complexities, notably in the presence of pathologies such as Dilated Right Ventricle, Tricuspid Regurgitation, Arrhythmogenesis, Tetralogy of Fallot, and Inter-atrial Communication. The last MICCAI challenge on right ventricle segmentation was held in 2012 and included only 48 cases from a single clinical center. As part of the 12th Workshop on Statistical Atlases and Computational Models of the Heart (STACOM 2021), the M&Ms-2 challenge was organized to promote the interest of the research community around right ventricle segmentation in multi-disease, multi-view, and multi-center cardiac MRI. Three hundred sixty CMR cases, including short-axis and long-axis 4-chamber views, were collected from three Spanish hospitals using nine different scanners from three different vendors, and included a diverse set of right and left ventricle pathologies. The solutions provided by the participants show that nnU-Net achieved the best results overall. However, multi-view approaches were able to capture additional information, highlighting the need to integrate multiple cardiac diseases, views, scanners, and acquisition protocols to produce reliable automatic cardiac segmentation algorithms.


Asunto(s)
Aprendizaje Profundo , Ventrículos Cardíacos , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Algoritmos , Atrios Cardíacos
16.
Am J Physiol Heart Circ Physiol ; 325(1): H1-H29, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37000606

RESUMEN

Arterial pulse waves (PWs) such as blood pressure and photoplethysmogram (PPG) signals contain a wealth of information on the cardiovascular (CV) system that can be exploited to assess vascular age and identify individuals at elevated CV risk. We review the possibilities, limitations, complementarity, and differences of reduced-order, biophysical models of arterial PW propagation, as well as theoretical and empirical methods for analyzing PW signals and extracting clinically relevant information for vascular age assessment. We provide detailed mathematical derivations of these models and theoretical methods, showing how they are related to each other. Finally, we outline directions for future research to realize the potential of modeling and analysis of PW signals for accurate assessment of vascular age in both the clinic and in daily life.


Asunto(s)
Arterias , Fotopletismografía , Humanos , Arterias/fisiología , Fotopletismografía/métodos , Análisis de la Onda del Pulso , Modelos Cardiovasculares
18.
Eur J Prev Cardiol ; 30(11): 1101-1117, 2023 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-36738307

RESUMEN

Prevention of cardiovascular disease (CVD) remains one of the largest public health challenges of our time. Identifying individuals at increased cardiovascular risk at an asymptomatic, sub-clinical stage is of paramount importance for minimizing disease progression as well as the substantial health and economic burden associated with overt CVD. Vascular ageing (VA) involves the deterioration in vascular structure and function over time and ultimately leads to damage in the heart, brain, kidney, and other organs. Vascular ageing encompasses the cumulative effect of all cardiovascular risk factors on the arterial wall over the life course and thus may help identify those at elevated cardiovascular risk, early in disease development. Although the concept of VA is gaining interest clinically, it is seldom measured in routine clinical practice due to lack of consensus on how to characterize VA as physiological vs. pathological and various practical issues. In this state-of-the-art review and as a network of scientists, clinicians, engineers, and industry partners with expertise in VA, we address six questions related to VA in an attempt to increase knowledge among the broader medical community and move the routine measurement of VA a little closer from bench towards bedside.


Asunto(s)
Enfermedades Cardiovasculares , Humanos , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/prevención & control , Arterias , Envejecimiento
19.
Minerva Pediatr (Torino) ; 75(2): 197-200, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-28922908

RESUMEN

BACKGROUND: The majority of internationally adopted children, before adoption, might have experienced malnutrition, exposure to infectious diseases, environmental deprivation, and neglect; they could also develop medical problems such as vitamin D deficiency. Scantly data are available about vitamin D status in internationally adopted children and, to our knowledge, no report exists on Italian adoptees. METHODS: We carried out a prospective multicenter study, involving three Pediatric Centers in Piedmont, Italy, to collect information about 25-hydroxyvitamin D (25[OH]D) profile in adoptees, shortly after their arrival in Italy. RESULTS: In 142/158 internationally adopted children 25(OH)D was measured: 75 males and 67 females, with a mean age of 4.22±2.2 years. Fifty-three (37.3%) of them came from Asia, 48 (33.8%) from Africa, 24 (16.9%) from Eastern Europe, and 17 (12%) from Latin America. The median level of 25(OH)D in serum was 21.5 ng/mL (IQR range 14.3-29.7 ng/mL): 26 (18.2%) of the examined children had an insufficiency of 25-OHD, whereas 36 (25.2%) had a deficiency. Adoptees with longer time of institution stay had a significant risk to develop 25(OH)D deficiency. The Asian origin proved to be a risk factor to develop 25(OH)D deficiency, whereas the age >1 year was significantly associated with 25(OH)D insufficiency. CONCLUSIONS: Our survey showed that vitamin D deficiency and insufficiency, in internationally adoptees, are frequent and relevant health problems.


Asunto(s)
Niño Adoptado , Deficiencia de Vitamina D , Niño , Femenino , Masculino , Humanos , Preescolar , Estudios Prospectivos , Vitamina D , Vitaminas , Deficiencia de Vitamina D/epidemiología , Italia/epidemiología
20.
IEEE Trans Biomed Eng ; 70(3): 1095-1104, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36155431

RESUMEN

OBJECTIVE: The need for distilling the hemodynamic complexity of aortic flows into clinically relevant quantities resulted in a loss of the information hidden in 4D aortic fluid structures. To reduce information loss, this study proposes a network-based approach to identify and characterize in vivo the large-scale coherent motion of blood in the healthy human aorta. METHODS: The quantitative paradigm of the aortic flow as a "social network" was applied on 4D flow MRI acquisitions performed on forty-one healthy volunteers. Correlations between the aortic blood flow rate waveform at the proximal ascending aorta (AAo), assumed as one of the drivers of aortic hemodynamics, and the waveforms of the axial velocity in the whole aorta were used to build "one-to-all" networks. The impact of the driving flow rate waveform and of aortic geometric attributes on the transport of large-scale coherent fluid structures was investigated. RESULTS: The anatomical length of persistence of large-scale coherent motion was the 29.6% of the healthy thoracic aorta length (median value, IQR 23.1%-33.9%). Such length is significantly influenced by the average and peak-to-peak AAo blood flow rate values, suggesting a remarkable inertial effect of the AAo flow rate on the transport of large-scale fluid structures in the distal aorta. Aortic geometric attributes such as curvature, torsion and arch shape did not influence the anatomical length of persistence. CONCLUSION: The proposed in vivo approach allowed to quantitatively characterize the transport of large-scale fluid structures in the healthy aorta, strengthening the definition of coherent hemodynamic structures and identifying flow inertia rather than geometry as one of its main determinants. SIGNIFICANCE: The findings on healthy aortas may be used as reference values to investigate the impact of aortic disease or implanted devices in disrupting/restoring the physiological spatiotemporal coherence of large-scale aortic flow.


Asunto(s)
Aorta , Válvula Aórtica , Humanos , Velocidad del Flujo Sanguíneo , Aorta/diagnóstico por imagen , Imagen por Resonancia Magnética , Aorta Torácica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...