Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 989
Filtrar
1.
Phys Rev Lett ; 132(16): 163603, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38701459

RESUMEN

Phonon-based frequency combs that can be generated in the optical and microwave frequency domains have attracted much attention due to the small repetition rates and the simple setup. Here, we experimentally demonstrate a new type of phonon-based frequency comb in a silicon optomechanical crystal cavity including both a breathing mechanical mode (∼GHz) and flexural mechanical modes (tens of MHz). We observe strong mode competition between two approximate flexural mechanical modes, i.e., 77.19 and 90.17 MHz, resulting in only one preponderant lasing, while maintaining the lasing of the breathing mechanical mode. These simultaneous observations of two-mode phonon lasing state and significant mode competition are counterintuitive. We have formulated comprehensive theories to elucidate this phenomenon in response to this intriguing outcome. In particular, the self-pulse induced by the free carrier dispersion and thermo-optic effects interacts with two approximate flexural mechanical modes, resulting in the repetition rate of the comb frequency-locked to exact fractions of one of the flexural mechanical modes and the mode hopping between them. This phonon-based frequency comb has at least 260 comblines and a repetition rate as low as a simple fraction of the flexural mechanical frequency. Our demonstration offers an alternative optomechanical frequency comb for sensing, timing, and metrology applications.

2.
Phys Rev Lett ; 132(16): 160201, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38701466

RESUMEN

Quantum theory allows information to flow through a single device in a coherent superposition of two opposite directions, resulting into situations where the input-output direction is indefinite. Here we introduce a theoretical method to witness input-output indefiniteness in a single quantum device, and we experimentally demonstrate it by constructing a photonic setup that exhibits input-output indefiniteness with a statistical significance exceeding 69 standard deviations. Our results provide a way to characterize input-output indefiniteness as a resource for quantum information and photonic quantum technologies and enable tabletop simulations of hypothetical scenarios exhibiting quantum indefiniteness in the direction of time.

3.
Sci Adv ; 10(18): eadj3435, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38691593

RESUMEN

Quantum entanglement and decoherence are the two counterforces of many quantum technologies and protocols. For example, while quantum teleportation is fueled by a pair of maximally entangled resource qubits, it is vulnerable to decoherence. Here, we propose an efficient quantum teleportation protocol in the presence of pure decoherence and without entangled resource qubits entering the Bell-state measurement. Instead, we use multipartite hybrid entanglement between the auxiliary qubits and their local environments within the open-quantum system context. With a hybrid-entangled initial state, it is the decoherence that allows us to achieve high fidelities. We demonstrate our protocol in an all-optical experiment.

4.
Chin J Traumatol ; 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38762418

RESUMEN

PURPOSE: Intertrochanteric fracture (ITF) classification is crucial for surgical decision-making. However, orthopedic trauma surgeons have shown lower accuracy in ITF classification than expected. The objective of this study was to utilize an artificial intelligence (AI) method to improve the accuracy of ITF classification. METHODS: We trained a network called YOLOX-SwinT, which is based on the You Only Look Once X (YOLOX) object detection network with Swin Transformer (SwinT) as the backbone architecture, using 762 radiographic ITF examinations as the training set. Subsequently, we recruited 5 senior orthopedic trauma surgeons (SOTS) and 5 junior orthopedic trauma surgeons (JOTS) to classify the 85 original images in the test set, as well as the images with the prediction results of the network model in sequence. Statistical analysis was performed using the Statistical Package for the Social Sciences (SPSS) 20.0 (IBM Corp., Armonk, NY, USA) to compare the differences among the SOTS, JOTS, SOTS + AI, JOTS + AI, SOTS + JOTS, and SOTS + JOTS + AI groups. All images were classified according to the AO/OTA 2018 classification system by 2 experienced trauma surgeons and verified by another expert in this field. Based on the actual clinical needs, after discussion, we integrated 8 subgroups into 5 new subgroups, and the dataset was divided into training, validation, and test sets by the ratio of 8:1:1. RESULTS: The mean average precision at the intersection over union (IoU) of 0.5 (mAP50) for subgroup detection reached 90.29%. The classification accuracy values of SOTS, JOTS, SOTS + AI, and JOTS + AI groups were 56.24% ± 4.02%, 35.29% ± 18.07%, 79.53% ± 7.14%, and 71.53% ± 5.22%, respectively. The paired t-test results showed that the difference between the SOTS and SOTS + AI groups was statistically significant, as well as the difference between the JOTS and JOTS + AI groups, and the SOTS + JOTS and SOTS + JOTS + AI groups. Moreover, the difference between the SOTS + JOTS and SOTS + JOTS + AI groups in each subgroup was statistically significant, with all p < 0.05. The independent samples t-test results showed that the difference between the SOTS and JOTS groups was statistically significant, while the difference between the SOTS + AI and JOTS + AI groups was not statistically significant. With the assistance of AI, the subgroup classification accuracy of both SOTS and JOTS was significantly improved, and JOTS achieved the same level as SOTS. CONCLUSION: In conclusion, the YOLOX-SwinT network algorithm enhances the accuracy of AO/OTA subgroups classification of ITF by orthopedic trauma surgeons.

5.
Phys Rev Lett ; 132(13): 133603, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38613308

RESUMEN

An integrated quantum light source is increasingly desirable in large-scale quantum information processing. Despite recent remarkable advances, a new material platform is constantly being explored for the fully on-chip integration of quantum light generation, active and passive manipulation, and detection. Here, for the first time, we demonstrate a gallium nitride (GaN) microring based quantum light generation in the telecom C-band, which has potential toward the monolithic integration of quantum light source. In our demonstration, the GaN microring has a free spectral range of 330 GHz and a near-zero anomalous dispersion region of over 100 nm. The generation of energy-time entangled photon pair is demonstrated with a typical raw two-photon interference visibility of 95.5±6.5%, which is further configured to generate a heralded single photon with a typical heralded second-order autocorrelation g_{H}^{(2)}(0) of 0.045±0.001. Our results pave the way for developing a chip-scale quantum photonic circuit.

6.
Phys Rev Lett ; 132(11): 110801, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38563910

RESUMEN

Reducing the average resource consumption is the central quest in discriminating non-orthogonal quantum states for a fixed admissible error rate ϵ. The globally optimal fixed local projective measurement for this task is found to be different from that for previous minimum-error discrimination tasks [S. Slussarenko et al., Phys. Rev. Lett. 118, 030502 (2017)PRLTAO0031-900710.1103/PhysRevLett.118.030502]. To achieve the ultimate minimum average consumption, here we develop a general globally optimal adaptive strategy (GOA) by subtly using the updated posterior probability, which works under any error rate requirements and any one-way measurement restrictions, and can be solved by a convergent iterative relation. First, under the local measurement restrictions, our GOA is solved to serve as the local bound, which saves 16.6 copies (24%) compared with the previously best globally optimal fixed local projective measurement. When the more powerful two-copy collective measurements are allowed, our GOA is experimentally demonstrated to beat the local bound by 3.9 copies (6.0%). By exploiting both adaptivity and collective measurements, our Letter marks an important step toward minimum-consumption quantum state discrimination.

7.
Angew Chem Int Ed Engl ; : e202402374, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38655601

RESUMEN

The construction of secondary building units (SBUs) in versatile metal-organic frameworks (MOFs) represents a promising method for developing multi-functional materials, especially for improving their sensitizing ability. Herein, we developed a dual small molecules auxiliary strategy to construct a high-nuclear transition-metal-based UiO-architecture Co16-MOF-BDC with visible-light-absorbing capacity. Remarkably, the N3- molecule in hexadecameric cobalt azide SBU offers novel modification sites to precise bonding of strong visible-light-absorbing chromophores via click reaction. The resulting Bodipy@Co16-MOF-BDC exhibits extremely high performance for oxidative coupling benzylamine (~100% yield) via both energy and electron transfer processes, which is much superior to that of Co16-MOF-BDC (31.5%) and Carboxyl Bodipy@Co16-MOF-BDC (37.5%). Systematic investigations reveal that the advantages of Bodipy@Co16-MOF-BDC in dual light-absorbing channels, robust bonding between Bodipy/Co16 clusters and efficient electron-hole separation can greatly boost photosynthesis. This work provides an ideal molecular platform for synergy between photosensitizing MOFs and chromophores by constructing high-nuclear transition-metal-based SBUs with surface-modifiable small molecules.

9.
BMC Anesthesiol ; 24(1): 130, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38580909

RESUMEN

BACKGROUND: Skin mottling is a common manifestation of peripheral tissue hypoperfusion, and its severity can be described using the skin mottling score (SMS). This study aims to evaluate the value of the SMS in detecting peripheral tissue hypoperfusion in critically ill patients following cardiac surgery. METHODS: Critically ill patients following cardiac surgery with risk factors for tissue hypoperfusion were enrolled (n = 373). Among these overall patients, we further defined a hypotension population (n = 178) and a shock population (n = 51). Hemodynamic and perfusion parameters were recorded. The primary outcome was peripheral hypoperfusion, defined as significant prolonged capillary refill time (CRT, > 3.0 s). The characteristics and hospital mortality of patients with and without skin mottling were compared. The area under receiver operating characteristic curves (AUROC) were used to assess the accuracy of SMS in detecting peripheral hypoperfusion. Besides, the relationships between SMS and conventional hemodynamic and perfusion parameters were investigated, and the factors most associated with the presence of skin mottling were identified. RESULTS: Of the 373-case overall population, 13 (3.5%) patients exhibited skin mottling, with SMS ranging from 1 to 5 (5, 1, 2, 2, and 3 cases, respectively). Patients with mottling had lower mean arterial pressure, higher vasopressor dose, less urine output (UO), higher CRT, lactate levels and hospital mortality (84.6% vs. 12.2%, p < 0.001). The occurrences of skin mottling were higher in hypotension population and shock population, reaching 5.6% and 15.7%, respectively. The AUROC for SMS to identify peripheral hypoperfusion was 0.64, 0.68, and 0.81 in the overall, hypotension, and shock populations, respectively. The optimal SMS threshold was 1, which corresponded to specificities of 98, 97 and 91 and sensitivities of 29, 38 and 67 in the three populations (overall, hypotension and shock). The correlation of UO, lactate, CRT and vasopressor dose with SMS was significant, among them, UO and CRT were identified as two major factors associated with the presence of skin mottling. CONCLUSION: In critically ill patients following cardiac surgery, SMS is a very specific yet less sensitive parameter for detecting peripheral tissue hypoperfusion.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Hipotensión , Choque Séptico , Humanos , Enfermedad Crítica , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Hipotensión/diagnóstico , Hipotensión/complicaciones , Lactatos
10.
Proc Natl Acad Sci U S A ; 121(17): e2314353121, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38635634

RESUMEN

Auxin regulates plant growth and development through downstream signaling pathways, including the best-known SCFTIR1/AFB-Aux/IAA-ARF pathway and several other less characterized "noncanonical" pathways. Recently, one SCFTIR1/AFB-independent noncanonical pathway, mediated by Transmembrane Kinase 1 (TMK1), was discovered through the analyses of its functions in Arabidopsis apical hook development. Asymmetric accumulation of auxin on the concave side of the apical hook triggers DAR1-catalyzed release of the C-terminal of TMK1, which migrates into the nucleus, where it phosphorylates and stabilizes IAA32/34 to inhibit cell elongation, which is essential for full apical hook formation. However, the molecular factors mediating IAA32/34 degradation have not been identified. Here, we show that proteins in the CYTOKININ INDUCED ROOT WAVING 1 (CKRW1)/WAVY GROWTH 3 (WAV3) subfamily act as E3 ubiquitin ligases to target IAA32/34 for ubiquitination and degradation, which is inhibited by TMK1c-mediated phosphorylation. This antagonistic interaction between TMK1c and CKRW1/WAV3 subfamily E3 ubiquitin ligases regulates IAA32/34 levels to control differential cell elongation along opposite sides of the apical hook.


Asunto(s)
Proteínas de Arabidopsis , Arabidopsis , Proteínas F-Box , Ubiquitina-Proteína Ligasas/genética , Ubiquitina-Proteína Ligasas/metabolismo , Proteínas de Arabidopsis/genética , Proteínas de Arabidopsis/metabolismo , Arabidopsis/metabolismo , Ácidos Indolacéticos/metabolismo , Transducción de Señal , Ubiquitinas/metabolismo , Regulación de la Expresión Génica de las Plantas , Proteínas F-Box/genética , Proteínas F-Box/metabolismo
11.
Opt Lett ; 49(7): 1729-1732, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38560848

RESUMEN

Soliton microcombs are regarded as an ideal platform for applications such as optical communications, optical sensing, low-noise microwave sources, optical atomic clocks, and frequency synthesizers. Many of these applications require a broad comb spectrum that covers an octave, essential for implementing the f - 2f self-referencing techniques. In this work, we have successfully generated an octave-spanning soliton microcomb based on a z-cut thin-film lithium niobate (TFLN) microresonator. This achievement is realized under on-chip optical pumping at 340 mW and through extensive research into the broadening of dual dispersive waves (DWs). Furthermore, the repetition rate of the octave soliton microcomb is accurately measured using an electro-optic comb generated by an x-cut TFLN racetrack microresonator. Our results represent a crucial step toward the realization of practical, integrated, and fully stabilized soliton microcomb systems based on TFLN.

12.
Sci Adv ; 10(11): eadl4871, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38489356

RESUMEN

Noise-enhanced applications in open quantum walk (QW) has recently seen a surge due to their ability to improve performance. However, verifying the success of open QW is challenging, as mixed-state tomography is a resource-intensive process, and implementing all required measurements is almost impossible due to various physical constraints. To address this challenge, we present a neural-network-based method for reconstructing mixed states with a high fidelity (∼97.5%) while costing only 50% of the number of measurements typically required for open discrete-time QW in one dimension. Our method uses a neural density operator that models the system and environment, followed by a generalized natural gradient descent procedure that significantly speeds up the training process. Moreover, we introduce a compact interferometric measurement device, improving the scalability of our photonic QW setup that enables experimental learning of mixed states. Our results demonstrate that highly expressive neural networks can serve as powerful alternatives to traditional state tomography.

13.
Light Sci Appl ; 13(1): 74, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38485915

RESUMEN

Photonic quantum computation plays an important role and offers unique advantages. Two decades after the milestone work of Knill-Laflamme-Milburn, various architectures of photonic processors have been proposed, and quantum advantage over classical computers has also been demonstrated. It is now the opportune time to apply this technology to real-world applications. However, at current technology level, this aim is restricted by either programmability in bulk optics or loss in integrated optics for the existing architectures of processors, for which the resource cost is also a problem. Here we present a von-Neumann-like architecture based on temporal-mode encoding and looped structure on table, which is capable of multimode-universal programmability, resource-efficiency, phase-stability and software-scalability. In order to illustrate these merits, we execute two different programs with varying resource requirements on the same processor, to investigate quantum signature of chaos from two aspects: the signature behaviors exhibited in phase space (13 modes), and the Fermi golden rule which has not been experimentally studied in quantitative way before (26 modes). The maximal program contains an optical interferometer network with 1694 freely-adjustable phases. Considering current state-of-the-art, our architecture stands as the most promising candidate for real-world applications.

14.
J Environ Manage ; 356: 120623, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38518494

RESUMEN

The environmental pollution caused by azo dyes at high temperatures has become an urgent problem. However, little attention has been paid to decolorizing azo dyes by thermophilic consortiums. In this study, a thermophilic bacterial consortium (BCGR-T) mainly composed of two genera, namely, Caldibacillus (70.90%) and Aeribacillus (17.63%) was first enriched, which can decolorize Brilliant Crocein GR (BCGR) at high temperatures (50-75 °C), pH values of 6∼8, dye concentrations (100-400 mg/L) and salinities (1-5%, w/v). The enzyme activity results showed that the azoreductase activity was nearly 8.8 times that of the control (p < 0.01), and the intracellular lignin peroxidase was also highly expressed with enzyme activity of 5.64 U (min-1 mg-1 protein) (p < 0.05), indicated that both azoreductase and intracellular lignin peroxidase played an important part in the decolorization process. Furthermore, seven new intermediate metabolic products, including aniline, phthalic acid, 2-carboxy benzaldehyde, phenylacetic acid, benzoic acid, toluene, and 4-methyl-hexanoic acid, were identified. In addition, functional genes related with the azo dye decolorization, such as those encoding the azoreductase, laccase, FMN reductase, NADPH-/NADH-quinone oxidoreductases and NADPH-/NADH dehydrogenases, catechol dioxygenase, homogentisate 1,2-dioxygenase, protocatechuate 3,4-dioxygenase, gentisate 1,2-dioxygenase, azobenzene reductase, naphthalene 1,2-dioxygenase, benzoate/toluate 1,2-dioxygenase, and anthranilate 1,2-dioxygenase and so on were found in the metagenome of the consortium BCGR-T. Finally, a new decolorization pathway of the thermophilic consortium BCGR-T was proposed. In addition, the phototoxicity of BCGR decreased after decolorization. Overall, the thermophilic consortium BCGR-T could be a promising candidate in the treatment of high concentration azo dye wastewater at high temperatures.


Asunto(s)
Dioxigenasas , NAD , Naftalenosulfonatos , NADP , Biodegradación Ambiental , Compuestos Azo , Colorantes
15.
Phys Rev Lett ; 132(7): 070203, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38427853

RESUMEN

Uncertainty relations for Hermitian operators have been confirmed through many experiments. However, previous experiments have only tested the special case of non-Hermitian operators, i.e., uncertainty relations for unitary operators. In this study, we explore uncertainty relations for general non-Hermitian operators, which include Hermitian and unitary operators as special cases. We perform experiments with both real and complex non-Hermitian operators for qubit states, and confirm the validity of the uncertainty relations within the experimental error. Our results provide experimental evidence of uncertainty relations for non-Hermitian operators. Furthermore, our methods for realizing and measuring non-Hermitian operators are valuable in characterizing open-system dynamics and enhancing parameter estimation.

16.
Phys Rev Lett ; 132(8): 080202, 2024 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-38457709

RESUMEN

Quantum measurements based on mutually unbiased bases (MUBs) play crucial roles in foundational studies and quantum information processing. It is known that there exist inequivalent MUBs, but little is known about their operational distinctions, not to say experimental demonstration. In this Letter, by virtue of a simple estimation problem, we experimentally demonstrate the operational distinctions between inequivalent triples of MUBs in dimension 4 based on high-precision photonic systems. The experimental estimation fidelities coincide well with the theoretical predictions with only 0.16% average deviation, which is 25 times less than the difference (4.1%) between the maximum estimation fidelity and the minimum estimation fidelity. Our experiments clearly demonstrate that inequivalent MUBs have different information extraction capabilities and different merits for quantum information processing.

17.
Appl Opt ; 63(7): 1719-1726, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38437271

RESUMEN

On-chip acousto-optic modulators that operate at an optical wavelength of 780 nm and a microwave frequency of 6.835 GHz are proposed. The modulators are based on a lithium-niobate-on-sapphire platform and efficiently excite surface acoustic waves and exhibit strong interactions with tightly confined optical modes in waveguides. In particular, a high-efficiency phase modulator and single-sideband mode converter are designed. We found that for both microwave and optical wavelengths below 1 µm, the interactions at the cross-sections of photonic waveguides are sensitive to the waveguide width and are significantly different from those in previous studies. Our designed devices have small footprints and high efficiencies, making them suitable for controlling rubidium atoms and realizing hybrid photonic-atomic chips. Furthermore, our devices have the potential to extend the acousto-optic modulators to other visible wavelengths for other atom transitions and for visible light applications, including imaging and sensing.

18.
Anim Biosci ; 37(6): 1065-1076, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38419533

RESUMEN

OBJECTIVE: This study aimed to assess the effects of dietary mulberry leaves on the growth, production performance, gut microbiota, and immunological parameters of poultry and livestock. METHODS: The PubMed, Embase, and Scopus databases were systematically analyzed to identify pertinent studies up to December 2022. The effects of mulberry leaf diet was assessed using the weighted mean difference, and the 95% confidence interval was calculated using a random-effects model. RESULTS: In total, 18 studies that sampled 2,335 poultry and livestock were selected for analysis. Mulberry leaves improved the average daily gain and reduced the feed/meat ratio in finishing pigs, and the average daily gain and average daily feed intake in chicken. In production performance, mulberry leaves lowered the half carcass weight, slaughter rate, and loin eye area in pigs, and the slaughter rate in chickens. Regarding meat quality in pigs, mulberry leaves reduced the cooked meat percentage, shear force, crude protein, and crude ash, and increased the 24 h pH and water content. In chickens, it increased the drip loss, shear force, 45 min and 24 h pH, crude protein, and crude ash. Mulberry leaves also affect the abundances of gut microbiota, including Bacteroides, Prevotella, Megamonas, Escherichia-Shigella, Butyricicoccus, unclassified Ruminococcaceae, Bifidobacterium, Lactobacillus, and Escherichia coli in poultry and livestock. Mulberry leaves at different doses were associated with changes in antioxidant capacity in chickens, and immune organ indexes in pigs. With respect to egg quality, mulberry leaves at different doses improved the shell strength, yolk color, eggshell thickness, and eggshell weight. However, moderate doses diminished the egg yolk ratio and the egg yolk moisture content. CONCLUSION: In general, dietary mulberry leaves improved the growth, production performance, and immunological parameters in poultry and livestock, although the effects varied at different doses.

19.
Jpn J Radiol ; 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38381250

RESUMEN

PURPOSE: To evaluate the diagnostic accuracy of abdominal contrast-enhanced multi-slice spiral CT after oral diluted iodide in a time segment (post-ODI ACE-MSCT) for gastrointestinal fistula (GIF) in severe acute pancreatitis (SAP). MATERIALS AND METHODS: Patients with SAP who underwent both post-ODI ACE-MSCT and endoscopy/surgery from 2017 to 2023 were continuously retrospectively involved. Their demographic information and clinical features were recorded prospectively in an in-hospital database. Using endoscopy/surgery results as the reference standard, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of post-ODI ACE-MSCT for diagnosing GIF in SAP were calculated by a four-cell table. The consistency of the two diagnostic methods was evaluated by the Kappa test and McNemar's test. RESULTS: Using endoscopy/surgery as the reference standard, a total of 86 cases were divided into the GIF group (N = 52) and the non-GIF group (N = 34). Among the 52 cases of GIF, 88.5% (46/52) cases had a positive result and 11.5% (5/52) cases had a negative result of post-ODI ACE-MSCT for GIF. Among the 34 cases of non-GIF, 2.9% (1/34) case had a positive result and 97.1% (33/34) cases had a negative result of post-ODI ACE-MSCT for GIF. Post-ODI ACE-MSCT had a sensitivity of 88.5% (95% CI 75.9%-95.2%), a specificity of 97.1% (95% CI 82.9%-99.8%), a positive predictive value of 97.9% (95% CI 87.3%-99.9%), a negative predictive value of 84.6% (95% CI 68.8%-93.6%), and an accuracy of 91.9% (83.4%-96.4%). The kappa value was 0.834, and P < 0.001 by McNemar's test. There were no significant differences in diagnostic test characteristics between the two modalities. CONCLUSION: Post-ODI ACE-MSCT can diagnose GIF in SAP in a simple, noninvasive, and accurate way, and can provide earlier imaging evidence for clinical diagnosis and treatment.

20.
Opt Express ; 32(3): 2906-2915, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38297527

RESUMEN

We present a novel micro-fabrication technique for creating concave surfaces on the endfacets of photonic crystal fibers. A fiber fusion splicer is used to generate arc discharges to melt and reshape the fiber endfacet. This technique can produce large spherical concave surfaces with roughness as low as 0.12 nm in various types of photonic crystal fibers. The deviation of fabricated surface and a spherical profile in the region of 70 µm in diameter is less than 50 nm. The center of the concave surface and the fiber mode field are highly coincident with a deviation less than 500 nm. Finesse measurements have shown that a Fabry-Pérot cavity composed of the fiber fabricated using this method and a plane mirror maintains finesse of 20000. This method is easy to replicate, making it a practical and efficient approach to fabricate concave surface on fibers for open-access fiber Fabry-Pérot cavities.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...