1.
Heart ; 91(12): 1584-9, 2005 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15797938

RESUMEN

OBJECTIVE: To compare acute and follow up clinical and angiographic results after treatment of in-stent restenosis (ISR) by sirolimus eluting stents (SES) with results obtained after intracoronary radiation therapy (IRT). DESIGN: Matched pair analysis. METHODS: 62 consecutive ISR lesions (< 30 mm lesion length, reference diameter < 3.5 mm) in 62 patients were treated with SES. From a database of 174 lesions (n = 141 patients) treated for ISR by intracoronary beta radiation, 62 lesions (62 patients) were pair matched with the SES group for diabetes mellitus, lesion length, vessel size, and pattern of ISR. Six month angiographic and 12 month clinical follow up results were obtained. RESULTS: Baseline clinical and angiographic characteristics were similar between the groups (not significant). SES implantation resulted in significantly lower postprocedural in-lesion diameter stenosis than did IRT (mean (SD) 14.2 (9.5)% v 21.1 (10.6)%, p = 0.001), significantly higher minimum lumen diameter at follow up (1.91 (0.58) v 1.55 (0.72) mm, p = 0.005), and a higher net gain (1.16 (0.55) v 0.77 (0.70) mm, p = 0.002). Angiographic binary in-lesion restenosis rate at six months was 11% in the SES group and 29% in the IRT group (p = 0.046). In 16 ISR lesions SES were used after failed IRT and in 46 lesions for first time ISR. In-lesion late loss was higher after use of SES for failed IRT than after use of SES for first time ISR (0.61 (0.67) mm v 0.24 (0.41) mm, p = 0.018). In a multivariate analysis prior failed IRT was the only independent predictor for recurrent restenosis after SES for ISR (p = 0.052, odds ratio 5.8). Six patients (10%) in the SES group and 17 patients (27%) in the IRT group underwent target lesion revascularisation during the 12 months of follow up (p = 0.022). CONCLUSIONS: In this non-randomised matched cohort SES achieved acute and follow up results superior to IRT for treatment of ISR even if cases of failed IRT are included. Failed IRT is a predictor of impaired SES effectiveness.


Asunto(s)
Reestenosis Coronaria/tratamiento farmacológico , Reestenosis Coronaria/radioterapia , Inmunosupresores/administración & dosificación , Sirolimus/administración & dosificación , Stents , Partículas beta , Braquiterapia/métodos , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Implantes de Medicamentos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
2.
Minerva Cardioangiol ; 50(5): 555-63, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12384637

RESUMEN

Restenosis after coronary stent implantation remains the major limitation of this treatment modality. At present, re-dilatation is considered the therapeutic option of choice for focal lesions, however, long restenotic lesions (>10 mm) do not respond favourably. Despite the emerging concept of intracoronary radiation, encouraging acute procedural results are also reported for different debulking techniques (Excimer laser angioplasty, directional coronary atherectomy, and rotational atherectomy, or rotablation). Rotablation has been studied most extensively with acute and long- term results published in a total of more than 850 patients. Experimental and first clinical data indicate favourable results for the rotablator as compared to balloon angioplasty alone for the treatment of in-stent restenosis. Data from the first 2 randomized clinical trials (ROSTER-, and ARTIST-trial) have now been published with conflicting results: The european multicenter ARTIST-trial including 300 patients could not prove a benefit for the rotablator as compared to re-dilatation in patients with diffuse stent restenosis. On the contrary, the monocenter ROSTER-trial, which has been presented as an abstract until today, suggests a clinical benefit of patients treated by the rotablator if they were studied with intracoronary ultrasound prior to randomization. Currently, rotablation for the treatment of restenosis cannot be considered as the first line treatment modality in patients with in-stent restenosis. As a result of unsatisfying angiographic and clinical long-term results by the use of a variety of treatment modalities in diffuse stent restenosis, prevention of this iatrogenic entity has become mandatory.


Asunto(s)
Angioplastia Coronaria con Balón , Aterectomía/métodos , Reestenosis Coronaria/cirugía , Stents , Anciano , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Ultrasonografía Intervencional
3.
Eur Heart J ; 22(21): 2007-14, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11603908

RESUMEN

AIMS: Histological restenosis models in animals have indicated that stent design has a significant impact on vessel trauma during stent implantation and on the amount of subsequent neointimal tissue proliferation. The impact of different stent designs on intimal hyperplasia in human atherosclerotic coronary arteries has not been determined. METHODS AND RESULTS: Angiographic and intravascular ultrasound studies were performed at the 6 month follow-up in 131 consecutive native coronary lesions of 131 patients treated with 50 Multi-Link stents, 40 InFlow stents and 41 Palmaz-Schatz stents. Lumen and stent cross-sectional areas (CSA) were measured at 1 mm axial increments. Mean intimal hyperplasia cross-sectional area (stent CSA-lumen CSA) and mean intimal hyperplasia thickness were calculated. Intravascular ultrasound demonstrated different levels of intimal hyperplasia proliferation for the three stents. Mean intimal hyperplasia thickness was 0.16+/-0.08 mm for Multi-Link stents, 0.26+/-0.19 mm for Palmaz-Schatz stents and 0.39+/-0.14 mm for Inflow stents (P<0.001). Multivariate analysis proved that stent type was the only independent predictor of intimal hyperplasia thickness at follow-up (P<0.001). CONCLUSION: Coronary stent design has a significant impact on subsequent intimal hyperplasia after implantation into atherosclerotic human coronary arteries. The corrugated ring design of the Multi-Link stent proved to result in less tissue proliferation at 6-month follow-up than the tubular slotted design of Palmaz-Schatz and InFlow stents.


Asunto(s)
Enfermedad Coronaria/terapia , Vasos Coronarios/patología , Stents/efectos adversos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/patología , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Hiperplasia/patología , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Túnica Íntima/patología , Ultrasonografía Intervencional
4.
Heart ; 84(4): 403-8, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-10995410

RESUMEN

OBJECTIVE: To assess long term results of coronary stent implantation in patients with symptomatic myocardial bridging. METHODS: Intracoronary stent implantation was performed within the intramural course of the left anterior descending coronary artery in 11 patients with objective signs of myocardial ischaemia and absence of other cardiac disorders. All had myocardial bridging of the central portion of the left anterior descending coronary artery. Quantitative coronary angiography was performed before and after stent deployment, and again at seven weeks and six months. Clinical evaluation was done at two years. RESULTS: After stent deployment, quantitative coronary angiography showed absence of systolic compression along the left anterior descending coronary artery; the minimum luminal diameter (mean (SD)) increased from 0.6 (0.3) mm before stent implantation to 1.9 (0.3) mm after implantation (p < 0. 05). Intravascular ultrasound showed an increase in cross sectional area from 3.3 (1.3) mm(2) at baseline to 6.8 (0.9) mm(2) (p < 0.005) after stent deployment. Coronary flow reserve was normalised from 2. 6 (0.5) at baseline to 4.0 (0.5) (p < 0.005) after stent implantation. At seven weeks, quantitative coronary angiography showed mild to moderate or severe in-stent stenosis in five of the 11 patients; four of these underwent repeat target vessel revascularisation (percutaneous transluminal coronary angioplasty in two; coronary artery bypass grafting in two). At six months, all patients (n = 9) showed good angiographic results, including those who had target vessel revascularisation. On clinical evaluation at two years, all patients (including those with target vessel revascularisation) remained free of angina and cardiac events. CONCLUSIONS: Intracoronary stent implantation prevents external compression of bridged coronary artery segments, with increase in luminal diameter and alleviation of symptoms. The incidence of in-stent stenosis requiring target vessel revascularisation (36%) is comparable with that of lesions of 25 mm length in coronary artery disease. The symptom free and event free two year follow up data suggest that stent implantation is a useful way of treating symptomatic patients with myocardial bridges.


Asunto(s)
Angiografía Coronaria , Isquemia Miocárdica/terapia , Stents , Adulto , Anciano , Análisis de Varianza , Circulación Coronaria , Vasos Coronarios/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/patología , Miocardio/patología , Recurrencia
6.
J Am Coll Cardiol ; 34(1): 33-9, 1999 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-10399989

RESUMEN

OBJECTIVES: This quantitative angiographic and intravascular ultrasound study determined the mechanisms of acute lumen enlargement and recurrent restenosis after rotational atherectomy (RA) with adjunct percutaneous transluminal coronary angioplasty in the treatment of diffuse in-stent restenosis (ISR). BACKGROUND: In-stent restenosis remains a significant clinical problem for which optimal treatment is under debate. Rotational atherectomy has become an alternative therapeutic approach for the treatment of diffuse ISR based on the concept of "tissue-debulking." METHODS: Rotational atherectomy with adjunct angioplasty of ISR was used in 45 patients with diffuse lesions. Quantitative coronary angiographic (QCA) analysis and sequential intravascular ultrasound (IVUS) measurements were performed in all patients. Forty patients (89%) underwent angiographic six-month follow-up. RESULTS: Rotational atherectomy lead to a decrease in maximal area of stenosis from 80+/-32% before intervention to 54+/-21% after RA (p < 0.0001) as a result of a significant decrease in intimal hyperplasia cross-sectional area (CSA). The minimal lumen diameter after RA remained 15+/-4% smaller than the burr diameter used, indicating acute neointimal recoil. Additional angioplasty led to a further decrease in area of stenosis to 38+/-12% due to a significant increase in stent CSA. At six-month angiographic follow-up, recurrent restenosis rate was 45%. Lesion and stent length, preinterventional diameter stenosis and amount of acute neointimal recoil were associated with a higher rate of recurrent restenosis. CONCLUSIONS: Rotational atherectomy of ISR leads to acute lumen gain by effective plaque removal. Adjunct angioplasty results in additional lumen gain by further stent expansion and tissue extrusion. Stent and lesion length, severity of ISR and acute neointimal recoil are predictors of recurrent restenosis.


Asunto(s)
Aterectomía Coronaria , Angiografía Coronaria , Enfermedad Coronaria/terapia , Oclusión de Injerto Vascular/terapia , Stents , Ultrasonografía Intervencional , Anciano , Angioplastia Coronaria con Balón , Vasos Coronarios/patología , Femenino , Oclusión de Injerto Vascular/patología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
7.
Am J Cardiol ; 83(6): 862-7, 1999 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-10190400

RESUMEN

Due to the widespread use of stents in complex coronary lesions, stent restenosis represents an increasing problem, for which optimal treatment is under debate. "Debulking" of in-stent neointimal tissue using percutaneous transluminal rotational atherectomy (PTRA) offers an alternative approach to tissue compression and extrusion achieved by balloon angioplasty. One hundred patients (70 men, aged 58 +/- 11 years) with a first in-stent restenosis underwent PTRA using an incremental burr size approach followed by adjunctive angioplasty. The average lesion length by quantitative angiography was 21 +/- 8 mm (range 5 to 68) including 22 patients with a length > or = 40 mm. Twenty-nine patients had complete stent occlusions with a lesion length of 44 +/- 23 mm. Baseline diameter stenosis measured 78 +/- 17%, was reduced to 32 +/- 9% after PTRA, and further reduced to 21 +/- 10% after adjunctive angioplasty. Primary PTRA was successful in 97 of 100 patients. Clinical success was 97%, whereas 2 patients developed non-Q-wave infarctions without clinical sequelae. Clinical follow-up was available for all patients at 5 +/- 4 months without any cardiac event. Angiography in 72 patients revealed restenosis in 49%, with necessary target lesion reintervention in 35%. The incidence of rerestenosis correlated with the length of the primarily stented segment and the length of a first in-stent restenosis. Thus, PTRA offers an alternative approach to treat diffuse in-stent restenosis. Neointimal debulking of stenosed stents can be achieved effectively and safely. PTRA resulted in an acceptable recurrent restenosis rate in short and modestly diffuse lesion, whereas the restenosis rate in very long lesions remains high despite debulking.


Asunto(s)
Aterectomía Coronaria , Angiografía Coronaria , Enfermedad Coronaria/terapia , Stents , Enfermedad Coronaria/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Retratamiento , Ultrasonografía Intervencional
8.
J Cardiovasc Pharmacol ; 33(1): 126-34, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9890407

RESUMEN

Little information is available concerning the effects of nitrates and potassium channel openers on local poststenotic blood flow in coronary artery disease (CAD). Combined quantitative digital angiography (QCA) and intracoronary Doppler (IVADO) velocity measurements were used to determine changes in absolute poststenotic blood flow after intracoronary injection of 0.2 mg nitroglycerin and 0.5 mg nicorandil. Quantitative blood flow (QBF) was calculated from average peak-flow velocity (APV) and angiographic cross-sectional area (CSA): QBF (ml/min) = CSA x APV x 0.5. In group I (n = 9), 0.5 mg nicorandil i.c. was identified as optimal to achieve maximal vasodilatation. In patients with CAD (group II, n = 12), i.c. injection of 0.5 mg nicorandil induced a significant increase in poststenotic CSA (+38%) and QBF (+50%). In contrast, 0.2 mg nitroglycerin (group III, n = 12) increases poststenotic CSA (+38%) without a significant change in QBF (+23%). Additional application of nicorandil in these patients induced further significant increases in CSA (+55%) and QBF (+48%) compared with baseline. There were no significant changes in stenosis area. Poststenotic blood flow can be increased by nicorandil after application of nitroglycerin. This effect is most likely mediated by the potassium channel-opening effect of nicorandil. Combined use of QCA and IVADO is a unique approach to measure local poststenotic QBF in patients with CAD.


Asunto(s)
Circulación Coronaria/efectos de los fármacos , Enfermedad Coronaria/tratamiento farmacológico , Nicorandil/uso terapéutico , Nitroglicerina/uso terapéutico , Vasodilatadores/uso terapéutico , Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/fisiopatología , Femenino , Hemodinámica/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Nicorandil/farmacología , Nitroglicerina/farmacología , Ultrasonografía Doppler/métodos , Vasodilatadores/farmacología
9.
Ann Thorac Surg ; 66(4): 1444-9, 1998 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-9800863

RESUMEN

Anomalous origin of the right coronary artery from the main pulmonary artery is a rare congenital cardiac malformation. Most patients remain asymptomatic. However, there are cases of sudden cardiac death described in the literature, indicating a potentially malign course of the disease. To establish a double-ostium coronary system, correction of the aberrant vessel is recommended. Despite surgical reconstitution of normal coronary anatomy, the postoperative clinical presentation of some patients does not improve substantially, raising the question of the functional outcome of reinserted coronary vessels. This report of a patient with anomalous origin of the right coronary artery from the pulmonary trunk, in whom a complete hemodynamic assessment including intracoronary Doppler flow measurements was performed before and after reimplantation, very strongly supports the concept of an anatomically corrective operation.


Asunto(s)
Circulación Coronaria , Anomalías de los Vasos Coronarios/fisiopatología , Anomalías de los Vasos Coronarios/diagnóstico por imagen , Anomalías de los Vasos Coronarios/cirugía , Ecocardiografía Doppler , Femenino , Humanos , Persona de Mediana Edad , Arteria Pulmonar/anomalías , Ultrasonografía Intervencional