1.
J Chromatogr A ; 1722: 464862, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38581978

RESUMEN

The 21st century has been particularly productive for the biopharmaceutical industry, with the introduction of several classes of innovative therapeutics, such as monoclonal antibodies and related compounds, gene therapy products, and RNA-based modalities. All these new molecules are susceptible to aggregation and fragmentation, which necessitates a size variant analysis for their comprehensive characterization. Size exclusion chromatography (SEC) is one of the reference techniques that can be applied. The analytical techniques for mAbs are now well established and some of them are now emerging for the newer modalities. In this context, the objective of this review article is: i) to provide a short historical background on SEC, ii) to suggest some clear guidelines on the selection of packing material and mobile phase for successful method development in modern SEC; and iii) to highlight recent advances in SEC, such as the use of narrow-bore and micro-bore columns, ultra-wide pore columns, and low-adsorption column hardware. Some important innovations, such as recycling SEC, the coupling of SEC with mass spectrometry, and the use of alternative detectors such as charge detection mass spectrometry and mass photometry are also described. In addition, this review discusses the use of SEC in multidimensional setups and shows some of the most recent advances at the preparative scale. In the third part of the article, the possibility of SEC for the characterization of new modalities is also reviewed. The final objective of this review is to provide a clear summary of opportunities and limitations of SEC for the analysis of different biopharmaceutical products.


Asunto(s)
Cromatografía en Gel , Liposomas , Nanopartículas , Cromatografía en Gel/métodos , Nanopartículas/química , Productos Biológicos/análisis , Productos Biológicos/química , Ácidos Nucleicos/análisis , Vectores Genéticos , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/análisis , Anticuerpos Monoclonales/aislamiento & purificación , Proteínas/análisis , Proteínas/química , Humanos , Lípidos/química , Lípidos/análisis , Espectrometría de Masas/métodos
2.
J Sep Sci ; 47(5): e2300928, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38471977

RESUMEN

This review provides an overview of the latest advancements and applications in multi-dimensional liquid chromatography coupled with mass spectrometry (mD-LC-MS), covering aspects such as inter-laboratory studies, digestion strategy, trapping column, and multi-level analysis. The shift from an offline to an online workflow reduces sample processing artifacts, analytical variability, analysis time, and the labor required for data acquisition. Over the past few years, this technique has demonstrated sufficient maturity for application across a diverse range of complex products. Moreover, there is potential for this strategy to evolve into an integrated process analytical technology tool for the real-time monitoring of monoclonal antibody quality. This review also identifies emerging trends, including its application to new modalities, the possibility of evaluating biological activity within the mD-LC set-up, and the consideration of multi-dimensional capillary electrophoresis as an alternative to mD-LC. As mD-LC-MS continues to evolve and integrate emerging trends, it holds the potential to shape the next generation of analytical tools, offering exciting possibilities for enhanced characterization and monitoring of complex biopharmaceutical products.


Asunto(s)
Anticuerpos Monoclonales , Productos Biológicos , Cromatografía Liquida/métodos , Espectrometría de Masas/métodos , Anticuerpos Monoclonales/química , Tecnología
3.
J Chromatogr A ; 1718: 464725, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38364617

RESUMEN

Online comprehensive two-dimensional liquid chromatography (online LC x LC) has become increasingly popular. Among the different chromatographic modes that can be combined, hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) are particularly interesting because they offer a high degree of orthogonality. However, this combination remains complex due to the incompatibility of the solvents in the two dimensions. To avoid this problem, it is possible to dilute the first dimension (1D) effluent with (zdilution -1) volumes of a weaker solvent added to one volume of 1D-effluent, where zdilution represents the extent to which the fraction volume has been multiplied. This can be done using either active solvent modulation technology or an additional pump, prior to the second dimension analysis. The objective of this study was to develop theoretical models to predict whether or not dilution can be effective, and, if so, what is the minimum zdilution value required. This approach is based on the calculation of the ratio (called xdilution) between the peak standard deviation due to the injection process and the peak standard deviation in the absence of extra-column dispersion. xdilution was calculated from theoretical relationships and plotted as a function of zdilution, to predict the value required to obtain good peak shapes for the compound of interest. The maximum xdilution value was found to be of the order of 1 for chromatographically acceptable peak shapes. The proposed theoretical approach was experimentally validated on a number of representative small molecules and peptides. Agreement between experimental results and theoretical models was very high, especially for small molecules. Finally, it is shown that this approach helps to predict the most appropriate set of conditions in HILIC x RPLC, depending on the compounds to be separated.


Asunto(s)
Cromatografía de Fase Inversa , Péptidos , Solventes/química , Cromatografía de Fase Inversa/métodos , Modelos Teóricos , Interacciones Hidrofóbicas e Hidrofílicas
4.
J Chromatogr A ; 1713: 464498, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-37980809

RESUMEN

When therapeutic proteins are analysed under hydrophilic interaction liquid chromatography (HILIC) conditions, there is an inherent mismatch between the sample diluent (proteins must be solubilised in aqueous media) and the mobile phase, which is mostly composed of aprotic solvent (acetonitrile). This difference in eluent strength between sample diluent and mobile phase is responsible for severe analyte breakthrough and peak distortion. As demonstrated with therapeutic proteins of different sizes (insulin of 6 kDa, anakinra of 17 kDa and rituximab subunits of 25 and 50 kDa), only very small volumes of 0.1-0.2 µL can be injected without breakthrough effects, when performing rapid analysis on short HILIC columns of 20-50 mm, leading to poor sensitivity. In order to avoid the undesired effect of the strong sample diluent, a special injection program should be preferred. This consists in the addition and automatic injection of a defined volume of weak solvent (acetonitrile) along with the sample to increase retention factors during sample loading. Various injection programs were tested, including the addition of a pre-injection or post-injection or both (bracketed injection) of acetonitrile plugs. Several weak to strong injection solvent ratios of 1:1, 1:2, 1:4 and 1:10 were tested. Our work proves that the addition of a pre-plug solvent with a weak vs. strong injection solvent ratio of 1:10 is a valuable strategy to inject relatively large volumes of proteins in HILIC, regardless of column dimensions, thus maximising sensitivity. No peak deformation or breakthrough was observed under these conditions. However, it is important to note that peak broadening (40 % larger peaks) was observed when the injection program increased the injection solvent ratio from 1:1 to 1:10. Finally, this strategy was applied to a wide range of therapeutic mAb products with different physico-chemical properties. In all cases, relatively large volumes can be successfully injected onto small volume HILIC columns using a purely aqueous sample diluent, as long as an appropriate (weak) solvent pre-injection is applied.


Asunto(s)
Agua , Cromatografía Liquida , Solventes/química , Agua/química , Interacciones Hidrofóbicas e Hidrofílicas , Acetonitrilos/química , Indicadores y Reactivos
5.
Int J Mol Sci ; 24(23)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38068945

RESUMEN

Charge heterogeneity among therapeutic monoclonal antibodies (mAbs) is considered an important critical quality attribute and requires careful characterization to ensure safe and efficacious drug products. The charge heterogeneity among mAbs is the result of chemical and enzymatic post-translational modifications and leads to the formation of acidic and basic variants that can be characterized using cation exchange chromatography (CEX). Recently, the use of mass spectrometry-compatible salt-mediated pH gradients has gained increased attention to elute the proteins from the charged stationary phase material. However, with the increasing antibody product complexity, more and more selectivity is required. Therefore, in this study, we set out to improve the selectivity by using a solvent-enriched mobile phase composition for the analysis of a variety of mAbs and bispecific antibody products. It was found that the addition of the solvents to the mobile phase appeared to modify the hydrate shell surrounding the protein and alter the retention behavior of the studied proteins. Therefore, this work demonstrates that the use of solvent-enriched mobile phase composition could be an attractive additional method parameter during method development in CEX.


Asunto(s)
Productos Biológicos , Concentración de Iones de Hidrógeno , Anticuerpos Monoclonales/química , Solventes , Indicadores y Reactivos , Cromatografía por Intercambio Iónico/métodos
7.
J Chromatogr A ; 1709: 464359, 2023 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-37717303

RESUMEN

The impact of injected sample volume on apparent efficiency has been studied for very short columns in a systematic way. For large molecules such as therapeutic proteins, it was found that relatively large volumes can be injected onto ultra-short RPLC and IEX columns (i.e. L < 50 mm) without significantly affecting the quality of the separation. This favourable behavior is due to the on-off elution mechanism of large molecules and to the fact that therapeutic protein samples are formulated in aqueous-based media, which is the weakest solvent in RPLC and IEX. Therefore, their peak is strongly focused at the column inlet even when large volume is injected, and pre-column peak dispersion is compensated. However, ultra-short HILIC columns do not seem to be favorable, as they require for very low injection volume to avoid detrimental peak splitting and breakthrough effects. Such peak distortion is related to the inherent solvent mismatch between sample diluent (aqueous) and mobile phase strength (highly organic in HILIC). When studying mass load, the ranking of the elution modes was the same, and the largest relative mass could be injected onto IEX columns (as large as 10% sample to sorbent mass), without affecting the separation quality.

8.
J Chromatogr A ; 1706: 464285, 2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37562104

RESUMEN

Today, reverse phase liquid chromatography (RPLC) analysis of proteins is almost exclusively performed on conventional columns (100-150 mm) in gradient elution mode. However, it was shown many years ago that large molecules present an on/off retention mechanism, and that only a very short inlet segment of the chromatographic column retains effectively the large molecules. Much shorter columns - like only a few centimetres or even a few millimetres - can therefore be used to efficiently analyse such macromolecules. The aim of this review is to summarise the historical and more recent works related to the use of very short columns for the analysis of model and therapeutic proteins. To this end, we have outlined the theoretical concepts behind the use of short columns, as well as the instrumental limitations and potential applications. Finally, we have shown that these very short columns were also possibly interesting for other chromatographic modes, such as ion exchange chromatography (IEX), hydrophilic interaction chromatography (HILIC) or hydrophobic interaction chromatography (HIC), as analyses in these chromatographic modes are performed in gradient elution mode.


Asunto(s)
Cromatografía de Fase Inversa , Proteínas , Cromatografía Líquida de Alta Presión , Cromatografía por Intercambio Iónico/métodos , Proteínas/química , Interacciones Hidrofóbicas e Hidrofílicas
9.
J Pharm Biomed Anal ; 234: 115544, 2023 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-37418870

RESUMEN

Monoclonal antibody (mAb)-based therapies have been a major advance in oncology patient care, even though they represent a significant healthcare cost. Biosimilars, launched in Europe in 2004 are an economically attractive alternative to expensive originator biological drugs. They also increase the competitiveness of pharmaceutical development. This article focuses on the case of Erbitux® (cetuximab). This anti-EGFR (Epidermal Growth Factor Receptor) monoclonal antibody is indicated for metastatic colorectal cancer (2004) and squamous cell carcinoma of the head and neck (2006). However, despite the expiration of the patent in Europe in 2014 and estimated annual sales of 1.681 million US dollars in 2022, Erbitux® has not yet faced any approved biosimilar challenges in the United States or in Europe. Here, we outline the unique structural complexity of this antibody highlighted by advanced orthogonal analytical characterization strategies resulting in risks to demonstrate biosimilarity, which may explain the lack of Erbitux® biosimilars in the European and US markets to date. The development of Erbitux® biobetters are also discussed as alternative strategies to biosimilars. These biologics offer expected additional safety and potency benefits over the reference product but require a full pharmaceutical and clinical development as for New Molecular Entities.


Asunto(s)
Biosimilares Farmacéuticos , Neoplasias , Humanos , Estados Unidos , Cetuximab/uso terapéutico , Biosimilares Farmacéuticos/uso terapéutico , Anticuerpos Monoclonales/uso terapéutico , Neoplasias/tratamiento farmacológico , Europa (Continente)
10.
Anal Chem ; 95(27): 10448-10456, 2023 07 11.
Artículo en Inglés | MEDLINE | ID: mdl-37384898

RESUMEN

Ion-pairing reversed-phase liquid chromatography (IP-RPLC) is the reference separation technique for characterizing oligonucleotides (ONs) and their related impurities. The aim of this study was to better understand the retention mechanism of ONs, evaluate the applicability of the linear solvent strength (LSS) retention model, and explore the potential of ultra-short columns having a length of only 5 mm for the separation of model ONs. First, the validity of the LSS model was evaluated for ONs having sizes comprised between 3 and 30 kDa, and the accuracy of retention time predictions was assessed. It was found that ONs in IP-RPLC conditions follow an "on-off" elution behavior, despite a molecular weight lower than that of proteins. For most linear gradient separation conditions, a column length between 5 and 35 mm was found to be appropriate. Ultra-short columns of only 5 mm were therefore explored to speed up separations by considering the impact of the instrumentation on the efficiency. Interestingly, the impacts of injection volume and post-column connection tubing on peak capacity were found to be negligible. Finally, it was demonstrated that longer columns would not improve selectivity or separation efficiency, but baseline separation of three model ONs mixtures was enabled in as little as 30 s on the 5 mm column. This proof-of-concept work paves the way for future investigations using more complex therapeutic ONs and their related impurities.


Asunto(s)
Oligonucleótidos , Proteínas , Oligonucleótidos/química , Cromatografía Líquida de Alta Presión/métodos , Cromatografía de Fase Inversa/métodos , Iones
11.
Molecules ; 28(9)2023 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-37175317

RESUMEN

The aim of the present work is to evaluate the possibilities and limitations of reversed hydrophilic interaction chromatography (revHILIC) mode in liquid chromatography (LC). This chromatographic mode consists of combining a highly polar stationary phase (bare silica) with a gradient varying from very low (1-5%) to high (40%) acetonitrile content (reversed gradient compared to HILIC). The retention behavior of revHILIC was first compared with that of reversed-phase LC (RPLC) and HILIC using representative mixtures of peptides and pharmaceutical compounds. It appears that the achievable selectivity can be ranked in the order RPLC > revHILIC > HILIC with the two different samples. Next, two-dimensional liquid chromatography (2D-LC) conditions were evaluated by combining RPLC, revHILIC, or HILIC with RPLC in an on-line comprehensive (LC × LC) mode. evHILIC × RPLC not only showed impressive performance in terms of peak capacity and sensitivity, but also provided complementary selectivity compared to RPLC × RPLC and HILIC × RPLC. Indeed, both the elution order and the retention time range differ significantly between the three techniques. In conclusion, there is no doubt that revHILIC should be considered as a viable option for 2D-LC analysis of small molecules and also peptides.


Asunto(s)
Cromatografía de Fase Inversa , Péptidos , Cromatografía Liquida/métodos , Cromatografía de Fase Inversa/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Dióxido de Silicio/química
12.
Int J Mol Sci ; 24(10)2023 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-37239849

RESUMEN

The purity of the three capsid proteins that make up recombinant adeno-associated virus (rAAV) is considered a critical quality attribute of gene therapy products. As such, there is a clear need to develop separation methods capable of rapidly characterizing these three viral proteins (VPs). In this study, the potential benefits and limitations of different electrophoretic and chromatographic methods were evaluated, including capillary electrophoresis-sodium dodecyl sulfate (CE-SDS), reversed phase liquid chromatography (RPLC), hydrophilic interaction chromatography (HILIC), and hydrophobic interaction chromatography (HIC), for the analysis of VPs obtained from different serotypes (i.e., AAV2, AAV5, AAV8, and AAV9). CE-SDS is considered to be the reference method and provides a suitable separation of VP1-3 proteins using generic conditions and laser induced fluorescence detection. However, the characterization of post-translational modifications (i.e., phosphorylation, oxidation) remains difficult, and species identification is almost impossible due to the lack of compatibility between CE-SDS and mass spectrometry (MS). In contrast, RPLC and HILIC were found to be less generic than CE-SDS and require tedious optimization of the gradient conditions for each AAV serotype. However, these two chromatographic approaches are inherently compatible with MS, and were shown to be particularly sensitive in detecting capsid protein variants resulting from different post-translational modifications. Finally, despite being non-denaturing, HIC offers disappointing performance for viral capsid proteins characterization.


Asunto(s)
Proteínas de la Cápside , Dependovirus , Proteínas de la Cápside/genética , Dependovirus/genética , Dependovirus/metabolismo , Cromatografía Liquida , Espectrometría de Masas , Proteínas Virales , Cromatografía de Fase Inversa , Dodecil Sulfato de Sodio/química , Electroforesis Capilar/métodos
13.
J Chromatogr A ; 1697: 463994, 2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37086708

RESUMEN

Monitoring the central carbon metabolism (CCM) network using liquid chromatography/mass spectrometry (LC-MS) analysis is hampered by the diverse chemical nature of its analytes, which are extremely difficult to analyze using single chromatographic conditions. Furthermore, CCM-related compounds present non-specific adsorption on metal surfaces, causing detrimental chromatographic effects and sensitivity loss. In this study, polar reversed-phase, mixed-mode (MMC), and zwitterionic hydrophilic interaction chromatography (HILIC) featuring low-adsorption hardware were investigated towards untargeted analysis of biological samples with a focus on energy metabolism-related analytes. Best results were achieved with sulfoalkylbetaine HILIC with different supports, where polymeric option featured the highest coverage and inert hybrid silica facilitated best throughput and kinetic performance at a cost of less selectivity for small carboxylic acids. MMC demonstrated excellent performance for strongly anionic analytes such as multiresidue phosphates. The obtained experimental data also suggested that an additional hydrophilic modulation might be necessary to facilitate better resolution of carboxylic acids in zHILIC mode, as found during the application of the developed method to study the effect of two different mutations on the energy metabolism of S. aureus.


Asunto(s)
Metaboloma , Staphylococcus aureus , Ácidos Carboxílicos , Cromatografía Liquida/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Espectrometría de Masas/métodos , Compuestos Orgánicos , Carbono/metabolismo
14.
Molecules ; 28(6)2023 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-36985597

RESUMEN

In the context of targeted radionuclide therapy, antibody-chelator conjugates (ACCs) are an evolving class of antibody-related drugs with promising applications as tumor-targeted pharmaceuticals. Generally, a typical ACC consists of a recombinant monoclonal antibody (mAb) coupled to radionuclide via a chelating agent. Characterizing the ACC structure represents an analytical challenge since various impurities must be constantly monitored in the presence of formulation components during the quality control (QC) process. In this contribution, a reliable method devoted to the monitoring of an ACC sample, and its small molecule-related synthesis impurities, has been developed via liquid chromatography (LC). A problem-solving approach of common analytical issues was used to highlight some major issues encountered during method development. This included separation of poorly retained impurities (issue #1); interferences from the formulation components (issue #2); analysis of impurities in presence of ACC at high concentration (issue #3); and recovery of impurities during the whole analytical procedure (issue #4). To the best of our knowledge, this is the first time that a chromatographic method for the analysis of ACC synthesis impurities is presented. In addition, the developed approach has the potential to be more widely applied to the characterization of similar ACCs and other antibody-related drugs.


Asunto(s)
Inmunoconjugados , Cromatografía Liquida , Inmunoconjugados/química , Anticuerpos Monoclonales/química , Radioisótopos , Cromatografía Líquida de Alta Presión/métodos
15.
Molecules ; 28(6)2023 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-36985827

RESUMEN

In the quest to market increasingly safer and more potent biotherapeutic proteins, the concept of the multi-attribute method (MAM) has emerged from biopharmaceutical companies to boost the quality-by-design process development. MAM strategies rely on state-of-the-art analytical workflows based on liquid chromatography coupled to mass spectrometry (LC-MS) to identify and quantify a selected series of critical quality attributes (CQA) in a single assay. Here, we aimed at evaluating the repeatability and robustness of a benchtop LC-MS platform along with bioinformatics data treatment pipelines for peptide mapping-based MAM studies using standardized LC-MS methods, with the objective to benchmark MAM methods across laboratories, taking nivolumab as a case study. Our results evidence strong interlaboratory consistency across LC-MS platforms for all CQAs (i.e., deamidation, oxidation, lysine clipping and glycosylation). In addition, our work uniquely highlights the crucial role of bioinformatics postprocessing in MAM studies, especially for low-abundant species quantification. Altogether, we believe that MAM has fostered the development of routine, robust, easy-to-use LC-MS platforms for high-throughput determination of major CQAs in a regulated environment.


Asunto(s)
Anticuerpos Monoclonales , Anticuerpos Monoclonales/química , Espectrometría de Masas/métodos , Cromatografía Liquida/métodos , Glicosilación , Mapeo Peptídico/métodos
16.
J Chromatogr A ; 1690: 463785, 2023 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-36641941

RESUMEN

Hydrophilic interaction chromatography (HILIC) has been proposed as a valuable alternative to ion-pairing reversed-phase chromatography (IP-RPLC) for oligonucleotide (ON) analysis. In this context, the potential of seven zwitterionic HILIC columns has been evaluated against amide- and poly-hydroxy fructan-functionalized HILIC columns and a C18 column operated under IP-RPLC mode. Based on the retention characteristics of key small molecule pairs, each zwitterionic HILIC column showed a unique radar-shaped profile, suggesting different selectivities for distinct structural differences. Unmodified DNA and RNA samples were then evaluated, and the columns classified based on their retentivity. Two zwitterionic columns were particularly promising in terms of overall resolution, especially for the largest ONs (> 40-mer). Finally, separations between a chemically modified drug-like ON and its closely related impurities were performed. Although the ZIC-cHILIC column showed similar selectivity values as compared to the reference IP-RPLC technique, all columns demonstrated a general decrease in selectivity due to the minor structural differences present in the highly complex samples. This work highlights the utility of zwitterionic HILIC mode for ON analysis and it reveals the importance of understanding columns characteristics - in terms of retention and selectivity - when selecting a stationary phase for specific ON applications.


Asunto(s)
Cromatografía de Fase Inversa , Oligonucleótidos , Cromatografía Liquida/métodos , Cromatografía de Fase Inversa/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Iones/química
17.
Anal Bioanal Chem ; 415(13): 2357-2369, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36323885

RESUMEN

The objective of this work was to provide an unbiased comparison of one-dimensional reversed-phase liquid chromatography (1D-RPLC) and comprehensive two-dimensional RPLC (RPLC × RPLC), through calculations and experimental verifications. For this purpose, various quality descriptors were evaluated, including peak capacity, analysis time, dilution factor, number of runs in the second dimension, and injection volume. The same strategy was applied to small pharmaceuticals and peptides. Whatever the analysis time between 30 and 200 min, short columns of only 30 × 2.1 mm packed with sub-2-µm particles should be selected in both dimensions of the 2D-LC setup to obtain the best compromise in terms of peak capacity and sensitivity. The peak capacity in RPLC × RPLC vs. RPLC was significantly improved for analysis times beyond 5 min. However, extra-column volume located after the second-dimension column was found to be particularly critical for peptides, and up to 50% lower peak capacity was observed with MS vs. UV detection. Contrary to common belief, higher dilution is not always observed in RPLC × RPLC. With adequate analytical conditions, better sensitivity (in theory fivefold and in practice three- to fivefold) could be achieved in RPLC × RPLC compared to 1D-RPLC, regardless of the analysis time.

18.
Anal Chem ; 94(49): 17131-17141, 2022 12 13.
Artículo en Inglés | MEDLINE | ID: mdl-36441925

RESUMEN

The mounting complexity of new modalities in the biopharmaceutical industry entails a commensurate level of analytical innovations to enable the rapid discovery and development of novel therapeutics and vaccines. Hydrophobic interaction chromatography (HIC) has become one of the widely preferred separation techniques for the analysis and purification of biopharmaceuticals under nondenaturing conditions. Inarguably, HIC method development remains very challenging and labor-intensive owing to the numerous factors that are typically optimized by a "hit-or-miss" strategy (e.g., the nature of the salt, stationary phase chemistry, temperature, mobile phase additive, and ionic strength). Herein, we introduce a new HIC method development framework composed of a fully automated multicolumn and multieluent platform coupled with in silico multifactorial simulation and integrated fraction collection for streamlined method screening, optimization, and analytical-scale purification of biopharmaceutical targets. The power and versatility of this workflow are showcased by a wide range of applications including trivial proteins, monoclonal antibodies (mAbs), antibody-drug conjugates (ADCs), oxidation variants, and denatured proteins. We also illustrate convenient and rapid HIC method development outcomes from the effective combination of this screening setup with computer-assisted simulations. HIC retention models were built using readily available LC simulator software outlining less than a 5% difference between experimental and simulated retention times with a correlation coefficient of >0.99 for pharmaceutically relevant multicomponent mixtures. In addition, we demonstrate how this approach paves the path for a straightforward identification of first-dimension HIC conditions that are combined with mass spectrometry (MS)-friendly reversed-phase liquid chromatography (RPLC) detection in the second dimension (heart-cutting two-dimensional (2D)-HIC-RPLC-diode array detector (DAD)-MS), enabling the analysis and purification of biopharmaceutical targets.


Asunto(s)
Productos Biológicos , Interacciones Hidrofóbicas e Hidrofílicas , Cromatografía de Fase Inversa/métodos , Espectrometría de Masas/métodos , Anticuerpos Monoclonales/análisis
19.
Pharmaceutics ; 14(11)2022 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-36365134

RESUMEN

This work illustrates the benefits and limitations of using ultra-short reversed phase liquid chromatography (RPLC) columns for the characterization of various complex bispecific antibodies after prolonged thermal stress at the middle-up level of analysis. First, we have demonstrated that alternative organic modifiers, such as isopropanol, can be used in RPLC mode without generating excessive pressure, thanks to the prototype 10 × 2.1 mm, 2.7 µm particle column. However, compared to acetonitrile, the selectivity was not improved, at least for the selected biopharmaceutical products. Importantly, very fast separations (sub-1 min) of high quality were systematically obtained for the different samples when using a spectroscopic detector, but a severe loss of performance was observed with mass spectrometry (MS) detection due to dispersion effects. Based on these results, there is a clear need to improve the interfacing between LC and MS (shorter/thinner tubing) to mitigate band broadening.

20.
Int J Mol Sci ; 23(20)2022 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-36293189

RESUMEN

Gene therapy is opening unprecedented opportunities for novel therapeutic approaches. Based on the concept of rescuing function mutations by co-expressing the correct gene to allow biological functions to be restored, it requires the use of viral vectors to ensure the proper delivery of therapeutic genes. In this context, recombinant adeno-associated viruses (rAAV) are the most widely used vectors. Their biomanufacturing process requires the insertion of the therapeutic gene into the rAAV (full capsids). However, a percentage of rAAV that do not contain the desired gene (empty capsids), as well as partly filled capsids, might also be produced, potentially impacting the efficiency of the therapy. Therefore, the determination of the rAAV capsids' full/empty ratio needs to be monitored to ensure consistent product quality and efficacy. Anion-exchange chromatography (AEX) can serve this need. In this contribution, thorough AEX method development, including a mobile phase, a stationary phase and gradient conditions, has highlighted its potential in supporting gene therapy. Taking advantage of the fact that viral capsids follow an "on/off" retention behavior, the application of a step gradient approach to the rAAV serotype 8 (rAAV8) allowed the unprecedented separation of rAAV8 full/empty capsids, with a resolution gain of 3.7 as compared to the resolution obtained with a fully optimized linear gradient. Finally, the developed analytical approach allowed a precise and accurate baseline separation and quantification of full and empty rAAV8 capsids, with the potential to be applied as a high-throughput quality control (QC) method.


Asunto(s)
Cápside , Dependovirus , Dependovirus/genética , Cápside/química , Terapia Genética , Vectores Genéticos/genética , Cromatografía , Aniones/análisis