Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Ultraschall Med ; 31(2): 151-5, 2010 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20306380

RESUMEN

PURPOSE: The acoustic radiation force impulse (ARFI) technology is a novel ultrasound method that provides information about the local elasticity of tissue in real-time. ARFI is integrated in a conventional ultrasound system. The aim of this exploratory study was to evaluate this new technique in the assessment of liver fibrosis in a cohort with chronic viral hepatitis B and C and to ascertain the most reliable hepatic segment for measurements. MATERIALS AND METHODS: 57 patients (27 female, 30 male, mean age 54 years) with chronic viral hepatitis B and C underwent ARFI imaging and consecutively liver biopsy. The results were compared to the histological fibrosis degree (F), which served as the reference. 20 healthy volunteers received ARFI quantification of different segments of the liver. RESULTS: The best ARFI assessments with the lowest rate of invalid measurements were carried out by an intercostal approach to segment VII/VIII of the liver. The ARFI velocities of the healthy group had a mean of 1.09 m/s (range 0.79 - 1.32 m/s), the means of the patient group ranged from 0.83 to 4.19 m/s. ARFI quantification correlated significantly with the histological fibrosis stage (p < 0.001). The area under the receiver operating characteristic (ROC) curves for the accuracy of ARFI imaging was 85 %, 92 % and 87 % for the diagnosis of moderate fibrosis (>or= F2), severe fibrosis (>or= F3) and cirrhosis ( = F 4), respectively. CONCLUSION: This study underscores the usefulness of ARFI as a quick method for assessing liver fibrosis or cirrhosis in patients with HBV or HCV. ARFI measurements of the liver should be performed via an intercostal access. Increasing ARFI velocities correlate with higher degree of hepatic fibrosis.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatitis B Crónica/diagnóstico por imagen , Hepatitis C Crónica/diagnóstico por imagen , Cirrosis Hepática/diagnóstico por imagen , Biopsia , Estudios de Cohortes , Femenino , Hepatitis B Crónica/patología , Hepatitis B Crónica/fisiopatología , Hepatitis C Crónica/patología , Hepatitis C Crónica/fisiopatología , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Hígado/fisiopatología , Cirrosis Hepática/patología , Cirrosis Hepática/fisiopatología , Pruebas de Función Hepática , Masculino , Persona de Mediana Edad , Pronóstico , Sensibilidad y Especificidad
2.
Ultraschall Med ; 31(6): 582-8, 2010 Dec.
Artículo en Alemán | MEDLINE | ID: mdl-20183780

RESUMEN

PURPOSE: Liver metastases lead to a shortening of the HTT of an echo enhancer. Studies using SonoVue™ also showed a shortening of the HTT in healthy controls. Hence the HTT depends on the applied contrast agent. We examined whether the HTT of SonoVue™, Luminity™ und Levovist™ is useful to discriminate between patients with and without liver metastases. MATERIALS AND METHODS: We compared the arteriovenous HTT of Levovist™, Sonovue™ und Luminity™ in 20 patients with liver metastases and in 15 controls. An Acuson Sequoia™ ultrasound system was used. The HTT results from the difference of the arrival time of the microbubbles in the hepatic artery and a hepatic vein. RESULTS: Using Levovist™ six patients and three controls had to be excluded from further analysis. The arrival time was undetectable. The mean HTT values in healthy controls were: Levovsit™ 14.75 sec (SD ± 2.53 sec), SonoVue™ 9.27 sec (SD ± 2.41 sec) and Luminity™ 9.2 sec (SD ± 2.34 sec). In patients the mean HTT values were: Levovist™ 9.89 sec (SD ± 1.04 sec), SonoVue™ 6.28 sec (SD ± 2.41 sec) and Luminity™ 6.33 sec (SD ± 1.37 sec). Using a cut off of 8 sec for SonoVue™ and Luminity™, the sensitivity to exclude liver metastases was 75% and 80%. CONCLUSION: The mean HTT values of all contrast agents were shorter in patients. Levovist™ showed a longer HTT in patients and controls than Luminity™ and SonoVue™. Levovist™ showed the best separation between patients and controls but some patients and controls had to be excluded. The HTT could still be a useful tool to exclude liver metastases but the HTT depends on the contrast agent and the applied contrast technique.


Asunto(s)
Medios de Contraste/administración & dosificación , Medios de Contraste/farmacocinética , Fluorocarburos/farmacocinética , Aumento de la Imagen/métodos , Neoplasias Hepáticas/sangre , Neoplasias Hepáticas/diagnóstico por imagen , Fosfolípidos/farmacocinética , Polisacáridos/farmacocinética , Hexafluoruro de Azufre/farmacocinética , Ultrasonografía/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Tasa de Depuración Metabólica/fisiología , Persona de Mediana Edad , Valores de Referencia
3.
Ultraschall Med ; 30(2): 168-74, 2009 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-19308901

RESUMEN

PURPOSE: Sonographically guided fine-needle punctures (p.) are considered to be a low risk procedure. Interventions with needles with a larger diameter seem to cause more complications. In search of potential complications, we examined 1923 sonographically guided interventions of the liver and pancreas in a retrospective analysis. MATERIALS AND METHODS: We examined the coherence of the kind of intervention and complications. We considered bleeding with a need for transfusion and/or a need for surgical treatment as complications. Diseases and medication increasing the probability of post-interventional bleeding were also detected. RESULTS: 1923 sonographically guided interventions in the abdomen (1800 in the liver, 123 in the pancreas) were analyzed (n = 1696 diagnostic interventions, n = 227 therapeutic interventions). Needles with diameters > 1 mm were primarily used. Drainage and radiofrequency ablation (RFA) (12 % of all interventions) were performed with devices with diameters between 2 - 3.96 mm. A need for transfusion was found in 8 / 1923 patients (0.4 %), predominantly in the first 24 h. There was no significant correlation between coagulation preventing drugs (heparin, NSAIDs, antiaggregants) and bleeding events. Patients who suffered from liver cirrhosis with a thromboplastin time of < 50 % had a higher risk of post-interventional bleeding than patients with liver cirrhosis and a thromboplastin time > 50 %. Furthermore, therapeutic interventions showed higher complication rates than diagnostic procedures. CONCLUSION: Severe bleeding complications with a need for transfusion in sonographically guided procedures are rare (0.4 %). Our results showed that liver cirrhosis with a low thromboplastin time (< 50 %) seems to be the most important risk factor for patients. Overall, sonographically guided interventions are safe and have low complication rates considering careful performance and contraindications.


Asunto(s)
Biopsia con Aguja Fina/efectos adversos , Drenaje/efectos adversos , Hígado/diagnóstico por imagen , Hígado/patología , Páncreas/diagnóstico por imagen , Páncreas/patología , Hemorragia Posoperatoria/etiología , Punciones/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Biopsia con Aguja Fina/instrumentación , Ablación por Catéter , Quistes/diagnóstico por imagen , Quistes/patología , Drenaje/instrumentación , Diseño de Equipo , Humanos , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Neoplasias Hepáticas/secundario , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Tiempo de Tromboplastina Parcial , Plasma , Transfusión de Plaquetas , Hemorragia Posoperatoria/mortalidad , Tiempo de Protrombina , Punciones/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Análisis de Supervivencia
4.
Ultraschall Med ; 30(1): 58-63, 2009 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-19205086

RESUMEN

PURPOSE: Grayscale ultrasound has improved the outcome of renal cell cancer (RCC), since most significant RCCs are discovered coincidently during routine abdominal ultrasound examinations. The CT scan is currently the method of choice for further evaluation. The therapeutic approach depends on the results of the CT scan. The purpose of this study was to evaluate whether RCCs would show typical vascularization patterns in contrast-enhanced ultrasonography (CEUS). METHODS AND MATERIALS: We examined 30 patients with solid renal tumors before surgery with CEUS using the microbubble contrast agent SonoVue (Bracco, Italy). All patients had suspected malignant lesions on a CT scan. The examination was performed with an Acuson Sequoia (Siemens, Erlangen, Germany) with a low mechanical index (low MI) using the contrast agent imaging method "contrast pulsed sequencing" (CPS). We looked at the vascularization in the early phase (< 30 s) and the late phase (60 - 120 s). These findings were compared to the histopathological results. RESULTS: 25 (83 %) had an RCC, and two (7 %) patients showed an urothelial carcinoma. Benign tumors were diagnosed in three (10 %) patients. All of them were oncocytomas. In grayscale ultrasound 52 % of the RCCs were hypoechoic, 36 % isoechoic, and 12 % hyperechoic. After the application of the contrast agent, all RCCs showed a chaotic vascularization pattern. In the early phase (< 30 s), 12 tumors showed hyperperfusion, three showed isoperfusion, and nine showed hypoperfusion. During the late phase (60 - 120 s), five tumors showed hyperperfusion, nine showed isoperfusion, and ten showed hypoperfusion. One small cystic tumor did not indicate contrast enhancement at any time. CONCLUSION: In our study RCC showed chaotic vascularization in CEUS without typical vascularization patterns.


Asunto(s)
Carcinoma de Células Renales/irrigación sanguínea , Carcinoma de Células Renales/diagnóstico por imagen , Neoplasias Renales/irrigación sanguínea , Neoplasias Renales/diagnóstico por imagen , Abdomen/diagnóstico por imagen , Adenoma Oxifílico/diagnóstico por imagen , Medios de Contraste , Humanos , Ultrasonografía/métodos
5.
Ultraschall Med ; 29(2): 184-9, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18382965

RESUMEN

PURPOSE: Shortening of the hepatic transit time (HTT) of an echo enhancer indicates a potential metastatic spread to the liver. Previous studies showed a significant difference in the HTT between patients with metastases (6.5 sec) and patients without liver lesions (15 sec). The influence of benign liver lesions on the HTT is unclear, although benign liver tumors are a frequent finding. We therefore compared the HTT of benign liver lesions to the HTT of liver metastases. MATERIALS AND METHODS: Patients with focal liver lesions were enrolled in this study. We measured the HTT of an echo enhancer (Sonovue) in pulse inversion mode on the basis of time intensity curves (TIC). For this the hepatic artery and a branch of the hepatic vein were visualized simultaneously in an intercostal section. The difference between the arrival time of the echo enhancer in the hepatic artery and the hepatic vein offered the real HTT. RESULTS: 42 patients were enrolled in this study. 19 patients had metastatic growth in the liver, benign lesions were found in 23 patients. The mean HTT in patients with liver metastasis (6.4 sec +/- 1.6) was significantly less than in patients with benign lesions (10.4 sec +/- 3.4) (p < 0.001). None of the patients with liver metastasis had an HTT of greater than 10 sec. CONCLUSION: An HTT of greater than 10 sec seems to rule out liver metastasis. If the HTT is less than 10 sec, further evaluation of the liver is needed. There are indications that benign liver lesions also lead to a shortening of the HTT, but this is less pronounced than in patients with liver metastasis.


Asunto(s)
Arteria Hepática/diagnóstico por imagen , Venas Hepáticas/diagnóstico por imagen , Hepatopatías/diagnóstico por imagen , Hepatopatías/metabolismo , Hígado/diagnóstico por imagen , Hígado/metabolismo , Adulto , Anciano , Envejecimiento , Hemangioma/diagnóstico por imagen , Hemangioma/metabolismo , Humanos , Cinética , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/metabolismo , Persona de Mediana Edad , Ultrasonografía
6.
Acta Neurol Scand ; 117(4): 231-6, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18005223

RESUMEN

OBJECTIVE: To evaluate the impact of vagus nerve stimulation (VNS) on heart rate and blood pressure (BP) modulation in epilepsy patients. MATERIAL AND METHODS: Twenty-one epilepsy patients with VNS were tested during on (60 s) and off (5 min) phases. We monitored BP, RR intervals (RRI) and respiration. Spectral analysis was performed in low- (LF: 0.04-0.15 Hz) and high-frequency bands (HF: 0.15-0.5 Hz). For coherences above 0.5, we calculated the LF transfer function between systolic BP and RRI, and the HF transfer function gain and phase between RRI and respiration. Differences between the on and off phases were evaluated using Wilcoxon test. RESULTS: VNS did not change RRI and BP values. The LF power of BP and the LF and HF power of RRI increased significantly. There was a slight change in the RRI/BP LF gain and the RRI/respiration HF gain (ns). The HF phase between RRI and respiration decreased significantly. CONCLUSIONS: Our findings show that VNS influences both sympathetic and parasympathetic cardiovascular modulation. However, our results also show that VNS does not negatively influence autonomic cardiovascular regulation.


Asunto(s)
Arritmias Cardíacas/fisiopatología , Vías Autónomas/fisiología , Fenómenos Fisiológicos Cardiovasculares , Terapia por Estimulación Eléctrica/efectos adversos , Epilepsia/terapia , Nervio Vago/fisiología , Adulto , Arritmias Cardíacas/etiología , Barorreflejo/fisiología , Presión Sanguínea/fisiología , Femenino , Corazón/inervación , Corazón/fisiología , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Sistema Nervioso Parasimpático/fisiología , Respiración , Factores de Riesgo , Sistema Nervioso Simpático/fisiología
7.
Neurology ; 67(10): 1781-5, 2006 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-17130410

RESUMEN

OBJECTIVE: To evaluate whether subthalamic nucleus (STN) stimulation has an effect on the orthostatic regulation of patients with Parkinson disease (PD), we studied cardiovascular regulation during on and off phases of STN stimulation. METHODS: We examined 14 patients with PD (mean age 58.1 +/- 5.8 years, 4 women, 10 men) with bilateral STN stimulators. Patients underwent 3 minutes of head-up tilt (HUT) testing during STN stimulation and after 90 minutes interruption of stimulation. We monitored arterial blood pressure (BP), RR intervals (RRI), respiration, and skin blood flow (SBF). Baroreflex sensitivity (BRS) was assessed as the square root of the ratio of low-frequency power of RRI to the low-frequency power of systolic BP for coherences above 0.5. RESULTS: During the on phase of the STN stimulation, HUT induced no BP decrease, a significant tachycardia, and a significant decrease of SBF. During the off phase of stimulation, HUT resulted in significant decreases in BPsys and RRI and only a slight SBF decrease. HUT induced no change of BRS during stimulation, but lowered BRS when the stimulator was off (p < 0.05). CONCLUSIONS: STN stimulation of patients with PD increases peripheral vasoconstriction and BRS and stabilizes BP, thereby improving postural hypotension in patients with PD. The results indicate that STN stimulation not only alleviates motor deficits but also influences autonomic regulation in patients with PD.


Asunto(s)
Estimulación Encefálica Profunda/métodos , Enfermedad de Parkinson/complicaciones , Síndrome de Shy-Drager/etiología , Síndrome de Shy-Drager/terapia , Núcleo Subtalámico/fisiología , Vías Autónomas/fisiopatología , Presión Sanguínea/fisiología , Encéfalo/fisiopatología , Estimulación Encefálica Profunda/normas , Estimulación Encefálica Profunda/tendencias , Femenino , Respuesta Galvánica de la Piel/fisiología , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/fisiopatología , Flujo Sanguíneo Regional/fisiología , Fenómenos Fisiológicos Respiratorios , Síndrome de Shy-Drager/fisiopatología , Resultado del Tratamiento , Vasoconstricción/fisiología
8.
Eur Surg Res ; 37(5): 312-6, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16374014

RESUMEN

To increase necrotic zones, bovine livers were treated by means of three parallel-oriented radiofrequency ablation (RFA) needles spaced at 3 cm using a puncture guide. The triple application was varied as a continuous and intermittent energy application compared to a single needle applicator. In all three study arms the applied energy (60 W) and the perfusion rate (240 ml/h) were kept constant. After treatment the smallest necrosis diameter was determined. In addition, temperature and the device's power output were monitored. Our study shows that synchronous use of three RFA application needles achieves significantly larger necrosis zones ex vivo than does single needle application. Intermittent energy application heats up the necrosis faster and more evenly with highest average temperature than continuous energy application.


Asunto(s)
Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Hígado/cirugía , Animales , Bovinos , Electrodos , Hígado/patología , Procedimientos Quirúrgicos Mínimamente Invasivos/instrumentación , Necrosis/cirugía , Agujas
9.
J Clin Neurophysiol ; 19(6): 575-86, 2002 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-12488789

RESUMEN

Fabry disease is an X-linked recessive disease with a reduction of lysosomal alpha galactosidase A and consecutive storage of glycolipids e.g., in the brain, kidney, skin, and nerve fibers. Cardinal neurologic findings are hypohidrosis, painful episodes, and peripheral neuropathy. So far, the neurophysiological findings regarding the extent of large and small fiber dysfunction are contradictory. This study evaluated large and small nerve fiber function in a homogeneous group of Fabry patients. In 24 of 30 Fabry patients with creatinine below 194.7 mmol/L the authors assessed median, ulnar, and peroneal motor conduction velocity (MCV) and median, ulnar, and sural sensory conduction velocity (SCV) nerve conduction to study the function of thickly myelinated nerve fibers. In addition, the authors studied sympathetic skin responses (SSR) at both hands and feet in 24 patients. To evaluate A beta nerve fiber function, the authors determined vibratory detection thresholds (VDT) at the first toe in 30 patients. Function of A delta and C fibers was assessed by quantitative sensory testing of cold detection threshold (CDT) and heat-pain detection thresholds (HPDT). Nerve conduction studies showed significantly decreased amplitudes of MCVs and SCVs in Fabry patients as compared to controls. However, individual results of MCV and SCV studies were only mildly impaired. SSRs were present in all tested patients but SSR amplitudes were significantly decreased in Fabry patients in comparison to controls. VDT, CDT, and HPDT were significantly elevated in Fabry patients as compared to controls. However, only six patients had pathologic VDT, 19 had increased CDT, and 25 had elevated HPDT at a high level of stimulation. In Fabry patients, small fiber dysfunction is more prominent than large fiber dysfunction, confirming previous findings of sural nerve biopsies. The results suggest a higher vulnerability of small-diameter nerve fibers than of the thickly myelinated fibers.


Asunto(s)
Enfermedad de Fabry/fisiopatología , Fibras Nerviosas Mielínicas , Fibras Nerviosas Amielínicas , Conducción Nerviosa , Nervios Periféricos/fisiopatología , Adolescente , Adulto , Estimulación Eléctrica , Femenino , Respuesta Galvánica de la Piel , Humanos , Masculino , Persona de Mediana Edad , Umbral del Dolor , Umbral Sensorial , Índice de Severidad de la Enfermedad , Piel/inervación , Piel/fisiopatología , Sistema Nervioso Simpático/fisiopatología , Sensación Térmica , Vibración
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA