Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27766931

RESUMEN

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Asunto(s)
Bioensayo/métodos , Aberraciones Cromosómicas/efectos de la radiación , Pruebas de Micronúcleos/métodos , Garantía de la Calidad de Atención de Salud , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Bioensayo/normas , Europa (Continente) , Humanos , Linfocitos/efectos de la radiación , Monitoreo de Radiación/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
Radiat Prot Dosimetry ; 171(1): 64-9, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27555654

RESUMEN

Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included.


Asunto(s)
Protección Radiológica/métodos , Liberación de Radiactividad Peligrosa/prevención & control , Radiometría/métodos , Planificación en Desastres/métodos , Humanos , Agencias Internacionales , Cooperación Internacional , América Latina
3.
Radiat Prot Dosimetry ; 154(1): 18-25, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22869818

RESUMEN

The bottleneck in data acquisition during biological dosimetry based on a dicentric assay is the need to score dicentrics in a large number of lymphocytes. One way to increase the capacity of a given laboratory is to use the ability of skilled operators from other laboratories. This can be done using image analysis systems and distributing images all around the world. Two exercises were conducted to test the efficiency of such an approach involving 10 laboratories. During the first exercise (E1), the participant laboratories analysed the same images derived from cells exposed to 0.5 and 3 Gy; 100 images were sent to all participants for both doses. Whatever the dose, only about half of the cells were complete with well-spread metaphases suitable for analysis. A coefficient of variation (CV) on the standard deviation of ∼15 % was obtained for both doses. The trueness was better for 3 Gy (0.6 %) than for 0.5 Gy (37.8 %). The number of estimated doses classified as satisfactory according to the z-score was 3 at 0.5 Gy and 8 at 3 Gy for 10 dose estimations. In the second exercise, an emergency situation was tested, each laboratory was required to score a different set of 50 images in 2 d extracted from 500 downloaded images derived from cells exposed to 0.5 Gy. Then the remaining 450 images had to be scored within a week. Using 50 different images, the CV on the estimated doses (79.2 %) was not as good as in E1, probably associated to a lower number of cells analysed (50 vs. 100) or from the fact that laboratories analysed a different set of images. The trueness for the dose was better after scoring 500 cells (22.5 %) than after 50 cells (26.8 %). For the 10 dose estimations, the number of doses classified as satisfactory according to the z-score was 9, for both 50 and 500 cells. Overall, the results obtained support the feasibility of networking using electronically transmitted images. However, before its implementation some issues should be elucidated, such as the number and resolution of the images to be sent, and the harmonisation of the scoring criteria. Additionally, a global website able to be used for the different regional networks, like Share Points, will be desirable to facilitate worldwide communication.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Cromosomas Humanos/efectos de la radiación , Rayos gamma/efectos adversos , Laboratorios/normas , Linfocitos/efectos de la radiación , Bioensayo , Relación Dosis-Respuesta en la Radiación , Humanos , Radiometría
4.
Radiat Prot Dosimetry ; 106(2): 131-5, 2003.
Artículo en Inglés | MEDLINE | ID: mdl-14653333

RESUMEN

The variations of dose response with X ray energy observed with the human lymphocyte dicentric assay is examined. In order to determine reliably the initial slopes (RBEm) many cells need to be analysed at low doses. Insufficient analysis may explain some reported interlaboratory differences in fitted dose-response coefficients. One such discrepancy at 150 kVp, E = 70 keV is examined. Data are also presented for an X ray spectrum of 80 kVp, E = 58 keV. Over the photon energy range 20 keV X rays to 1.25 MeV gamma rays RBEm varies by about a factor of 5, with the lower energies being more effective. This is consistent with microdosimetric theory. By contrast, in radiological protection a radiation weighting factor of 1.0 is assumed for all photons when assessing the risk of inducing cancer at low doses. The measured variations of biological effect with photon energy have led to suggestions that the lower energies, as used for some diagnostic radiology, carry a greater risk per unit dose than is normally assumed by those involved in radiological protection. Interpretation of the data reported in this paper does not support this view.


Asunto(s)
Aberraciones Cromosómicas/efectos de la radiación , Cromosomas/efectos de la radiación , Leucocitos Mononucleares/patología , Leucocitos Mononucleares/efectos de la radiación , Células Cultivadas , Relación Dosis-Respuesta en la Radiación , Femenino , Alemania , Humanos , Masculino , Dosis de Radiación , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Reino Unido , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA