1.
Health Phys ; 124(2): 106-112, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36472527

RESUMEN

ABSTRACT: The performance of several gamma detectors was investigated for emergency urine bioassay screening of two radionuclides of concern: 131 I and 137 Cs. Unspiked artificial urine samples were measured for 10 min each on four different gamma detectors: 80% relative efficiency high-purity Ge detector in standard shielding, 102% low-background high-purity Ge detector equipped with top muon shield, 78% high-purity Ge well detector in standard shielding, and 4″ × 4″ NaI well detector in standard shielding. The measured gamma spectra were analyzed in two ways: (1) for the 364-keV peak region of 131 I and 662-keV peak region of 137 Cs and (2) for the total counts in the full energy spectrum (50-2,048 keV). The results were analyzed using the principles of signal detection theory according to the Currie's formalism extended by a complete uncertainty propagation. This enabled calculation of the detection capability in terms of detection limit (Bq L -1 ) of urine, the latter referred to as minimum detectable activity. The NaI well detector had the lowest minimum detectable activities for total spectra, whereas the high-purity Ge well detector had the lowest peak minimum detectable activity values. Minimum detectable inhalation and ingestion intakes from urine bioassay were calculated from the minimum detectable activity values for urine collection 1 d, 1 wk, and 1 mo past the initial intake. The calculated intakes were compared with annual limits on intake. The results are interpreted with respect to a large-scale radiological emergency response.


Asunto(s)
Germanio , Radiactividad , Humanos , Yoduros , Yoduro de Sodio , Límite de Detección , Radioisótopos de Cesio , Radioisótopos de Yodo , Sodio
2.
J Environ Radioact ; 146: 44-50, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25913055

RESUMEN

As part of an environmental surveillance program operated by the New York State (NYS) Department of Health, measurements of various radionuclides in aquatic life (primarily fish) collected from waterways in NYS have occurred for decades. An investigation was undertaken to gain a better understanding of the occurrence, activity levels, and extent of radionuclide variations in aquatic life obtained from local waterways in relation to concentrations reported in fish from sites outside NYS (e.g., Pacific Ocean tuna). The man-made isotopes (137)Cs and (90)Sr were detectable at activities below 1 Bq/kg in the edible portions of fish from most NYS waterways, with the exception of greater activities in fish collected downstream of Brookhaven National Laboratory. Calculated effective doses resulting from eating the fish, estimated as 11-390 nSv/yr for (137)Cs and 0.3-7.9 nSv/yr for (90)Sr, are considered extremely low.


Asunto(s)
Radioisótopos de Cesio/metabolismo , Peces/metabolismo , Contaminación Radiactiva de Alimentos/análisis , Dosis de Radiación , Monitoreo de Radiación , Radioisótopos de Estroncio/metabolismo , Contaminantes Radiactivos del Agua/metabolismo , Animales , Humanos , New York , Valores de Referencia
3.
J Environ Radioact ; 138: 205-7, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25261866

RESUMEN

Due to their sensitivity and ease of use, alpha-scintillation cells are being increasingly utilized for measurements of radon ((222)Rn) in natural gas. Laboratory studies showed an average increase of 7.3% in the measurement efficiency of alpha-scintillation cells when filled with less-dense natural gas rather than regular air. A theoretical calculation comparing the atomic weight and density of air to that of natural gas suggests a 6-7% increase in the detection efficiency when measuring radon in the cells. A correction is also applicable when the sampling location and measurement laboratory are at different elevations. These corrections to the measurement efficiency need to be considered in order to derive accurate concentrations of radon in natural gas.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Gas Natural/análisis , Monitoreo de Radiación/métodos , Radón/análisis , Conteo por Cintilación/métodos , Contaminación del Aire Interior/análisis
4.
Health Phys ; 96(4): 477-82, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19276708

RESUMEN

Emanation of radon (222Rn) from granite used for countertops and mantels was measured with continuous and integrating radon monitors. Each of the 24 granite samples emitted a measurable amount of radon. Of the two analytical methods that utilized electret-based detectors, one measured the flux of radon from the granite surfaces, and the other one measured radon levels in a glass jar containing granite cores. Additional methods that were applied utilized alpha-scintillation cells and a continuous radon monitor. Measured radon flux from the granites ranged from 2 to 310 mBq m-2 s-1, with most granites emitting <20 mBq m-2 s-1. Emanation of radon from granites encapsulated in airtight containers produced equilibrium concentrations ranging from <0.01 to 11 Bq kg-1 when alpha-scintillation cells were used, and from <0.01 to 4.0 Bq kg-1 when the continuous radon monitor was used.


Asunto(s)
Materiales de Construcción/análisis , Monitoreo de Radiación/métodos , Radón/análisis , Dióxido de Silicio/análisis , Calibración
5.
J Environ Radioact ; 99(8): 1255-7, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18420317

RESUMEN

Methods currently approved for the measurement of radon ((222)Rn) in water in New York State are liquid scintillation counting and emanation into alpha-scintillation cells. A passive system using an electret ion chamber (EIC) was evaluated as an alternative for the measurement of radon in water. Over 130 water samples from a community water supply containing 32BqL(-1) and 30 standards containing 686BqL(-1) were measured using the EIC method over 1- to 4-day exposure times. For comparison, identical samples were measured using liquid scintillation counting. Results of duplicate samples were typically within 5% for liquid scintillation counting and within 10% for the EIC. With respect to accuracy, the EIC produced results that were consistently low by 11-15%.


Asunto(s)
Radón/análisis , Contaminantes Radiactivos del Agua/análisis , Conteo por Cintilación
6.
J Environ Radioact ; 85(1): 103-20, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16102878

RESUMEN

The first nuclear explosion test, named the Trinity test, was conducted on July 16, 1945 near Alamogordo, New Mexico. In the tremendous heat of the explosion, the radioactive debris fused with the local soil into a glassy material named Trinitite. Selected Trinitite samples from ground zero (GZ) of the test site were investigated in detail for radioactivity. The techniques used included alpha spectrometry, high-efficiency gamma-ray spectrometry, and low-background beta counting, following the radiochemistry for selected radionuclides. Specific activities were determined for fission products (90Sr, 137Cs), activation products (60Co, 133Ba, 152Eu, 154Eu, 238Pu, 241Pu), and the remnants of the nuclear fuel (239Pu, 240Pu). Additionally, specific activities of three natural radionuclides (40K, 232Th, 238U) and their progeny were measured. The determined specific activities of radionuclides and their relationships are interpreted in the context of the fission process, chemical behavior of the elements, as well as the nuclear explosion phenomenology.


Asunto(s)
Guerra Nuclear , Contaminantes Radiactivos/análisis , New Mexico , Análisis Espectral/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...