Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 32(5): 3532-3540, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34928414

RESUMEN

OBJECTIVES: 3D-fluid attenuation inversion recovery (FLAIR) collected 4 h after intravenous gadolinium injection can delineate the perilymphatic space (PLS) from the endolymphatic space (ELS) to capture endolymphatic hydrops, the pathological counterpart of Ménière's disease. We aimed to optimize visualization of such inner ear internal anatomy using 3D-FLAIR without injection. METHODS: 3D-FLAIR signal from different fluid compartments such as PLS and ELS was first simulated. Then, twenty-two healthy subjects were scanned at 3.0-T MRI with non-injected 3D-FLAIR using variable T2 preparations (T2Preps) (OFF, 200, 400, and 600 ms) and variable inversion times (TIs) (from 224 to 5000 ms) and different resolutions (1.0 × 1.0 × 1.5, 0.6 × 0.6 × 0.8, and 0.6 × 0.6 × 0.6 mm3). The relative contrast between PLS and ELS and the visibility of the saccule and utricle were assessed. Additionally, non-injected 3D-FLAIR with the optimal setting was tested in a Ménière patient and compared with gadolinium-injected 3D-FLAIR. RESULTS: The PLS and ELS were differentiated when T2Prep was used but not without. The relative contrast was larger with T2Prep at 400 ms than at 200 or 600 ms (0.72 ± 0.22 vs. 0.44 ± 0.11, p = 0.019; and 0.72 ± 0.22 vs. 0.46 ± 0.28, p = 0.034, respectively). The saccule and utricle were best delineated in 87. % cases with T2Prep = 400 and TI = 2100 ms at the highest resolution. Visualization of the saccule and utricle in the optimized non-injected 3D-FLAIR was similar to conventional injected 3D-FLAIR in a patient. CONCLUSIONS: Combining a specific T2Prep and TI in non-injected 3D-FLAIR could separate PLS and ELS and even the saccule and utricle, paving the way toward future application to diagnose Ménière's disease. KEY POINTS: • MRI can capture the internal anatomy of inner ear without injection of contrast media. • Specific parameters consisting of a T2 preparation of 400 ms and an inversion time of 2100 ms must be used to visualize the saccule and utricle on non-injected 3D-FLAIR.


Asunto(s)
Hidropesía Endolinfática , Enfermedad de Meniere , Medios de Contraste , Hidropesía Endolinfática/diagnóstico , Gadolinio , Gadolinio DTPA , Humanos , Imagenología Tridimensional , Inyecciones Intravenosas , Imagen por Resonancia Magnética , Masculino , Enfermedad de Meniere/diagnóstico por imagen , Sáculo y Utrículo
2.
Chem Commun (Camb) ; 54(72): 10068-10071, 2018 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-30137083

RESUMEN

Surface-confined host-guest chemistry at the air/solid interface is used for trapping a functionalized 3D Zn-phthalocyanine complex into a 2D porous supramolecular template allowing the large area functionalization of an sp2-hybridized carbon-based substrate as evidenced by STM, resonance Raman spectroscopy, and water contact angle measurements.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA