Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sci Rep ; 14(1): 15273, 2024 07 03.
Artículo en Inglés | MEDLINE | ID: mdl-38961109

RESUMEN

Imbalances in electrolyte concentrations can have severe consequences, but accurate and accessible measurements could improve patient outcomes. The current measurement method based on blood tests is accurate but invasive and time-consuming and is often unavailable for example in remote locations or an ambulance setting. In this paper, we explore the use of deep neural networks (DNNs) for regression tasks to accurately predict continuous electrolyte concentrations from electrocardiograms (ECGs), a quick and widely adopted tool. We analyze our DNN models on a novel dataset of over 290,000 ECGs across four major electrolytes and compare their performance with traditional machine learning models. For improved understanding, we also study the full spectrum from continuous predictions to a binary classification of extreme concentration levels. Finally, we investigate probabilistic regression approaches and explore uncertainty estimates for enhanced clinical usefulness. Our results show that DNNs outperform traditional models but model performance varies significantly across different electrolytes. While discretization leads to good classification performance, it does not address the original problem of continuous concentration level prediction. Probabilistic regression has practical potential, but our uncertainty estimates are not perfectly calibrated. Our study is therefore a first step towards developing an accurate and reliable ECG-based method for electrolyte concentration level prediction-a method with high potential impact within multiple clinical scenarios.


Asunto(s)
Electrocardiografía , Electrólitos , Electrocardiografía/métodos , Humanos , Electrólitos/sangre , Redes Neurales de la Computación , Análisis de Regresión , Aprendizaje Automático
2.
Artículo en Inglés | MEDLINE | ID: mdl-37007801

RESUMEN

At very low energies, a light neutral particle above a horizontal surface can experience quantum reflection. The quantum reflection holds the particle against gravity and leads to gravitational quantum states (gqs). So far, gqs were only observed with neutrons as pioneered by Nesvizhevsky and his collaborators at ill. However, the existence of gqs is predicted also for atoms. The Grasian collaboration pursues the first observation and studies of gqs of atomic hydrogen. We propose to use atoms in order to exploit the fact that orders of magnitude larger fluxes compared to those of neutrons are available. Moreover, recently the q-Bounce collaboration, performing gqs spectroscopy with neutrons, reported a discrepancy between theoretical calculations and experiment which deserves further investigations. For this purpose, we set up a cryogenic hydrogen beam at 6  K . We report on our preliminary results, characterizing the hydrogen beam with pulsed laser ionization diagnostics at 243  nm .

3.
Vaccines (Basel) ; 10(8)2022 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-36016162

RESUMEN

The term hybrid immunity is used to denote the immunological status of vaccinated individuals with a history of natural infection. Reports of new SARS-CoV-2 variants of concern motivate continuous rethought and renewal of COVID-19 vaccination programs. We used a naturalistic case-control study design to compare the effectiveness of the BNT162b2 mRNA vaccine to hybrid immunity 180 days post-vaccination in prioritized and non-prioritized populations vaccinated before 31 July 2021 in three Swedish counties (total population 1,760,000). Subjects with a positive SARS-CoV-2 test recorded within 6 months before vaccination (n = 36,247; 6%) were matched to vaccinated-only controls. In the prioritized population exposed to the SARS-CoV-2 Alpha and Delta variants post-vaccination, the odds ratio (OR) for breakthrough infection was 2.2 (95% CI, 1.6−2.8; p < 0.001) in the vaccinated-only group compared with the hybrid immunity group, while in the later vaccinated non-prioritized population, the OR decreased from 4.3 (95% CI, 2.2−8.6; p < 0.001) during circulation of the Delta variant to 1.9 (95% CI, 1.7−2.1; p < 0.001) with the introduction of the Omicron variant (B.1.617.2). We conclude that hybrid immunity provides gains in protection, but that the benefits are smaller for risk groups and with circulation of the Omicron variant and its sublineages.

4.
Emerg Infect Dis ; 28(3): 564-571, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35201737

RESUMEN

We report on local nowcasting (short-term forecasting) of coronavirus disease (COVID-19) hospitalizations based on syndromic (symptom) data recorded in regular healthcare routines in Östergötland County (population ≈465,000), Sweden, early in the pandemic, when broad laboratory testing was unavailable. Daily nowcasts were supplied to the local healthcare management based on analyses of the time lag between telenursing calls with the chief complaints (cough by adult or fever by adult) and COVID-19 hospitalization. The complaint cough by adult showed satisfactory performance (Pearson correlation coefficient r>0.80; mean absolute percentage error <20%) in nowcasting the incidence of daily COVID-19 hospitalizations 14 days in advance until the incidence decreased to <1.5/100,000 population, whereas the corresponding performance for fever by adult was unsatisfactory. Our results support local nowcasting of hospitalizations on the basis of symptom data recorded in routine healthcare during the initial stage of a pandemic.


Asunto(s)
COVID-19 , Adulto , COVID-19/epidemiología , Atención a la Salud , Predicción , Hospitalización , Humanos , SARS-CoV-2 , Suecia/epidemiología
5.
Sci Rep ; 11(1): 23963, 2021 12 14.
Artículo en Inglés | MEDLINE | ID: mdl-34907208

RESUMEN

We demonstrate that finite impulse response (FIR) models can be applied to analyze the time evolution of an epidemic with its impact on deaths and healthcare strain. Using time series data for COVID-19-related cases, ICU admissions and deaths from Sweden, the FIR model gives a consistent epidemiological trajectory for a simple delta filter function. This results in a consistent scaling between the time series if appropriate time delays are applied and allows the reconstruction of cases for times before July 2020, when RT-PCR testing was not widely available. Combined with randomized RT-PCR study results, we utilize this approach to estimate the total number of infections in Sweden, and the corresponding infection-to-fatality ratio (IFR), infection-to-case ratio (ICR), and infection-to-ICU admission ratio (IIAR). Our values for IFR, ICR and IIAR are essentially constant over large parts of 2020 in contrast with claims of healthcare adaptation or mutated virus variants importantly affecting these ratios. We observe a diminished IFR in late summer 2020 as well as a strong decline during 2021, following the launch of a nation-wide vaccination program. The total number of infections during 2020 is estimated to 1.3 million, indicating that Sweden was far from herd immunity.


Asunto(s)
COVID-19/epidemiología , Mortalidad/tendencias , SARS-CoV-2/aislamiento & purificación , COVID-19/mortalidad , Prueba de Ácido Nucleico para COVID-19 , Análisis de Elementos Finitos , Hospitalización/estadística & datos numéricos , Humanos , Unidades de Cuidados Intensivos , SARS-CoV-2/genética , Suecia/epidemiología , Factores de Tiempo
6.
Comput Med Imaging Graph ; 93: 101994, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34624770

RESUMEN

Along with rich health-related metadata, medical images have been acquired for over 40,000 male and female UK Biobank participants, aged 44-82, since 2014. Phenotypes derived from these images, such as measurements of body composition from MRI, can reveal new links between genetics, cardiovascular disease, and metabolic conditions. In this work, six measurements of body composition and adipose tissues were automatically estimated by image-based, deep regression with ResNet50 neural networks from neck-to-knee body MRI. Despite the potential for high speed and accuracy, these networks produce no output segmentations that could indicate the reliability of individual measurements. The presented experiments therefore examine uncertainty quantification with mean-variance regression and ensembling to estimate individual measurement errors and thereby identify potential outliers, anomalies, and other failure cases automatically. In 10-fold cross-validation on data of about 8500 subjects, mean-variance regression and ensembling showed complementary benefits, reducing the mean absolute error across all predictions by 12%. Both improved the calibration of uncertainties and their ability to identify high prediction errors. With intra-class correlation coefficients (ICC) above 0.97, all targets except the liver fat content yielded relative measurement errors below 5%. Testing on another 1000 subjects showed consistent performance, and the method was finally deployed for inference to 30,000 subjects with missing reference values. The results indicate that deep regression ensembles could ultimately provide automated, uncertainty-aware measurements of body composition for more than 120,000 UK Biobank neck-to-knee body MRI that are to be acquired within the coming years.


Asunto(s)
Bancos de Muestras Biológicas , Imagen por Resonancia Magnética , Composición Corporal , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Incertidumbre , Reino Unido
7.
Lakartidningen ; 1182021 05 20.
Artículo en Sueco | MEDLINE | ID: mdl-34014556

RESUMEN

The Imperial College COVID-19 Response Team (ICCRT) concluded in a series of high-profile reports that lockdown had been the most effective non-pharmaceutical intervention in 11 European countries during the initial phase of the corona pandemic. As the ICCRT used a transparent modeling framework, we were able to examine assumptions made in the model. We found that the ICCRT modified the assumptions made in their model as more data became available in a way that maintained the conclusion that lockdown was most effective. These observations suggest that modeling of non-pharmaceutical interventions during an ongoing pandemic must be interpreted with caution as sources of error can be found both in the technical execution of the modeling and the assumptions made. The secondary analysis was made possible only because the ICCRT published their methodology in detail, which is a prerequisite for scientific progress in the pandemic modeling area.


Asunto(s)
COVID-19 , Pandemias , Control de Enfermedades Transmisibles , Europa (Continente) , Humanos , Pandemias/prevención & control , SARS-CoV-2
9.
IFAC Pap OnLine ; 53(5): 829-832, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-38620619

RESUMEN

The Covid-19 pandemic has spawned numerous dynamic modeling attempts aimed at estimation, prediction, and ultimately control. The predictive power of these attempts has varied, and there remains a lack of consensus regarding the mechanisms of virus spread and the effectiveness of various non-pharmaceutical interventions that have been enforced regionally as well as nationally. Setting out in data available in the spring of 2020, and with a now-famous model by Imperial College researchers as example, we employ an information-theoretical approach to shed light on why the predictive power of early modeling approaches have remained disappointingly poor.

10.
Int J Artif Organs ; 42(12): 717-724, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31250690

RESUMEN

INTRODUCTION: The HeartMate 3™ has shown lower rates of adverse events compared to previous devices due to the design and absence of mechanical bearings. For previous devices, sound analysis emerged as a way to assess pump function. The aims of this study were to determine if sound analysis can be applied to the HeartMate 3 in vivo and in vitro and to evaluate an electronic stethoscope. METHOD: Sound recordings were performed with microphones and clinical accessible electronic stethoscope. The recordings were studied in both the time and the frequency domains. Recordings from four patients were performed to determine if in vivo and in vitro recordings are comparable. RESULTS: The results show that it is possible to detect sound from HeartMate 3 and the sound spectrum is clear. Pump frequency and frequency of the pulsatile mode are easily determined. Frequency spectra from in vitro and in vivo recordings have the same pattern, and the major proportion (96.7%) of signal power is located at the pump speed frequency ±40 Hz. The recordings from the patients show low inter-individual differences except from location of peaks originating from pump speed and harmonics. Electronic stethoscopes could be used for sound recordings, but the dedicated equipment showed a clearer sound spectrum. DISCUSSION: The results show that acoustic analysis can also be performed with the HeartMate 3 and that in vivo and in vitro sound spectrum is similar. The frequency spectra are different from previous devices, and methods for assessing pump function or thrombosis need further evaluation.


Asunto(s)
Análisis de Falla de Equipo , Corazón Auxiliar , Sonido , Diseño de Equipo , Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/métodos , Femenino , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/cirugía , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar/efectos adversos , Corazón Auxiliar/normas , Humanos , Magnetometría/métodos , Masculino , Persona de Mediana Edad , Mejoramiento de la Calidad , Análisis Espectral/métodos
11.
Front Neurosci ; 13: 153, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30941002

RESUMEN

Auditory attention identification methods attempt to identify the sound source of a listener's interest by analyzing measurements of electrophysiological data. We present a tutorial on the numerous techniques that have been developed in recent decades, and we present an overview of current trends in multivariate correlation-based and model-based learning frameworks. The focus is on the use of linear relations between electrophysiological and audio data. The way in which these relations are computed differs. For example, canonical correlation analysis (CCA) finds a linear subset of electrophysiological data that best correlates to audio data and a similar subset of audio data that best correlates to electrophysiological data. Model-based (encoding and decoding) approaches focus on either of these two sets. We investigate the similarities and differences between these linear model philosophies. We focus on (1) correlation-based approaches (CCA), (2) encoding/decoding models based on dense estimation, and (3) (adaptive) encoding/decoding models based on sparse estimation. The specific focus is on sparsity-driven adaptive encoding models and comparing the methodology in state-of-the-art models found in the auditory literature. Furthermore, we outline the main signal processing pipeline for how to identify the attended sound source in a cocktail party environment from the raw electrophysiological data with all the necessary steps, complemented with the necessary MATLAB code and the relevant references for each step. Our main aim is to compare the methodology of the available methods, and provide numerical illustrations to some of them to get a feeling for their potential. A thorough performance comparison is outside the scope of this tutorial.

12.
Int J Artif Organs ; 41(5): 254-260, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29519192

RESUMEN

INTRODUCTION: The use of left ventricular assist device (LVAD) has grown rapidly. Adverse events do continue to occur. In recent years, analysis of LVAD sound recordings emerged as a means to monitor pump function and detect pump thrombosis. The aim of this study was to characterize the sounds from HeartMate II and to evaluate the use of handheld iOS devices for sound recordings. METHOD: Signal analysis of LVAD sound recordings, with dedicated recording equipment and iOS devices, was performed. Two LVADs running in mock loop circuits were compared to an implanted LVAD. Spectral analysis and parametric signal models were explored to quantify the sound and potentially detect changes in it. RESULTS: The sound recordings of two LVADs in individual mock loop circuits and a third one implanted in a patient appeared to be similar. Qualitatively, sound characteristics were preserved following changes in pump speed. Recordings using dedicated equipment showed that HeartMate II sound comprises low-frequency components corresponding to pump impeller rotation, as well as high-frequency components due to a pulse width modulation of the electric power to the pump. These different signal components interact and result in a complicated frequency spectrum. The iPhone and iPod recordings could not reproduce the sounds as well as the dedicated equipment. In particular, lower frequencies were affected by outside disturbances. DISCUSSION: This article outlines a systematic approach to LVAD sound analysis using signal processing methods to quantify and potentially detect changes, and describes some of the challenges, for example, with the use of inexpensive recording devices.


Asunto(s)
Insuficiencia Cardíaca/terapia , Corazón Auxiliar , Falla de Equipo , Humanos
13.
Struct Dyn ; 4(4): 044011, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28396880

RESUMEN

The use of low temperature thermal detectors for avoiding Darwin-Bragg losses in lab-based ultrafast experiments has begun. An outline of the background of this new development is offered, showing the relevant history and initiative taken by this work.

14.
Ecol Evol ; 6(19): 6930-6942, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-28725370

RESUMEN

Migratory songbirds carry an inherited capacity to migrate several thousand kilometers each year crossing continental landmasses and barriers between distant breeding sites and wintering areas. How individual songbirds manage with extreme precision to find their way is still largely unknown. The functional characteristics of biological compasses used by songbird migrants has mainly been investigated by recording the birds directed migratory activity in circular cages, so-called Emlen funnels. This method is 50 years old and has not received major updates over the past decades. The aim of this work was to compare the results from newly developed digital methods with the established manual methods to evaluate songbird migratory activity and orientation in circular cages.We performed orientation experiments using the European robin (Erithacus rubecula) using modified Emlen funnels equipped with thermal paper and simultaneously recorded the songbird movements from above. We evaluated and compared the results obtained with five different methods. Two methods have been commonly used in songbirds' orientation experiments; the other three methods were developed for this study and were based either on evaluation of the thermal paper using automated image analysis, or on the analysis of videos recorded during the experiment.The methods used to evaluate scratches produced by the claws of birds on the thermal papers presented some differences compared with the video analyses. These differences were caused mainly by differences in scatter, as any movement of the bird along the sloping walls of the funnel was recorded on the thermal paper, whereas video evaluations allowed us to detect single takeoff attempts by the birds and to consider only this behavior in the orientation analyses. Using computer vision, we were also able to identify and separately evaluate different behaviors that were impossible to record by the thermal paper.The traditional Emlen funnel is still the most used method to investigate compass orientation in songbirds under controlled conditions. However, new numerical image analysis techniques provide a much higher level of detail of songbirds' migratory behavior and will provide an increasing number of possibilities to evaluate and quantify specific behaviors as new algorithms will be developed.

15.
IEEE Trans Neural Syst Rehabil Eng ; 23(5): 796-806, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25222952

RESUMEN

Tracking human body motions using inertial sensors has become a well-accepted method in ambulatory applications since the subject is not confined to a lab-bounded volume. However, a major drawback is the inability to estimate relative body positions over time because inertial sensor information only allows position tracking through strapdown integration, but does not provide any information about relative positions. In addition, strapdown integration inherently results in drift of the estimated position over time. We propose a novel method in which a permanent magnet combined with 3-D magnetometers and 3-D inertial sensors are used to estimate the global trunk orientation and relative pose of the hand with respect to the trunk. An Extended Kalman Filter is presented to fuse estimates obtained from inertial sensors with magnetic updates such that the position and orientation between the human hand and trunk as well as the global trunk orientation can be estimated robustly. This has been demonstrated in multiple experiments in which various hand tasks were performed. The most complex task in which simultaneous movements of both trunk and hand were performed resulted in an average rms position difference with an optical reference system of 19.7±2.2 mm whereas the relative trunk-hand and global trunk orientation error was 2.3±0.9 and 8.6±8.7 deg respectively.


Asunto(s)
Acelerometría/instrumentación , Gestos , Mano/fisiología , Magnetometría/instrumentación , Monitoreo Ambulatorio/instrumentación , Postura/fisiología , Algoritmos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Imanes , Modelos Biológicos , Modelos Estadísticos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Integración de Sistemas
16.
IEEE Trans Image Process ; 15(11): 3400-8, 2006 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17076399

RESUMEN

We propose a ground target recognition method based on 3-D laser radar data. The method handles general 3-D scattered data. It is based on the fact that man-made objects of complex shape can be decomposed to a set of rectangles. The ground target recognition method consists of four steps; 3-D size and orientation estimation, target segmentation into parts of approximately rectangular shape, identification of segments that represent the target's functional/main parts, and target matching with CAD models. The core in this approach is rectangle estimation. The performance of the rectangle estimation method is evaluated statistically using Monte Carlo simulations. A case study on tank recognition is shown, where 3-D data from four fundamentally different types of laser radar systems are used. Although the approach is tested on rather few examples, we believe that the approach is promising.


Asunto(s)
Algoritmos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Rayos Láser , Reconocimiento de Normas Patrones Automatizadas/métodos , Radar , Inteligencia Artificial , Almacenamiento y Recuperación de la Información/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...