Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ann Occup Hyg ; 58(3): 340-54, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24371044

RESUMEN

An advanced design of a denuder impactor (DI) sampler has been developed for characterization of possible airborne isocyanate exposure in different particle size fractions. The sampler is equipped with 12 different parallel denuder tubes, 4 impaction stages with the cut-off values (d50) of: 9.5, 4, 2.5 and 1 µm, and an end filter that collects particles < 1 µm. All collecting parts were impregnated with di-n-butylamine DBA as the reagent in a mixture with acetic acid. The performance of the DI sampler was studied on a standard atmosphere containing gas and particulate isocyanates. The isocyanate atmosphere was generated by liquid permeation of 2,4-, 2,6-Toluene Diisocyanate (TDI), 1,6-Hexamethylene Diisocyanate (HDI) and Isophorone Diisocyanate (IPDI). 4,4'-Methylene Diphenyl Diisocyanate (MDI) particles were generated by heating of technical MDI and condensing the mixture of gas and particle-borne MDI in an atmosphere containing mixed salt particles. The study was performed in a 0.85 m3 environmental chamber with stainless steel walls. With the advancement of the DI sampler it is now possible to collect isocyanate particle samples for up to 320 min. The performance of the DI sampler is essentially unaffected by the humidity. The DI sampler and the ASSET EZ4-NCO sampler (Sigma-Aldrich/Supelco, Bellefonte, PA, USA) gave similar results. Sample losses within the DI sampler are low. In the environmental chamber it was observed that the particle distribution may be affected by the humidity and ageing. A scanning mobility particle sizer (SMPS) was used to separate a flow of selected fractions containing MDI particles from mixed MDI and salt particles. The particle-size distribution had a maximum at about 300 nm, but later in the environmental chamber 1 µm dominated. The distribution was very different as compared to with only NaCl or MDI present. The biological relevance for studying isocyanate nano particles is significant as these have the possibility to reach the lower airways where allergic reactions may occur. SMPS and isocyanate air sampling can be used for the investigation of isocyanate nano particles.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/métodos , Exposición por Inhalación/análisis , Isocianatos/análisis , Aerosoles/análisis , Monitoreo del Ambiente/instrumentación , Humanos , Humedad , Nanopartículas/análisis , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Tamaño de la Partícula
2.
Ann Occup Hyg ; 58(1): 28-49, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23960047

RESUMEN

The performance of a dry sampler, with an impregnated denuder in series with a glass fibre filter, using di-n-butylamine (DBA) for airborne isocyanates (200ml min(-1)) is investigated and compared with an impinger flask with a glass fibre filter in series (1 l min(-1)). An exposure chamber containing 1,6-hexamethylene diisocyanate (HDI), isophorone diisocyanate (IPDI), and 2,4- and 2,6-toluene diisocyanate (TDI) in the concentration range of 5-205 µg m(-3) [0.7-33 p.p.b.; relative humidity (RH) 50%], generated by gas- and liquid-phase permeation, was used for the investigation. The precision for the dry sampling for five series with eight samplers were in the range of 2.0-6.1% with an average of 3.8%. During 120-min sampling (n = 4), no breakthrough was observed when analysing samplers in series. Sixty-four exposed samplers were analysed after storage for 0, 7, 14, and 21 days. No breakdown of isocyanate derivatives was observed. Twenty-eight samplers in groups of eight were collecting isocyanates during 0.5-32h. Virtually linear relationships were obtained with regard to sampling time and collected isocyanates with correlation coefficients in the range of 0.998-0.999 with the intercept close to the origin. Pre- or post-exposure to ambient air did not affect the result. Dry sampling (n = 48) with impinger-filter sampling (n = 48) of thermal decomposition product of polyurethane polymers, at RH 20, 40, 60, and 90%, was compared for 11 isocyanate compounds. The ratio between the different isocyanates collected with dry samplers and impinger-filter samplers was in the range of 0.80-1.14 for RH = 20%, 0.8-1.25 for RH = 40%, 0.76-1.4 for RH = 60%, and 0.72-3.7 for RH = 90%. Taking into account experimental errors, it seems clear that isocyanic acid DBA derivatives are found at higher levels in the dry samples compared with impinger-filter samplers at elevated humidity. The dry sampling using DBA as the reagent enables easy and robust sampling without the need of field extraction.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/métodos , Isocianatos/análisis , Aerosoles/análisis , Cromatografía Liquida , Monitoreo del Ambiente/instrumentación , Monitoreo del Ambiente/normas , Humanos , Exposición Profesional/análisis , Espectrometría de Masas en Tándem , Factores de Tiempo
3.
Ann Occup Hyg ; 54(4): 377-90, 2010 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-20215336

RESUMEN

In some industries, the temperature and the humidity will vary greatly between different work places, such as outdoor work in arctic or tropical climates. There is therefore a need to test respirator filters at conditions that simulate conditions that are relevant for the industries that they are used in. Filter cartridges were exposed to controlled atmospheres of varying isocyanate concentration, air humidity, and temperature in an exposure chamber. For isocyanic acid (ICA) and methyl isocyanate (MIC), the exposure concentrations were between 100 and 200 p.p.b., monitored using a proton transfer reaction mass spectrometer. ICA and MIC were generated by continuous thermal degradation of urea and dimethylurea. The breakthrough was studied by collecting air samples at the outlet of the filter cartridges using impinger flasks or dry samplers with di-n-butylamine as derivatization reagent for isocyanates followed by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis. For hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI), the exposure concentrations were between 4 and 20 p.p.b. and were generated by wet membrane permeation. To reveal the profile of adsorption in different layers of the respirator filters, representative samples from each of the layers were hydrolyzed. The hydrolysis products hexamethylene diamine and isophorone diamine were determined after derivatization with pentafluoropropionic anhydride (PFPA) followed by LC-MS/MS analysis. The two filter types studied efficiently absorbed both ICA and MIC. There was no trend of impaired performance throughout 48-h exposure tests. Even when the filters were exposed to high concentrations (approximately 200 p.p.b.) of ICA and MIC for 96 h, the isocyanates were efficiently absorbed with only a limited breakthrough. The majority of the HDI and IPDI (>90%) were absorbed in the top layers of the absorbant, but HDI and IPDI penetrated farther down into the respirator filters during 120 h of exposure as compared to 16 h exposure.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Filtración/instrumentación , Isocianatos/análisis , Dispositivos de Protección Respiratoria/normas , Adsorción , Contaminantes Ocupacionales del Aire/química , Carbón Orgánico/química , Cromatografía Liquida , Cianatos/análisis , Cianatos/química , Ambiente Controlado , Monitoreo del Ambiente/instrumentación , Diseño de Equipo , Filtración/normas , Calor , Humanos , Humedad , Hidrólisis , Isocianatos/química , Ensayo de Materiales/métodos , Exposición Profesional/prevención & control , Exposición Profesional/estadística & datos numéricos , Urea/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA