Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Front Vet Sci ; 10: 1238549, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37781276

RESUMEN

Objective: This study investigated the performance among four cardiac output (CO) monitoring techniques in comparison with the reference method intermittent pulmonary artery thermodilution (iPATD) and their ability to diagnose fluid responsiveness (FR) during a modified passive leg raise (PLRM) maneuver in isoflurane-anesthetized dogs undergoing acute blood volume manipulations. The study also examined the simultaneous effect of performing the PLRM on dynamic variables such as stroke distance variation (SDV), peak velocity variation (PVV), and stroke volume variation (SVV). Study design: Prospective, nonrandomized, crossover design. Study animals: Six healthy male Beagle dogs. Methods: The dogs were anesthetized with propofol and isoflurane and mechanically ventilated under neuromuscular blockade. After instrumentation, they underwent a series of sequential, nonrandomized steps: Step 1: baseline data collection; Step 2: removal of 33 mL kg-1 of circulating blood volume; Step 3: blood re-transfusion; and Step 4: infusion of 20 mL kg-1 colloid solution. Following a 10-min stabilization period after each step, CO measurements were recorded using esophageal Doppler (EDCO), transesophageal echocardiography (TEECO), arterial pressure waveform analysis (APWACO), and electrical cardiometry (ECCO). Additionally, SDV, PVV, and SVV were recorded. Intermittent pulmonary artery thermodilution (iPATDCO) measurements were also recorded before, during, and after the PLRM maneuver. A successful FR diagnosis made using a specific test indicated that CO increased by more than 15% during the PLRM maneuver. Statistical analysis was performed using one-way analysis of variance for repeated measures with post hoc Tukey test, linear regression, Lin's concordance correlation coefficient (ρc), and Bland-Altman analysis. Statistical significance was set at p < 0.05. Results: All techniques detected a reduction in CO (p < 0.001) during hemorrhage and an increase in CO after blood re-transfusion and colloid infusion (p < 0.001) compared with baseline. During hemorrhage, CO increases with the PLRM maneuver were as follows: 33% for iPATD (p < 0.001), 19% for EC (p = 0.03), 7% for APWA (p = 0.97), 39% for TEE (p < 0.001), and 17% for ED (p = 0.02). Concurrently, decreases in SVV, SDV, and PVV values (p < 0.001) were also observed. The percentage error for TEE, ED, and EC was less than 30% but exceeded 55% for APWA. While TEECO and ECCO slightly underestimated iPATDCO values, EDCO and APWACO significantly overestimated iPATDCO values. TEE and EC exhibited good and acceptable agreement with iPATD. However, CO measurements using all four techniques and iPATD did not differ before, during, and after PLRM at baseline, blood re-transfusion, and colloid infusion. Conclusion and clinical relevance: iPATD, EC, TEE, and ED effectively assessed FR in hypovolemic dogs during the PLRM maneuver, while the performance of APWA was unacceptable and not recommended. SVV, SDV, and PVV could be used to monitor CO changes during PLRM and acute blood volume manipulations, suggesting their potential clinical utility.

3.
Animals (Basel) ; 13(16)2023 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-37627465

RESUMEN

Isoflurane is a commonly used inhalation anesthetic in species undergoing veterinary care that induces hypotension, impacting organ perfusion, making it imperative to minimize its occurrence or identify effective strategies for treating it. This study evaluated and compared the hemodynamic effects of DOB, NEP, VAS, and HES in twelve isoflurane-anesthetized Beagle dogs. The order of the first three treatments was randomized. HES was administered last. Data were collected before treatments (baseline) and after 10 min of a sustained MAP of <45 mmHg induced by a high end-tidal isoflurane concentration (T0). Once treatment was initiated and the target MAP was achieved (65 to 80 mmHg) or the maximum dose reached, data were collected after 15 min of stabilization (T1) and 15 min after (T2). A 15 min washout period with a MAP of ≥65 mmHg was allowed between treatments. The intravenous dosage regimens started and were increased by 50% every five minutes until the target MAP or maximum dose was reached. The dosages were as follows: DOB, 5-15 µg/kg/min; NEP, 0.1-2 µg/kg/min; VAS, 0.5-5 mU/kg/min; and HET, 6% 1-20 mL/kg/min. DOB improved CO, DO2, and VO2, but reduced SVR. VAS elevated SVR, but decreased CO, DO2, and VO2. HES minimally changed BP and mildly augmented CO, DO2, and VO2. These treatments failed to reach the target MAP. NEP increased the arterial BP, CO, MPAP, and PAWP, but reduced HR. Norepinephrine infusion at 0.44 ± 0.19 µg/kg/min was the most efficient therapy for correcting isoflurane-induced hypotension.

4.
Animals (Basel) ; 13(14)2023 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-37508139

RESUMEN

Numerous cardiac output (CO) technologies were developed to replace the 'gold standard' pulmonary artery thermodilution due to its invasiveness and the risks associated with it. Minimally invasive lithium dilution (LiD) shows excellent agreement with thermodilution and can be used as a reference standard in animals. This study evaluated CO via noninvasive electrical cardiometry (EC) and acquired hemodynamic variables against CO measured using LiD in six healthy, anesthetized dogs administered different treatments (dobutamine, esmolol, phenylephrine, and high-dose isoflurane) impacting CO values. These treatments were chosen to cause drastic variations in CO, so that fair comparisons between EC and LiD across a wide range of CO values (low, intermediate, and high) could be made. Statistical analysis included linear regression, Bland-Altman plots, Lin's concordance correlation coefficient (ρc), and polar plots. Values of p < 0.05 represented significance. Good agreement was observed between EC and LiD, but consistent underestimation was noted when the CO values were high. The good trending ability, ρc of 0.88, and low percentage error of ±31% signified EC's favorable performance. Other EC-acquired variables successfully tracked changes in CO measured using LiD. EC may be a pivotal hemodynamic tool for continuously monitoring circulatory changes, as well as guiding and treating cardiovascular anesthetic complications in clinical settings.

5.
Am J Vet Res ; 84(8)2023 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-37385599

RESUMEN

OBJECTIVE: To compare cardiac output (CO) measurements by transesophageal echocardiography (TEECO) and esophageal Doppler monitor (EDMCO) with pulmonary artery thermodilution (PATDCO) in anesthetized dogs subjected to pharmacological interventions. The effect of treatments on EDM-derived indexes was also investigated. ANIMALS: 6 healthy male dogs (10.8 ± 0.7 kg). METHODS: Dogs were anesthetized with propofol and isoflurane, mechanically ventilated, and monitored with invasive mean arterial pressure (MAP), end-tidal isoflurane concentration (ETISO), PATDCO, TEECO, EDMCO, and EDM-derived indexes. Four treatments were administered to all dogs by randomization. Baseline data were collected before each treatment: (1) dobutamine infusion; (2) esmolol infusion; (3) phenylephrine infusion; and (4) ETISO > 3%. Data were collected after 10-minute stabilization and after 30 minutes of washout between treatments. Statistical tests were pairwise t test, Bland-Altman analysis, Lin's concordance correlation (ρc), and polar plot analysis with P < .05 set as significance. RESULTS: The mean ± SD relative bias (limits of agreement) for TEECO was 0.35 ± 25.2% (-49.1% to 49.8%) and for EDMCO was -27.2 ± 22.5% (-71.4% to 17%) versus PATDCO. The percent error for TEECO and EDMCO was 27.6% and 44.1%, respectively. The ρc value was 0.82 for TEECO and 0.66 for EDMCO. TEECO and EDMCO showed good trending ability. EDM-derived indexes displayed significant changes specific to the drug administered (P < .001). CLINICAL RELEVANCE: For minimally invasive CO monitoring, TEE may provide more favorable performance than EDM in clinical settings; however, EDM-derived indexes yield valuable hemodynamic information that reliably follows trends in CO, thus supporting critical decision-making in canine patients.


Asunto(s)
Isoflurano , Arteria Pulmonar , Masculino , Perros , Animales , Arteria Pulmonar/diagnóstico por imagen , Gasto Cardíaco , Ecocardiografía Transesofágica/veterinaria , Isoflurano/farmacología , Termodilución/veterinaria , Hemodinámica , Reproducibilidad de los Resultados
7.
Animals (Basel) ; 13(8)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37106987

RESUMEN

In animals, invasive pulmonary artery thermodilution (PATD) is a gold standard for cardiac output (CO) monitoring, but it is impractical in clinical settings. This study evaluates the agreement between PATD and noninvasive electrical cardiometry (EC) for measuring CO and analyzes the other EC-derived hemodynamic variables in six healthy anesthetized dogs subjected to four different hemodynamic events in a sequential order: (1) euvolemia (baseline); (2) hemorrhage (33% blood volume loss); (3) autologous blood transfusion; and (4) 20 mL/kg colloid bolus. The CO measurements obtained using PATD and EC are compared using Bland-Altman analysis, Lin's concordance correlation (LCC), and polar plot analysis. Values of p < 0.05 are considered significant. The EC measurements consistently underpredict the CO values as compared with PATD, and the LCC is 0.65. The EC's performance is better during hemorrhage, thus indicating its capability in detecting absolute hypovolemia in clinical settings. Even though the percentage error exhibited by EC is 49.4%, which is higher than the standard (<30%), EC displays a good trending ability. Additionally, the EC-derived variables display a significant correlation with the CO measured using PATD. Noninvasive EC may have a potential in monitoring trends in hemodynamics in clinical settings.

8.
Vet Anaesth Analg ; 50(3): 211-219, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36967326

RESUMEN

OBJECTIVE: To demonstrate if modified passive leg raise (PLRM) maneuver can be used for volumetric evaluation of fluid responsiveness (FR) by inducing cardiac output (CO) changes during experimental induction and correction of hypovolemia in healthy anesthetized dogs. The effects of PLRM on plethysmographic variability index (PVI) and pulse pressure variation (PPV) were also investigated. STUDY DESIGN: Prospective, crossover study. ANIMALS: A total of six healthy anesthetized Beagle dogs. METHODS: Dogs were anesthetized with propofol and isoflurane. They were mechanically ventilated under neuromuscular blockade, and normothermia was maintained. After instrumentation, all dogs were subjected to four stages: 1, baseline; 2, removal of 27 mL kg-1 circulating blood volume; 3, after blood re-transfusion; and 4, after 20 mL kg-1 hetastarch infusion over 20 minutes. A 10 minute stabilization period was allowed after induction of each stage and before data collection. At each stage, CO via pulmonary artery thermodilution, PVI, PPV and cardiopulmonary variables were measured before, during and after the PLRM maneuver. Stages were sequential, not randomized. Statistical analysis included repeated measures anova and Tukey's post hoc test, considering p < 0.05 as significant. RESULTS: During stage 2, PLRM at a 30° angle significantly increased CO (mean ± standard deviation, 1.0 ± 0.1 to 1.3 ± 0.1 L minute-1; p < 0.001), with a simultaneous significant reduction in PVI (38 ± 4% to 21 ± 4%; p < 0.001) and PPV (27 ± 2% to 18 ± 2%; p < 0.001). The PLRM did not affect CO, PPV and PVI during stages 1, 3 and 4. CONCLUSIONS AND CLINICAL RELEVANCE: In anesthetized dogs, PLRM at a 30° angle successfully detected FR during hypovolemia, and identified fluid nonresponsiveness during normovolemia and hypervolemia. Also, in hypovolemic dogs, significant decreases in PVI and PPV occurred in response to PLRM maneuver.


Asunto(s)
Anestésicos por Inhalación , Enfermedades de los Perros , Perros , Animales , Hipovolemia/terapia , Hipovolemia/veterinaria , Hemodinámica , Anestésicos por Inhalación/farmacología , Estudios Prospectivos , Estudios Cruzados , Presión Sanguínea
9.
Am J Vet Res ; 84(3)2023 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-36716127

RESUMEN

OBJECTIVE: To investigate the relationship between invasively measured stroke volume (SV) and (1) esophageal Doppler-derived indices such as stroke distance (StrokeD), flow time corrected (FTc), stroke distance variation (SDV), and peak velocity variation (PVV); and (2) arterial load (AL) variables during evaluation of fluid responsiveness (FR) in anesthetized dogs undergoing sudden hemodynamic shifts in blood volume. ANIMALS: 6 healthy male dogs. PROCEDURES: Dogs were anesthetized with isoflurane, ventilated mechanically, and instrumented to undergo sequential, nonrandomized experimental stages. The dogs transitioned from normovolemia (NORMO-BL) to hypovolemia (30% blood loss; HYPO-30), followed by autologous blood transfusion, and then to hypervolemia (colloid bolus). During each stage, SV was quantified using pulmonary artery thermodilution and its relationship with StrokeD, FTc, SDV, and PVV; and AL variables such as effective arterial elastance (Ea), dynamic arterial elastance (Eadyn), and total arterial compliance (Ca) were established. RESULTS: As SV decreased significantly during HYPO-30 compared to NORMO-BL, there was a significant (P < .001) decrease in StrokeD, FTc, and Ca, with simultaneous increases in SDV, PVV, Ea, and Eadyn. Upon restoration of blood volume, these values stabilized closer to NORMO-BL. A significant (P < .001) correlation was observed between SV and StrokeD, FTc, Ea, Eadyn, and Ca. CLINICAL RELEVANCE: Minimally invasive StrokeD, FTc, SDV, and PVV act as SV surrogates and help assess FR during different blood volume stages in healthy dogs. During hypovolemia-induced hypotension, Ea, Eadyn, and Ca may be able to guide therapeutic decisions favoring improvement in blood pressure and SV.


Asunto(s)
Enfermedades de los Perros , Hipovolemia , Masculino , Perros , Animales , Hipovolemia/veterinaria , Fluidoterapia/veterinaria , Hemodinámica , Volumen Sanguíneo , Presión Sanguínea/fisiología , Volumen Sistólico/fisiología , Arteria Pulmonar
10.
Plant Dis ; 107(4): 1012-1021, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36410014

RESUMEN

Frogeye leaf spot (FLS) is a foliar disease of soybean (Glycine max) caused by Cercospora sojina. Application of fungicide products that contain quinone outside inhibitor (QoI) active ingredients has been one of the major tools used in the management of this disease, but, since 2010, QoI-resistant C. sojina isolates have been confirmed in over 20 states in the United States, including Indiana. In summer 2019 and 2020, 406 isolates of C. sojina were collected from 32 counties across Indiana and screened for QoI resistance using a PCR-restriction fragment length polymorphism (RFLP) method. An in vitro fungicide sensitivity test was also performed on a subset of isolates to evaluate their sensitivity to three QoI fungicides: azoxystrobin, pyraclostrobin, and picoxystrobin. A discriminatory dose of picoxystrobin was established as 1 µg/ml by testing five concentrations (0.001, 0.01, 0.1, 1, and 10 µg/ml). QoI-resistant isolates were found in 29 counties, and 251 of the 406 isolates (61.8%) were confirmed to be resistant to QoI fungicides based on PCR-RFLP results. Partial nucleotide sequences of the cytochrome b gene from four resistant and four sensitive isolates corroborated the presence and absence, respectively, of the G143A mutation. Results from the sensitivity assays with discriminatory doses of azoxystrobin (1 µg/ml) and pyraclostrobin (0.1 µg/ml) also supported the findings from the PCR-RFLP assay, because all QoI-resistant isolates were inhibited less than 50% relative to a no-fungicide control when exposed to these doses. Resistant isolates harboring the G143A mutation also exhibited resistance to picoxystrobin. The effective concentrations to inhibit mycelial growth by 50% relative to the nonamended control (EC50) in QoI-sensitive isolates ranged from 0.087 to 0.243 µg/ml, with an overall mean of 0.152 µg/ml, while EC50 values in QoI-resistant isolates were established as >10 µg/ml for picoxystrobin. Results from this study indicated that QoI-resistant C. sojina isolates are spread throughout Indiana and exhibit cross-resistance to QoI fungicides.


Asunto(s)
Fungicidas Industriales , Glycine max , Estados Unidos , Indiana , Farmacorresistencia Fúngica/genética , Fungicidas Industriales/farmacología , Quinonas
11.
Vet Anaesth Analg ; 49(1): 26-35, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34654643

RESUMEN

OBJECTIVE: To determine the effect of fentanyl on the minimum alveolar concentration of isoflurane (MACISO) and cardiovascular variables in dogs, and how the treatment of bradycardia affects them. STUDY DESIGN: Prospective, randomized crossover-controlled trial. ANIMALS: A total of six male Beagle dogs weighing 9.9 ± 0.7 kg (mean ± standard deviation) and aged 13 months. METHODS: To each dog, two treatments were assigned on different days: fentanyl (FENTA) or fentanyl plus glycopyrrolate (FENTAglyco) to maintain heart rate (HR) between 100 and 132 beats minute-1. Determinations of MACISO were performed with 10 plasma fentanyl target concentrations ([Fenta]Target (0, 0.16, 0.32, 0.64, 1.25, 2.5, 5.0, 10.0, 20.0 and 40.0 ng mL-1) for FENTA and 5 [Fenta]Target (0, 1.25, 2.5, 5.0, 10.0 ng mL-1)) for FENTAglyco. During each MACISO determination, cardiovascular variables [mean arterial pressure (MAP), HR and cardiac index (CI)] were measured, and systemic vascular resistance index (SVRI) calculated. Pharmacodynamic models were used to describe the plasma fentanyl concentration [Fenta]-response relationship for the effect on MACISO and cardiovascular variables. A mixed-model analysis of variance followed by Dunnett's or Tukey's test, and the Bonferroni adjustment were used for comparisons within and between each treatment, respectively. Significance was set as p < 0.05. RESULTS: Fentanyl decreased MACISO by a maximum of 84%. The [Fenta] producing 50% decrease in MAC, HR and CI were 2.64, 3.65 and 4.30 ng mL-1 (typical values of population model), respectively. The prevention of fentanyl-mediated bradycardia caused no significant effect on MACISO, but increased HR, MAP and CI, and decreased SVRI when compared with isoflurane alone. CONCLUSIONS AND CLINICAL RELEVANCE: Fentanyl caused a plasma concentration-dependent decrease in MACISO, HR and CI and an increase in SVRI. Cardiovascular improvements associated with fentanyl in isoflurane-anesthetized dogs only occurred when the fentanyl-mediated bradycardia was prevented.


Asunto(s)
Anestésicos por Inhalación , Enfermedades de los Perros , Isoflurano , Anestésicos por Inhalación/farmacología , Animales , Bradicardia/inducido químicamente , Bradicardia/veterinaria , Perros , Fentanilo/farmacología , Frecuencia Cardíaca , Isoflurano/farmacología , Masculino , Estudios Prospectivos , Alveolos Pulmonares
12.
Sci Rep ; 11(1): 22952, 2021 11 25.
Artículo en Inglés | MEDLINE | ID: mdl-34824383

RESUMEN

To determine the role of early acquisition of blood oxygen level-dependent (BOLD) signals and diffusion tensor imaging (DTI) for analysis of the connectivity of the ascending arousal network (AAN) in predicting neurological outcomes after acute traumatic brain injury (TBI), cardiopulmonary arrest (CPA), or stroke. A prospective analysis of 50 comatose patients was performed during their ICU stay. Image processing was conducted to assess structural and functional connectivity of the AAN. Outcomes were evaluated after 3 and 6 months. Nineteen patients (38%) had stroke, 18 (36%) CPA, and 13 (26%) TBI. Twenty-three patients were comatose (44%), 11 were in a minimally conscious state (20%), and 16 had unresponsive wakefulness syndrome (32%). Univariate analysis demonstrated that measurements of diffusivity, functional connectivity, and numbers of fibers in the gray matter, white matter, whole brain, midbrain reticular formation, and pontis oralis nucleus may serve as predictive biomarkers of outcome depending on the diagnosis. Multivariate analysis demonstrated a correlation of the predicted value and the real outcome for each separate diagnosis and for all the etiologies together. Findings suggest that the above imaging biomarkers may have a predictive role for the outcome of comatose patients after acute TBI, CPA, or stroke.


Asunto(s)
Trastornos de la Conciencia , Vías Nerviosas , Adulto , Anciano , Nivel de Alerta , Biomarcadores , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Lesiones Encefálicas/fisiopatología , Lesiones Traumáticas del Encéfalo/complicaciones , Lesiones Traumáticas del Encéfalo/diagnóstico , Coma/diagnóstico por imagen , Coma/etiología , Coma/fisiopatología , Estado de Conciencia/fisiología , Trastornos de la Conciencia/diagnóstico por imagen , Trastornos de la Conciencia/etiología , Trastornos de la Conciencia/fisiopatología , Imagen de Difusión Tensora , Femenino , Paro Cardíaco/complicaciones , Paro Cardíaco/diagnóstico , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Vías Nerviosas/diagnóstico por imagen , Vías Nerviosas/fisiopatología , Saturación de Oxígeno , Pronóstico , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico
13.
Vet Anaesth Analg ; 48(4): 509-516, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34059460

RESUMEN

OBJECTIVE: To describe the pharmacokinetics of buprenorphine in dogs following administration of a high-concentration formulation of buprenorphine. STUDY DESIGN: Prospective, randomized, crossover study. ANIMALS: A total of six healthy male intact Beagle dogs, aged 9-13 months and weighing 10.3 ± 1.4 kg (mean ± standard deviation). METHODS: Dogs were randomized to be administered buprenorphine (0.12 mg kg-1; Simbadol, 1.8 mg mL-1) via the intravenous (lateral saphenous) or subcutaneous (dorsal interscapular) route followed by the alternative route of administration after a 14 day interval. Blood was sampled before administration and at set times up to 72 hours after injection. Plasma buprenorphine concentration was measured using liquid chromatography-tandem mass spectrometry. RESULTS: A three-compartment model with zero or biphasic rapid and slow first-order input in (intravenous or subcutaneous data, respectively) and first-order elimination from the central compartment best fitted the data. The rapid first-order input accounted for 63% of the dosage absorption. Typical values (% interindividual variability) for the three compartment volumes were 900 (33), 2425 (not estimated) and 6360 (28) mL kg-1. The metabolic and two distribution clearances were 25.7 (21), 107.5 (74) and 5.7 (61) mL minute-1 kg-1. The absorption half-life for the fast absorption phase was 8.9 minutes with a 0.7 (103) minute delay. The absorption half-life for the slow absorption phase was 347 minutes with a 226 (42) minute delay. Median (range) bioavailability calculated from noncompartmental analysis was 143 (80-239)%. Calculated terminal half-life was 963 minutes. CONCLUSIONS AND CLINICAL RELEVANCE: The high-concentration formulation of buprenorphine administered subcutaneously had a large volume of distribution and a rapid absorption phase followed by slower, delayed absorption. The high estimate of bioavailability should be interpreted with caution as values above 100% are most commonly related to experimental issues.


Asunto(s)
Buprenorfina , Perros , Administración Intravenosa/veterinaria , Analgésicos Opioides , Animales , Disponibilidad Biológica , Buprenorfina/farmacocinética , Estudios Cruzados , Perros/sangre , Semivida , Masculino , Estudios Prospectivos
14.
Vet Anaesth Analg ; 48(3): 324-333, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33741264

RESUMEN

OBJECTIVES: To compare pulmonary gas exchange, tissue oxygenation and cardiovascular effects of four levels of end-expiratory pressure: no positive end-expiratory pressure (ZEEP), positive end-expiratory pressure (PEEP) of maximal respiratory system compliance (PEEPmaxCrs), PEEPmaxCrs + 2 cmH2O (PEEPmaxCrs+2), PEEPmaxCrs + 4 cmH2O (PEEPmaxCrs+4), in isoflurane-anesthetized dogs. STUDY DESIGN: Prospective randomized crossover study. ANIMALS: A total of seven healthy male Beagle dogs, aged 1 year and weighing 10.2 ± 0.7 kg (mean ± standard deviation). METHODS: The dogs were administered acepromazine and anesthesia was induced with propofol and maintained with isoflurane. Ventilation was controlled for 4 hours with ZEEP, PEEPmaxCrs, PEEPmaxCrs+2 or PEEPmaxCrs+4. Cardiovascular, pulmonary gas exchange and tissue oxygenation data were evaluated at 5, 60, 120, 180 and 240 minutes of ventilation and compared using a mixed-model anova followed by Bonferroni test. p < 0.05 was considered significant. RESULTS: Cardiac index (CI) and mean arterial pressure (MAP) were lower in all PEEP treatments at 5 minutes when compared with ZEEP. CI persisted lower throughout the 4 hours only in PEEPmaxCrs+4 with the lowest CI at 5 minutes (2.15 ± 0.70 versus 3.45 ± 0.94 L minute-1 m-2). At 180 and 240 minutes, MAP was lower in PEEPmaxCrs+4 than in PEEPmaxCrs, with the lowest value at 180 minutes (58 ± 7 versus 67 ± 7 mmHg). Oxygen delivery index (DO2I) was lower in PEEPmaxCrs+4 than in ZEEP at 5, 60, 120 and 180 minutes. Venous admixture was not different among treatments. CONCLUSION AND CLINICAL RELEVANCE: The use of PEEP caused a transient decrease in MAP and CI in lung-healthy dogs anesthetized with isoflurane, which improved after 60 minutes of ventilation in all levels of PEEP except PEEPmaxCrs+4. A clinically significant improvement in arterial oxygenation and DO2I was not observed with PEEPmaxCrs and PEEPmaxCrs+2 in comparison with ZEEP, whereas PEEPmaxCrs+4 decreased DO2I.


Asunto(s)
Perros , Isoflurano , Animales , Estudios Cruzados , Perros/fisiología , Masculino , Respiración con Presión Positiva/veterinaria , Estudios Prospectivos , Intercambio Gaseoso Pulmonar , Respiración Artificial/veterinaria
16.
BMC Vet Res ; 16(1): 388, 2020 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-33050932

RESUMEN

BACKGROUND: This is the first case report description, to our knowledge, of a cranial mediastinal mass (suspected thymoma) causing orthostatic hypotension in a dog. CASE PRESENTATION: A Labrador Retriever presented for urethral stent placement during cystoscopy secondary to transitional cell carcinoma diagnosis. During anesthesia, the patient had unexpected severe and poorly-responsive hypotension following a shift in position. Several days later, an intrathoracic mass was discovered, raising concerns that the position of the mass in relation to the great vessels and heart may have been the cause of the hypotension. The patient returned for a second stent placement, and computed tomography of the chest confirmed a cranial mediastinal mass, most suspected to be thymoma based on the results of cytology. The patient was kept in sternal recumbency, but when re-positioning to left lateral recumbency, there was a dramatic blood pressure drop that corrected with a return to sternal positioning. CONCLUSIONS: To our knowledge, orthostatic hypotension has not been described in relation to thymoma in dogs. Thymomas are rare; however, they may be associated with disease of autonomic dysfunction, such as myasthenia gravis, that may lead to orthostatic hypotension. This has been described within the human literature, and we hypothesize it was present in the currently described case. Concurrently, thymomas may grow to a substantial size and cause direct compression of the intrathoracic vasculature. As such, it should be on the differential list for poorly-responsive hypotension following a shift in body positioning under anesthesia.


Asunto(s)
Enfermedades de los Perros/etiología , Hipotensión Ortostática/veterinaria , Timoma/veterinaria , Neoplasias del Timo/veterinaria , Animales , Enfermedades de los Perros/diagnóstico por imagen , Perros , Hipotensión Ortostática/diagnóstico , Hipotensión Ortostática/etiología , Masculino , Timoma/complicaciones , Timoma/diagnóstico por imagen , Neoplasias del Timo/complicaciones , Neoplasias del Timo/diagnóstico por imagen
17.
Nature ; 585(7825): 363-367, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32939071

RESUMEN

Astronomers have discovered thousands of planets outside the Solar System1, most of which orbit stars that will eventually evolve into red giants and then into white dwarfs. During the red giant phase, any close-orbiting planets will be engulfed by the star2, but more distant planets can survive this phase and remain in orbit around the white dwarf3,4. Some white dwarfs show evidence for rocky material floating in their atmospheres5, in warm debris disks6-9 or orbiting very closely10-12, which has been interpreted as the debris of rocky planets that were scattered inwards and tidally disrupted13. Recently, the discovery of a gaseous debris disk with a composition similar to that of ice giant planets14 demonstrated that massive planets might also find their way into tight orbits around white dwarfs, but it is unclear whether these planets can survive the journey. So far, no intact planets have been detected in close orbits around white dwarfs. Here we report the observation of a giant planet candidate transiting the white dwarf WD 1856+534 (TIC 267574918) every 1.4 days. We observed and modelled the periodic dimming of the white dwarf caused by the planet candidate passing in front of the star in its orbit. The planet candidate is roughly the same size as Jupiter and is no more than 14 times as massive (with 95 per cent confidence). Other cases of white dwarfs with close brown dwarf or stellar companions are explained as the consequence of common-envelope evolution, wherein the original orbit is enveloped during the red giant phase and shrinks owing to friction. In this case, however, the long orbital period (compared with other white dwarfs with close brown dwarf or stellar companions) and low mass of the planet candidate make common-envelope evolution less likely. Instead, our findings for the WD 1856+534 system indicate that giant planets can be scattered into tight orbits without being tidally disrupted, motivating the search for smaller transiting planets around white dwarfs.

18.
Health Econ ; 29(2): 111-122, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31828867

RESUMEN

Conditional cash transfer programs have become instrumental in encouraging the use of formal health services in developing countries, but little is known about their effect on the use of low-quality informal care. Using a large survey of Peruvian rural households and a regression discontinuity design, we find a sizeable reduction in the use of informal health care providers not only by targeted but also by nontargeted members of households that qualify for the program. This indicates the existence of spillover effects within the household. We also provide evidence that beyond the direct increase in income, the availability of better information about institutional services is a potential mechanism that drives these effects.


Asunto(s)
Atención a la Salud/economía , Autoevaluación Diagnóstica , Apoyo Financiero , Atención al Paciente , Adulto , Niño , Femenino , Humanos , Masculino , Atención al Paciente/economía , Atención al Paciente/estadística & datos numéricos , Perú , Sistema de Registros , Población Rural
19.
Vet Anaesth Analg ; 46(6): 736-744, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31353195

RESUMEN

OBJECTIVE: To compare the pharmacokinetics of fentanyl at lower (LHR) or higher heart rate (HHR) in dogs anesthetized with isoflurane. STUDY DESIGN: Prospective, randomized, crossover controlled trial. ANIMALS: A group of six healthy 13-month-old male Beagle dogs weighing 9.9 ± 0.7 kg (mean ± standard deviation). METHODS: Dogs were allocated to two treatments: LHR (HR: 45-75 beats minute-1) and HHR (HR: 100-130 beats minute-1). Anesthesia was maintained with isoflurane and hydromorphone (0.1 mg kg-1 followed by 0.02-0.10 mg kg-1 hour-1) for both treatments. Glycopyrrolate was administered in HHR to maintain HR within the desired range. Afterwards, fentanyl (20 µg kg-1) was intravenously administered over 5 minutes. Arterial blood samples were collected for plasma fentanyl concentration measurement by liquid chromatography/mass spectrometry. The pharmacokinetics of fentanyl were compared between treatments and the differences were considered significant at p < 0.05. RESULTS: A three-compartment model best fitted the changes in plasma fentanyl concentration. Clearance (CL; mL minute-1 kg-1) was 33.2 (24.0-48.0) and 61.3 (44.5-72.7), maximum concentration (ng mL-1) 33.6 (23.4-36.6) and 20.0 (16.7-28.0), apparent volume of the rapid peripheral compartment (mL kg-1) 436 (352-723) and 925 (499-1887), apparent volume at steady state (mL kg-1) 4064 (3453-6546) and 7195 (5077-8601), cardiac index (CI; mL minute-1 m-2) 2.83 (1.98-3.67) and 4.91 (3.22-6.09) and HR (beats minute-1) 68 (49-72) and 120 (102-129) for LHR and HHR, respectively, with significant differences between treatments. Significant correlations (0.92 and 0.90) were found between CI and CL, and between HR and CL, respectively. CONCLUSIONS AND CLINICAL RELEVANCE: The increase in HR and the resultant improvement in cardiac output increased fentanyl CL and volume of distribution, which resulted in a decrease in plasma fentanyl concentration in isoflurane-anesthetized dogs.


Asunto(s)
Fentanilo/farmacocinética , Frecuencia Cardíaca/fisiología , Hidromorfona/farmacocinética , Isoflurano/farmacocinética , Adyuvantes Anestésicos/administración & dosificación , Adyuvantes Anestésicos/farmacocinética , Analgésicos Opioides/administración & dosificación , Analgésicos Opioides/farmacocinética , Anestésicos por Inhalación/administración & dosificación , Anestésicos por Inhalación/farmacocinética , Animales , Estudios Cruzados , Perros , Interacciones Farmacológicas , Fentanilo/administración & dosificación , Frecuencia Cardíaca/efectos de los fármacos , Hidromorfona/administración & dosificación , Isoflurano/administración & dosificación , Masculino
20.
Vet Anaesth Analg ; 46(3): 360-364, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30772260

RESUMEN

OBJECTIVE: To evaluate the effect of two doses of fentanyl upon chest wall rigidity of dogs anesthetized at equipotent doses of isoflurane [1.3 minimum alveolar concentration (MACISO) of each dose of fentanyl]. STUDY DESIGN: Prospective crossover randomized study. ANIMALS: A group of eight male Beagle dogs, approximately 1 year old and weighing 12.1 ± 1.6 kg (mean ± standard deviation). METHODS: The dogs were anesthetized with isoflurane and instrumented for the measurement of esophageal pressure (PESO), flow (V˙) and volume (V). Chest wall elastance (ECW) was estimated by multiple linear regression of the model. PESO(t) = V˙(t) × RCW + V(t) × ECW + EEPESO where t is time, RCW is chest wall resistance and EEPESO is end-expiratory PESO. Chest wall compliance (CCW) was calculated as 1/ECW and normalized to the body weight of each dog (mL cmH2O-1 kg-1). Anesthesia was maintained at 1.3 MACISO for at least 15 minutes and CCW recorded (CCW-ISO). The dogs were randomly assigned to the lower fentanyl dose [loading dose (33 µg kg-1) and infusion (0.2 µg kg-1 minute-1)] or the higher fentanyl dose [loading dose (102 µg kg-1) and infusion (0.8 µg kg-1 minute-1)]. After 60 minutes of fentanyl infusion, CCW was recorded for each dose (CCW-FENT). During fentanyl infusion, the dogs were maintained at equipotent doses of isoflurane (1.3 MACISO for each fentanyl dose). A two-way analysis of variance followed by a Bonferroni test was used to compare CCW-ISO and CCW-FENT in both treatments and CCW-FENT between treatments. A p value <0.05 was considered significant. RESULTS: Neither of the fentanyl doses decreased CCW and there was no difference in CCW-FENT between doses. CONCLUSIONS AND CLINICAL RELEVANCE: Fentanyl at the studied doses did not result in chest wall rigidity in dogs anesthetized with equipotent doses of isoflurane (1.3 MACISO).


Asunto(s)
Adyuvantes Anestésicos/farmacología , Analgésicos Opioides/farmacología , Anestesia/veterinaria , Perros , Fentanilo/farmacología , Isoflurano/farmacología , Pared Torácica/efectos de los fármacos , Anestésicos por Inhalación/farmacología , Animales , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Fentanilo/administración & dosificación , Isoflurano/administración & dosificación , Masculino , Estudios Prospectivos , Ventilación Pulmonar/efectos de los fármacos , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...