Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Microsc Microanal ; 29(Supplement_1): 2053-2054, 2023 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-37613011
2.
AJNR Am J Neuroradiol ; 41(6): 1049-1053, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32409312

RESUMEN

BACKGROUND AND PURPOSE: About 20% of patients with acute ischemic stroke due to large-artery occlusion do not achieve recanalization with mechanical thrombectomy. We aimed to determine whether the speed of retrieval of the stent retriever influences the efficacy in removing different clot types. MATERIALS AND METHODS: Sixty mechanical thrombectomies were performed using an in vitro pulsatile cerebrovascular circulation model with controlled pressure and flow rate. Experiments were dichotomized into fast and slow retrieval using a wedging technique, in which the stent retriever and distal catheter are retrieved together. We used 3 different clot types: erythrocyte-rich, fibrin-rich, and friable clots. Primary end points were complete (TICI 3) and successful (TICI 2b-3) recanalizations. Secondary measures were distal and new territory embolizations. RESULTS: Fast retrieval was more frequently associated with complete (RR = 1.83; 95% CI, 1.12-2.99) and successful recanalization (RR = 1.50; 95% CI, 1.03-2.19) than slow retrieval, without a difference in distal embolization (RR = 0.75; 95% CI, 0.29-1.90). There were no emboli in a new territory. The advantage of fast retrieval over slow retrieval differed according to the clot composition, with a stronger effect with fibrin-rich clots with regard to complete (RR = 4.00; 95% CI, 1.11-14.35; Pint = .04) and successful (Pint = .10) recanalization. CONCLUSIONS: In our experimental model, a fast removal improved recanalization rates of mechanical thrombectomy, especially in the case of fibrin-rich clots. An in vivo confirmation is warranted to see whether our findings can have an impact in clinical practice.


Asunto(s)
Modelos Anatómicos , Trombectomía/instrumentación , Trombectomía/métodos , Anciano , Isquemia Encefálica/etiología , Isquemia Encefálica/cirugía , Femenino , Humanos , Masculino , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía , Trombosis/complicaciones , Trombosis/cirugía , Factores de Tiempo
3.
Ann Biomed Eng ; 45(11): 2494-2508, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28849421

RESUMEN

A thrombus or blood clot is a solid mass, made up of a network of fibrin, platelets and other blood components. Blood clots can form through various pathways, for example as a result of exposed tissue factor from vascular injury, as a result of low flow/stasis, or in very high shear flow conditions. Embolization of cardiac or vascular originating blood clots, causing an occlusion of the neurovasculature, is the major cause of stroke and accounts for 85% of all stroke. With mechanical thrombectomy emerging as the new standard of care in the treatment of acute ischemic stroke (AIS), the need to generate a better understanding of the biomechanical properties and material behaviour of thrombus material has never been greater, as it could have many potential benefits for the analysis and performance of these treatment devices. Defining the material properties of a thrombus has obvious implications for the development of these treatment devices. However, to-date this definition has not been adequately established. While some experimentation has been performed, model development has been extremely limited. This paper reviews the previous literature on mechanical testing of thrombus material. It also explores the use of various constitutive and computational models to model thrombus formation and material behaviour.


Asunto(s)
Modelos Teóricos , Trombosis , Animales , Fenómenos Biomecánicos , Diseño de Equipo , Humanos , Trombectomía/instrumentación
4.
J Radiol Prot ; 36(1): 104-16, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26807676

RESUMEN

Seven different types of radon detectors (Atmos 12 dpx, RAD7, RStone, Sun Nuclear 1028, Ramon 2.2, Canary and CR-39) were compared for exposure periods of 1, 2, 3 and 4 weeks. The comparison was conducted under two conditions: (a) in a purpose-built radon chamber with an average radon concentration of 2560 Bq m(-3) (b) in a home environment with a radon concentration of 57 Bq m(-3), in both cases measured by the reference detector (Atmos 12 dpx) with a ±10% uncertainty range. In (a) 5 out of 8 detectors recorded radon concentrations within the Atmos uncertainty range and all detectors recorded within ±15%; in (b) 3 out of 9 detectors recorded within the Atmos uncertainty range and 6 out of 9 measured within ±20%, for a 4 week measurement. The results from this study show that radon surveys can be conducted for shorter periods than the recommended 3 months where a rapid indication is needed of whether the radon concentration is above the reference level, such as when assessing the concentration during and after remediation work.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Contaminación del Aire Interior/análisis , Monitoreo de Radiación/instrumentación , Radón/análisis
5.
J Radiol Prot ; 34(2): 457-67, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24894188

RESUMEN

Long term outdoor radon measurements were recorded in Ireland using CR-39 track etch detectors. A measurement protocol was designed for this study, which was optimized for the relatively low radon concentrations expected outdoors. This protocol included pre-etching the detectors before exposure to allow radon tracks to be more easily distinguished from background. The average outdoor radon concentration for the Republic of Ireland was found to be 5.6 ± 0.7 Bq m(-3). A statistically significant difference between inland and coastal radon concentrations was evident but no difference between mean radon concentrations on the east coast and those on the west coast was observed.


Asunto(s)
Algoritmos , Radiación de Fondo , Dispositivos Ópticos , Monitoreo de Radiación/instrumentación , Radón/análisis , Diseño de Equipo , Análisis de Falla de Equipo , Irlanda , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Med Eng Phys ; 23(1): 37-43, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11344006

RESUMEN

To gain a better understanding of the effects of chronic stimulation on mammalian muscles we needed to generate patterns of greater variety and complexity than simple constant-frequency or burst patterns. We describe here two approaches to the design of implantable neuromuscular stimulators that can satisfy these requirements. Devices of both types were developed and used in long-term experiments. The first device was based on a semi-custom Application Specific Integrated Circuit (ASIC). This approach has the advantage that the circuit can be completely tested at every stage of development and production, assuring a high degree of reliability. It has the drawback of inflexibility: the patterns are produced by state machines implemented in silicon, so each new set of patterns requires a fresh production run, which is costly and time-consuming. The second device was based on a commercial microcontroller (Microchip PIC16C84). The functionality of this type of circuit is specified in software rather than in silicon hardware, allowing a single device to be programmed for different functions. With the use of features designed to improve fault-tolerance we found this approach to be as reliable as that based on ASICs. The encapsulated devices can easily be accommodated subcutaneously on the flank of a rabbit and a recent version is small enough to implant into the peritoneal cavity of rats. The current devices are programmed with a predetermined set of 12 patterns before assembly; the desired pattern is selected after implantation with an electronic flash gun. The operating current drain is less than 40 microA.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Prótesis e Implantes , Animales , Ingeniería Biomédica , Sistemas de Computación , Humanos , Diseño de Prótesis , Ratas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...