Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 78
Filtrar
1.
Sci Rep ; 13(1): 6646, 2023 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-37095138

RESUMEN

Bioactive glass (BAG) is a bone substitute that can be used in orthopaedic surgery. Following implantation, the BAG is expected to be replaced by bone via bone growth and gradual degradation of the BAG. However, the hydroxyapatite mineral forming on BAG resembles bone mineral, not providing sufficient contrast to distinguish the two in X-ray images. In this study, we co-registered coded-excitation scanning acoustic microscopy (CESAM), scanning white light interferometry (SWLI), and scanning electron microscopy with elemental analysis (Energy Dispersive X-ray Spectroscopy) (SEM-EDX) to investigate the bone growth and BAG reactions on a micron scale in a rabbit bone ex vivo. The acoustic impedance map recorded by the CESAM provides high elasticity-associated contrast to study materials and their combinations, while simultaneously producing a topography map of the sample. The acoustic impedance map correlated with the elemental analysis from SEM-EDX. SWLI also produces a topography map, but with higher resolution than CESAM. The two topography maps (CESAM and SWLI) were in good agreement. Furthermore, using information from both maps simultaneously produced by the CESAM (acoustic impedance and topography) allowed determining regions-of-interest related to bone formation around the BAG with greater ease than from either map alone. CESAM is therefore a promising tool for evaluating the degradation of bone substitutes and the bone healing process ex vivo.


Asunto(s)
Sustitutos de Huesos , Microscopía Acústica , Animales , Conejos , Sustitutos de Huesos/química , Vidrio/química , Osteogénesis , Interferometría , Microscopía Electrónica de Rastreo
2.
J Pharm Biomed Anal ; 224: 115169, 2023 Feb 05.
Artículo en Inglés | MEDLINE | ID: mdl-36462249

RESUMEN

Most new small drug molecules in pharmaceutical development require improvement of solubility. The controlled expansion of supercritical solutions (CESS®) process is a nanoparticle production technology, dedicated to enhancing the dissolution rate of active pharmaceutical ingredients (APIs) suffering from poor solubility and enabling novel drug delivery opportunities. In this process, the API is dissolved in supercritical carbon dioxide (scCO2) and nanoparticles are formed through controlled pressure reduction. To improve process visibility and control, ultraviolet-visible (UV-Vis) spectroscopy was incorporated into CESS® process as a process analytical technology (PAT) tool. The tool quantifies the amount of API dissolved in scCO2 during the solubilization phase of the process. Sample interfacing of the UV-Vis spectrometer was done with a custom-made pressure and temperature rated transmission flow-through cell. In-process calibration was developed to correlate the UV-Vis absorption spectra to the API concentration. Due to the density-dependent molar absorption coefficient of API in scCO2, the calibration was done for each combination of temperature and pressure. The developed PAT tool provides insight into the process enabling real-time API quantity estimation. It also facilitates process development through Quality by Design (QbD) and offers a system for enhanced process control and troubleshooting. For instance, the in-line API concentration data allows one to study the solubilization behavior of the API in the process and to optimize the process parameters in order to maximize throughput.


Asunto(s)
Nanopartículas , Preparaciones Farmacéuticas/química , Análisis Espectral , Temperatura , Solubilidad , Nanopartículas/química
3.
Sci Rep ; 12(1): 18318, 2022 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-36351930

RESUMEN

The benefits of continuous glucose monitoring (CGM) in diabetes management are extensively documented. Yet, the broader adoption of CGM systems is limited by their cost and invasiveness. Current CGM devices, requiring implantation or the use of hypodermic needles, fail to offer a convenient solution. We have demonstrated that magnetohydrodynamics (MHD) is effective at extracting dermal interstitial fluid (ISF) containing glucose, without the use of needles. Here we present the first study of ISF sampling with MHD for glucose monitoring in humans. We conducted 10 glucose tolerance tests on 5 healthy volunteers and obtained a significant correlation between the concentration of glucose in ISF samples extracted with MHD and capillary blood glucose samples. Upon calibration and time lag removal, the data indicate a Mean Absolute Relative Difference (MARD) of 12.9% and Precision Absolute Relative Difference of 13.1%. In view of these results, we discuss the potential value and limitations of MHD in needle-free glucose monitoring.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1 , Humanos , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia , Proyectos Piloto , Voluntarios Sanos , Glucosa
4.
Ultrason Sonochem ; 85: 105970, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35367736

RESUMEN

Lipid-based materials, such as substitutes for saturated fats (oleogels) structurally modified with ultrasonic standing waves (USW), have been developed by our group. To enable their potential application in food products, pharmaceuticals, and cosmetics, practical and economical production methods are needed. Here, we report scale-up of our procedure of structurally modifying oleogels via the use of USW by a factor of 200 compared to our previous microfluidic chamber. To this end, we compared three different USW chamber prototypes through finite element simulations (FEM) and experimental work. Imaging of the internal structure of USW-treated oleogels was used as feedback for successful development of chambers, i.e., the formation of band-like structures was the guiding factor in chamber development. We then studied the bulk mechanical properties by a uniaxial compression test of the sonicated oleogels obtained with the most promising USW chamber, and sampled local mechanical properties using scanning acoustic microscopy. The results were interpreted using a hyperelastic foam model. The stability of the sonicated oleogels was compared to control samples using automated image analysis oil-release tests. This work enabled the effective mechanical-structural manipulation of oleogels in volumes of 10-100 mL, thus paving the way for USW treatments of large-scale lipid-based materials.


Asunto(s)
Compuestos Orgánicos , Ultrasonido , Ácidos Grasos/análisis , Compuestos Orgánicos/química , Ondas Ultrasónicas
5.
Biosens Bioelectron ; 206: 114123, 2022 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-35259608

RESUMEN

We integrated a magnetohydrodynamic fluid extractor with an amperometric glucose biosensor to develop a wearable device for non-invasive glucose monitoring. Reproducible fluid extraction through the skin and efficient transport of the extracted fluid to the biosensor surface are prerequisites for non-invasive glucose monitoring. We optimized the enzyme immobilization and the interface layer between the sensing device and the skin. The monitoring device was evaluated by extracting fluid through porcine skin followed by glucose detection at the biosensor. The biosensor featured a screen-printed layer of Prussian Blue that was coated with a layer containing glucose oxidase. Both physical entrapment of glucose oxidase in chitosan and tethering of glucose oxidase to electrospun nanofibers were evaluated. Binding of glucose oxidase to nanofibers under mild conditions provided a stable biosensor with analytical performance suitable for accurate detection of micromolar concentrations of glucose. Hydrogels of varying thickness (95-2000 µm) as well as a thin (30 µm) nanofibrous polycaprolactone mat were studied as an interface layer between the biosensor and the skin. The effect of mass transfer phenomena at the biosensor-skin interface on the analytical performance of the biosensor was evaluated. The sensing device detected glucose extracted through porcine skin with an apparent (overall) sensitivity of -0.8 mA/(M·cm2), compared to a sensitivity of -17 mA/(M·cm2) for measurement in solution. The amperometric response of the biosensor correlated with the glucose concentration in the fluid that had been extracted through porcine skin with the magnetohydrodynamic technique.


Asunto(s)
Técnicas Biosensibles , Glucosa Oxidasa , Glucemia , Automonitorización de la Glucosa Sanguínea , Enzimas Inmovilizadas , Líquido Extracelular , Glucosa
6.
Ultrason Sonochem ; 79: 105798, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34662805

RESUMEN

Pipe fouling is a challenging problem in many industrial applications. Current cleaning techniques require halting the production during the cleaning phase and the existing methods are unable to do targeted cleaning, even though fouling is often localized to certain areas inside the pipeline. To address this issue, we use FEM-simulated, time-reversed signals to focus ultrasound power onto a pre-determined location: a fouled pipe residing inside a Plexiglas container. Ultrasound cleaning with similar acoustic power was compared to the time-reversal enhanced method in terms of cleaning efficiency. The cleaning efficiency was determined by measuring how much fouling, by mass, both protocols removed from the surface of a Plexiglas pipe, using similar input electric power and equal cleaning time. Our results indicate that the proposed time-reversal-based technique removes three times more fouling than the standard ultrasound cleaning without focusing. The study extends our previous paper on FEM-based time-reversal focusing [1].

7.
Rev Sci Instrum ; 92(7): 074901, 2021 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-34340418

RESUMEN

Scanning acoustic microscopy (SAM) finds use across many disciplines, e.g., biology, industrial quality control, and materials science, thanks to its unique ability to quantify mechanical sample properties combined with its high resolution. However, such imaging is often slow, especially if averaging is necessary. We present a Coded Excitation Scanning Acoustic Microscope (CESAM) that employs coded signals and show that it produces images of higher signal-to-noise ratios (SNRs) than the classical SAM in a comparable measurement time. The CESAM employs coded signals instead of the short bursts used in traditional SAMs, and we employ both linear and non-linear frequency modulation. Our results show that compared to the SAM approach, this modulation increases the SNR by 16.3 dB (from 39.9 to 56.2 dB) and reduces the echo duration by 26.7% when we employ a linear chirp to the transducer with a nominal bandwidth of 130-370 MHz. Driving the transducer with a broader bandwidth signal using non-linear chirps (100-450 MHz), we obtained a SNR increase of 10.3 dB and a reduced echo duration of 70.5%. The shorter echo duration increases z-resolution, whereas the lateral resolution remains limited by the wavelength. Finally, we show that by using these coded signals, one can obtain enhanced image quality relative to the standard actuation of the same measurement time. Our results have potential to invigorate the field of acoustic microscopy, especially with samples where the enhanced SNR and/or contrast-to-noise ratio is crucial for image quality.


Asunto(s)
Microscopía Acústica , Transductores , Acústica , Relación Señal-Ruido , Ultrasonografía
8.
MethodsX ; 8: 101447, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34434858

RESUMEN

We present an automated method to determine oil release from lipid-based materials. Oil-release tests can provide information regarding the ability to retain oil within the structuring network of lipid-based materials. This test provides a first insight into the stability of these materials and their possible applications in food, cosmetic, and pharmaceutical products. The method presented features a simple setup comprising a camera that automatically captures images of the evolution of the oil stain released from lipid-based materials placed on a filter paper. Image postprocessing is performed with two custom-made scripts developed for the freeware application ImageJ. The scripts allow direct calculation of the oil-stain area from all images stored in a folder returning as output numerical values in a table. This method was shown to be:•inexpensive, as the employed tools and equipment are available in most laboratories both in academia and industry,•self-running, as the method automatically captures images at predefined time intervals for a certain time span,•practical, as manual-image analysis is unnecessary (200 images can be automatically analyzed in 3 min).

9.
Sci Rep ; 11(1): 15191, 2021 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-34312423

RESUMEN

The primary goal of this study is to localize a defect (cavity) in a curved geometry. Curved topologies exhibit multiple resonances and the presence of hotspots for acoustic waves. Launching acoustic waves along a specific direction e.g. by means of an extended laser source reduces the complexity of the scattering problem. We performed experiments to demonstrate the use of a laser line source and verified the experimental results in FEM simulations. In both cases, we could locate and determine the size of a pit in a steel hemisphere which allowed us to visualize the defect on a 3D model of the sample. Such an approach could benefit patients by enabling contactless inspection of acetabular cups.

10.
Sci Rep ; 11(1): 7609, 2021 04 07.
Artículo en Inglés | MEDLINE | ID: mdl-33828144

RESUMEN

Out of 463 million people currently with diabetes, 232 million remain undiagnosed. Diabetes is a threat to human health, which could be mitigated via continuous self-monitoring of glucose. In addition to blood, interstitial fluid is considered to be a representative sample for glucose monitoring, which makes it highly attractive for wearable on-body sensing. However, new technologies are needed for efficient and noninvasive sampling of interstitial fluid through the skin. In this report, we introduce the use of Lorentz force and magnetohydrodynamics to noninvasively extract dermal interstitial fluid. Using porcine skin as an ex-vivo model, we demonstrate that the extraction rate of magnetohydrodynamics is superior to that of reverse iontophoresis. This work seeks to provide a safe, effective, and noninvasive sampling method to unlock the potential of wearable sensors in needle-free continuous glucose monitoring devices that can benefit people living with diabetes.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Líquido Extracelular/química , Glucosa/análisis , Animales , Técnicas Biosensibles/instrumentación , Diabetes Mellitus/metabolismo , Glucosa/metabolismo , Hidrodinámica , Imanes/química , Modelos Animales , Piel/metabolismo , Fenómenos Fisiológicos de la Piel , Porcinos , Dispositivos Electrónicos Vestibles
11.
Sci Rep ; 11(1): 8234, 2021 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-33859220

RESUMEN

Despite the ubiquitous use over the past 150 years, the functions of the current medical needle are facilitated only by mechanical shear and cutting by the needle tip, i.e. the lancet. In this study, we demonstrate how nonlinear ultrasonics (NLU) extends the functionality of the medical needle far beyond its present capability. The NLU actions were found to be localized to the proximity of the needle tip, the SonoLancet, but the effects extend to several millimeters from the physical needle boundary. The observed nonlinear phenomena, transient cavitation, fluid streams, translation of micro- and nanoparticles and atomization, were quantitatively characterized. In the fine-needle biopsy application, the SonoLancet contributed to obtaining tissue cores with an increase in tissue yield by 3-6× in different tissue types compared to conventional needle biopsy technique using the same 21G needle. In conclusion, the SonoLancet could be of interest to several other medical applications, including drug or gene delivery, cell modulation, and minimally invasive surgical procedures.


Asunto(s)
Agujas , Ultrasonografía Intervencional , Animales , Biopsia con Aguja Fina/instrumentación , Biopsia con Aguja Fina/métodos , Bovinos , Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Técnicas de Transferencia de Gen/instrumentación , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fantasmas de Imagen , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Ultrasonido/instrumentación , Ultrasonido/métodos , Ultrasonografía Intervencional/instrumentación , Ultrasonografía Intervencional/métodos
12.
Sci Rep ; 10(1): 14448, 2020 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-32879336

RESUMEN

Oleogels are lipid-based soft materials composed of large fractions of oil (> 85%) developed as saturated and hydrogenated fat substitutes to reduce cardiovascular diseases caused by obesity. Promising oleogels are unstable during storage, and to improve their stability careful control of the crystalline network is necessary. However, this is unattainable with state-of-the-art technologies. We employ ultrasonic standing wave (USSW) fields to modify oleogel structure. During crystallization, the growing crystals move towards the US-SW nodal planes. Homogeneous, dense bands of microcrystals form independently of oleogelator type, concentration, and cooling rate. The thickness of these bands is proportional to the USSW wavelength. These new structures act as physical barriers in reducing the migration kinetics of a liposoluble colorant compared to statically crystallized oleogels. These results may extend beyond oleogels to potentially be used wherever careful control of the crystallization process and final structure of a system is needed, such as in the cosmetics, pharmaceutical, chemical, and food industries.

13.
PLoS One ; 15(2): e0227488, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32012155

RESUMEN

People suffering from glaucoma often endure high intra-ocular pressure (IOP). Methods for determining IOP either contact the eye or are unpleasant to some patients. There is therefore a need for a rapid and patient friendly non-contacting method to determine IOP. To address this need, we developed a tonometer prototype that employs spark-gap induced shock waves and a laser Doppler vibrometer (LDV) that reads the amplitude of membrane waves. The IOP was first identified from the membrane wave propagation velocity first in a custom-made ocular phantom and was then verified in ex vivo porcine eyes. The time-of-flight (TOF) of the membrane wave travelling on a hemispherical membrane was compared to reference IOP values in the sample obtained with an iCare TA01 tonometer. The shock front was characterized by high speed photography. Within one eye, the method achieved an agreement of 5 mmHg (1.96 standard deviation between the shock wave tonometer and the commercial manometer) and high method-to-method association (Pearson correlation, R2 = 0.98). The results indicate that the presented method could potentially be developed into a non-contacting technique for measuring IOP in vivo.


Asunto(s)
Glaucoma/diagnóstico , Flujometría por Láser-Doppler/métodos , Hipertensión Ocular/diagnóstico , Tonometría Ocular/métodos , Animales , Ojo/diagnóstico por imagen , Ojo/fisiopatología , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Hipertensión Ocular/fisiopatología , Fotograbar , Estudios Prospectivos , Porcinos
14.
Sci Rep ; 9(1): 15937, 2019 11 04.
Artículo en Inglés | MEDLINE | ID: mdl-31685841

RESUMEN

Localized delivery of drugs into an osteoarthritic cartilaginous lesion does not yet exist, which limits pharmaceutical management of osteoarthritis (OA). High-intensity focused ultrasound (HIFU) provides a means to actuate matter from a distance in a non-destructive way. In this study, we aimed to deliver methylene blue locally into bovine articular cartilage in vitro. HIFU-treated samples (n = 10) were immersed in a methylene blue (MB) solution during sonication (f = 2.16 MHz, peak-positive-pressure = 3.5 MPa, mechanical index = 1.8, pulse repetition frequency = 3.0 kHz, cycles per burst: 50, duty cycle: 7%). Adjacent control 1 tissue (n = 10) was first pre-treated with HIFU followed by immersion into MB; adjacent control 2 tissue (n = 10) was immersed in MB without ultrasound exposure. The MB content was higher (p < 0.05) in HIFU-treated samples all the way to a depth of 600 µm from AC surface when compared to controls. Chondrocyte viability and RNA expression levels associated with cartilage degeneration were not different in HIFU-treated samples when compared to controls (p > 0.05). To conclude, HIFU delivers molecules into articular cartilage without major short-term concerns about safety. The method is a candidate for a future approach for managing OA.


Asunto(s)
Cartílago Articular/metabolismo , Ultrasonido Enfocado de Alta Intensidad de Ablación , Animales , Cartílago Articular/química , Bovinos , Supervivencia Celular/efectos de los fármacos , Condrocitos/citología , Condrocitos/metabolismo , Metaloproteinasas de la Matriz/genética , Metaloproteinasas de la Matriz/metabolismo , Azul de Metileno/química , Azul de Metileno/metabolismo , Azul de Metileno/farmacología , Osteoartritis/metabolismo , Osteoartritis/patología , Osteoartritis/veterinaria , Factor de Crecimiento Transformador beta/genética , Factor de Crecimiento Transformador beta/metabolismo
15.
Pharmaceutics ; 11(10)2019 Sep 26.
Artículo en Inglés | MEDLINE | ID: mdl-31561640

RESUMEN

We investigated nozzleless ultrasound-enhanced electrospinning (USES) as means to generate nanofibrous drug delivery systems (DDSs) for pharmaceutical and biomedical applications. Traditional electrospinning (TES) equipped with a conventional spinneret was used as a reference method. High-molecular polyethylene oxide (PEO) and chitosan were used as carrier polymers and theophylline anhydrate as a water-soluble model drug. The nanofibers were electrospun with the diluted mixture (7:3) of aqueous acetic acid (90% v/v) and formic acid solution (90% v/v) (with a total solid content of 3% w/v). The fiber diameter and morphology of the nanofibrous DDSs were modulated by varying ultrasonic parameters in the USES process (i.e., frequency, pulse repetition frequency and cycles per pulse). We found that the USES technology produced nanofibers with higher fiber diameter (402 ± 127 nm) than TES (77 ± 21 nm). An increase of a burst count in USES increased the fiber diameter (555 ± 265 nm) and the variation in fiber size. The slight-to-moderate changes in a solid state (crystallinity) were detected when compared the nanofibers generated by TES and USES. In conclusion, USES provides a promising alternative for aqueous-based fabrication of nanofibrous DDSs for pharmaceutical and biomedical applications.

