Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Open Vet J ; 5(1): 34-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26623361

RESUMEN

In the pre-experimental period of a clinical trial, an apparently clinically healthy sheep fitted with ruminal and abomasal cannulas showed changes in the reticular contraction pattern visualized in M-mode ultrasonogram. Radiographic examination revealed a blunt metal screw in its reticulum. By the time change in the reticular motility through the ultrasound examination was detected, the animal had still not expressed any behavioral changes. A description of the clinical case, follow-up of the findings and laboratory data, like white blood cell count, serum pepsinogen and fibrinogen concentrations, were presented. The foreign body was removed through the ruminal cannula and reticular contraction tended to normal. An association of the contraction pattern with measured clinical data was possible, leading to the conclusion that use of M-mode ultrasonography has a potential application in similar clinical situations.

2.
Vet Comp Orthop Traumatol ; 22(1): 27-31, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19151867

RESUMEN

A controlled study was designed in order to evaluate the effects of medial patellar desmotomy (MPD), combined with exercise restriction, on clinically and radiographically normal femoropatellar joints, and to identify the patellar instability by radiographic examination. MPD was performed on the right hind limb and the horses were rested for 120 days. Both hind limbs were radiographed before surgery and at 15, 30, 60, 90, and 120 days after MPD, obtaining lateromedial, flexed lateromedial, caudocranial and cranioproximal-craniodistal (skyline) views. The femorotibial and femoropatellar angles were assessed on the lateromedial views, and the distance between the medial and lateral cortex of the femur, and the distance between the medial cortex of the femur and the lateral border of the patella were evaluated in the caudocranial views. An increase in the angle between the proximal articular surface of the patella and the cranial distal surface of the femur along with enthesophyte formation and lateral deviation of the patella were found on the radiographs of the right stifles after MPD. Therefore, MPD leads to patellar instability, which can be demonstrated by the radiographic changes. The 120 days rest did not prevent the lesions caused by postsurgical patellar instability.


Asunto(s)
Caballos/cirugía , Inestabilidad de la Articulación/veterinaria , Rótula/cirugía , Complicaciones Posoperatorias/veterinaria , Animales , Artrografía/veterinaria , Artroscopía/veterinaria , Femenino , Fémur/diagnóstico por imagen , Fémur/cirugía , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Cojera Animal/etiología , Masculino , Rótula/diagnóstico por imagen , Complicaciones Posoperatorias/diagnóstico por imagen , Rodilla de Cuadrúpedos/diagnóstico por imagen , Rodilla de Cuadrúpedos/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA