Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36203742

RESUMEN

Background and purpose: This study evaluated translational and rotational intra-fractional patient movement during spinal stereotactic body radiotherapy (SBRT) using 6D positioning based on 3D cone beam computerized tomography (CBCT) and stereoscopic kilovoltage imaging (ExacTrac). The aim was to determine whether additional intra-fractional image verification reduced intra-fractional motion without significantly prolonging treatment time, whilst maintaining acceptable imaging related dose. Materials and methods: A retrospective analysis of 38 patients with 41 primary tumour volumes treated with SBRT between September 2018 and May 2021 was performed. Three different image-guided radiotherapy (IGRT) workflows were assessed. The translational and rotational positioning errors for the different imaging workflows, 3D translational vectors and estimates of imaging dose delivered for the different imaging workflows were evaluated. Results: As the frequency of intra-fractional imaging increased from workflow 1 to 3, the mean intra-fraction 3D translational vector improved from 0.91 mm (±0.52 mm), to 0.64 (±0.34 mm). 85 %, 83 % and 97 % of images were within a tolerance of 1 mm/1° for workflows 1, 2 and 3 respectively, based on post treatment CBCT images. The average treatment time for workflow 3 was 13 min, as compared to 12 min for workflows 1 and 2. The effective dose per treatment for IGRT workflows 1, 2 and 3 measured 0.6 mSv, 0.95 mSv and 1.8 mSv respectively. Conclusion: The study demonstrated that the use of additional intra-fractional stereoscopic kilovoltage image-guidance during spinal SBRT, reduced the number of measurements deemed "out of tolerance" and treatment delivery could be optimized within a standard treatment timeslot without applying substantial additional radiation dose.

2.
Phys Med Biol ; 59(10): 2457-68, 2014 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-24778349

RESUMEN

In radiation therapy, high energy photon and proton beams cause the production of secondary neutrons. This leads to an unwanted dose contribution, which can be considerable for tissues outside of the target volume regarding the long term health of cancer patients. Due to the high biological effectiveness of neutrons in regards to cancer induction, small neutron doses can be important. This study quantified the neutron doses for different radiation therapy modalities. Most of the reports in the literature used neutron dose measurements free in air or on the surface of phantoms to estimate the amount of neutron dose to the patient. In this study, dose measurements were performed in terms of neutron dose equivalent inside an anthropomorphic phantom. The neutron dose equivalent was determined using track etch detectors as a function of the distance to the isocenter, as well as for radiation sensitive organs. The dose distributions were compared with respect to treatment techniques (3D-conformal, volumetric modulated arc therapy and intensity-modulated radiation therapy for photons; spot scanning and passive scattering for protons), therapy machines (Varian, Elekta and Siemens linear accelerators) and radiation quality (photons and protons). The neutron dose equivalent varied between 0.002 and 3 mSv per treatment gray over all measurements. Only small differences were found when comparing treatment techniques, but substantial differences were observed between the linear accelerator models. The neutron dose equivalent for proton therapy was higher than for photons in general and in particular for double-scattered protons. The overall neutron dose equivalent measured in this study was an order of magnitude lower than the stray dose of a treatment using 6 MV photons, suggesting that the contribution of the secondary neutron dose equivalent to the integral dose of a radiotherapy patient is small.


Asunto(s)
Neutrones/uso terapéutico , Dosis de Radiación , Radioterapia Asistida por Computador/métodos , Adolescente , Humanos , Masculino , Neutrones/efectos adversos , Órganos en Riesgo/efectos de la radiación , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Radioterapia Asistida por Computador/efectos adversos , Rabdomiosarcoma/radioterapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA