Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
2.
J Interv Card Electrophysiol ; 66(2): 417-425, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35962151

RESUMEN

BACKGROUND: The 12-month follow-up (F/U) efficacy of CBA PVI performed at community hospitals for treatment of symptomatic paroxysmal and persistent atrial fibrillation (AF) is unknown. This study determined the 12-month efficacy of pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) performed at community hospitals with limited annual case numbers. METHODS: This registry study included 983 consecutive patients (pts) from 19 hospitals, each with an annual procedural volume of < 100 PVI procedures/year. Pts underwent CBA PVI for paroxysmal AF (n = 520), persistent AF (n = 423), or redo PVI (n = 40). The primary endpoint was frequency of documented recurrent AF, the occurrence of atrial flutter or tachycardia following a 90-day period after the index ablation and up to 12 months. The frequency of repeat ablation was determined. RESULTS: Isolation of all PVs was documented in 98% of pts at the end of the procedure. Twelve-month F/U data could be obtained in 916 pts. A 24-h ECG registration was performed in 641 pts (70.0%); in 107 pts (16.7%) of them, recurrent AF was documented. The primary endpoint was met in 193 F/U pts (21.1%). It occurred in 80/486 F/U pts with paroxysmal AF (16.4%), and in 107/390 F/U pts with persistent AF (27.4%). Redo PVI was performed in 71 pts (7.8%), and atrial flutter ablation was performed in 12 pts (1.4%). CONCLUSIONS: CBA PVI for paroxysmal or persistent AF can be performed at community hospitals with adequate rates of 12-month symptom freedom and arrhythmia recurrence. The study was registered at the German register of clinical studies (DRKS00016504).


Asunto(s)
Fibrilación Atrial , Aleteo Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/cirugía , Hospitales Comunitarios , Aleteo Atrial/cirugía , Resultado del Tratamiento , Criocirugía/métodos , Venas Pulmonares/cirugía , Ablación por Catéter/métodos , Recurrencia
3.
Europace ; 23(11): 1744-1750, 2021 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-34374746

RESUMEN

AIMS: Pulmonary vein isolation (PVI) using cryoballoon ablation (CBA) is an established procedure for treating symptomatic paroxysmal and persistent atrial fibrillation (AF). The safety and efficacy of PVI performed at community hospitals are unknown. We aimed to determine the safety and acute efficacy of PVI using CBA performed at community hospitals with limited annual case numbers. METHODS AND RESULTS: This registry study included 1004 consecutive patients who had PVI performed for symptomatic paroxysmal (n = 563) or persistent AF (n = 441) from January 2019 to September 2020 at 20 hospitals. Each hospital performed fewer than 100 CBA-PVI procedures/year according to local standards. Procedural data, efficacy, and complication rates were determined. The mean number of CBA procedures performed/year at each centre was 59 ± 25. The average procedure time was 90.1 ± 31.6 min and the average fluoroscopy time was 19.2 ± 11.4 min. Isolation of all pulmonary veins was documented in 97.9% of patients. The most frequent reason for not achieving complete isolation was development of phrenic nerve palsy. No hospital deaths were observed. Two patients (0.2%) suffered a clinical stroke. Pericardial effusion occurred in six patients (0.6%), two of whom (0.2%) required pericardial drainage. Vascular complications occurred in 24 patients (2.4%), two of whom (0.2%) required vascular surgery. Phrenic nerve palsy occurred in 48 patients (4.8%) and persisted up to hospital discharge in six patients (0.6%). CONCLUSION: Pulmonary vein isolation procedures for paroxysmal or persistent AF using CBA can be performed at community hospitals with high acute efficacy and low complication rates.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Hospitales Comunitarios , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
4.
Indian Pacing Electrophysiol J ; 21(4): 209-218, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33866018

RESUMEN

BACKGROUND: In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), intracardiac impedance measured by dedicated CRT-D software may be used to monitor hemodynamic changes. We investigated the relationship of hemodynamic parameters assessed by intracardiac impedance and by echocardiography in a controlled clinical setting. METHODS: The study enrolled 68 patients (mean age, 66 ± 9 years; 74% males) at 12 investigational sites. The patients had an indication for CRT-D implantation, New York Heart Association class II/III symptoms, left ventricular ejection fraction 15%-35%, and a QRS duration ≥150 ms. Two months after a CRT-D implantation, hemodynamic changes were provoked by overdrive pacing. Intracardiac impedance was recorded at rest and at four pacing rates ranging from 10 to 40 beats/min above the resting rate. In parallel, echocardiography measurements were performed. We hypothesized that a mean intra-individual correlation coefficient (rmean) between stroke impedance (difference between end-systolic and end-diastolic intracardiac impedance) measured by CRT-D and the aortic velocity time integral (i.e., stroke volume) determined by echocardiography would be significantly larger than 0.65. RESULTS: The hypothesis was evaluated in 40 patients with complete data sets. The rmean was 0.797, with a lower confidence interval bound of 0.709. The study hypothesis was met (p = 0.007). A stepwise reduction of stroke impedance and stroke volume was observed with increasing heart rate. CONCLUSIONS: Intracardiac impedance measured by implanted CRT-Ds correlated well with the aortic velocity time integral (stroke volume) determined by echocardiography. The impedance measurements bear potential and are readily available technically, not requiring implantation of additional material beyond standard CRT-D system.

5.
Pacing Clin Electrophysiol ; 43(12): 1491-1494, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33085093

RESUMEN

Six months after subcutaneous implantable cardioverter defibrillator (S-ICD) implantation a 26-year-old Brugada patient presented because of a beeping tone emitted by his device. Chest X-ray displayed two functionless transvenous shock leads and the S-ICD system with a lead fracture. During lead revision procedure, extensive preparation of the lead from unexpectedly firm surrounding fibrous tissue encapsulating the lead was necessary before it could be removed, and a new shock lead could be implanted. This is the first report of an S-ICD lead exchange due to very early lead fracture and unexpectedly severe fibrous tissue hampering surgical lead extraction.


Asunto(s)
Síndrome de Brugada/terapia , Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Falla de Equipo , Adulto , Síndrome de Brugada/fisiopatología , Remoción de Dispositivos , Humanos , Masculino
6.
J Cardiovasc Electrophysiol ; 31(11): 3056-3060, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32841460

RESUMEN

The remede system is a novel fully implantable transvenous phrenic nerve stimulation (TPNS) device developed to treat central sleep apnea. No information is published on how to explant or replace its leads. An eighty-one year-old had a fractured lead and we removed it over a wire. However, unbreachable resistances occurred with a new lead deployed over the enclosed wire and interventional endovascular techniques were performed to reimplant a new fully functioning system. This first report demonstrates TPNS lead exchange is possible but can be challenging. Interventional maneuvers and techniques, including balloon angioplasty, can facilitate this procedure.


Asunto(s)
Terapia por Estimulación Eléctrica , Apnea Central del Sueño , Anciano de 80 o más Años , Humanos , Nervio Frénico , Apnea Central del Sueño/terapia , Resultado del Tratamiento
7.
J Interv Card Electrophysiol ; 58(2): 169-175, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31168672

RESUMEN

PURPOSE: The concern of higher radiation exposure during cryoballoon ablation (CBA) compared with radiofrequency ablation for atrial fibrillation (AF) was raised before. Previously, we compared CBA plus intracardiac echocardiography (ICE) to our former standard approach without ICE. A substantial reduction of radiation exposure without compromising safety or outcome was observed. We now investigate if at all and possibly to which amount radiation reduction can be achieved with growing experience. METHODS: We retrospectively analysed procedure time, dose area product (DAP), fluoroscopy time (FT) and contrast media (CM) use for all patients receiving CBA between 2013 and 2017 for AF. RESULTS: In 1131 procedures, procedure time decreased significantly between 2013 and 2017 (2013 111 ± 26 min, 2017 99 ± 25 min, p = 0.005). DAP halved between 2013 and 2014 without further significant decline (2013 1428 ± 1276 cGycm2, 2014 725 ± 551 cGycm2, p < 0.001). FT demonstrated a constant decrease from 2013 to 2017 (2013 11.7 ± 5.5 min, 2017 5.1 ± 3.5 min, p < 0.001). CM use did not show a significant reduction comparing 2013 to 2017 (2013 62 ± 19 ml, 2017 59 ± 18 ml, 2013/2017 p = 0.584). CONCLUSION: Given the imminent negative effects of radiation, every effort should be undertaken for its reduction. Feasible protocols can be kept simple by technical changes as reducing frame rates and basic radiation reduction strategies such as collimation, but ICE might add additional benefit. With growing experience and awareness of radioprotection, DAP and FT as low as or lower than in radiofrequency ablations seem possible.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Exposición a la Radiación , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Medios de Contraste , Ecocardiografía , Fluoroscopía , Humanos , Venas Pulmonares/cirugía , Exposición a la Radiación/prevención & control , Estudios Retrospectivos , Resultado del Tratamiento
8.
Sleep Breath ; 24(3): 905-912, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31407159

RESUMEN

PURPOSE: Central sleep apnea (CSA) is a highly common comorbidity in heart failure (HF) patients and is known to deteriorate quality of life and prognosis. Effective treatment options are scarce. Transvenous phrenic nerve stimulation (PNS) has been shown to be effective and safe in CSA treatment in HF. However, lead implantation may be difficult or fail due to anatomical or technical challenges. We report novel and innovative approaches applying different interventional techniques to enhance PNS implantation success, allowing otherwise missing CSA treatment. METHODS: Twenty-seven consecutive HF patients (86% male, mean age: 69 ± 11 years; reduced left ventricular ejection fraction in 16 patients (57%)) were included in this study who were unable to tolerate or had contraindications for mask-based therapy. We evaluated PNS total implantation success, procedural characteristics, and feasibility and success rates of intravascular interventions to facilitate PNS lead implantation in otherwise ineffective procedures. RESULTS: Seven lead implantation attempts (24%) required additional intravascular interventional action to facilitate successful implantation, mainly consisting of balloon angioplasties to allow optimal PNS lead placement. Two procedures remained unsuccessful and two patients underwent a second procedure due to stimulation side effects and lead fracture respectively. All over, no complications resulted from application of interventional techniques to achieve a 93% implantation success rate. CONCLUSION: Transvenous PNS lead placement for CSA treatment can be difficult and challenging. However, interventional intravascular techniques markedly increase implantation success and thereby allow application of this therapy for effective CSA treatment in most patients without additional complications.


Asunto(s)
Terapia por Estimulación Eléctrica/métodos , Insuficiencia Cardíaca/complicaciones , Nervio Frénico/fisiopatología , Apnea Central del Sueño/terapia , Anciano , Nivel de Alerta/fisiología , Femenino , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Polisomnografía , Estudios Prospectivos , Apnea Central del Sueño/complicaciones , Volumen Sistólico , Resultado del Tratamiento
9.
Heart Rhythm ; 17(4): 600-606, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31841715

RESUMEN

BACKGROUND: Cryoballoon ablation (CBA) is gaining increasing acceptance in the treatment of persistent (per) atrial fibrillation (AF). The cardiac autonomic nervous system plays a pivotal role in the regulation of AF. OBJECTIVE: We evaluated the impact of vagal reactions (VRs), as a surrogate marker for autonomic nervous system modulation, on the outcome of CBA in patients (pts) with perAF. METHODS: A total of 250 consecutive pts (mean age 63.9 ± 10.0 years; 175 pts, 70% male) undergoing primary second-generation CBA for perAF were studied. VRs were defined as bradycardia <40 beats/min, asystole, or higher-degree atrioventricular block. Follow-up visits at 3, 6, and 12 months included 7-day Holter electrocardiograms. RESULTS: VRs were recorded in 61 pts (24%). These pts showed a significantly reduced recurrence rate of AF (5%) than did those without VRs (log-rank, P < .01). Univariate Cox regression analyses confirmed VRs as a strong predictor of AF-free survival (hazard ratio [HR] 0.10; P < .01). Female sex (HR 1.71; P = .02), preprocedural tachycardia (HR 1.01; P = .01), and AF (HR 1.75; P = .01) before CBA at admission were revealed as predictors of AF recurrence. Multivariate regression model calculation solely identified VRs (HR 0.11; 95% confidence interval 0.03-0.34; P < .01) and male sex (HR 0.57; 95% confidence interval 0.36-0.89; P = .01) as independent predictors of AF-free survival. CONCLUSION: VR is an independent predictor of AF-free survival after CBA for perAF.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Electrocardiografía , Sistema de Conducción Cardíaco/fisiología , Venas Pulmonares/cirugía , Nervio Vago/fisiopatología , Fibrilación Atrial/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Factores de Tiempo , Resultado del Tratamiento
10.
J Interv Card Electrophysiol ; 54(3): 231-236, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30361790

RESUMEN

PURPOSE: Hemoptysis and pulmonary hemorrhage are rarely described as complications of cryoballoon ablation for pulmonary vein isolation (CB PVI). This study evaluated a large cohort to determine the frequency and risk factors for manifestation of these complications and assess the clinical relevance of hemoptysis after CB PVI. METHODS: Seven hundred fifteen consecutive patients (351 female) from a single-center database were evaluated to identify those who developed hemoptysis after CB PVI. RESULTS: A total of 31 patients with hemoptysis (4.3%; 2 female, age 60.5 ± 11.5 years) were matched with a control group (n = 31). Hemoptysis developed within 72 h after CB PVI. Cases versus controls had significantly lower ablation temperatures in the right inferior pulmonary vein (PV) (- 56.2 ± 26.6 vs - 49.1 ± 13.2 °C; p = 0.004) and left inferior PV (- 56.4 ± 11.9 vs - 47.2 ± 7.6 °C; p = 0.001). A trend to lower temperatures not reaching the level of significance was also found for the superior PV. All other procedural parameters were not significantly different between cases and controls. Although pre-procedural hemoglobin levels were comparable, post-procedural hemoglobin was lower in cases versus controls (12.9 ± 1.6 vs 13.7 ± 1.5 g/dL; p < 0.05). Twenty-six patients presenting with hemoptysis underwent chest CT scan, which showed perivenous infiltration at either the right (n = 23) or left inferior PV (n = 2) or no infiltrate (n = 1). No negative long-term effects were reported after 3, 6, and 12 months' follow-up. CONCLUSIONS: Post-procedural hemoptysis after CB PVI is a relatively frequent finding and was associated with low freezing temperatures and pulmonary tissue infiltration predominantly located at the right inferior PV. Hemoptysis resolved without long-term sequelae.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Hemoptisis/etiología , Complicaciones Posoperatorias/etiología , Venas Pulmonares/cirugía , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
11.
Europace ; 20(6): 971-978, 2018 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-28419217

RESUMEN

Aims: Dual coil (DC) electrodes are preferred to single coil (SC) electrodes because of an assumed higher shock efficacy. However, DC-electrodes may be associated with an increased difficulty and risk of lead extraction. We aimed to compare SC- and DC-electrodes with respect to the first shock efficacy (FSE) after implantable cardioverter defibrillator (ICD) implantation. Methods and results: One thousand and seventy-seven patients of the NORDIC ICD trial were randomly assigned to first time ICD implantation with or without defibrillation (DF) testing. The electrode configuration was determined before randomization. One thousand and sixty-seven patients eventually received an ICD, 516 (48.4%) with a SC- and 551 (51.6%) with a DC-electrode. DC-electrodes were preferentially selected in older patients, renal failure, atrial fibrillation, dual chamber, Cardiac Resynchronization Therapy (CRT) devices, angiotensin-converting-enzyme (ACE) inhibitors/angiotensin (AT) receptor blockers and without Sotalol. However, the preference of the investigational site was dominant over clinical parameters. The DF energy at the final electrode position was higher in SC-electrodes (adjusted difference +1.15 J; P = 0.005; only patients tested). Less patients with DC-electrodes required intra-operative system reconfiguration (adjusted difference -3.9; P = 0.046; only patients tested). Using mixed logistic regression, the FSE was 92.6% in SC- and 97.8% in DC-electrodes (adjusted odds ratio 4.3 (95% confidence interval [1.9, 9.8]; P < 0.001)). Conclusion: Dual coil-electrode selection mainly depends on the preference of the investigational site and seems to be preferred in older patients, renal failure, atrial fibrillation, dual chamber, and CRT devices. Patients with DC-electrodes required less intraoperative system reconfigurations. Dual coil-electrodes provided a substantially higher FSE during follow-up. Mortality rates were not significantly different in patients with DC- and SC-electrodes.


Asunto(s)
Arritmias Cardíacas/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Anciano , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Desfibriladores Implantables/efectos adversos , Desfibriladores Implantables/clasificación , Cardioversión Eléctrica/métodos , Diseño de Equipo/métodos , Femenino , Humanos , Cuidados Intraoperatorios/métodos , Masculino , Persona de Mediana Edad , Selección de Paciente , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
12.
Clin Res Cardiol ; 107(2): 182-192, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29075979

RESUMEN

BACKGROUND: Catheter ablation is an established treatment option for patients with symptomatic atrial fibrillation (AF). The cornerstone of AF ablation is pulmonary vein isolation (PVI). The second-generation cryoballoon (2G-CB) has shown non-inferiority to radiofrequency (RF) ablation in paroxysmal AF in several trials. Growing evidence suggests that 2G-CB is also effective in patients with persistent AF (perAF). The aim of this study was to summarize and analyze available data on safety and mid-term (≥ 12 months) efficacy of PVI using 2G-CB in patients with perAF. METHODS: We did a search in PubMed, Web of Science, Cochrane Library, and clinicaltrials.gov in December 2016 for studies of 2G-CB ablation for perAF. Studies reporting clinical success rates at a follow-up (FU) of ≥ 12 months were included. Success was defined as freedom from any atrial arrhythmia lasting > 30 s after an initial blanking period of 3 months. Acute success and complication rates were also assessed. Data were analyzed applying random-effects model. RESULTS: A total of 917 patients from 11 studies meeting study inclusion criteria were analyzed. After a mean FU of 16.7 ± 3.0 months, 68.9% were free from recurrences [95% confidence interval (CI) 63.4-74.7%]. Overall acute success rate was 99.7% (95% CI 99.2-100%). Complications occurred in 5.5% (95% CI 2.4-9.6%). Vascular access complications were the most frequent 3.3% (95% CI 1.5-5.6%). The rate of phrenic nerve palsy/injury was 2.09% (95% CI 0.8-3.9%). No death, stroke or myocardial infarction was reported. CONCLUSION: The 2G-CB seems to be safe and effective in the treatment of perAF in the mid-term.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Catéteres Cardíacos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Venas Pulmonares/fisiopatología , Recurrencia , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
13.
Sleep Med ; 37: 66-71, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28899542

RESUMEN

OBJECTIVE/BACKGROUND: Sleep-disordered breathing (SDB) is common in patients with atrial fibrillation (Afib). Although a high proportion of respiratory events are hypopneas, previous studies have only used apneas to differentiate obstructive (OSA) from central (CSA) sleep apnea. This study investigated the impact of using apneas and hypopneas versus apneas only to define the predominant type of SDB in Afib patients with preserved ejection fraction. PATIENTS/METHODS: This retrospective analysis was based on high-quality cardiorespiratory polygraphy (PG) recordings (07/2007-03/2016) that were re-analyzed using 2012 American Academy of Sleep Medicine criteria, with differentiation of apneas and hypopneas as obstructive or central. Classification of predominant (>50% of events) OSA and CSA was defined based on apneas only (OSAAI and CSAAI) or apneas and hypopneas (OSAAHI and CSAAHI). SDB was defined as an apnea-hypopnea index ≥5/h. RESULTS: A total of 211 patients were included (146 male, age 68.7 ± 8.5 y). Hypopneas accounted for >50% of all respiratory events. Based on apneas only, 46% of patients had predominant OSA and 44% had predominant CSA. Based on apneas and hypopneas, the proportion of patients with OSA was higher (56%) and that with CSA was lower (36%). In the subgroup of patients with moderate to severe SDB (AHI ≥ 15/h), the proportion with predominant CSA was 55.2% based on apneas only versus 42.1% with apneas and hypopneas. CONCLUSIONS: In hospitalized patients with Afib and SDB, use of apneas and hypopneas versus apneas alone had an important influence on the proportion of patients classified as having predominant OSA or CSA.


Asunto(s)
Fibrilación Atrial/complicaciones , Apnea Central del Sueño/clasificación , Apnea Central del Sueño/complicaciones , Apnea Obstructiva del Sueño/clasificación , Apnea Obstructiva del Sueño/complicaciones , Anciano , Análisis de Varianza , Fibrilación Atrial/clasificación , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Masculino , Estudios Retrospectivos , Apnea Central del Sueño/fisiopatología , Apnea Obstructiva del Sueño/fisiopatología
14.
Europace ; 19(4): 588-595, 2017 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-28431058

RESUMEN

AIMS: The aim of this study was to evaluate any benefits to the number of viable pacing vectors and maximal spatial coverage with quadripolar left ventricular (LV) leads when compared with tripolar and bipolar equivalents in patients receiving cardiac resynchronization therapy (CRT). METHODS AND RESULTS: A meta-analysis of five previously published clinical trials involving the Quartet™ LV lead (St Jude Medical, St Paul, MN, USA) was performed to evaluate the number of viable pacing vectors defined as capture thresholds ≤2.5 V and no phrenic nerve stimulation and maximal spatial coverage of viable vectors in CRT patients at pre-discharge (n = 370) and first follow-up (n = 355). Bipolar and tripolar lead configurations were modelled by systematic elimination of two and one electrode(s), respectively, from the Quartet lead. The Quartet lead with its four pacing electrodes exhibited the greatest number of pacing vectors per patient when compared with the best bipolar and the best tripolar modelled equivalents. Similarly, the Quartet lead provided the highest spatial coverage in terms of the distance between two furthest viable pacing cathodes when compared with the best bipolar and the best tripolar configurations (P < 0.05). Among the three modelled bipolar configurations, the lead configuration with the two most distal electrodes resulted in the highest number of viable pacing vectors. Among the four modelled tripolar configurations, elimination of the second proximal electrode (M3) resulted in the highest number of viable pacing options per patient. There were no significant differences observed between pre-discharge and first follow-up analyses. CONCLUSION: The Quartet lead with its four electrodes and the capability to pace from four anatomical locations provided the highest number of viable pacing vectors at pre-discharge and first follow-up visits, providing more flexibility in device programming and enabling continuation of CRT in more patients when compared with bipolar and tripolar equivalents.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Electrodos Implantados/estadística & datos numéricos , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/prevención & control , Marcapaso Artificial/estadística & datos numéricos , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/estadística & datos numéricos , Anciano , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Ventrículos Cardíacos , Humanos , Masculino , Prevalencia , Resultado del Tratamiento
15.
Pacing Clin Electrophysiol ; 40(5): 498-503, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28211952

RESUMEN

BACKGROUND: Sleep-disordered breathing (SDB) and Cheyne-Stokes respiration (CSR) are associated with shorter survival in patients with heart failure. A novel treatment method for this patient group is unilateral phrenic nerve stimulation by the remede® system (Respicardia Inc., Minnetonka, MN, USA), a transvenously implantable neurostimulation device, which has recently been studied in a large randomized, controlled trial. Previous literature has shown efficacy and safety of the treatment with this first-generation device, but hardly any data are available on long-term clinical parameters, the remede® device's battery lifetime, device exchangeability, lead position stability, surgical accessibility, and manageability. METHODS: We performed remede® device replacements in consecutive patients for battery depletion, and documented clinical parameters, longevity, operation procedure, complications, and difficulties. RESULTS: All patients were on neurostimulation treatment by phrenic nerve neurostimulation when device replacement became necessary. Apnea-hypopnea index (from 45 ± 4/h to 9 ± 4/h), oxygen-desaturation index (from 35 ± 7/h to 7 ± 6/h), and time spent with oxygen saturation of <90% (T < 90% from 5 ± 7% to 0 ± 0%) were improved and improvements remained constant throughout the 4-year follow-up. Mean battery life was 4.2 ± 0.2 years and mean replacement procedure time was 25 ± 5.1 minutes. Apart from conventional X-ray documentation of stable lead positions in a long-term setting, no radiation or contrast dye usage was needed and no major complications occurred. In addition, clinical exercise capacity and sleepiness symptoms improved. CONCLUSIONS: Novel remede® device shows sustained therapy efficacy and safety in terms of stable lead positions over 4 years. Long-term phrenic nerve neurostimulation therapy for central SDB/CSR appears feasible in a clinical routine setting.


Asunto(s)
Respiración de Cheyne-Stokes/diagnóstico , Respiración de Cheyne-Stokes/terapia , Terapia por Estimulación Eléctrica/instrumentación , Neuroestimuladores Implantables , Nervio Frénico , Apnea Central del Sueño/diagnóstico , Apnea Central del Sueño/terapia , Anciano , Terapia por Estimulación Eléctrica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Estudios Longitudinales , Masculino , Resultado del Tratamiento
16.
Europace ; 19(6): 947-953, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-27256413

RESUMEN

AIMS: The population treated with cryoballoon (CB) ablation is relatively young, and radiation protection is of major importance. We aimed to demonstrate that radiation exposure can be markedly reduced by intracardiac echocardiography (ICE) and optimized settings of the X-ray system. METHODS AND RESULTS: We analysed 100 patients undergoing CB pulmonary vein isolation (PVI) for treatment of paroxysmal atrial fibrillation. In 50 consecutive patients (25 male, 59 ± 13 years; Group 1), we used ICE, skipped PV angiography prior to CB inflation, and avoided fluoroscopy whenever possible. Furthermore, we reduced the frame rate, minimized distance between patient and detector, and consequently applied collimation. These patients were compared with 50 similar preceding patients in Group 2 (29 male, 61 ± 12 years). Total fluoroscopy time was reduced from 18 ± 6 min in Group 2 to 12 ± 5 min in Group 1 (P < 0.001). Moreover, the dose area product was significantly lower (1555 ± 1219 vs. 4935 ± 2094 cGycm2, P < 0.001), total freezing time was significantly shortened (1855 ± 399 vs. 2121 ± 756 s, P = 0.031), and contrast media use was significantly reduced (66 ± 25 vs. 109 ± 27 mL, P < 0.001). At the same time, total procedure duration and complication rates did not differ significantly between both groups. After a 12 months follow-up, a similar percentage of patients was free from recurrences (74% in Group 1 vs. 78% in Group 2, P = 0.640). CONCLUSION: Radiation exposure in CB PVI can be markedly reduced without prolonging procedure times, affecting the outcome or complication rates. Moreover, ICE seems to shorten total freezing time.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía , Ecocardiografía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Dosis de Radiación , Exposición a la Radiación/prevención & control , Radiografía Intervencional , Anciano , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Femenino , Fluoroscopía , Alemania , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Venas Pulmonares/fisiopatología , Exposición a la Radiación/efectos adversos , Radiografía Intervencional/efectos adversos , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
17.
JACC Heart Fail ; 3(5): 360-369, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25770408

RESUMEN

OBJECTIVES: The aim of this study was to evaluate chronic, transvenous, unilateral phrenic nerve stimulation to treat central sleep apnea (CSA) in a prospective, multicenter, nonrandomized study. BACKGROUND: CSA occurs predominantly in patients with heart failure and increases the risk for morbidity and mortality. Established therapies for CSA are lacking, and those available are limited by poor patient adherence. METHODS: Fifty-seven patients with CSA underwent baseline polysomnography followed by transvenous phrenic nerve stimulation system implantation and follow-up. Feasibility was assessed by implantation success rate and therapy delivery. Safety was evaluated by monitoring of device- and procedure-related adverse events. Efficacy was evaluated by changes in the apnea-hypopnea index at 3 months. Quality of life at 6 months was evaluated using a sleepiness questionnaire, patient global assessment, and, in patients with heart failure at baseline, the Minnesota Living With Heart Failure Questionnaire. RESULTS: The study met its primary end point, demonstrating a 55% reduction in apnea-hypopnea index from baseline to 3 months (49.5 ± 14.6 episodes/h vs. 22.4 ± 13.6 episodes/h of sleep; p < 0.0001; 95% confidence interval for change: -32.3 to -21.9). Central apnea index, oxygenation, and arousals significantly improved. Favorable effects on quality of life and sleepiness were noted. In patients with heart failure, the Minnesota Living With Heart Failure Questionnaire score significantly improved. Device- or procedure-related serious adverse events occurred in 26% of patients through 6 months post therapy initiation, predominantly due to lead repositioning early in the study. Therapy was well tolerated. Efficacy was maintained at 6 months. CONCLUSIONS: Transvenous, unilateral phrenic nerve stimulation appears safe and effective for treating CSA. These findings should be confirmed in a prospective, randomized, controlled trial. (Chronic Evaluation of Respicardia Therapy; NCT01124370).


Asunto(s)
Calidad de Vida , Apnea Central del Sueño/terapia , Sueño/fisiología , Estimulación Eléctrica Transcutánea del Nervio/métodos , Anciano , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Nervio Frénico , Polisomnografía , Estudios Prospectivos , Apnea Central del Sueño/fisiopatología , Resultado del Tratamiento
18.
Eur J Heart Fail ; 16(12): 1331-6, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25371320

RESUMEN

AIMS: The true incidence of life-threatening ventricular tachyarrhythmic events and the risk of sudden cardiac death in the early stage of peripartum cardiomyopathy (PPCM) are still unknown. We aimed to assess the usefulness of the wearable cardioverter/defibrillator (WCD) to bridge a potential risk for life-threatening arrhythmic events in patients with early PPCM, severely reduced left ventricular ejection fraction (LVEF) and symptoms of heart failure. METHODS AND RESULTS: Twelve consecutively admitted women with PPCM were included in this single-centre, prospective observational study between September 2012 and September 2013. Patients with LVEF ≤35% were considered to use the WCD for 3 months or even 6 months when considered necessary for LVEF recovery. Nine of the 12 women had a severely reduced LVEF (mean 18.3%) at the time of study enrollment; seven women received a WCD, while two patients refused to wear a WCD. During a median WCD follow-up of 81 days (range 25-345 days), we observed a total of four events of ventricular fibrillation with appropriate and successful WCD shocks in three of the seven women receiving a WCD. No syncope or sudden arrhythmic deaths occurred in women not using the WCD during a median follow-up of 12 months (range 5-15 months). All women showed impressive improvement of LVEF during follow-up. CONCLUSION: PPCM patients with severely reduced LVEF have an elevated risk for ventricular tachyarrhythmias early after diagnosis. Therefore, use of the WCD should be considered in all women with early-stage PPCM and severely reduced LVEF during the first 6 months after initiation of heart failure therapy.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Desfibriladores Implantables , Complicaciones Cardiovasculares del Embarazo , Disfunción Ventricular Izquierda/complicaciones , Fibrilación Ventricular/etiología , Adulto , Cardiomiopatía Dilatada/diagnóstico por imagen , Cardiomiopatía Dilatada/fisiopatología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/métodos , Femenino , Humanos , Periodo Periparto , Embarazo , Estudios Prospectivos , Volumen Sistólico/fisiología , Ultrasonografía , Disfunción Ventricular Izquierda/fisiopatología , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia
19.
Herzschrittmacherther Elektrophysiol ; 25(3): 198-205, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25070930

RESUMEN

PURPOSE: Supraventricular tachyarrhythmias are a major cause of inappropriate defibrillator shocks. Sleep-disordered breathing (SDB) is a known risk factor for atrial fibrillation (AF). We hypothesized that Cheyne-Stokes respiration (CSA) and obstructive sleep apnea (OSA) have an impact on inappropriate defibrillator discharges in patients witch chronic heart failure (CHF) and cardiac resynchronization therapy with defibrillator (CRT-D). METHODS: In this study, 172 patients with CHF (LVEF ≤ 45 %, NYHA-class ≥ 2) and CRT-D underwent overnight polygraphy; 54 had no SDB (apnea-hypopnea index < 5/h), 59 had OSA, and 59 had CSA. During follow-up (36 months), inappropriate defibrillator shocks were documented. RESULTS: In all, 17 patients had inappropriate defibrillator shocks (9.9 %; eight oversensing due to lead fractures, five caused by atrial fibrillation, four because of sinus tachycardia). Mean event-free survival time was 33.5 ± 1.2 months in the CSA group, 35.2 ± 0.7 months in the OSA group, and 32.1 ± 1.5 months in the no SDB group, respectively (CSA vs. no SDB p = 0.63; OSA vs. no SDB p = 0.31; CSA vs. OSA p = 0.45). Stepwise Cox proportional hazard regression analysis revealed an independent association for age (per year: hazard ratio 0.90, 95 % confidence interval 0.85-0.96, p < 0.001), but not for any kind of SDB. CONCLUSIONS: SDB was not associated with inappropriate defibrillator shocks. We assume this is due to the low incidenceand low proportion of inappropriate therapies in response to AF.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Traumatismos por Electricidad/mortalidad , Falla de Equipo/estadística & datos numéricos , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/prevención & control , Sistema de Registros , Síndromes de la Apnea del Sueño/mortalidad , Anciano , Causalidad , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Factores de Riesgo , Tasa de Supervivencia
20.
J Interv Card Electrophysiol ; 40(1): 75-80, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24626999

RESUMEN

INTRODUCTION: A quadripolar left ventricular (LV) pacing can deliver multipoint pacing (MPP). It is unknown if this confers improved cardiac function compared to conventional cardiac resynchronization therapy (CRT). METHODS AND RESULTS: We aimed to characterize changes in acute cardiac contractility and hemodynamics with multisite left ventricular "multipoint" pacing (MPP) in a prospective multicenter study in patients implanted with a CRT-defibrillator incorporating a quadripolar LV lead. The device was programmed to deliver MPP acutely pacing with eight configurations of varying timing delays. Global peak LV radial strain and LV outflow velocity time integral (LVOT VTI) were measured for conventional CRT and each MPP configuration. Out of the eight tested MPP configurations, the one that yielded the best echocardiographic measurement for each patient was defined as "optimal MPP". Forty CRT recipients had complete radial strain datasets suitable for analysis. Compared to conventional CRT, the mean peak radial strain was significantly higher for the optimal MPP configuration (18.3 ± 7.4 vs. 9.3 ± 5.3%, p < 0.001), and at least one MPP configuration was significantly superior (>20%) in 63% of patients. LVOT VTI data were collected in a subset of 13 patients. In these patients, mean VTI was significantly higher for optimal MPP compared to conventional CRT (13.5 ± 2.7 vs. 10.9 ± 3.3 cm, p < 0.01). CONCLUSION: MPP delivered via a quadripolar LV lead resulted in a significant improvement in acute cardiac contractility and hemodynamics compared to conventional CRT in the majority of patients studied. CLINICAL TRIAL REGISTRATION: Clinicaltrials.gov identifier NCT01044784.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Contracción Miocárdica , Anciano , Electrodos Implantados , Diseño de Equipo , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...