16.
Pharmaceutics ; 11(10)2019 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-31554258

RESUMEN

We investigated and monitored in situ the wetting and dissolution properties of polymeric nanofibers and determined the solid-state of a drug during dissolution. Piroxicam (PRX) was used as a low-dose and poorly-soluble model drug, and hydroxypropyl methylcellulose (HPMC) and polydextrose (PD) were used as carrier polymers for electrospinning (ES). The initial-stage dissolution of the nanofibers was monitored in situ with three-dimensional white light microscopic interferometry (SWLI) and high-resolution optical microscopy. The physical solid-state characterization of nanofibers was performed with Raman spectroscopy, X-ray powder diffraction (XRPD), and scanning electron microscopy (SEM). We showed that PRX recrystallizes in a microcrystalline form immediately after wetting of nanofibers, which could lead to enhanced dissolution of drug. Initiation of crystal formation was detected by SWLI, indicating: (1) that PRX was partially released from the nanofibers, and (2) that the solid-state form of PRX changed from amorphous to crystalline. The amount, shape, and size of the PRX crystals depended on the carrier polymer used in the nanofibers and dissolution media (pH). In conclusion, the present nanofibers loaded with PRX exhibit a quasi-dynamic dissolution via recrystallization. SWLI enables a rapid, non-contacting, and non-destructive method for in situ monitoring the early-stage dissolution of nanofibers and regional mapping of crystalline changes (re-crystallization) during wetting. Such analysis is crucial because the wetting and dissolution of nanofibers can greatly influence the performance of nanofibrous drug delivery systems in pharmaceutical and biomedical applications.

17.
J Vis Exp ; (149)2019 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-31305514

RESUMEN

Theoretical, numerical, and experimental methods are presented for multiple scattering of light in macroscopic discrete random media of densely-packed microscopic particles. The theoretical and numerical methods constitute a framework of Radiative Transfer with Reciprocal Transactions (R2T2). The R2T2 framework entails Monte Carlo order-of-scattering tracing of interactions in the frequency space, assuming that the fundamental scatterers and absorbers are wavelength-scale volume elements composed of large numbers of randomly distributed particles. The discrete random media are fully packed with the volume elements. For spherical and nonspherical particles, the interactions within the volume elements are computed exactly using the Superposition T-Matrix Method (STMM) and the Volume Integral Equation Method (VIEM), respectively. For both particle types, the interactions between different volume elements are computed exactly using the STMM. As the tracing takes place within the discrete random media, incoherent electromagnetic fields are utilized, that is, the coherent field of the volume elements is removed from the interactions. The experimental methods are based on acoustic levitation of the samples for non-contact, non-destructive scattering measurements. The levitation entails full ultrasonic control of the sample position and orientation, that is, six degrees of freedom. The light source is a laser-driven white-light source with a monochromator and polarizer. The detector is a mini-photomultiplier tube on a rotating wheel, equipped with polarizers. The R2T2 is validated using measurements for a mm-scale spherical sample of densely-packed spherical silica particles. After validation, the methods are applied to interpret astronomical observations for asteroid (4) Vesta and comet 67P/Churyumov-Gerasimenko (Figure 1) recently visited by the NASA Dawn mission and the ESA Rosetta mission, respectively.


Asunto(s)
Absorción de Radiación , Luz , Planetas , Dispersión de Radiación , Campos Electromagnéticos , Método de Montecarlo , Refractometría , Dióxido de Silicio/química , Vuelo Espacial
18.
Sci Rep ; 9(1): 5189, 2019 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-30914658

RESUMEN

Studies in optics and acoustics have employed metamaterial lenses to achieve sub-wavelength localization, e.g. a recently introduced concept called 'acoustojet' which in simulations localizes acoustic energy to a spot smaller than λ/2. However previous experimental results on the acoustojet have barely reached λ/2-wide localization. Here we show, by simulations and experiments, that a sub-λ/2 wide localization can be achieved by translating the concept of a photonic jet into the acoustic realm. We performed nano- to macroscale molecular dynamics (MD) and finite element method (FEM) simulations as well as macroscale experiments. We demonstrated that by choosing a suitable size cylindrical lens, and by selecting the speed-of-sound ratio between the lens material(s) and the surrounding medium, an acoustic jet ('acoustic sheet') is formed with a full width at half maximum (FWHM) less than λ/2. The results show, that the acoustojet approach can be experimentally realized with easy-to-manufacture acoustic lenses at the macroscale. MD simulations demonstrate that the concept can be extended to coherent phonons at nanoscale. Finally, our FEM simulations identify some micrometer size structures that could be realized in practice. Our results may contribute to starting a new era of super resolution acoustic imaging: We foresee that jet generating constructs can be readily manufactured, since suitable material combinations can be found from nanoscale to macroscale. Tight focusing of mechanical energy is highly desirable in e.g. electronics, materials science, medicine, biosciences, and energy harvesting.

19.
J Orthop Res ; 37(4): 855-866, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30737811

RESUMEN

One of the earliest changes in osteoarthritis (OA) is a surface discontinuity of the articular cartilage (AC), and these surface changes become gradually more complex with OA progression. We recently developed a contrast enhanced micro-computed tomography (µCT) method for visualizing AC surface in detail. The present study aims to introduce a µCT analysis technique to parameterize these complex AC surface features and to demonstrate the feasibility of using these parameters to quantify degenerated AC surface. Osteochondral plugs (n = 35) extracted from 19 patients undergoing joint surgery were stained with phosphotungstic acid and imaged using µCT. The surface micro-topography of AC was analyzed with developed method. Standard root mean square roughness (Rq ) was calculated as a reference, and the Area Under Curve (AUC) for receiver operating characteristic analysis was used to compare the acquired quantitative parameters with semi-quantitative visual grading of µCT image stacks. The parameters quantifying the complex micro-topography of AC surface exhibited good sensitivity and specificity in identifying surface continuity (AUC: 0.93, [0.80 0.99]), fissures (AUC: 0.94, [0.83 0.99]) and fibrillation (AUC: 0.98, [0.88 1.0]). Standard Rq was significantly smaller compared with the complex roughness (CRq ) already with mild surface changes with all surface reference parameters - continuity, fibrillation, and fissure sum. Furthermore, only CRq showed a significant difference when comparing the intact surface with lowest fissure sum score. These results indicate that the presented method for evaluating complex AC surfaces exhibit potential to identify early OA changes in superficial AC and is dynamic throughout OA progression. © 2019 The Authors. Journal of Orthopaedic Research® Published by Wiley Periodicals, Inc. on behalf of the Orthopaedic Research Society. Society. 9999:1-12, 2019.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Ácido Fosfotúngstico , Microtomografía por Rayos X/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/diagnóstico por imagen
20.
J Sleep Res ; 28(2): e12755, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30133045

RESUMEN

Prolonged time awake increases the need to sleep. Sleep pressure increases sleepiness, impairs human alertness and performance and increases the probability of human errors and accidents. Human performance and alertness during waking hours are influenced by homeostatic sleep drive and the circadian rhythm. Cognitive functions, especially attentional ones, are vulnerable to circadian rhythm and increasing sleep drive. A reliable, objective and practical metrics for estimating sleepiness could therefore be valuable. Our aim is to study whether saccades measured with electro-oculography (EOG) outside the laboratory could be used to estimate the overall time awake without sleep of a person. The number of executed saccades was measured in 11 participants during an 8-min saccade task. The saccades were recorded outside the laboratory (Naval Academy, Bergen) using EOG every sixth hour until 54 hr of time awake. Measurements were carried out on two occasions separated by 10 weeks. Five participants participated in both measurement weeks. The number of saccades decreased during sustained wakefulness. The data correlated with the three-process model of alertness; performance differed between participants but was stable within individual participants. A mathematically monotonous relation between performance in the saccade task and time awake was seen after removing the circadian rhythm component from measured eye movement data. The results imply that saccades measured with EOG can be used as a time-awake metric outside the laboratory.


Asunto(s)
Movimientos Oculares/fisiología , Movimientos Sacádicos/fisiología , Vigilia/fisiología , Adulto , Humanos , Masculino , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...